119 resultados para Quantitative


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine quantitative and qualitative image quality in patients undergoing magnetic resonance (MR) cholangiography at 3.0 Tesla (T) compared with 1.5 T. MATERIALS AND METHODS: Fifty patients (30 women; mean age, 51 years) underwent MR cholangiography at 1.5 T; another 50 patients (25 women; mean age 51 years) were scanned at 3.0 T. MR sequence protocol consisted of breath-hold single-slice rapid acquisition with relaxation enhancement (RARE) and a respiratory-triggered 3D turbo spin echo (3D TSE) sequence. Maximum intensity projections were generated from the 3D TSE datasets. Contrast-to-noise ratio (CNR) measurements between the common bile duct (CBD), left and right intrahepatic duct (LHD, RHD), and periductal tissue were performed. Three radiologists assessed qualitatively the visibility of the CBD, LHD, and RHD and the overall diagnostic quality. RESULTS: Mean gain in CNR at 3.0 T versus 1.5 T in all 3 locations ranged for the RARE sequence from 7.7% to 38.1% and for the 3D TSE from 0.5% to 26.1% (P > 0.05 for all differences). Qualitative analysis did not reveal any significant difference between the 2 field strengths (P > 0.05). CONCLUSIONS: MR cholangiography at 3.0 T shows a trend toward higher CNR without improving image quality significantly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soil degradation is a major problem in the agriculturally dominated country of Tajikistan, which makes it necessary to determine and monitor the state of soils. For this purpose a soil spectral library was established as it enables the determination of soil properties with relatively low costs and effort. A total of 1465 soil samples were collected from three 10x10 km test sites in western Tajikistan. The diffuse reflectance of the samples was measured with a FieldSpec PRO FR from ASD in the spectral range from 380 to 2500 nm in laboratory. 166 samples were finally selected based on their spectral information and analysed on total C and N, organic C, pH, CaCO₃, extractable P, exchangeable Ca, Mg and K, and the fractions clay, silt and sand. Multiple linear regression was used to set up the models. Two third of the chemically analysed samples were used to calibrate the models, one third was used for hold-out validation. Very good prediction accuracy was obtained for total C (R² = 0.76, RMSEP = 4.36 g kg⁻¹), total N (R² = 0.83, RMSEP = 0.30 g kg⁻¹) and organic C (R² = 0.81, RMSEP = 3.30 g kg⁻¹), good accuracy for pH (R² = 0.61, RMSEP = 0.157) and CaCO3(R² = 0.72, RMSEP = 4.63 %). No models could be developed for extractable P, exchangeable Ca, Mg and K, and the fractions clay, silt and sand. It can be concluded that the spectral library approach has a high potential to substitute standard laboratory methods where rapid and inexpensive analysis is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the effect of two pairs of echo times (TEs) for in-phase (IP) and opposed-phase (OP) 3.0-T magnetic resonance (MR) imaging on (a) quantitative analysis prospectively in a phantom study and (b) diagnostic accuracy retrospectively in a clinical study of adrenal tumors, with use of various reference standards in the clinical study. MATERIALS AND METHODS: A fat-saline phantom was used to perform IP and OP 3.0-T MR imaging for various fat fractions. The institutional review board approved this HIPAA-compliant study, with waiver of informed consent. Single-breath-hold IP and OP 3.0-T MR images in 21 patients (14 women, seven men; mean age, 63 years) with 23 adrenal tumors (16 adenomas, six metastases, one adrenocortical carcinoma) were reviewed. The MR protocol involved two acquisition schemes: In scheme A, the first OP echo (approximately 1.5-msec TE) and the second IP echo (approximately 4.9-msec TE) were acquired. In scheme B, the first IP echo (approximately 2.4-msec TE) and the third OP echo (approximately 5.8-msec TE) were acquired. Quantitative analysis was performed, and analysis of variance was used to test for differences between adenomas and nonadenomas. RESULTS: In the phantom study, scheme B did not enable discrimination among voxels that had small amounts of fat. In the clinical study, no overlap in signal intensity (SI) index values between adenomas and nonadenomas was seen (P < .05) with scheme A. However, with scheme B, no overlap in the adrenal gland SI-to-liver SI ratio between adenomas and nonadenomas was seen (P < .05). With scheme B, no overlap in adrenal gland SI index-to-liver SI index ratio between adenomas and nonadenomas was seen (P < .05). CONCLUSION: This initial