121 resultados para Sub-lattices
Resumo:
One of the earliest accounts of duration perception by Karl von Vierordt implied a common process underlying the timing of intervals in the sub-second and the second range. To date, there are two major explanatory approaches for the timing of brief intervals: the Common Timing Hypothesis and the Distinct Timing Hypothesis. While the common timing hypothesis also proceeds from a unitary timing process, the distinct timing hypothesis suggests two dissociable, independent mechanisms for the timing of intervals in the sub-second and the second range, respectively. In the present paper, we introduce confirmatory factor analysis (CFA) to elucidate the internal structure of interval timing in the sub-second and the second range. Our results indicate that the assumption of two mechanisms underlying the processing of intervals in the second and the sub-second range might be more appropriate than the assumption of a unitary timing mechanism. In contrast to the basic assumption of the distinct timing hypothesis, however, these two timing mechanisms are closely associated with each other and share 77% of common variance. This finding suggests either a strong functional relationship between the two timing mechanisms or a hierarchically organized internal structure. Findings are discussed in the light of existing psychophysical and neurophysiological data.
Resumo:
The most influential theoretical account in time psychophysics assumes the existence of a unitary internal clock based on neural counting. The distinct timing hypothesis, on the other hand, suggests an automatic timing mechanism for processing of durations in the sub-second range and a cognitively controlled timing mechanism for processing of durations in the range of seconds. Although several psychophysical approaches can be applied for identifying the internal structure of interval timing in the second and sub-second range, the existing data provide a puzzling picture of rather inconsistent results. In the present chapter, we introduce confirmatory factor analysis (CFA) to further elucidate the internal structure of interval timing performance in the sub-second and second range. More specifically, we investigated whether CFA would rather support the notion of a unitary timing mechanism or of distinct timing mechanisms underlying interval timing in the sub-second and second range, respectively. The assumption of two distinct timing mechanisms which are completely independent of each other was not supported by our data. The model assuming a unitary timing mechanism underlying interval timing in both the sub-second and second range fitted the empirical data much better. Eventually, we also tested a third model assuming two distinct, but functionally related mechanisms. The correlation between the two latent variables representing the hypothesized timing mechanisms was rather high and comparison of fit indices indicated that the assumption of two associated timing mechanisms described the observed data better than only one latent variable. Models are discussed in the light of the existing psychophysical and neurophysiological data.
Resumo:
Atenolol is a highly prescribed anti-hypertensive pharmaceutical and a member of the group of β-blockers. It has been detected at concentrations ranging from ng L(-1) to low μg L(-1) in waste and surface waters. The present study aimed to assess the sub-lethal effects of atenolol on rainbow trout (Oncorhynchus mykiss) and to determine its tissue-specific bioconcentration. Juvenile rainbow trout were exposed for 21 and 42 days to three concentration levels of atenolol (1 μg L(-1) - environmentally relevant concentration, 10 μg L(-1), and 1000 μg L(-1)). The fish exposed to 1 μg L(-1) atenolol exhibited a higher lactate content in the blood plasma and a reduced haemoglobin content compared with the control. The results show that exposure to atenolol at concentrations greater than or equal to 10 μg L(-1) significantly reduces both the haematocrit value and the glucose concentration in the blood plasma. The activities of the studied antioxidant enzymes (catalase and superoxide dismutase) were not significantly affected by atenolol exposure, and only the highest tested concentration of atenolol significantly reduced the activity of glutathione reductase. The activities of selected CYP450 enzymes were not affected by atenolol exposure. The histological changes indicate that atenolol has an effect on the vascular system, as evidenced by the observed liver congestion and changes in the pericardium and myocardium. Atenolol was found to have a very low bioconcentration factor (the highest value found was 0.27). The bioconcentration levels followed the order liver>kidney>muscle. The concentration of atenolol in the blood plasma was below the limit of quantification (2.0 ng g(-1)). The bioconcentration factors and the activities of selected CYP450 enzymes suggest that atenolol is not metabolised in the liver and may be excreted unchanged.
Resumo:
We present the observations of energetic neutral atoms (ENAs) produced at the lunar surface in the Earth's magnetotail. When the Moon was located in the terrestrial plasma sheet, Chandrayaan-1 Energetic Neutrals Analyzer (CENA) detected hydrogen ENAs from the Moon. Analysis of the data from CENA together with the Solar Wind Monitor (SWIM) onboard Chandrayaan-1 reveals the characteristic energy of the observed ENA energy spectrum (the e-folding energy of the distribution function) ∼100 eV and the ENA backscattering ratio (defined as the ratio of upward ENA flux to downward proton flux) <∼0.1. These characteristics are similar to those of the backscattered ENAs in the solar wind, suggesting that CENA detected plasma sheet particles backscattered as ENAs from the lunar surface. The observed ENA backscattering ratio in the plasma sheet exhibits no significant difference in the Southern Hemisphere, where a large and strong magnetized region exists, compared with that in the Northern Hemisphere. This is contrary to the CENA observations in the solar wind, when the backscattering ratio drops by ∼50% in the Southern Hemisphere. Our analysis and test particle simulations suggest that magnetic shielding of the lunar surface in the plasma sheet is less effective than in the solar wind due to the broad velocity distributions of the plasma sheet protons.
