132 resultados para SEGMENT-ELEVATION
Resumo:
Background The principal causes of liver enzyme elevation among HIV-hepatitis B virus (HBV) co-infected patients are the hepatotoxic effects of antiretroviral therapy (ART), alcohol abuse, ART-induced immune reconstitution and the exacerbation of chronic HBV infection. Objectives To investigate the incidence and severity of liver enzyme elevation, liver failure and death following lamivudine (3TC) withdrawal in HIV-HBV co-infected patients. Methods Retrospective analysis of the Swiss HIV Cohort Study database to assess the clinical and biological consequences of the discontinuation of 3TC. Variables considered for analysis included liver enzyme, HIV virological and immunological parameters, and medication prescribed during a 6-month period following 3TC withdrawal. Results 3TC was discontinued in 255 patients on 363 occasions. On 147 occasions (109 patients), a follow-up visit within 6 months following 3TC withdrawal was recorded. Among these patients, liver enzyme elevation occurred on 42 occasions (29%), three of them (2%) with severity grade III and five of them (3.4%) with severity grade IV elevations (as defined by the AIDS Clinical Trials Group). Three patients presented with fulminant hepatitis. One death (0.7%) was recorded. Conclusions HBV reactivation leading to liver dysfunction may be an under-reported consequence of 3TC withdrawal in HIV-HBV co-infected patients. Regular monitoring of HBV markers is warranted if active therapy against HBV is discontinued.
Resumo:
PURPOSE: To assess the outcomes in patients who required 1 or more vitreoretinal interventions for posterior segment complications arising from elective uneventful cataract surgery. SETTING: Tertiary referral center, single-center study. METHODS: A retrospective interventional case series included 56 consecutive patients who were referred for surgical correction of posterior segment complications within 6 months of cataract surgery. The study period was between 1996 and 2003, and the minimum follow-up was 5 months. RESULTS: Posterior segment complications were resolved with a single surgical intervention in 40 cases (71.4%). Within 5 months of primary surgical correction, persisting or newly arising posterior segment complications were noted in 16 cases (28.6%). After a mean of 2.1 +/- 1.4 (SD) additional surgeries, the number of eyes with posterior segment problems decreased to 7 (12.5%) (P = .035). Posterior segment complications requiring more than 1 vitreoretinal intervention included retinal detachment, endophthalmitis, and choroidal hemorrhages. After primary correction surgery, the mean best corrected visual acuity increased from 0.15 +/- 0.24 to 0.37 +/- 0.33 (P = .001) after a single intervention and to 0.39 +/- 0.32 (P>.05) after additional interventions. Although the intraocular pressure (IOP) decreased from 21.8 +/- 16.6 mm Hg to 14.9 +/- 3.4 mm Hg (P = .008), 4 (7.1%) consecutive vascular optic atrophies occurred. A reduction in corneal transparency was observed in 46.4% of patients before primary surgical correction and 12.5% after primary surgical correction (P<.001). CONCLUSIONS: In many cases, posterior segment complications arising from cataract surgery could be repaired with favorable functional and anatomical outcomes by a single vitreoretinal intervention. Additional surgery, if requested, provided stabilization of the anatomical and functional outcomes.
Resumo:
BACKGROUND: The off-label use of topical tacrolimus (Protopic) for inflammatory external eye diseases is gaining popularity. However, there are no reports on the safety profile of this new treatment option. PATIENTS AND METHODS: We treated six patients with different inflammatory eye diseases with topical tacrolimus (Protopic 0.03 %) as off-label use in addition to the conventional anti-inflammatory treatment. Patients were interviewed for side effects and serum drug concentrations were measured under steady state conditions one hour after topical application of tacrolimus ointment. RESULTS: Two patients reported a slight burning sensation immediately after application, in one patient we found a slight worsening of the dry eye problems. No patient abandoned the treatment due to side effects. Serum drug concentrations remained below the analytical threshold in all cases (< 1.5 ng/ml). CONCLUSIONS: Tacrolimus for the topical treatment of anterior segment inflammatory eye diseases is well tolerated without detectable systemic drug resorption.
