112 resultados para conventional electrocardiogram


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Pressure ulcers are associated with severe impairment for the patients and high economic load. With this study we wanted to gain more insight to the skin perfusion dynamics due to external loading. Furthermore, we evaluated the effect of different types of pressure relief mattresses. METHODS A total of 25 healthy volunteers were enrolled in the study. Perfusion dynamics of the sacral and the heel area were assessed using the O2C-device, which combines a laser light, to determine blood flow, and white light to determine the relative amount of hemoglobin. Three mattresses were evaluated compared to a hard surface: a standard hospital foam mattress bed, a visco-elastic foam mattress, and an air-fluidized bed. RESULTS In the heel area, only the air-fluidized bed was able to maintain the blood circulation (mean blood flow of 13.6 ± 6 versus 3.9 ± 3 AU and mean relative amount of hemoglobin of 44.0 ± 14 versus 32.7 ± 12 AU.) In the sacral area, all used mattresses revealed an improvement of blood circulation compared to the hard surface. CONCLUSION The results of this study form a more precise pattern of perfusion changes due to external loading on various pressure relief mattresses. This knowledge may reduce the incidence of pressure ulcers and may be an influencing factor in pressure relief mattress selection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To assess the available evidence on the effectiveness of accelerated orthodontic tooth movement through surgical and non-surgical approaches in orthodontic patients. METHODS Randomized controlled trials and controlled clinical trials were identified through electronic and hand searches (last update: March 2014). Orthognathic surgery, distraction osteogenesis, and pharmacological approaches were excluded. Risk of bias was assessed using the Cochrane risk of bias tool. RESULTS Eighteen trials involving 354 participants were included for qualitative and quantitative synthesis. Eight trials reported on low-intensity laser, one on photobiomodulation, one on pulsed electromagnetic fields, seven on corticotomy, and one on interseptal bone reduction. Two studies on corticotomy and two on low-intensity laser, which had low or unclear risk of bias, were mathematically combined using the random effects model. Higher canine retraction rate was evident with corticotomy during the first month of therapy (WMD=0.73; 95% CI: 0.28, 1.19, p<0.01) and with low-intensity laser (WMD=0.42mm/month; 95% CI: 0.26, 0.57, p<0.001) in a period longer than 3 months. The quality of evidence supporting the interventions is moderate for laser therapy and low for corticotomy intervention. CONCLUSIONS There is some evidence that low laser therapy and corticotomy are effective, whereas the evidence is weak for interseptal bone reduction and very weak for photobiomodulation and pulsed electromagnetic fields. Overall, the results should be interpreted with caution given the small number, quality, and heterogeneity of the included studies. Further research is required in this field with additional attention to application protocols, adverse effects, and cost-benefit analysis. CLINICAL SIGNIFICANCE From the qualitative and quantitative synthesis of the studies, it could be concluded that there is some evidence that low laser therapy and corticotomy are associated with accelerated orthodontic tooth movement, while further investigation is required before routine application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To compare the archwires inserted during the final stages of the orthodontic treatment with the generated moments at 0.018- and 0.022-inch brackets. MATERIALS AND METHODS The same bracket type, in terms of prescription, was evaluated in both slot dimensions. The brackets were bonded on two identical maxillary acrylic resin models, and each model was mounted on the orthodontic measurement and simulation system. Ten 0.017 × 0.025-inch TMA and ten 0.017 × 0.025-inch stainless steel archwires were evaluated in the 0.018-inch brackets. In the 0.022-inch brackets, ten 0.019 × 0.025-inch TMA and ten 0.019 × 0.025-inch stainless steel archwires were measured. A 15° buccal root torque (+15°) and then a 15° palatal root torque (-15°) were gradually applied to the right central incisor bracket, and the moments were recorded at these positions. A t-test was conducted to compare the generated moments between wires within the 0.018- and 0.022-inch bracket groups separately. RESULTS The 0.017 × 0.025-inch archwire in the 0.018-inch brackets generated mean moments of 9.25 Nmm and 14.2 Nmm for the TMA and stainless steel archwires, respectively. The measured moments in the 0.022-inch brackets with the 0.019 × 0.025-inch TMA and stainless steel archwires were 6.6 Nmm and 9.3 Nmm, respectively. CONCLUSION The 0.017 × 0.025-inch stainless steel and β-Ti archwires in the 0.018-inch slot generated higher moments than the 0.019 × 0.025-inch archwires because of lower torque play. This difference is exaggerated in steel archwires, in comparison with the β-Ti, because of differences in stiffness. The differences of maximum