156 resultados para Oak Park (Ill.)
Resumo:
PURPOSE: The aim of this review was to evaluate the clinical outcomes for the different time points of implant placement following tooth extraction. MATERIALS AND METHODS: A PubMed search and a hand search of selected journals were performed to identify clinical studies published in English that reported on outcomes of implants in postextraction sites. Only studies that included 10 or more patients were accepted. For implant success/survival outcomes, only studies with a mean follow-up period of at least 12 months from the time of implant placement were included. The following outcomes were identified: (1) change in peri-implant defect dimension, (2) implant survival and success, and (3) esthetic outcomes. RESULTS AND CONCLUSIONS: Of 1,107 abstracts and 170 full-text articles considered, 91 studies met the inclusion criteria for this review. Bone augmentation procedures are effective in promoting bone fill and defect resolution at implants in postextraction sites, and are more successful with immediate (type 1) and early placement (type 2 and type 3) than with late placement (type 4). The majority of studies reported survival rates of over 95%. Similar survival rates were observed for immediate (type 1) and early (type 2) placement. Recession of the facial mucosal margin is common with immediate (type 1) placement. Risk indicators included a thin tissue biotype, a facial malposition of the implant, and a thin or damaged facial bone wall. Early implant placement (type 2 and type 3) is associated with a lower frequency of mucosal recession compared to immediate placement (type 1).
Resumo:
PURPOSE: To systematically appraise the impact of mechanical/technical risk factors on implant-supported reconstructions. MATERIAL AND METHODS: A MEDLINE (PubMed) database search from 1966 to April 2008 was conducted. The search strategy was a combination of MeSH terms and the key words: design, dental implant(s), risk, prosthodontics, fixed prosthodontics, fixed partial denture(s), fixed dental prosthesis (FDP), fixed reconstruction(s), oral rehabilitation, bridge(s), removable partial denture(s), overdenture(s). Randomized controlled trials, controlled trials, and prospective and retrospective cohort studies with a mean follow-up of at least 4 years were included. The material evaluated in each study had to include cases with/without exposure to the risk factor. RESULTS: From 3,568 articles, 111 were selected for full text analysis. Of the 111 articles, 33 were included for data extraction after grouping the outcomes into 10 risk factors: type of retentive elements supporting overdentures, presence of cantilever extension(s), cemented versus screw-retained FDPs, angled/angulated abutments, bruxism, crown/implant ratio, length of the suprastructure, prosthetic materials, number of implants supporting an FDP, and history of mechanical/technical complications. CONCLUSIONS: The absence of a metal framework in overdentures, the presence of cantilever extension(s) > 15 mm and of bruxism, the length of the reconstruction, and a history of repeated complications were associated with increased mechanical/technical complications. The type of retention, the presence of angled abutments, the crown-implant ratio, and the number of implants supporting an FDP were not associated with increased mechanical/technical complications. None of the mechanical/technical risk factors had an impact on implant survival and success rates.
Resumo:
PURPOSE: To evaluate early and immediate loading of implants in the posterior maxilla and to investigate whether there is a difference in success rates, survival rates, and peri-implant parameters, including marginal bone level changes. MATERIALS AND METHODS: A comprehensive systematic review of the literature was conducted. The selection of publications reporting on human clinical studies was based on predetermined inclusion criteria and was agreed upon by two reviewers. RESULTS: Twelve papers were identified on early loading (two randomized controlled clinical trials [RCTs] and 10 prospective case series studies). Six papers were found on immediate loading (one RCT, four prospective case series, and one retrospective study). CONCLUSIONS: Under certain circumstances it is possible to successfully load dental implants in the posterior maxilla early or immediately after their placement in selected patients. The success rate appears to be technique sensitive, although no study has directly assessed this. A high degree of primary implant stability (high value of insertion torque) and implant surface characteristics play an important role. It is not possible to draw evidence-based conclusions concerning contraindications, threshold values for implant stability, bone quality and quantity needed, or impact of occlusal loading forces. As for the impact of the surgical technique on implant outcome in different bone densities, no studies prove significant superior results with one technique over another. Well-designed RCTs with a large number of patients are necessary to make early/immediate loading protocols in posterior maxilla evidence based, but ethical and practical considerations may limit the real possibility of such studies in the near future.
