177 resultados para ORTHOPEDIC IMPLANTS
Resumo:
In the past, several modifications of specific surface properties such as topography, structure, chemistry, surface charge, and wettability have been investigated to predictably improve the osseointegration of titanium implants. The aim of the present review was to evaluate, based on the currently available evidence, the impact of hydrophilic surface modifications of titanium for dental implants. A surface treatment was performed to produce hydroxylated/hydrated titanium surfaces with identical microstructure to either acid-etched, or sand-blasted, large grit and acid-etched substrates, but with hydrophilic character. Preliminary in vitro studies have indicated that the specific properties noted for hydrophilic titanium surfaces have a significant influence on cell differentiation and growth factor production. Animal experiments have pointed out that hydrophilic surfaces improve early stages of soft tissue and hard tissue integration of either nonsubmerged or submerged titanium implants. This data was also corroborated by the results from preliminary clinical studies. In conclusion, the present review has pointed to a potential of hydrophilic surface modifications to support tissue integration of titanium dental implants.
Resumo:
OBJECTIVES: To compare the histological features of bone filled with Bio-Oss, Ostim-Paste or PerioGlas placed in defects in the rabbit tibiae by evaluating bone tissue composition and the integration of titanium implants placed in the grafted bone. MATERIAL AND METHODS: Two cylindrical bone defects, about 4 mm in diameter and 6 mm in depth, were created in the tibiae of 10 rabbits. The defects were filled with either Bio-Oss, PerioGlas, Ostim-Paste or left untreated, and covered with a collagen membrane. Six weeks later, one titanium sandblasted and acid-etched (SLA) implant was inserted at the centre of each previously created defect. The animals were sacrificed after 6 weeks of healing. RESULTS: Implants placed in bone previously grafted with Bio-Oss, PerioGlas or Ostim-Paste obtained a larger extent of osseointegration, although not statistically significant, than implants placed in non-grafted bone. The three grafting materials seemed to perform in a similar way concerning their contribution towards implant osseointegration. All grafting materials appeared to be osteoconductive, thus leading to the formation of bridges of mineralized bone extending from the cortical plate towards the implants surface through the graft scaffold. CONCLUSIONS: Grafting with the above-mentioned biomaterials did not add any advantage to the osseointegration of titanium SLA implants in a self-contained defect.
Resumo:
OBJECTIVE: Immediate and early loading of dental implants can simplify treatment and increase overall patient satisfaction. The purpose of this 3-year prospective randomized-controlled multicenter study was to assess the differences in survival rates and bone level changes between immediately and early-loaded implants with a new chemically modified surface (SLActive). This investigation shows interim results obtained after 5 months. MATERIAL AND METHODS: Patients > or =18 years of age missing at least one tooth in the posterior maxilla or mandible were enrolled in the study. Following implant placement, patients received a temporary restoration either on the day of surgery (immediate loading) or 28-34 days after surgery (early loading); restorations consisted of single crowns or two to four unit fixed dental prostheses. Permanent restorations were placed 20-23 weeks following surgery. The primary efficacy variable was change in bone level (assessed by standardized radiographs) from baseline to 5 months; secondary variables included implant survival and success rates. RESULTS: A total of 266 patients were enrolled (118 males and 148 females), and a total of 383 implants were placed (197 and 186 in the immediate and early loading groups, respectively). Mean patient age was 46.3+/-12.8 years. After 5 months, implant survival rates were 98% in the immediate group and 97% in the early group. Mean bone level change from baseline was 0.81+/-0.89 mm in the immediate group and 0.56+/-0.73 mm in the early group (P<0.05). Statistical analysis revealed a significant center effect (P<0.0001) and a significant treatment x center interaction (P=0.008). CONCLUSIONS: The results suggested that Straumann implants with an SLActive can be used predictably in time-critical (early or immediate) loading treatment protocols when appropriate patient selection criteria are observed. The mean bone level changes observed from baseline to 5 months (0.56 and 0.81 mm) corresponded to physiological observations from other studies, i.e., were not clinically significant. The presence of a significant center effect and treatment x center interaction indicated that the differences in bone level changes between the two groups were center dependent.