experience indicates SI index is the most reliable parameter for characterization of adrenal tumors with 3.0-T MR imaging when obtaining OP echo before IP echo. When acquiring IP echo before OP echo, however, nonadenomas can be mistaken as adenomas with use of the SI index value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To test whether quantitative stress echocardiography using contrast-based myocardial blood flow (MBF, ml x min(-1) x g(-1)) measurements can detect coronary artery disease in humans. METHODS: 48 patients eligible for pharmacological stress testing by myocardial contrast echocardiography (MCE) and willing to undergo subsequent coronary angiography were prospectively enrolled in the study. Baseline and adenosine-induced (140 microg x kg(-1) x min(-1)) hyperaemic MBF was analysed according to a three-coronary-artery-territory model. Vascular territories were categorised into three groups with increasing stenosis severity defined as percentage diameter reduction by quantitative coronary angiography. RESULTS: Myocardial blood flow reserve (MBFR)-that is, the ratio of hyperaemic to baseline MBF, was obtained in 128 (89%) territories. Mean (SD) baseline MBF was 1.073 (0.395) ml x min(-1) x g(-1) and did not differ between territories supplied by coronary arteries with mild (<50% stenosis), moderate (50%-74% stenosis) or severe (>or=75% stenosis) disease. Mean (SD) hyperaemic MBF and MBFR were 2.509 (1.078) ml x min(-1) x g(-1) and 2.54 (1.03), respectively, and decreased linearly (r2 = 0.21 and r2 = 0.39) with stenosis severity. ROC analysis revealed that a territorial MBFR <1.94 detected >or=50% stenosis with 89% sensitivity and 92% specificity. CONCLUSION: Quantitative stress testing based on MBF measurements derived from contrast echocardiography is a new method for the non-invasive and reliable assessment of coronary artery disease in humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this single-blind randomized crossover study was to evaluate specific effects of manual acupuncture on central and vegetative nervous system activity measured by quantitative electroencephalography (qEEG) and heart rate variability (HRV). DESIGN: Twenty (20) healthy volunteers (mean: 25.2 +/- 3.6 years) were monitored simultaneously using a qEEG system and a 12-channel electrocardiogram recorder during verum acupuncture (VA) at acupuncture point Large Intestine 4 (Hegu) (LI4) or placebo acupuncture (PA) at a sham point. RESULTS: In the EEG conduction of the occipital area, needle stimulation in VA increased alpha1-frequency significantly, and the ratio alpha1/theta was shifted to the benefit of alpha1 over all electrodes. The HRV parameters showed a significant increase of the low frequency/high frequency (HF) ratio during the first minute of stimulation in VA, indicating an initial increase of sympathetic activation. However, an increase of HF power in the minute after stimulation followed by a decrease in heart rate suggests delayed vagal activation. De qi (a sensation that is typical of acupuncture needling) occurred in 16 subjects during VA and in 9 volunteers during PA (80% versus 45%). CONCLUSIONS: Manual stimulation on LI4 seems to lead to specific changes in alpha EEG-frequency and in HRV parameters. A linear relationship between the HRV parameters and the alpha EEG band might point to a specific modulation of cerebral function by vegetative effects during acupuncture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stereological tools are the gold standard for accurate (i.e., unbiased) and precise quantification of any microscopic sample. The past decades have provided a broad spectrum of tools to estimate a variety of parameters such as volumes, surfaces, lengths, and numbers. Some of them require pairs of parallel sections that can be produced by either physical or optical sectioning, with optical sectioning being much more efficient when applicable. Unfortunately, transmission electron microscopy could not fully profit from these riches, mainly because of the large depth of field. Hence, optical sectioning was a long-time desire for electron microscopists. This desire was fulfilled with the development of electron tomography that yield stacks of slices from electron microscopic sections. Now, parallel optical slices of a previously unimagined small thickness (2-5nm axial resolution) can be produced. These optical slices minimize problems related to overprojection effects, and allow for direct stereological analysis, e.g., volume estimation with the Cavalieri principle and number estimation with the optical disector method. Here, we