101 resultados para sagittal suture


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The deeply eroded West Gondwana Orogen is a major continental collision zone that exposes numerous occurrences of deeply subducted rocks, such as eclogites. The position of these eclogites marks the suture zone between colliding cratons, and the age of metamorphism constrains the transition from subduction-dominated tectonics to continental collision and mountain building. Here we investigate the metamorphic conditions and age of high-pressure and ultrahigh-pressure eclogites from Mali, Togo and NE-Brazil and demonstrate that continental subduction occurred within 20 million years over at least a 2,500-km-long section of the orogen during the Ediacaran. We consider this to be the earliest evidence of large-scale deep-continental subduction and consequent appearance of Himalayan-scale mountains in the geological record. The rise and subsequent erosion of such mountains in the Late Ediacaran is perfectly timed to deliver sediments and nutrients that are thought to have been necessary for the subsequent evolution of sustainable life on Earth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To compare the biomechanical properties of a ventral transarticular lag screw fixation technique, a new dorsal atlantoaxial instability (AAI) clamp, and a new ventral AAI hook plate under sagittal shear loading after transection of the ligaments of the atlantoaxial joint. STUDY DESIGN: Cadaveric biomechanical study. ANIMALS: Canine cadavers (n = 10). MATERIALS AND METHODS: The occipitoatlantoaxial region of Beagles euthanatized for reasons unrelated to the study was prepared leaving only ligamentous structures and the joint capsules between the first 2 cervical vertebrae (C1 and C2). The atlanto-occipital joints were stabilized with 2 transarticular diverging positive threaded K-wires. The occipital bone and the caudal end of C2 were embedded in polymethylmethacrylate and loaded in shear to a force of 50 Newtons. The range of motion (ROM) and neutral zone (NZ) of the atlantoaxial joint were determined after 3 loading cycles with atlantoaxial ligaments intact, after ligament transection, and after fixation with each implant. The testing order of implants was randomly assigned. The implants tested last were subjected to failure testing. RESULTS: All stabilization procedures decreased the ROM and NZ of the atlantoaxial joint compared to transected ligament specimens. Only stabilization with transarticular lag screws and ventral plates produced a significant reduction of ROM compare to intact specimens. CONCLUSION: Fixation with transarticular lag screws and a ventral hook plate was biomechanically similar and provided more rigidity compared to dorsal clamp fixation. Further load cycling to failure tests and clinical studies are required before making clinical recommendations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposed an automated three-dimensional (3D) lumbar intervertebral disc (IVD) segmentation strategy from Magnetic Resonance Imaging (MRI) data. Starting from two user supplied landmarks, the geometrical parameters of all lumbar vertebral bodies and intervertebral discs are automatically extracted from a mid-sagittal slice using a graphical model based template matching approach. Based on the estimated two-dimensional (2D) geometrical parameters, a 3D variable-radius soft tube model of the lumbar spine column is built by model fitting to the 3D data volume. Taking the geometrical information from the 3D lumbar spine column as constraints and segmentation initialization, the disc segmentation is achieved by a multi-kernel diffeomorphic registration between a 3D template of the disc and the observed MRI data. Experiments on 15 patient data sets showed the robustness and the accuracy of the proposed algorithm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION In iliosacral screw fixation, the dimensions of solely intraosseous (secure) pathways, perpendicular to the ilio-sacral articulation (optimal) with corresponding entry (EP) and aiming points (AP) on lateral fluoroscopic projections, and the factors (demographic, anatomic) influencing these have not yet been described. METHODS In 100 CTs of normal pelvises, the height and width of the secure and optimal pathways were measured on axial and coronal views bilaterally (total measurements: n=200). Corresponding EP and AP were defined as either the location of the screw head or tip at the crossing of lateral innominate bones' cortices (EP) and sacral midlines (AP) within the centre of the pathway, respectively. EP and AP were transferred to the sagittal pelvic view using a coordinate system with the zero-point in the centre of the posterior cortex of the S1 vertebral body (x-axis parallel to upper S1 endplate). Distances are expressed in relation to the anteroposterior distance of the S1 upper endplate (in %). The influence of demographic (age, gender, side) and/or anatomic (PIA=pelvic incidence angle; TCA=transversal curvature angle, PID-Index=pelvic incidence distance-index; USW=unilateral sacral width-index) parameters on pathway dimensions and positions of EP and AP were assessed (multivariate analysis). RESULTS The width, height or both factors of the pathways were at least 7mm or more in 32% and 53% or 20%, respectively. The EP was on average 14±24% behind the centre of the posterior S1 cortex and 41±14% below it. The AP was on average 53±7% in the front of the centre of the posterior S1 cortex and 11±7% above it. PIA influenced the width, TCA, PID-Index the height of the pathways. PIA, PID-Index, and USW-Index significantly influenced EP and AP. Age, gender, and TCA significantly influenced EP. CONCLUSION Secure and optimal placement of screws of at least 7mm in diameter will be unfeasible in the majority of patients. Thoughtful preoperative planning of screw placement on CT scans is advisable to identify secure pathways with an optimal direction. For this purpose, the presented methodology of determining and transferring EPs and APs of corresponding pathways to the sagittal pelvic view using a coordinate system may be useful.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Mechanical evaluation of a novel screw position used for repair in a type III distal phalanx fracture model and assessment of solar canal penetration (SCP). STUDY DESIGN: Experimental study. SAMPLE POPULATION: Disarticulated equine hooves (n = 24) and 24 isolated distal phalanges. METHODS: Hooves/distal phalanges cut in a sagittal plane were repaired with 1 of 2 different cortical screw placements in lag fashion. In group 1 (conventional screw placement), the screw was inserted halfway between the proximal border of the solar canal (SC) and the subchondral bone surface on a line parallel to the dorsal cortex, whereas in group 2, the screw was inserted more palmar/plantar, where a perpendicular line drawn from the group 1 position reached the palmar/plantar cortex. Construct strength was evaluated by 3-point bending to failure. SCP was assessed by CT imaging and macroscopically. RESULTS: Screws were significantly longer in group 2 and in forelimbs. Group 2 isolated distal phalanges had a significantly more rigid fixation compared with the conventional screw position (maximum point at failure 31%, bending stiffness 41% higher). Lumen reduction of the SC was observed in 13/52 specimens (all from group 2), of which 9 were forelimbs. CONCLUSIONS: More distal screw positioning compared with the conventionally recommended screw position for internal fixation of type III distal phalangeal fractures allows placement of a longer screw and renders a more rigid fracture fixation. The novel screw position, however, carries a higher risk of SCP

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gebiet: Chirurgie Abstract: Objectives This study reports a series of pitfalls, premature failures and explantations of the third generation Freedom SOLO bovine pericardial stentless valve. – – Methods 149 patients underwent aortic valve replacement (AVR) using the FS. Follow-up was 100% complete with an average observation time of 5.5±2.3 years (max. 8.7 years) and a total of 825 patient years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. – – Results Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92%, 88%, 80% and 70% and 62%, respectively. 14 prostheses required explantation due to valve-independent dysfunction (n=5, i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n=4, severe stenosis, n=5). Thus freedom from explantation at 5, 6, 7, 8 and 9 years was 95%, 94%, 91% and 81% and 72%, respectively. An acute vertical tear along the non-coronary/right-coronary commissure to the base occurred at a mean of 6.0 years [range 4.3?7.3 years] and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years [range 7.0?8.3 years] due to severe functional stenosis and gross calcification that included the entire aortic root. – – Conclusions The Freedom SOLO stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6 ? 