Resumo:
Background: The goal of this study was to retrospectively analyze a cohort of 136 patients who underwent dental implant placement in the posterior maxilla at the University of Connecticut Health Center to assess and identify predictors for implant failure in the posterior maxilla. Methods: Data were retrieved from patient charts to identify subjects older than 21 years of age who received dental implant(s) in the posterior maxilla. Patients without a postoperative baseline radiograph were excluded. A recall radiograph was taken 3 to 6 months after implant placement. If there was no recall radiograph, the subject was contacted for a recall visit that included a clinical evaluation and radiographs to determine the implant status. Based on a univariate screening, variables considered potential implant failure predictors included gender, diabetes, smoking, implant length, implant diameter, membrane use, sinus-elevation technique, and surgical complications. These parameters were further assessed, and a multivariable logistic regression was performed with implant failure as a dependant variable. All tests of significance were evaluated at the 0.05 error level. Results: Two hundred seventy-three implants were placed in the posterior maxilla. Fourteen implants failed (early and late failures combined), resulting in a 94.9% overall survival rate. The survival rates for the sinus-elevation group and native bone group were 92.2% and 96.7%, respectively (P = 0.090). Based on the multivariable analysis, sinus floor-elevation procedures were not associated with increased risk for implant failure (P = 0.702). In contrast, smoking and surgical complications had a statistically significant effect on implant failure; the odds ratios for implant failure were 6.4 (P = 0.025) and 8.2 (P = 0.004), respectively. Conclusion: Sinus-elevation procedures with simultaneous or staged implant placement do not increase the risk for implant failure, whereas smoking and surgical complications markedly increase the risk for implant failure.
Resumo:
This case series reports on the use of nonsilica-based high-strength full ceramics for different prosthetic indications. Fifty-two consecutive patients received tooth- or implant-supported zirconia reconstructions during a 2-year period. The observation period for reexamination was 12 to 30 months. The most frequent indications were single crowns and short-span fixed partial dentures. A few implant superstructures were screw-retained, whereas all remaining restorations were cemented on natural teeth or zirconia implant abutments. Clinical examination included biologic (probing depths, bleeding on probing) and esthetic (Papilla Index) parameters, as well as technical complications. No implant was lost or caused any problems, but two teeth were lost after horizontal fracture. Overall, the periodontal parameters were favorable. Fractures of frameworks or implant abutments were not observed. Abutment-screw loosening occurred once for one premolar single crown. Furthermore, five implant crowns in the posterior region exhibited chipping of the porcelain veneering material. With regard to esthetics, no reconstructions were considered unacceptable, but three crowns were remade shortly after delivery. In this short-term study, it was observed that biologic, esthetic, and mechanical properties of zirconia were favorable, and the material could be used in various prosthetic indications on teeth or implants.
Resumo:
BACKGROUND: There is evidence for the superiority of two-implant overdentures over complete dentures in the mandible. Various anchorage devices were used to provide stability to overdentures. The aim of the present study was to compare two designs of a rigid bar connecting two mandibular implants. MATERIALS AND METHODS: Completely edentulous patients received a new denture in the maxilla and an implant-supported overdenture in the mandible. They were randomly allocated to two groups (A or B) with regard to the bar design. A standard U-shaped bar (Dolder bar) was used connecting the two implants in a straight line. For comparison, precision attachments were soldered distal to the bar copings. Group A started the study with the standard bar (S-bar), while group B started with the attachment-bar (A-bar). After 3 months, they had to answer a questionnaire (visual analogue scale [VAS]); then the bar design was changed in both groups. After a period of another 3 months, the patients had to answer the same questions; then they had the choice to keep their preferred bar. Now the study period was extended to another year of observation, and the patients answered again the same questionnaire. In vivo force measurements were carried out with both bar types at the end of the test periods. The prosthetic maintenance service carried out during the 6-month period was recorded for both bar types in both groups. Statistical analysis as performed with the SPSS statistical package (SPSS Inc., Chicago, IL, USA). RESULTS: Satisfaction was high in both groups. Group B, who had entered the study with the attachment bar, gave slightly better ratings to this type for four items, while in group A, no differences were found. At the end of the 6-month comparison period, all but one patient wished to continue to wear the attachment bar. Prosthetic service was equal in groups A and B, but the total number of interventions is significantly higher in the attachment bar. Force patterns of maximum biting were similar in both bar designs, but exhibited significantly higher axial forces in the attachment bar. CONCLUSIONS: Both bar designs provide good retention and functional comfort. High stability appears to be an important factor for the patients' satisfaction and oral comfort. Rigid retention results in a higher force impact and appears to evoke the need for the retightening of occlusal screws, resulting in more maintenance service.