Resumo:
PURPOSE: To compare dynamic contrast material-enhanced magnetic resonance (MR) imaging and diffusion-weighted MR imaging for noninvasive evaluation of early and late effects of a vascular targeting agent in a rat tumor model. MATERIALS AND METHODS: The study protocol was approved by the local ethics committee for animal care and use. Thirteen rats with one rhabdomyosarcoma in each flank (26 tumors) underwent dynamic contrast-enhanced imaging and diffusion-weighted echo-planar imaging in a 1.5-T MR unit before intraperitoneal injection of combretastatin A4 phosphate and at early (1 and 6 hours) and later (2 and 9 days) follow-up examinations after the injection. Histopathologic examination was performed at each time point. The apparent diffusion coefficient (ADC) of each tumor was calculated separately on the basis of diffusion-weighted images obtained with low b gradient values (ADC(low); b = 0, 50, and 100 sec/mm(2)) and high b gradient values (ADC(high); b = 500, 750, and 1000 sec/mm(2)). The difference between ADC(low) and ADC(high) was used as a surrogate measure of tissue perfusion (ADC(low) - ADC(high) = ADC(perf)). From the dynamic contrast-enhanced MR images, the volume transfer constant k and the initial slope of the contrast enhancement-time curve were calculated. For statistical analyses, a paired two-tailed Student t test and linear regression analysis were used. RESULTS: Early after administration of combretastatin, all perfusion-related parameters (k, initial slope, and ADC(perf)) decreased significantly (P < .001); at 9 days after combretastatin administration, they increased significantly (P < .001). Changes in ADC(perf) were correlated with changes in k (R(2) = 0.46, P < .001) and the initial slope (R(2) = 0.67, P < .001). CONCLUSION: Both dynamic contrast-enhanced MR imaging and diffusion-weighted MR imaging allow monitoring of perfusion changes induced by vascular targeting agents in tumors. Diffusion-weighted imaging provides additional information about intratumoral cell viability versus necrosis after administration of combretastatin.
Resumo:
PURPOSE: To prospectively determine reproducibility of magnetic resonance (MR) angiography and MR spectroscopy of deoxymyoglobin in assessment of collateral vessels and tissue perfusion in patients with critical limb ischemia (CLI) and to follow changes in patients undergoing intramuscular vascular endothelial growth factor (pVEGF)-C gene therapy, percutaneous transluminal angioplasty, supervised exercise training, or no therapy. MATERIALS AND METHODS: Study and gene therapy protocols were approved, and all patients gave written informed consent. To determine repeatability and reproducibility, seven patients underwent MR angiography and five underwent MR spectroscopy. The techniques were used to judge disease progress in 12 other patients with or without therapy: MR angiography to help determine change in visualization of collateral vessels and MR spectroscopy to help assess change in perfusion at proximal and distal calf levels. MR angiographic results were subjectively analyzed by three blinded readers. Intraobserver variability was expressed as 95% confidence interval (CI) (n=7); interobserver variability, as kappa statistic (n=15). Reexamination variability of MR spectroscopy was given as 95% CI for subsequent recovery times, and correlation with disease extent was calculated with Kendall taub rank correlation. Fisher-Yates test was used to correlate changes with pressure measurements and clinical course. RESULTS: Intraobserver and interobserver concordance was sensitive for detection of collateral vessels. Intraobserver agreement was 85.7% (95% CI: 42.1%, 99.6%). Interobserver agreement was high for small collateral vessels (kappa=0.74, P <.001) and fair for large collateral vessels (kappa=0.36, P=.002). MR spectroscopy was reproducible (95% CI: +/-26 seconds for proximal, +/-21 seconds for distal) and showed a correlation with disease extent (proximal calf, taub=0.84, P <.001; distal calf, taub=0.68, P=.04). Small collateral vessels increased over time (P=.04) but did not correlate with pressure measurements and clinical course. Recovery time correlated with clinical course (proximal calf, P=.03; distal calf, P=.005). CONCLUSION: MR angiography and MR spectroscopy of deoxymyoglobin can help document changes in visualization of collateral vessels and tissue perfusion in patients with CLI.