7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 10-yr-old female Asian small-clawed otter (Aonyx cinerea) presented with a history of right forelimb lameness. Antebrachial radiographs revealed a Monteggia lesion, classified by cranial radial head luxation and distal diaphyseal ulnar fracture. Open reduction with placement of an ulnar-radial positional screw was performed. The lateral collateral ligament was reconstructed using suture anchored by a condylar screw and bone tunnel in the radius. Reduction and proper implant placement was confirmed on postoperative radiographs. The ulnar-radial positional screw was removed 6 wk postoperatively to allow proper supination and pronation. Limb function was greatly improved at this time; however, a mild lameness was still observed. At 7 mo postoperatively, the otter was ambulating lameness-free. Radiographs documented proper joint reduction and stable condylar screw. At 32 mo postoperatively, the otter continued to exhibit normal ambulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objectives of this study were to describe a new spinal cord injury scale for dogs, evaluate repeatability through determining inter-rater variability of scores, compare these scores to another established system (a modified Frankel scale), and determine if the modified Frankel scale and the newly developed scale were useful as prognostic indicators for return to ambulation. A group of client-owned dogs with spinal cord injury were examined by 2 independent observers who applied the new Texas Spinal Cord Injury Score (TSCIS) and a modified Frankel scale that has been used previously. The newly developed scale was designed to describe gait, postural reactions and nociception in each limb. Weighted kappa statistics were utilized to determine inter-rater variability for the modified Frankel scale and individual components of the TSCIS. Comparisons were made between raters for the overall TSCIS score and between scales using Spearman's rho. An additional group of dogs with surgically treated thoracolumbar disk herniation was enrolled to look at correlation of both scores with spinal cord signal characteristics on magnetic resonance imaging (MRI) and ambulatory outcome at discharge. The actual agreement between raters for the modified Frankel scale was 88%, with a weighted kappa value of 0.93. The TSCIS had weighted kappa scores for gait, proprioceptive positioning and nociception components that ranged from 0.72 to 0.94. Correlation between raters for the overall TSCIS score was Spearman's rho=0.99 (P<0.001). Comparison of the overall TSCIS score to the modified Frankel score resulted in a Spearman's rho value of 0.90 (P<0.001). The modified Frankel score was weakly correlated with the length of hyperintensity of the spinal cord: L2 vertebral body length ratio on mid-sagittal T2-weighted MRI (Spearman's rho=-0.45, P=0.042) as was the overall TSCIS score (Spearman's rho=-0.47, P=0.037). There was also a significant difference in admitting modified Frankel scores (P=0.029) and admitting overall TSCIS scores (P=0.02) between dogs that were ambulatory at discharge and those that were not. Results from this study suggest that the TSCIS is an easy to administer scale for evaluating canine spinal cord injury based on the standard neurological exam and correlates well with a previously described modified Frankel scale.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Successful repair of defects in the avascular zone of meniscus remains a challenge in orthopedics. This proof of concept study aimed to investigate a guided tissue regeneration approach for treatment of tears in meniscus avascular zone in a goat model. DESIGN Full-depth longitudinal tear was created in the avascular zone of the meniscus and sutured. In the two treatment groups, porcine collagen membrane was wrapped around the tear without (CM) or with injection of expanded autologous chondrocytes (CM+cells), whereas in the control group the tear remained only sutured. Gait recovery was evaluated during the entire follow-up period. On explantation at 3 and 6 months, macroscopic gross inspection assessed healing of tears, degradation of collagen membrane, potential signs of inflammation, and osteoarthritic changes. Microscopic histology scoring criteria were developed to evaluate healing of tears, the cellular response, and the inflammatory response. RESULTS Gait recovery suggested protective effect of collagen membrane and was supported by macroscopical evaluation where improved tear healing was noted in both treated groups. Histology scoring in CM compared to suture group revealed an