demonstrate that the symbiosis of stereology and electron tomography is an easy and efficient way for quantitative analysis at the electron microscopic level. We call this approach quantitative 3D electron microscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyze the impact of opacities in the optical pathway and image compression of 32-bit raw data to 8-bit jpg images on quantified optical coherence tomography (OCT) image analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To correlate the dimension of the visual field (VF) tested by Goldman kinetic perimetry with the extent of visibility of the highly reflective layer between inner and outer segments of photoreceptors (IOS) seen in optical coherence tomography (OCT) images in patients with retinitis pigmentosa (RP). METHODS: In a retrospectively designed cross-sectional study, 18 eyes of 18 patients with RP were examined with OCT and Goldmann perimetry using test target I4e and compared with 18 eyes of 18 control subjects. A-scans of raw scan data of Stratus OCT images (Carl Zeiss Meditec, AG, Oberkochen, Germany) were quantitatively analyzed for the presence of the signal generated by the highly reflective layer between the IOS in OCT images. Starting in the fovea, the distance to which this signal was detectable was measured. Visual fields were analyzed by measuring the distance from the center point to isopter I4e. OCT and visual field data were analyzed in a clockwise fashion every 30 degrees , and corresponding measures were correlated. RESULTS: In corresponding alignments, the distance from the center point to isopter I4e and the distance to which the highly reflective signal from the IOS can be detected correlate significantly (r = 0.75, P < 0.0001). The greater the distance in VF, the greater the distance measured in OCT. CONCLUSIONS: The authors hypothesize that the retinal structure from which the highly reflective layer between the IOS emanates is of critical importance for visual and photoreceptor function. Further research is warranted to determine whether this may be useful as an objective marker of progression of retinal degeneration in patients with RP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To identify and quantitate specific changes in optical coherence tomography (OCT) images of patients with type 2 idiopathic perifoveal telangiectasia (IPT). METHODS: In a prospectively designed, observational, case-control study, 28 eyes of 14 consecutive patients with IPT were examined with OCT and compared with eyes of 14 unaffected control subjects. Light reflectivity profiles of raw scan data of OCT images were quantitatively analyzed for differences in distance between different retinal reflectivity layers and their respective reflectivities. Maculae were examined in four separate regions: (1) central fovea, (2) nasal perifovea, (3) temporal perifovea, and (4) outside the fovea. RESULTS: Retinal thinning, shortening of the photoreceptor outer segments and loss of reflectivity of the photoreceptor ellipsoid region were found in the central foveal region as well as the nasal and temporal perifoveal regions in eyes with IPT. In addition, increased reflectivity of the outer nuclear layer was found in a sharply demarcated area of the inferotemporal perifoveal region in all affected eyes. Retinal tissue located more than 2000 mum away from the foveola was indistinguishable from that in normal eyes. CONCLUSIONS: Quantitative OCT analysis shows unique and specific changes in the photoreceptors of the central macula in IPT which can be detected from first clinical presentation. These changes may be of use as an additional diagnostic tool. Correlation of the findings in the outer nuclear layer with histologic studies may help identify the nature of the reflectivity increase and define more clearly the type of damage sustained by the photoreceptors in this condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methodological evaluation of the proteomic analysis of cardiovascular-tissue material has been performed with a special emphasis on establishing examinations that allow reliable quantitative analysis of silver-stained readouts. Reliability, reproducibility, robustness and linearity were addressed and clarified. In addition, several types of normalization procedures were evaluated and new approaches are proposed. It has been found that the silver-stained readout offers a convenient approach for quantitation if a linear range for gel loading is defined. In addition, a broad range of a 10-fold input (loading 20-200 microg per gel) fulfills the linearity criteria, although at the lowest