Resumo:
OBJECTIVE: Resonance frequency analysis (RFA) is a method of measuring implant stability. However, little is known about RFA of implants with long loading periods. The objective of the present study was to determine standard implant stability quotients (ISQs) for clinical successfully osseointegrated 1-stage implants in the edentulous mandible. MATERIALS AND METHODS: Stability measurements by means of RFA were performed in regularly followed patients who had received 1- stage implants for overdenture support. The time interval between implant placement and measurement ranged from 1 year up to 10 years. The short-term group comprised patients who were followed up to 5 years, while the long-term group included patients with an observation time of > 5 years up to 10 years. For further comparison RFA measurements were performed in a matching group with unloaded implants at the end of the surgical procedure. For statistical analysis various parameters that might influence the ISQs of loaded implants were included, and a mixed-effects model applied (regression analysis, P <.0125). RESULTS: Ninety-four patients were available with a total of 205 loaded implants, and 16 patients with 36 implants immediately after the surgical procedure. The mean ISQ of all measured implants was 64.5 +/- 7.9 (range, 58 to 72). Statistical analysis did not reveal significant differences in the mean ISQ related to the observation time. The parameters with overall statistical significance were the diameter of the implants and changes in the attachment level. In the short-term group, the gender and the clinically measured attachment level had a significant effect. Implant diameter had a significant effect in the long-term group. CONCLUSIONS: A mean ISQ of 64.5 +/- 7.9 was found to be representative for stable asymptomatic interforaminal implants measured by the RFA instrument at any given time point. No significant differences in ISQ values were found between implants with different postsurgical time intervals. Implant diameter appears to influence the ISQ of interforaminal implants.
Resumo:
AIMS: (i) To assess the pattern of early bacterial colonization on titanium oral implants after installation, at 12 weeks and at 12 months, (ii) to compare the microbiota at submucosal implant sites and adjacent subgingival tooth sites and (iii) to assess whether or not early colonization was predictive of 12-month colonization patterns. MATERIAL AND METHODS: Submucosal/subgingival plaque samples from 17 titanium oral implants and adjacent teeth were analyzed by checkerboard DNA-DNA hybridization 30 min, 12 weeks and 12 months after implant installation. RESULTS: At 12 months, none of the inserted implants had been lost or presented with signs of peri-implantitis. The distribution of sites at implants and teeth with bleeding on probing varied between 2% and 11%. Probing pocket depths < or =3 mm were found at 75% of implant sites. At 12 months, the sum of the bacterial counts of 40 species was statistically significantly higher at tooth compared with implant sites (mean difference: 34.4 x 10(5), 95% confidence interval -0.4 to 69.4, P<0.05). At 12 months, higher individual bacterial counts at tooth sites were found for 7/40 species compared with implant sites. Detection or lack of detection of Staphylococcus aureus at implant sites at 12 weeks resulted in the highest positive (e.g. 80%) and negative (e.g. 90%) predictive values, respectively. Between 12 weeks and 12 months, the prevalence of Tannerella forsythia increased statistically significantly at implant sites (P<0.05). Lack of detection of Porphyromonas gingivalis at 12 weeks yielded a negative predictive value of 93.1% of this microorganism being undetectable at implant sites at 12 months. CONCLUSIONS: Within the limits of this study, the findings showed (i) a few differences in the prevalence of bacterial species between implant and adjacent tooth sites at 12 months and (ii) high positive and negative predictive values for selected bacterial species.
Resumo:
OBJECTIVES: The objectives of this systematic review were to assess the survival rate of implants placed in sites with transalveolar sinus floor elevation. MATERIAL AND METHODS: An electronic search was conducted to identify prospective and retrospective cohort studies on transalveolar sinus floor elevation, with a mean follow-up time of at least 1 year after functional loading. Failure and complication rates were analyzed using random-effects Poisson regression models to obtain summary estimates/ year proportions. RESULTS: The search provided 849 titles. Full-text analysis was performed for 176 articles, resulting in 19 studies that met the inclusion criteria. Meta-analysis of these studies indicated an estimated annual failure rate of 2.48% (95% confidence interval (95% CI): 1.37-4.49%) translating to an estimated survival rate of 92.8% (95% CI): 87.4-96.0%) for implants placed in transalveolarly augmented sinuses, after 3 years in function. Furthermore, subject-based analysis revealed an estimated annual failure of 3.71% (95% CI: 1.21-11.38%), translating to 10.5% (95% CI: 3.6-28.9%) of the subjects experiencing implant loss over 3 years. CONCLUSION: Survival rates of implants placed in transalveolar sinus floor augmentation sites are comparable to those in non-augmented sites. This technique is predictable with a low incidence of complications during and post-operatively.