Resumo:
We investigated the relative contribution of hemodynamic and clinical factors to serum natriuretic peptide elevation in seventy-one patients with either aortic stenosis or aortic regurgitation. We found that pulmonary hypertension, heart failure and renal failure are the most powerful independent predictors of natriuretic peptide elevation in patients with aortic valve disease, irrespective of the type or severity of valvular lesion itself.
Resumo:
The definition of spinal instability is still controversial. For this reason, it is essential to better understand the difference in biomechanical behaviour between healthy and degenerated human spinal segments in vivo. A novel computer-assisted instrument was developed with the objective to characterize the biomechanical parameters of the spinal segment. Investigation of the viscoelastic properties as well as the dynamic spinal stiffness was performed during a minimally invasive procedure (microdiscectomy) on five patients. Measurements were performed intraoperatively and the protocol consisted of a dynamic part, where spinal stiffness was computed, and a static part, where force relaxation of the segment under constant elongation was studied. The repeatability of the measurement procedure was demonstrated with five replicated tests. The spinal segment tissues were found to have viscoelastic properties. Preliminary tests confirmed a decrease in stiffness after decompression surgery. Patients with non-relaxed muscles showed higher stiffness and relaxation rate compared to patients with relaxed muscles, which can be explained by the contraction and relaxation reflex of muscles under fast and then static elongation. The results show the usefulness of the biomechanical characterization of the human lumbar spinal segment to improve the understanding of the contribution of individual anatomical structures to spinal stability.
Resumo:
OBJECTIVES: To evaluate the pattern of tissue remodeling after maxillary sinus floor elevation using the transalveolar osteotome technique with or without utilizing grafting materials. METHODS: During the period of 2000-2005, 252 Straumann dental implants were inserted using the transalveolar sinus floor elevation technique in a group of 181 patients. For 88 or 35% of those implants, deproteinized bovine bone mineral with a particle size of 0.25-1 mm was used as the grafting material, but for the remaining 164 implants, no grafting material was utilized. Periapical radiographs were obtained with a paralleling technique and digitized. Two investigators, who were blinded to whether grafting material was used or not, subsequently evaluated the pattern of tissue remodeling. RESULTS: The mean residual bone height was 7.5 mm (SD 2.2 mm), ranging from 2 to 12.7 mm. The mean residual bone height for implants placed with grafting material (6.4 mm) was significantly less compared with the implants installed without grafting material (8.1 mm). The implants penetrated on average 3.1 mm (SD 1.7 mm) into the sinus cavity. The measured mean radiographic bone gain using the transalveolar technique without grafting material was significantly less, 1.7 mm (SD 2 mm) compared with a mean bone gain of 4.1 mm (SD 2.4 mm), when grafting material was used. Furthermore, the probability of gaining 2 mm or more of new bone was 39.1% when no grafting material was used. The probability increased to 77.9% when the implants were installed with grafting material. CONCLUSION: When the transalveolar sinus floor elevation was performed without utilizing grafting material, only a moderate gain of new bone could be detected mesial and distal to the implants. On the other hand, when grafting material was used, a substantial gain of new bone was usually seen on the radiographs.
Resumo:
OBJECTIVES: To analyze the survival and success rates of implants installed utilizing the (transalveolar) osteotome technique, to compare peri-implant soft tissue parameters and marginal bone levels of osteotome-installed implants with implants placed using standard surgical procedures, and to evaluate patient-centered outcomes. MATERIAL AND METHODS: During 2000 to 2005, 252 Straumann dental implants were inserted in 181 patients. The surgical technique was a modification of the original osteotome technique presented by Summers. In addition to the clinical examination, the patients were asked to give their perception of the surgical procedure, utilizing a visual analogue scale. RESULTS: The cumulative survival rate of the osteotome-installed implants after a mean follow-up time of 3.2 years, was 97.4% (95% confidence intervals: 94.4-98.8%). From the 252 implants inserted, three were lost before loading and another three were lost in the first and second year. According to residual bone height the survival was 91.3% for implant sites with < or =4 mm residual bone height, and 90% for sites with 4 mm and 5 mm, when compared with that of 100% in sites with bone height of above 5 mm. According to implant length the survival rates were 100% for 12 mm, 98.7% for 10 mm, 98.7% for 8 mm and only 47.6% for 6 mm implants. Soft tissue parameters (pocket probing depth, probing attachment level, bleeding on probing and marginal bone levels) did not yield any differences between the osteotome-installed and the conventionally placed implants. More than 90% of the patients were satisfied with the implant therapy and would undergo similar therapy again if necessary. The cost associated with implant therapy was considered to be justified. CONCLUSION: In conclusion, the osteotome technique was a reliable method for implant insertion in the posterior maxilla, especially at sites with 5 mm or more of preoperative residual bone height and a relatively flat sinus floor.