input (20 microg) a portion of protein species will remain undetected. The method is reliable and reproducible within a range of 65-200 microg input. The normalization procedure using the sum of all spot intensities from a silver-stained 2D pattern has been shown to be less reliable than other approaches, namely, normalization through median or through involvement of interquartile range. A special refinement of the normalization through virtual segmentation of pattern, and calculation of normalization factor for each stratum provides highly satisfactory results. The presented results not only provide evidence for the usefulness of silver-stained gels for quantitative evaluation, but they are directly applicable to the research endeavor of monitoring alterations in cardiovascular pathophysiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-parametric and quantitative magnetic resonance imaging (MRI) techniques have come into the focus of interest, both as a research and diagnostic modality for the evaluation of patients suffering from mild cognitive decline and overt dementia. In this study we address the question, if disease related quantitative magnetization transfer effects (qMT) within the intra- and extracellular matrices of the hippocampus may aid in the differentiation between clinically diagnosed patients with Alzheimer disease (AD), patients with mild cognitive impairment (MCI) and healthy controls. We evaluated 22 patients with AD (n=12) and MCI (n=10) and 22 healthy elderly (n=12) and younger (n=10) controls with multi-parametric MRI. Neuropsychological testing was performed in patients and elderly controls (n=34). In order to quantify the qMT effects, the absorption spectrum was sampled at relevant off-resonance frequencies. The qMT-parameters were calculated according to a two-pool spin-bath model including the T1- and T2 relaxation parameters of the free pool, determined in separate experiments. Histograms (fixed bin-size) of the normalized qMT-parameter values (z-scores) within the anterior and posterior hippocampus (hippocampal head and body) were subjected to a fuzzy-c-means classification algorithm with downstreamed PCA projection. The within-cluster sums of point-to-centroid distances were used to examine the effects of qMT- and diffusion anisotropy parameters on the discrimination of healthy volunteers, patients with Alzheimer and MCIs. The qMT-parameters T2(r) (T2 of the restricted pool) and F (fractional pool size) differentiated between the three groups (control, MCI and AD) in the anterior hippocampus. In our cohort, the MT ratio, as proposed in previous reports, did not differentiate between MCI and AD or healthy controls and MCI, but between healthy controls and AD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intestinal intraepithelial lymphocytes (IEL) are specialized subsets of T cells with distinct functional capacities. While some IEL subsets are circulating, others such as CD8alphaalpha TCRalphabeta IEL are believed to represent non-circulating resident T cell subsets [Sim, G.K., Intraepithelial lymphocytes and the immune system. Adv. Immunol., 1995. 58: 297-343.]. Current methods to obtain enriched preparations of intraepithelial lymphocytes are mostly based on Percoll density gradient or magnetic bead-based technologies [Lundqvist, C., et al., Isolation of functionally active intraepithelial lymphocytes and enterocytes from human small and large intestine. J. Immunol. Methods, 1992. 152(2): 253-263.]. However, these techniques are hampered by a generally low yield of isolated cells, and potential artifacts due to the interference of the isolation procedure with subsequent functional assays, in particular, when antibodies against cell surface markers are required. Here we describe a new method for obtaining relatively pure populations of intestinal IEL (55-75%) at a high yield (>85%) by elutriation centrifugation. This technique is equally suited for the isolation and enrichment of intraepithelial lymphocytes of both mouse and human origin. Time requirements for fractionating cell suspensions by elutriation centrifugation are comparable to Percoll-, or MACS-based isolation procedures. Hence, the substantially higher yield and the consistent robust enrichment for intraepithelial lymphocytes, together with the gentle treatment of the cells during elutriation that does not interfere with subsequent functional assays, are important aspects that are in favor of using this elegant technology to obtain unmanipulated, unbiased populations of intestinal intraepithelial lymphocytes, and, if desired, also of pure epithelial cells.