Resumo:
PURPOSE: To prospectively assess the potential of noninvasive diffusion-weighted magnetic resonance (MR) imaging to depict changes in microperfusion and diffusion in patients with acute unilateral ureteral obstruction. MATERIALS AND METHODS: The local ethics committee approved the study protocol. Informed consent was obtained. Diffusion-weighted MR imaging was performed in 21 patients (two women, 19 men; mean age, 43 years +/- 10 [standard deviation]) with acute unilateral ureteral obstruction due to a calculus diagnosed at unenhanced computed tomography. A control group (one woman, 15 men; mean age, 44 years +/- 12) underwent the same MR protocol. Standard processing yielded an apparent diffusion coefficient (ADC) ADCT; the separation of microperfusion and diffusion contributions yielded the perfusion fraction FP and the pure diffusion coefficient ADCD. ADCT, ADCD, and FP were compared between obstructed and contralateral unobstructed kidneys and with control values. For statistical analysis, nonparametric rank tests were used. A P value of less than .05 was considered significant. RESULTS: No significant differences were observed between the ADCT of the medulla or cortex of the obstructed and unobstructed kidneys. Compared with control kidneys, only medullary ADCT was slightly increased in the obstructed kidney (P < .04). However, the ADCD in the medulla of the obstructed and unobstructed kidneys was significantly higher than that in control subjects (201 x 10(-5) mm2/sec +/- 16 and 199 x 10(-5) mm2/sec +/- 20 vs 189 x 10(-5) mm2/sec +/- 12; P < .008 and P < .03, respectively). FP of the cortex of the obstructed kidney was significantly lower than that in the unobstructed kidney (20.2% +/- 4.8 vs 24.0% +/- 5.8; P < .002); FP of the medulla was slightly lower in the obstructed kidney than in the unobstructed kidney (18.3% +/- 5.9 vs 20.7% +/- 6.4; P = .05). CONCLUSION: Diffusion-weighted MR imaging allows noninvasive detection of changes in renal perfusion and diffusion during acute unilateral ureteral obstruction, as exemplified in patients with a ureteral calculus.
Resumo:
PURPOSE: Resonance frequency analysis (RFA) offers the opportunity to monitor the osseointegration of an implant in a simple, noninvasive way. A better comprehension of the relationship between RFA and parameters related to bone quality would therefore help clinicians improve diagnoses. In this study, a bone analog made from polyurethane foam was used to isolate the influences of bone density and cortical thickness in RFA. MATERIALS AND METHODS: Straumann standard implants were inserted in polyurethane foam blocks, and primary implant stability was measured with RFA. The blocks were composed of two superimposed layers with different densities. The top layer was dense to mimic cortical bone, whereas the bottom layer had a lower density to represent trabecular bone. Different densities for both layers and different thicknesses for the simulated cortical layer were tested, resulting in eight different block combinations. RFA was compared with two other mechanical evaluations of primary stability: removal torque and axial loading response. RESULTS: The primary stability measured with RFA did not correlate with the two other methods, but there was a significant correlation between removal torque and the axial loading response (P < .005). Statistical analysis revealed that each method was sensitive to different aspects of bone quality. RFA was the only method able to detect changes in both bone density and cortical thickness. However, changes in trabecular bone density were easier to distinguish with removal torque and axial loading than with RFA. CONCLUSIONS: This study shows that RFA, removal torque, and axial loading are sensitive to different aspects of the bone-implant interface. This explains the absence of correlation among the methods and proves that no standard procedure exists for the evaluation of primary stability.
Resumo:
PURPOSE: This retrospective study reports the clinical outcome following placement of extraoral implants in severely resorbed posterior ridges to support distal-extension removable dentures. MATERIAL AND METHODS: Consecutively treated patients with partially or completely edentulous ridges, with available bone height in the posterior region of 6 mm or less, were included in the study. Implants originally intended for extraoral use (Straumann) were placed in second molar regions and allowed to heal for 4 to 6 months before abutment connection. At recall appointments, the peri-implant hard and soft tissues were evaluated. Complications with implant components, as well as mechanical and structural failures of the prostheses, were recorded. Two-year survival rates were calculated and life table analyses undertaken. RESULTS: Twenty-nine patients (19 women and 10 men; average age 61.2 years, range, 44 to 75 years) were included in the study. Forty-seven extraoral implants in 26 patients were placed in the second molar site of the mandible. Two extraoral implants in 2 patients failed during the osseointegration phase, yielding an 8-year cumulative success rate of 91.8%. The mean distance from the extraoral implants to the most distal tooth/implant was 28.1 mm (range, 16.7 to 39.2 mm). Twenty-three extraoral implants were restored with magnets, 18 with ball anchors, and 4 with conical cylinders. Replacement of abutments and retention elements was necessary in 2 patients. Four abutments in 2 patients were disconnected from the restorations. CONCLUSIONS: Within the limits of the employed research design, extraoral implants may be used successfully to provide support for distal-extension removable dentures in severely resorbed posterior alveolar ridges.