moments between the archwires of the same cross-section but different alloys were statistically significant at both slot dimensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systematic reviews of well-designed trials constitute a high level of scientific evidence and are important for medical decision making. Meta-analysis facilitates integration of the evidence using a transparent and systematic approach, leading to a broader interpretation of treatment effectiveness and safety than can be attained from individual studies. Traditional meta-analyses are limited to comparing just 2 interventions concurrently and cannot combine evidence concerning multiple treatments. A relatively recent extension of the traditional meta-analytical approach is network meta-analysis, which allows, under certain assumptions, the quantitative synthesis of all evidence under a unified framework and across a network of all eligible trials. Network meta-analysis combines evidence from direct and indirect information via common comparators; interventions can therefore be ranked in terms of the analyzed outcome. In this article, the network meta-analysis approach is introduced in a nontechnical manner using a worked example on the treatment effectiveness of conventional and self-ligating appliances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The aim of the present prospective clinical study was to compare patient-reported outcomes for maxillary conventional dentures and maxillary implant-supported dentures. MATERIAL AND METHODS Twenty-one patients (6 women and 15 men) being edentulous in the maxilla and encountering problems with their existing dentures were included. Twelve patients (4 women and 8 men) received a new set of conventional dentures, due to insufficient dentures. In nine patients (2 women and 7 men), the existing dentures were adjusted by means of relining or rebasing. All patients received implant-supported dentures on two retentive anchors. In total, 42 implants were inserted in the anterior maxilla. The participants rated their satisfaction on their existing conventional dentures, 2 months after insertion of new conventional dentures and 2 months after insertion of implant-supported dentures. Thereby, patients responded to questionnaires capturing the oral health impact profile (OHIP) using visual analog scales. Seven domains (functional limitation, physical pain, psychological discomfort, physical, psychological and social disability and handicap) were assessed. Higher scores implied poorer patient satisfaction. In addition, the questionnaire involved the evaluation of cleaning ability, general satisfaction, speech, comfort, esthetics, stability, and chewing ability. Higher scores implied higher patient satisfaction. RESULTS Patient satisfaction significantly increased for implant-supported dentures compared with old dentures in all seven OHIP subgroups, as well as for cleaning ability, general satisfaction, ability to speak, comfort, esthetics, and stability (P < 0.05). The comparison of new conventional dentures and implant-supported dentures revealed a statistically significantly increased satisfaction for functional limitation (difference of 33.2 mm), psychological discomfort (difference of 36.7 mm), physical disability (difference of 36.3 mm), and social disability (difference of 23.5 mm), (P < 0.05). Additionally, general satisfaction, chewing ability, speech, and stability significantly improved in implant-supported dentures (P < 0.05). CONCLUSIONS Within the limits of this study, maxillary dentures retained by two implants provided some significant short-term improvements over conventional dentures in oral- and health-related quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND High-dose chemotherapy (HDCT) with autologous stem cell transplantation (ASCT) has been reported to confer better prognosis in systemic light chain AL-amyloidosis as compared with conventional chemotherapy. However, only limited data are available so far on treatment and outcome of AL-amyloidosis patients in Switzerland. METHODS Within a single-centre cohort of patients with biopsy confirmed AL-amyloidosis diagnosed between January 1995 and December 2012, we aimed to investigate treatment effects in patients treated with conventional chemotherapy versus HDCT with ASCT. RESULTS We identified 50 patients with AL-amyloidosis treated with conventional chemotherapy and 13 patients who received HDCT with ASCT. Clinical characteristics differed between the groups for the age of the patients (59 years for patients with ASCT/HDCT vs 69 years; p= 0.0006) and the troponin-T value (0.015 μg/l vs 0.08 μg/l; p = 0.0279). Patients with ASCT showed a trend towards better overall survival, with median survival not yet reached compared with 53 months in patients on conventional chemotherapy (p = 0.0651). CONCLUSION Our results suggest that light chain AL-amyloidosis patients considered fit to undergo HDCT and ASCT may have a better outcome than patients treated exclusively with conventional chemotherapy regimens; however, the better performance status of patients receiving HDCT may have added to this treatment effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND For patients with acute iliofemoral deep vein thrombosis, it remains unclear whether the addition of intravascular high-frequency, low-power ultrasound energy facilitates the resolution of thrombosis during catheter-directed thrombolysis. METHODS AND RESULTS In a controlled clinical trial, 48 patients (mean age 50±21 years, 52% women) with acute iliofemoral deep vein thrombosis were randomized to receive ultrasound-assisted catheter-directed thrombolysis (N=24) or conventional catheter-directed thrombolysis (N=24). Thrombolysis regimen (20 mg r-tPA over 15 hours) was identical in all patients. The primary efficacy end point was the percentage of thrombus load reduction from baseline to 15 hours according to the length-adjusted thrombus score, obtained from standardized venograms and evaluated by a core laboratory blinded to group assignment. The percentage of thrombus load reduction was 55%±27% in the ultrasound-assisted catheter-directed thrombolysis group and 54%±27% in the conventional catheter-directed thrombolysis group (P=0.91). Adjunctive angioplasty and stenting was performed in 19 (80%) patients and in 20 (83%) patients, respectively (P>0.99). Treatment-related complications occurred in 3 (12%) and 2 (8%) patients, respectively (P>0.99). At 3-month follow-up, primary venous patency was 100% in the ultrasound-assisted catheter-directed thrombolysis group and 96% in the conventional catheter-directed thrombolysis group (P=0.33), and there was no difference in the severity of the post-thrombotic syndrome (mean Villalta score: 3.0±3.9 [range 0-15] versus 1.9±1.9 [range 0-7]; P=0.21), respectively. CONCLUSIONS In this randomized controlled clinical trial of patients with acute iliofemoral deep vein thrombosis treated with a fixed-dose catheter thrombolysis regimen, the addition of intravascular ultrasound did not facilitate thrombus resolution. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01482273.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Bolt-kit systems are increasingly used as an alternative to conventional external cerebrospinal fluid (CSF) drainage systems. Since 2009 we regularly utilize bolt-kit external ventricular drainage (EVD) systems with silver-bearing catheters inserted manually with a hand drill and skull screws for emergency ventriculostomy. For non-emergency situations, we use conventional ventriculostomy with subcutaneous tunneled silver-bearing catheters, performed in the operating room with a pneumatic drill. This retrospective analysis compared the two techniques in terms of infection rates. METHODS 152 patients (aged 17-85 years, mean=55.4 years) were included in the final analysis; 95 received bolt-kit silver-bearing catheters and 57 received conventionally implanted silver-bearing catheters. The primary endpoint combined infection parameters: occurrence of positive CSF culture, colonization of catheter tips, or elevated CSF white blood cell counts (>4/μl). Secondary outcome parameters were presence of microorganisms in CSF or on catheter tips. Incidence of increased CSF cell counts and number of patients with catheter malposition were also compared. RESULTS The primary outcome, defined as analysis of combined infection parameters (occurrence of either positive CSF culture, colonization of the catheter tips or raised CSF white blood cell counts >4/μl)was not significantly different between the groups (58.9% bolt-kit group vs. 63.2% conventionally implanted group, p=0.61, chi-square-test). The bolt-kit group was non-inferior and not superior to the conventional group (relative risk reduction of 6.7%; 90% confidence interval: -19.9% to 25.6%). Secondary outcomes showed no statistically significant difference in the incidence of microorganisms in CSF (2.1% bolt-kit vs. 5.3% conventionally implanted; p=0.30; chi-square-test). CONCLUSIONS This analysis indicates that silver-bearing EVD catheters implanted with a bolt-kit system outside the operating room do not significantly elevate the risk of CSF infection as compared to conventional implant methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Unless effective preventive strategies are implemented, aging of the population will result in a significant worsening of the heart failure (HF) epidemic. Few data exist on whether baseline electrocardiographic (ECG) abnormalities can refine risk prediction for HF. METHODS We examined a prospective cohort of 2,915 participants aged 70 to 79 years without preexisting HF, enrolled between April 1997 and June 1998 in the Health, Aging, and Body Composition (Health ABC) study. Minnesota Code was used to define major and minor ECG abnormalities at baseline and at year 4 follow-up. Using Cox models, we assessed (1) the association between ECG abnormalities and incident HF and (2) the incremental value of adding ECG to the Health ABC HF Risk Score using the net reclassification index. RESULTS At baseline, 380 participants (13.0%) had minor, and 620 (21.3%) had major ECG abnormalities. During a median follow-up of 11.4 years, 485 participants (16.6%) developed incident HF. After adjusting for the Health ABC HF Risk Score variables, the hazard ratio (HR) was 1.27 (95% CI 0.96-1.68) for minor and 1.99 (95% CI 1.61-2.44) for major ECG abnormalities. At year 4, 263 participants developed new and 549 had persistent abnormalities; both were associated with increased subsequent HF risk (HR 1.94, 95% CI 1.38-2.72 for new and HR 2.35, 95% CI 1.82-3.02 for persistent ECG abnormalities). Baseline ECG correctly reclassified 10.5% of patients with HF events, 0.8% of those without HF events, and 1.4% of the overall population. The net reclassification index across the Health ABC HF risk categories was 0.11 (95% CI 0.03-0.19). CONCLUSIONS Among older adults, baseline and new ECG abnormalities are independently associated with increased risk of HF. The contribution of ECG screening for targeted prevention of HF should be evaluated in clinical trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Assessment of experience gained by local referring physicians with the procedure of coronary computed tomographic angiography (CCTA) in the everyday clinical routine. MATERIALS AND METHODS A 25-item questionnaire was sent to 179 physicians, who together had referred a total of 1986 patients for CCTA. They were asked about their experience to date with CCTA, the indications for coronary imaging, and their practice in referring patients for noninvasive CCTA or invasive catheter angiography. RESULTS 53 questionnaires (30 %) were assessable, corresponding to more than 72 % of the patients referred. Of the referring physicians who responded, 94 % saw a concrete advantage of CCTA in the treatment of patients, whereby 87 % were 'satisfied' or 'very satisfied' with the reporting. For excluding coronary heart disease (CHD) where there was a low pre-test probability of disease, the physicians considered CCTA to be superior to conventional coronary diagnosis (4.2 on a scale of 1 - 5) and vice versa for acute coronary syndrome (1.6 of 5). The main reasons for unsuitability of CCTA for CT diagnosis were claustrophobia and the absence of a sinus rhythm. The level of exposure to radiation in CCTA was estimated correctly by only 42 % of the referring physicians. 90 % of the physicians reported that their patients evaluated their coronary CT overall as 'positive' or 'neutral', while 87 % of the physicians whose patients had undergone both procedures reported that the patients had experienced CCTA as the less disagreeable of the two. CONCLUSION CCTA is accepted by the referring physicians as an alternative imaging procedure for the exclusion of CHD and received a predominantly positive assessment from both the referring physicians and the patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To compare postoperative morphological and rheological conditions after eversion carotid endarterectomy versus conventional carotid endarterectomy using computational fluid dynamics. BASIC METHODS Hemodynamic metrics (velocity, wall shear stress, time-averaged wall shear stress and temporal gradient wall shear stress) in the carotid arteries were simulated in one patient after conventional carotid endarterectomy and one patient after eversion carotid endarterectomy by computational fluid dynamics analysis based on patient specific data. PRINCIPAL FINDINGS Systolic peak of the eversion carotid endarterectomy model showed a gradually decreased pressure along the stream path, the conventional carotid endarterectomy model revealed high pressure (about 180 Pa) at the carotid bulb. Regions of low wall shear stress in the conventional carotid endarterectomy model were much larger than that in the eversion carotid endarterectomy model and with lower time-averaged wall shear stress values (conventional carotid endarterectomy: 0.03-5.46 Pa vs. eversion carotid endarterectomy: 0.12-5.22 Pa). CONCLUSIONS Computational fluid dynamics after conventional carotid endarterectomy and eversion carotid endarterectomy disclosed differences in hemodynamic patterns. Larger studies are necessary to assess whether these differences are consistent and might explain different rates of restenosis in both techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Staphylococcus aureus has long been recognized as a major pathogen. Methicillin-resistant strains of S. aureus (MRSA) and methicillin-resistant strains of S. epidermidis (MRSE) are among the most prevalent multiresistant pathogens worldwide, frequently causing nosocomial and community-acquired infections. METHODS In the present pilot study, we tested a polymerase chain reaction (PCR) method to quickly differentiate Staphylococci and identify the mecA gene in a clinical setting. RESULTS Compared to the conventional microbiology testing the real-time PCR assay had a higher detection rate for both S. aureus and coagulase-negative Staphylococci (CoNS; 55 vs. 32 for S. aureus and 63 vs. 24 for CoNS). Hands-on time preparing DNA, carrying out the PCR, and evaluating results was less than 5 h. CONCLUSIONS The assay is largely automated, easy to adapt, and has been shown to be rapid and reliable. Fast detection and differentiation of S. aureus, CoNS, and the mecA gene by means of this real-time PCR protocol may help expedite therapeutic decision-making and enable earlier adequate antibiotic treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Endodontic treatment