Resumo:
Grafting of the maxillary sinus in both one- and two-stage protocols has become a highly predictable surgical technique for site development and for the placement of implants to support dentures. However, despite the predictability and high success rates reported for dental implants placed either simultaneously with or after a sinus floor elevation (SFE) procedure, complications have been reported. The aim of the following case report is to present an uncommon complication in a staged SFE procedure: the displacement of a dental implant into the maxillary sinus during insertion. As implant dentistry is becoming more and more popular among practitioners, and ever more demanding procedures for initial site development in jaws with bony deficiencies are being introduced into daily practice, the displacement of dental implants into the maxillary sinus during implant placement may become a more frequent complication. Management of this complication is presented, discussed, and evaluated in light of the current literature.
Resumo:
BACKGROUND: Exhaled nitric oxide (FENO) is a marker for allergic airway inflammation. We wondered whether in patients with intermittent allergic rhinitis only (i) natural pollen exposure and (ii) artificial pollen exposure by repeated nasal allergen provocations may lead to an elevation of FENO. METHODS: In two prospective studies, we compared the FENO of nonatopic controls with the FENO of nonasthmatic individuals with mild intermittent rhinitis to tree and/or grass pollen. Study I: 13 atopic individuals and seven controls had measurements of FENO, blood eosinophils and eosinophilic cationic protein (ECP) before, during and after pollen season. Study II: 16 atopic individuals and 12 controls had nasal allergen provocations on four following days out of pollen season, with daily measurements of FENO before, 2 and 6 h after provocation, and determination of blood eosinophils, ECP and FEV1 at baseline, on days 5 and 10-12. RESULTS: Natural pollen exposure (study I) caused a significant elevation of FENO in allergic individuals. Nasal allergen provocations (study II) did not elicit a statistically significant rise neither of FENO nor of blood eosinophils between baseline and day 5. However, a subgroup of four individuals with a rise of blood eosinophils during nasal allergen provocations showed also a rise of FENO. CONCLUSIONS: We suppose that in allergic rhinitis a concomitant reaction of the bronchial system is dependent on a strong local inflammation leading to a generalized immune stimulation.
Resumo:
OBJECTIVE This study tested the hypotheses that intermittent coronary sinus occlusion (iCSO) reduces myocardial ischaemia, and that the amount of ischaemia reduction is related to coronary collateral function. DESIGN Prospective case-control study with intraindividual comparison of myocardial ischaemia during two 2-min coronary artery balloon occlusions with and without simultaneous iCSO by a balloon-tipped catheter. SETTING University Hospital. PATIENTS 35 patients with chronic stable coronary artery disease. INTERVENTION 2-min iCSO. MAIN OUTCOME MEASURES Myocardial ischaemia as assessed by intracoronary (i.c.) ECG ST shift at 2 min of coronary artery balloon occlusion. Collateral flow index (CFI) without iCSO, that is, the ratio between mean distal coronary occlusive (Poccl) and mean aortic pressure (Pao) both minus central venous pressure. RESULTS I.c. ECG ST segment shift (elevation in all) at the end of the procedure with iCSO versus without iCSO was 1.33±1.25 mV versus 1.85±1.45 mV, p<0.0001. Regression analysis showed that the degree of i.c. ECG ST shift reduction during iCSO was related to CFI, best fitting a Lorentzian function (r(2)=0.61). Ischaemia reduction with iCSO was greatest at a CFI of 0.05-0.20, whereas in the low and high CFI range the effect of iCSO was absent. CONCLUSIONS ICSO reduces myocardial ischaemia in patients with chronic coronary artery disease. Ischaemia reduction by iCSO depends on coronary collateral function. A minimal degree of collateral function is necessary to render iCSO effective. ICSO cannot manifest an effect when collateral function prevents ischaemia in the first place.