Resumo:
To prospectively compare the diagnostic accuracy of steady-state, high-spatial-resolution magnetic resonance (MR) angiography of the lower leg, performed with a blood pool contrast agent, with selective digital subtraction angiography (DSA) as the reference standard in patients with symptomatic peripheral arterial disease.
Resumo:
To analyze the detection of endoleaks with low-tube-voltage computed tomographic (CT) angiography.
Resumo:
PURPOSE: To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. MATERIALS AND METHODS: Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. RESULTS: Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. CONCLUSION: Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.
Resumo:
The purpose of this study was to analyze the immediate and long-term angiographic and clinical results of endovascular treatment of posterior circulation aneurysms with special regard to technical development.
Resumo:
PURPOSE: To determine if multi–detector row computed tomography (CT) can replace conventional radiography and be performed alone in severe trauma patients for the depiction of thoracolumbar spine fractures. MATERIALS AND METHODS: One hundred consecutive severe trauma patients who underwent conventional radiography of the thoracolumbar spine as well as thoracoabdominal multi–detector row CT were prospectively identified. Conventional radiographs were reviewed independently by three radiologists and two orthopedic surgeons; CT images were reviewed by three radiologists. Reviewers were blinded both to one another’s reviews and to the results of initial evaluation. Presence, location, and stability of fractures, as well as quality of reviewed images, were assessed. Statistical analysis was performed to determine sensitivity and interobserver agreement for each procedure, with results of clinical and radiologic follow-up as the standard of reference. The time to perform each examination and the radiation dose involved were evaluated. A resource cost analysis was performed. RESULTS: Sixty-seven fractured vertebrae were diagnosed in 26 patients. Twelve patients had unstable spine fractures. Mean sensitivity and interobserver agreement, respectively, for detection of unstable fractures were 97.2% and 0.951 for multi–detector row CT and 33.3% and 0.368 for conventional radiography. The median times to perform a conventional radiographic and a multi–detector row CT examination, respectively, were 33 and 40 minutes. Effective radiation doses at conventional radiography of the spine and thoracoabdominal multi–detector row CT, respectively, were 6.36 mSv and 19.42 mSv. Multi–detector row CT enabled identification of 146 associated traumatic lesions. The costs of conventional radiography and multi–detector row CT, respectively, were $145 and $880 per patient. CONCLUSION: Multi–detector row CT is a better examination for depicting spine fractures than conventional radiography. It can replace conventional radiography and be performed alone in patients who have sustained severe trauma.
Resumo:
BACKGROUND: The adequacy of thromboprophylaxis prescriptions in acutely ill hospitalized medical patients needs improvement. OBJECTIVE: To prospectively assess the efficacy of thromboprophylaxis adequacy of various clinical decision support systems (CDSS) with the aim of increasing the use of explicit criteria for thromboprophylaxis prescription in nine Swiss medical services. METHODS: We randomly assigned medical services to a pocket digital assistant program (PDA), pocket cards (PC) and no CDSS (controls). In centers using an electronic chart, an e-alert system (eAlerts) was developed. After 4 months, we compared post-CDSS with baseline thromboprophylaxis adequacy for the various CDSS and control groups. RESULTS: Overall, 1085 patients were included (395 controls, 196 PC, 168 PDA, 326 eAlerts), 651 pre- and 434 post-CDSS implementation: 472 (43.5%) presented a risk of VTE justifying thromboprophylaxis (31.8% pre, 61.1% post) and 556 (51.2%) received thromboprophylaxis (54.2% pre, 46.8% post). The overall adequacy (% patients with adequate prescription) of pre- and post-CDSS implementation was 56.2 and 50.7 for controls (P = 0.29), 67.3 and 45.3 for PC (P = 0.002), 66.0 and 64.9 for PDA (P = 0.99), 50.5 and 56.2 for eAlerts (P = 0.37), respectively, eAlerts limited overprescription (56% pre, 31% post, P = 0.01). CONCLUSION: While pocket cards and handhelds did not improve thromboprophylaxis adequacy, eAlerts had a modest effect, particularly on the reduction of overprescription. This effect only partially contributes to the improvement of patient safety and more work is needed towards institution-tailored tools.