93 resultados para Mission pédagogique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In preparation for the Russian Luna-Resurs mission we combined our compact time-of-flight mass spectrometer (TOF-MS) with a chemical pre-separation of the species by gas chromatography (GC). Coupled measurements with both instruments were successfully performed with the prototype of the mass spectrometer and a flight-like gas chromatograph. The system was tested with two test gas mixtures, a mixture of hydrocarbons and a mixture of noble gases. Due to its capability to record mass spectra over the full mass range at once with high sensitivity and a dynamic range of up to 10(6) within 1 s, the TOF-MS system is a valuable extension of the GC analytical system. Based on the measurements with calibration gases performed with the combined GC-MS prototype and under assumption of mean characteristics for the Moon's regolith, the detection limit for volatile species in a soil sample is estimated to 2.10(-10) by mass for hydrocarbons and 2.10(-9) by mass for noble gases. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simple clinical scores to predict large vessel occlusion (LVO) in acute ischemic stroke would be helpful to triage patients in the prehospital phase. We assessed the ability of various combinations of National Institutes of Health Stroke Scale (NIHSS) subitems and published stroke scales (i.e., RACE scale, 3I-SS, sNIHSS-8, sNIHSS-5, sNIHSS-1, mNIHSS, a-NIHSS items profiles A-E, CPSS1, CPSS2, and CPSSS) to predict LVO on CT or MR arteriography in 1085 consecutive patients (39.4 % women, mean age 67.7 years) with anterior circulation strokes within 6 h of symptom onset. 657 patients (61 %) had an occlusion of the internal carotid artery or the M1/M2 segment of the middle cerebral artery. Best cut-off value of the total NIHSS score to predict LVO was 7 (PPV 84.2 %, sensitivity 81.0 %, specificity 76.6 %, NPV 72.4 %, ACC 79.3 %). Receiver operating characteristic curves of various combinations of NIHSS subitems and published scores were equally or less predictive to show LVO than the total NIHSS score. At intersection of sensitivity and specificity curves in all scores, at least 1/5 of patients with LVO were missed. Best odds ratios for LVO among NIHSS subitems were best gaze (9.6, 95 %-CI 6.765-13.632), visual fields (7.0, 95 %-CI 3.981-12.370), motor arms (7.6, 95 %-CI 5.589-10.204), and aphasia/neglect (7.1, 95 %-CI 5.352-9.492). There is a significant correlation between clinical scores based on the NIHSS score and LVO on arteriography. However, if clinically relevant thresholds are applied to the scores, a sizable number of LVOs are missed. Therefore, clinical scores cannot replace vessel imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the analysis of the lunar rocks and soil samples, brought to Earth by the Apollo missions, it is believed that the Moon has a waterless nature and also other volatile species are strongly depleted. Advancement in analysis techniques helped to identify water and other volatile species in lunar volcanic glasses. Additionally, recent lunar space missions detected water and volatile organic compounds in the region of the lunar poles where permanently shadowed craters are existing. All known lunar soil samples available on Earth come from the lunar near side, close to the equator. To verify the most recent measurement results and to enhance the knowledge of the geological history of the Moon it is of high interest to perform in situ measurements on the lunar poles. For this reason the Russian space agency, Roskosmos, developed aprogram for the scientific exploration of the lunar poles. The Gas Analysis Package (GAP) is part of the selected scientific payload aboard the Luna-Resurs Lander. This instrument uses pyrolytic cells and will apply laser spectroscopy, gas chromatography and mass spectrometry to detect and analyze volatile components trapped in the lunar soil. An existing ion optical design of a compact reflectron type time-of-flight mass spectrometer, originally built for the MEAP/P-BACE balloon mission, was chosen as a part of the GAP instrument. The scope of this thesis is the development of the interface between gas chromatography (GC) and this Neutral Gas Mass Spectrometer (NGMS) to perform coupled GC-MS measurements. In the first part of this thesis the interfacing concept was developed and verified by coupling the NGMS prototype to gas chromatography. The second part of this thesis is devoted to the development of the NGMS flight version.