Resumo:
OBJECTIVES: The objectives of this systematic review were to assess the survival rate of grafts and implants placed with sinus floor elevation. MATERIAL AND METHODS: An electronic search was conducted to identify studies on sinus floor elevation, with a mean follow-up time of at least 1 year after functional loading. RESULTS: The search provided 839 titles. Full-text analysis was performed for 175 articles resulting in 48 studies that met the inclusion criteria, reporting on 12,020 implants. Meta-analysis indicated an estimated annual failure rate of 3.48% [95% confidence interval (CI): 2.48%-4.88%] translating into a 3-year implant survival of 90.1% (95% CI: 86.4%-92.8%). However, when failure rates was analyzed on the subject level, the estimated annual failure was 6.04% (95% CI: 3.87%-9.43%) translating into 16.6% (95% CI: 10.9%-24.6%) of the subjects experiencing implant loss over 3 years. CONCLUSION: The insertion of dental implants in combination with maxillary sinus floor elevation is a predictable treatment method showing high implant survival rates and low incidences of surgical complications. The best results (98.3% implant survival after 3 years) were obtained using rough surface implants with membrane coverage of the lateral window.
Resumo:
AIM: To evaluate the healing outcome of soft tissue dehiscence coverage at implant sites. MATERIAL AND METHODS: Ten patients with one mucosal recession defect at an implant site and a contralateral unrestored clinical crown without recession were recruited. The soft tissue recessions were surgically covered using a coronally advanced flap in combination with a free connective tissue graft. Healing was studied at 1, 3 and 6 months post-operatively. RESULTS: Soft tissue dehiscences were covered with a coronal overcompensation of the flap margin up to 1.2 mm after the procedure. After 1 month, the coverage shrank to a mean of 75%, after 3 months to 70% and after 6 months to 66%. CONCLUSIONS: The implant sites revealed a substantial, clinically significant improvement following coronal mucosal displacement in combination with connective tissue grafting, but in none of the sites, a could complete implant soft tissue dehiscence coverage be achieved.
Resumo:
In August 23-25, 2007, the Scandinavian Society for Prosthetic Dentistry in collaboration with the Danish Society of Oral Implantology arranged a consensus conference on the topic 'Implants and/or teeth'. It was preceded by a workshop in which eight focused questions were raised and answered in eight review articles using a systematic approach. Twenty-eight academicians and clinicians discussed the eight review papers with the purpose to reach consensus on questions relevant for the topic. At the conference the consensus statements were presented as well as lectures based on the review articles. In this article the methods used at the consensus workshop are briefly described followed by the statements with comments.
Resumo:
INTRODUCTION: The Nobel Direct implant (Nobel Biocare AB, Göteborg, Sweden) was developed to minimize marginal bone resorption and to result in "soft tissue integration" for an optimized aesthetic outcome. However, conflicting results have been presented in the literature. The aim of this present study was to evaluate the clinical and microbiologic outcomes of Nobel Direct implants. MATERIALS AND METHODS: Ten partially edentulous subjects without evidence of active periodontitis (mean age 55 years) received 12 Nobel Direct implants. Implants were loaded with single crowns after a healing period of 3 to 6 months. Treatment outcomes were assessed at month 24. Routine clinical assessments, intraoral radiographs, and microbiologic samplings were made. Histologic analysis of one failing implant and chemical spectroscopy around three unused implants was performed. Paired Wilcoxon signed-rank test was used for the evaluation of bone loss; otherwise, descriptive analysis was performed. RESULTS: Implants were functionally loaded after 3 to 6 months. At 2 years, the mean bone loss of remaining implants was 2.0 mm (SD +/- 1.1 mm; range: 0.0-3.4 mm). Three out of 12 implants with an early mean bone loss >3 mm were lost. The surviving implants showed increasing bone loss between 6 and 24 months (p = .028). Only 3 out of the 12 implants were considered successful and showed bone loss of <1.7 mm after 2 years. High rates of pathogens, including Aggregatibacter actinomycetemcomitans, Fusobacterium spp., Porphyromonas gingivalis, Pseudomonas aeruginosa, and Tanerella forsythia, were found. Chemical spectroscopy revealed, despite the normal signals from Ti, O, and C, also peaks of P, F, S, N, and Ca. A normal histologic image of osseointegration was observed in the apical part of the retrieved implant. CONCLUSION: Radiographic evidence and 25% implant failures are indications of a low success rate. High counts and prevalence of significant pathogens were found at surviving implants. Although extensive bone loss had occurred in the coronal part, the apical portion of the implant showed some bone to implant integration.