involves removal of the dental pulp and its replacement by a root canal filling. Restoration of root filled teeth can be challenging due to structural differences between vital and non-vital root-filled teeth. Direct restoration involves placement of a restorative material e.g. amalgam or composite, directly into the tooth. Indirect restorations consist of cast metal or ceramic (porcelain) crowns. The choice of restoration depends on the amount of remaining tooth, and may influence durability and cost. The decision to use a post and core in addition to the crown is clinician driven. The comparative clinical performance of crowns or conventional fillings used to restore root-filled teeth is unknown. This review updates the original, which was published in 2012. OBJECTIVES To assess the effects of restoration of endodontically treated teeth (with or without post and core) by crowns versus conventional filling materials. SEARCH METHODS We searched the following databases: the Cochrane Oral Health Group's Trials Register, CENTRAL, MEDLINE via OVID, EMBASE via OVID, CINAHL via EBSCO, LILACS via BIREME. We also searched the reference lists of articles and ongoing trials registries.There were no restrictions regarding language or date of publication. The search is up-to-date as of 26 March 2015. SELECTION CRITERIA Randomised controlled trials (RCTs) or quasi-randomised controlled trials in participants with permanent teeth that have undergone endodontic treatment. Single full coverage crowns compared with any type of filling materials for direct restoration or indirect partial restorations (e.g. inlays and onlays). Comparisons considered the type of post and core used (cast or prefabricated post), if any. DATA COLLECTION AND ANALYSIS Two review authors independently extracted data from the included trial and assessed its risk of bias. We carried out data analysis using the 'treatment as allocated' patient population, expressing estimates of intervention effect for dichotomous data as risk ratios, with 95% confidence intervals (CI). MAIN RESULTS We included one trial, which was judged to be at high risk of performance, detection and attrition bias. The 117 participants with a root-filled, premolar tooth restored with a carbon fibre post, were randomised to either a full coverage metal-ceramic crown or direct adhesive composite restoration. None experienced a catastrophic failure (i.e. when the restoration cannot be repaired), although only 104 teeth were included in the final, three-year assessment. There was no clear difference between the crown and composite group and the composite only group for non-catastrophic failures of the restoration (1/54 versus 3/53; RR 0.33; 95% CI 0.04 to 3.05) or failures of the post (2/54 versus 1/53; RR 1.96; 95% CI 0.18 to 21.01) at three years. The quality of the evidence for these outcomes is very low. There was no evidence available for any of our secondary outcomes: patient satisfaction and quality of life, incidence or recurrence of caries, periodontal health status, and costs. AUTHORS' CONCLUSIONS There is insufficient evidence to assess the effects of crowns compared to conventional fillings for the restoration of root-filled teeth. Until more evidence becomes available, clinicians should continue to base decisions about how to restore root-filled teeth on their own clinical experience, whilst taking into consideration the individual circumstances and preferences of their patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To compare the accuracy of radiography and computed tomography (CT) in predicting implant position in relation to the vertebral canal in the cervical and thoracolumbar vertebral column. STUDY DESIGN In vitro imaging and anatomic study. ANIMALS Medium-sized canine cadaver vertebral columns (n=12). METHODS Steinmann pins were inserted into cervical and thoracolumbar vertebrae based on established landmarks but without predetermination of vertebral canal violation. Radiographs and CT images were obtained and evaluated by 6 individuals. A random subset of pins was evaluated for ability to distinguish left from right pins on radiographs. The ability to correctly identify vertebral canal penetration for all pins was assessed both on radiographs and CT. Spines were then anatomically prepared and visual examination of pin penetration into the canal served as the gold standard. RESULTS Left/right accuracy was 93.1%. Overall sensitivity of radiographs and CT to detect vertebral canal penetration by an implant were significantly different and estimated as 50.7% and 93.4%, respectively (P<.0001). Sensitivity was significantly higher for complete versus partial penetration and for radiologists compared with nonradiologists for both imaging modalities. Overall specificity of radiographs and CT to detect vertebral canal penetration was 82.9% and 86.4%, respectively (P=.049). CONCLUSIONS CT was superior to radiographic assessment and is the recommended imaging modality to assess penetration into the vertebral canal. CLINICAL RELEVANCE CT is significantly more accurate in identifying vertebral canal violation by Steinmann pins and should be performed postoperatively to assess implant position.