Resumo:
Ice cores provide a robust reconstruction of past climate. However, development of timescales by annual-layer counting, essential to detailed climate reconstruction and interpretation, on ice cores collected at low-accumulation sites or in regions of compressed ice, is problematic due to closely spaced layers. Ice-core analysis by laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS) provides sub-millimeter-scale sampling resolution (on the order of 100μm in this study) and the low detection limits (ng L–1) necessary to measure the chemical constituents preserved in ice cores. We present a newly developed cryocell that can hold a 1m long section of ice core, and an alternative strategy for calibration. Using ice-core samples from central Greenland, we demonstrate the repeatability of multiple ablation passes, highlight the improved sampling resolution, verify the calibration technique and identify annual layers in the chemical profile in a deep section of an ice core where annual layers have not previously been identified using chemistry. In addition, using sections of cores from the Swiss/Italian Alps we illustrate the relationship between Ca, Na and Fe and particle concentration and conductivity, and validate the LA-ICP-MS Ca profile through a direct comparison with continuous flow analysis results.
Resumo:
OBJECTIVES To report on trends of tuberculosis ascertainment among HIV patients in a rural HIV cohort in Tanzania, and assessing the impact of a bundle of services implemented in December 2012, consisting of three components:(i)integration of HIV and tuberculosis services; (ii)GeneXpert for tuberculosis diagnosis; and (iii)electronic data collection. DESIGN Retrospective cohort study of patients enrolled in the Kilombero Ulanga Antiretroviral Cohort (KIULARCO), Tanzania.). METHODS HIV patients without prior history of tuberculosis enrolled in the KIULARCO cohort between 2005 and 2013 were included.Cox proportional hazard models were used to estimate rates and predictors of tuberculosis ascertainment. RESULTS Of 7114 HIV positive patients enrolled, 5123(72%) had no history of tuberculosis. Of these, 66% were female, median age was 38 years, median baseline CD4+ cell count was 243 cells/µl, and 43% had WHO clinical stage 3 or 4. During follow-up, 421 incident tuberculosis cases were notified with an estimated incidence of 3.6 per 100 person-years(p-y)[95% confidence interval(CI)3.26-3.97]. The incidence rate varied over time and increased significantly from 2.96 to 43.98 cases per 100 p-y after the introduction of the bundle of services in December 2012. Four independent predictors of tuberculosis ascertainment were identified:poor clinical condition at baseline (Hazard Ratio (HR) 3.89, 95% CI 2.87-5.28), WHO clinical stage 3 or 4 (HR 2.48, 95% CI 1.88-3.26), being antiretroviralnaïve (HR 2.97, 95% CI 2.25-3.94), and registration in 2013(HR 6.07, 95% CI 4.39-8.38). CONCLUSION The integration of tuberculosis and HIV services together with comprehensive electronic data collection and use of GeneXpert increased dramatically the ascertainment of tuberculosis in this rural African HIV cohort.
European Journal of Development Research: New Avenues for Pastoral Development in sub-Saharan Africa
Resumo:
BACKGROUND HIV-1 viral load (VL) testing is recommended to monitor antiretroviral therapy (ART) but not universally available. We examined monitoring of first-line and switching to second-line ART in sub-Saharan Africa, 2004-2013. METHODS Adult HIV-1 infected patients starting combination ART in 16 countries were included. Switching was defined as a change from a non-nucleoside reverse-transcriptase inhibitor (NNRTI)-based regimen to a protease inhibitor (PI)-based regimen, with a change of ≥1 NRTI. Virological and immunological failures were defined per World Health Organization criteria. We calculated cumulative probabilities of switching and hazard ratios with 95% confidence intervals (CI) comparing routine VL monitoring, targeted VL monitoring, CD4 cell monitoring and clinical monitoring, adjusted for programme and individual characteristics. FINDINGS Of 297,825 eligible patients, 10,352 patients (3·5%) switched during 782,412 person-years of follow-up. Compared to CD4 monitoring hazard ratios for switching were 3·15 (95% CI 2·92-3·40) for routine VL, 1·21 (1·13-1·30) for targeted VL and 0·49 (0·43-0·56) for clinical monitoring. Overall 58.0% of patients with confirmed virological and 19·3% of patients with confirmed immunological failure switched within 2 years. Among patients who switched the percentage with evidence of treatment failure based on a single CD4 or VL measurement ranged from 32·1% with clinical to 84.3% with targeted VL monitoring. Median CD4 counts at switching were 215 cells/µl under routine VL monitoring but lower with other monitoring (114-133 cells/µl). INTERPRETATION Overall few patients switched to second-line ART and switching occurred late in the absence of routine viral load monitoring. Switching was more common and occurred earlier with targeted or routine viral load testing.
Resumo:
The new mineral species vapnikite, Ca3UO6, was found in larnite pyrometamorphic rocks of the Hatrurim Formation at Jabel Harmun in the Judean desert, Palestinian Autonomy, Israel. Vapnikite is an analogue of the synthetic ordered double-perovskite β-Ca3UO6 and is isostructural with the natural fluorperovskite – cryolite Na3AlF6. Vapnikite Ca3UO6 (P21/n,Z = 2, a = 5.739(1), b = 5.951(1), c = 8.312(1) Å, β = 90.4(1)°, V = 283.9(1) Å3) forms yellow-brown xenomorphic grains with a strong vitreous lustre. Small grains up to 20 – 30 m m in size are wedged between larnite, brownmillerite and ye'elimite. Vapnikite has irregular fracture, cleavage and parting were not observed. The calculated density is 5.322 g cm–3, the microhardness is VHN25 = 534 kg mm–2 (mean of seven measurements) corresponding to the hardness of ~5 on the Mohs scale. The crystal structure of vapnikite Ca3UO6 differs from that of its synthetic analogue β-Ca3UO6 by having a larger degree of Ca, U disorder. Vapnikite formed at the high-temperature retrograde stage of pyrometamorphism when larnite rocks were altered by fluids/melts of high alkalinity.
Resumo:
Maps: Information on water resources and their uses (technical, legal, etc. issues)