increase in tear margins contact, newly formed connective tissue between margins, and cell formations surrounded with new matrix after 3 months yet not maintained after 6 months. In contrast, in the CM+cells group these features were observed after 3 and 6 months. CONCLUSIONS A transient, short-term guided tissue regeneration of avascular meniscal tears occurred upon application of collagen membrane, whereas addition of expanded autologous chondrocytes supported more sustainable longer term tear healing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The aim of this study was to evaluate the accuracy of linear measurements on three imaging modalities: lateral cephalograms from a cephalometric machine with a 3 m source-to-mid-sagittal-plane distance (SMD), from a machine with 1.5 m SMD and 3D models from cone-beam computed tomography (CBCT) data. METHODS Twenty-one dry human skulls were used. Lateral cephalograms were taken, using two cephalometric devices: one with a 3 m SMD and one with a 1.5 m SMD. CBCT scans were taken by 3D Accuitomo® 170, and 3D surface models were created in Maxilim® software. Thirteen linear measurements were completed twice by two observers with a 4 week interval. Direct physical measurements by a digital calliper were defined as the gold standard. Statistical analysis was performed. RESULTS Nasion-Point A was significantly different from the gold standard in all methods. More statistically significant differences were found on the measurements of the 3 m SMD cephalograms in comparison to the other methods. Intra- and inter-observer agreement based on 3D measurements was slightly better than others. LIMITATIONS Dry human skulls without soft tissues were used. Therefore, the results have to be interpreted with caution, as they do not fully represent clinical conditions. CONCLUSIONS 3D measurements resulted in a better observer agreement. The accuracy of the measurements based on CBCT and 1.5 m SMD cephalogram was better than a 3 m SMD cephalogram. These findings demonstrated the linear measurements accuracy and reliability of 3D measurements based on CBCT data when compared to 2D techniques. Future studies should focus on the implementation of 3D cephalometry in clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

STUDY DESIGN Subgroup analysis of the lumbar spinal stenosis (LSS) without degenerative spondylolisthesis diagnostic cohort of the Spine Patient Outcomes Research Trial multicenter randomized clinical trial with a concurrent observational cohort. OBJECTIVE To determine if sedimentation sign on magnetic resonance image can help with LSS treatment decisions. SUMMARY OF BACKGROUND DATA LSS is one of the most common reasons for surgery in the US elderly, but there is a dearth of reliable diagnostic tools that give a clear indication for surgery. Recent studies have suggested that positive sedimentation sign on magnetic resonance image may be a possible prognostic indicator. METHODS All patients with LSS in both the randomized and observational cohorts had imaging-confirmed stenosis, were surgical candidates, and had neurogenic claudication for at least 12 weeks prior to enrollment. Patients were categorized as "mild," "moderate," or "severe" according to stenosis severity. Of the 654 patients with LSS enrolled in Spine Patient Outcomes Research Trial, complete T2-weighted axial and sagittal digitized images of 115 patients were available for retrospective review. An independent orthopedic spine surgeon evaluated these deidentified Digital Imaging and Communications in Medicine files for the sedimentation sign. RESULTS Sixty-six percent (76/115) of patients were found to have a positive sedimentation sign. Those with a positive sedimentation sign were more likely to have stenosis at L2-L3 (33% vs. 10% P=0.016) or L3-L4 76% vs. 51%, P=0.012), and to have severe (72% vs. 33%, P<0.0001) central stenosis (93% vs. 67% P<0.001) at 2 or more concurrent levels (57% vs. 18%, P=0.01). In multivariate models, the surgical treatment effect was significantly larger in the positive sedimentation sign group for Oswestry Disability Index (-16 vs. -7; P=0.02). CONCLUSION A positive sedimentation sign was associated with a small but significantly greater surgical treatment effect for Oswestry Disability Index in patients with symptomatic LSS, after adjusting for other demographic and imaging features. These findings suggest that positive sedimentation sign may potentially be a useful adjunct to help guide an informed treatment choice regarding surgery for LSS. LEVEL OF EVIDENCE 2.