Resumo:
BACKGROUND Deproteinized bovine bone mineral (DBBM) is one of the best-documented bone substitute materials for sinus floor elevation (SFE). PURPOSE DBBM is available in two particle sizes. Large particles are believed to facilitate improved neoangiogenesis compared with small ones. However, their impact on the rate of new bone formation, osteoconduction, and DBBM degradation has never been reported. In addition, the implant stability quotient (ISQ) has never been correlated to bone-to-implant contact (BIC) after SFE with simultaneous implant placement. MATERIALS AND METHODS Bilateral SFE with simultaneous implant placement was performed in 10 Göttingen minipigs. The two sides were randomized to receive large or small particle size DBBM. Two groups of 5 minipigs healed for 6 and 12 weeks, respectively. ISQ was recorded immediately after implant placement and at sacrifice. Qualitative histological differences were described and bone formation, DBBM degradation, BIC and bone-to-DBBM contact (osteoconduction) were quantified histomorphometrically. RESULTS DBBM particle size had no qualitative or quantitative impact on the amount of newly formed bone, DBBM degradation, or BIC for either of the healing periods (p > 0.05). Small-size DBBM showed higher osteoconduction after 6 weeks than large-size DBBM (p < 0.001). After 12 weeks this difference was compensated. There was no significant correlation between BIC and ISQ. CONCLUSION Small and large particle sizes were equally predictable when DBBM was used for SFE with simultaneous implant placement.
Resumo:
Aims: We examined what type of STEMI patients are more likely to undergo multivessel PCI (MPCI) in a "real-world" setting and whether MPCI leads to worse or better outcomes compared with single-vessel PCI (SPCI) after stratifying patients by risk. Methods and results: Among STEMI patients enrolled in the Swiss AMIS Plus registry between 2005 and 2012 (n=12,000), 4,941 were identified with multivessel disease. We then stratified patients based on MPCI use and their risk. High-risk patients were identified a priori as those with: 1) left main (LM) involvement (lesions, n=263); 2) out-of-hospital cardiac arrest; or 3) Killip class III/IV. Logistic regression models examined for predictors of MPCI use and the association between MPCI and in-hospital mortality. Three thousand eight hundred and thirty-three (77.6%) patients underwent SPCI and 1,108 (22.4%) underwent MPCI. Rates of MPCI were greater among high-risk patients for each of the three categories: 8.6% vs. 5.9% for out-of-hospital cardiac arrest (p<0.01); 12.3% vs. 6.2% for Killip III/IV (p<0.001); and 14.5% vs. 2.7% for LM involvement (p<0.001). Overall, in-hospital mortality after MPCI was higher when compared with SPCI (7.3% vs. 4.4%; p<0.001). However, this result was not present when patients were stratified by risk: in-hospital mortality for MPCI vs. SPCI was 2.0% vs. 2.0% (p=1.00) in low-risk patients and 22.2% vs. 21.7% (p=1.00) in high-risk patients. Conclusions: High-risk patients are more likely to undergo MPCI. Furthermore, MPCI does not appear to be associated with higher mortality after stratifying patients based on their risk.
Resumo:
Several patients with chronic critical limb ischemia show angiographically an isolated popliteal segment (IPS) and a single calf vessel (SCV) with no direct communication to the former. In this situation a bypass can be inserted from the common femoral artery to the IPS or to the SCV. The results of 73 bypass procedures--40 to an isolated popliteal segment and 33 to a single calf vessel for limb salvage--were prospectively evaluated. Eighty percent of the grafts were performed with an autogenous saphenous vein (ASV), the rest with a thin wall polytetrafluoroethylene (PTFE) prosthesis. The mean age of our patients was 75 years and many suffered from cardiovascular disease. The operative mortality rate was 3% and the mean postoperative survival 32 months. Three year patency and limb salvage rates for ASV grafts was 83% and 87% (IPS) respectively 77% and 76% (MCV); for PTFE grafts 58% and 88% (IPS) respectively 17% and 50% (MCV). There was no significant difference found in patency and limb salvage rates of the two procedures if the graft was an autogenous saphenous vein (p > 0.05). The PTFE prosthesis was only suitable for grafts inserted to the isolated popliteal segment.