Resumo:
AIMS: To assess the impact of different implant systems on the clinical conditions and the microbiota at implants, and whether the presence of bacteria at tooth sites was predictive of the presence at implant sites. MATERIALS AND METHODS: Subjects with either AstraTech or Brånemark in function for 7 years were enrolled. Sub-gingival bacterial samples at tooth and implant sites were collected with sterile endodontic paper points, and analyzed by the checkerboard DNA-DNA hybridization method (40 species). RESULTS: Fifty-four subjects, 27 supplied with AstraTech (n=132 implants) and 27 with Brånemark (n=102) implants, were studied. Test tooth sites had significantly less evidence of bleeding on probing (P<0.001) and presence of plaque (P<0.001) than implant test sites. Implant sites presented with deeper probing pocket depth than tooth sites (mean difference: 1.1 mm, standard error of differences: 0.08, 95% confidence intervals (CI): 0.9-1.3, P<0.001). Tannerella forsythia (P<0.05), Capnocytophaga sputigena (P<0.05), Actinomyces israelii (P<0.05) and Lactobacillus acidophilus (P<0.05) were found at higher levels at tooth surfaces. No differences in bacterial load for any species were found between the two implant systems. The odds of being present/absent at tooth and implants sites were only significant for Staphylococcus aureus [odds ratio (OR): 5.2 : 1, 95% CI: 1.4-18.9, P<0.01]. CONCLUSIONS: After 7 years in function, implants presented with deeper probing depths than teeth. S. aureus was commonly present at both teeth and implants sites. S. aureus at tooth sites was predictive of also being present at implant sites.
Resumo:
Osseointegration of titanium dental implants into the jaw bone, which is required for maintenance of the implant in the jaw, results in ankylosis. Dental implants are therefore very unlike natural teeth, which exhibit significant movement in response to mechanical forces. The ability to generate periodontal ligament (PDL) tissues onto dental implants would better mimic the functional characteristics of natural teeth, and would likely improve implant duration and function. OBJECTIVES: The objective of this study was to investigate the feasibility of bioengineering PDL tissues onto titanium implant surfaces. METHODS: Bilateral maxillary first and second molars of 8-week old rats were extracted and used to generate single cell suspensions of PDL tissues, which were expanded in culture. Immunohistochemistry and RT-PCR were used to identify putative PDL progenitor/stem cell populations and characterize stem cell properties, including self-renewal, multipotency and stem cell maker expression. Cultured rPDL cells were harvested at third passage, seeded onto Matrigel-coated titanium implants (1.75 mm x 1 mm), and placed into healed M1/M2 extraction sites. Non-cell seeded Matrigel-coated titanium implants served as negative controls. Implants were harvested after 8, 12, or 18 weeks. RESULTS: Cultured rPDL cells expressed the mesenchymal stem-cell marker STRO-1. Under defined culture conditions, PDL cells differentiated into adipogenic, neurogenic and osteogenic lineages. While control implants were largely surrounded by alveolar bone, experimental samples exhibited fibrous PDL-like tissues, and perhaps cementum, on the surface of experimental implants. CONCLUSIONS: PDL contains stem cells that can generate cementum/PDL-like tissue in vivo. Transplantation of these cells might hold promise as a therapeutic approach for the bioengineering of PDL tissues onto titanium implant. Further refinement of this method will likely result in improved dental implant strategies for use of autologous PDL tissue regeneration in humans. This research was supported by CIMIT, and NIH/NIDCR grant DE016132 (PCY), and TEACRS (YL).