179 resultados para Head Injuries
Resumo:
Osteoarthritis due to cranial cruciate ligament (CCL) rupture or hip dysplasia is one of the most important causes of chronic lameness in dogs. This study aimed at comparing nitric oxide (NO) production by the CCL with that of the femoral head ligament (FHL) and the medial collateral ligament (MCL), and investigating the pathway of NO production and the concomitant metalloproteinase (MMP) activity in the presence or absence of an inflammatory stimulus. Ligaments of normal dogs were subjected to different stimuli, and NO and MMP activity from explant culture supernatants were compared. The results showed that in explant cultures of the canine CCL more NO was produced than in those of the other two ligaments. A higher level of NO was produced when CCLs were exposed to the inducible nitric oxide synthase (iNOS)-inducing cocktail TNF/IL-1/LPS, and NO synthesis could be inhibited by both l-NMMA, a general nitric oxide synthase (NOS) inhibitor and l-NIL, a specific iNOS inhibitor. However, a correlation between NO synthesis and iNOS expression levels as determined by immunohistochemistry was not observed. In contrast to CCL, no evidence for iNOS-dependent NO synthesis was observed for MCL and FHL. The CCL produced less MMP than MCL and FHL, and no correlation between MMP and NO could be demonstrated. MMP activity in the CCL increased significantly after 48 h of incubation with the inflammatory stimulus. The results suggest that in canine osteoarthritis NO synthesized by canine CCL plays a more important role in the pathogenesis of osteoarthritis of the stifle than that synthesized by FHL and MCL.
Resumo:
The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump.
Resumo:
BACKGROUND: Mild traumatic brain injury (MTBI) defined as Glasgow Coma Scale (GCS) 14 or 15 has shown contradictory short- and long-term outcomes. The objective of this study was to correlate intra-cranial injuries (ICI) on CT scan to neurocognitive tests at admission and to complaints after 1 year. METHODS: Two hundred and five patients with MTBI underwent a CT scan and were examined with neurocognitive tests. After 1 year complaints were assessed by phone interviews. RESULTS: The neurocognitive tests in 51% of the patients showed significant deficits; there was no difference for patients with GCS 14-15, nor was there a difference between patients with ICI to patients without. After 1 year patients with ICI had significantly more complaints than patients without ICI, the most frequent complaint was headache and memory deficits. CONCLUSIONS: No correlation was found between GCS or ICI and the neurocognitive tests upon admission. After 1 year, patients with ICI have significantly more complaints than patients without ICI. No cost savings resulted by doing immediate CT scan on all.
Resumo:
The objective of the present study was to measure the occurrence of orofacial and cerebral injuries in different sports and to survey the awareness of athletes and officials concerning the use of mouthguards during sport activities. Two hundred and sixty-seven professional athletes and 63 officials participating in soccer, handball, basketball and ice hockey were interviewed. The frequency of orofacial and cerebral trauma during sport practice was recorded and the reason for using and not using mouthguards was assessed. A great difference in orofacial and cerebral injuries was found when comparing the different kinds of sports and comparing athletes with or without mouthguards. 45% of the players had suffered injuries when not wearing mouthguards. Most injuries were found in ice hockey, (59%), whereas only 24% of the soccer players suffered injuries when not wearing mouthguards. Sixty-eight percentage of the players wearing mouthguards had never suffered any orofacial and cerebral injuries. Two hundred and twenty-four athletes (84%) did not use a mouthguard despite general acceptance by 150 athletes (56%). Although the awareness of mouthguards among officials was very high (59%), only 25% of them would support the funding of mouthguards and 5% would enforce regulations. Athletes as well as coaches should be informed about the high risk of oral injuries when performing contact sports. Doctors and dentists need to recommend a more intensive education of students in sports medicine and sports dentistry, and to increase their willingness to become a team dentist.
Resumo:
Early radiographic detection of femoroacetabular impingement might prevent initiation and progression of osteoarthritis. The structural abnormality in femoral-induced femoroacetabular impingement (cam type) is frequently asphericity at the anterosuperior head/neck contour. To determine which of six radiographic projections (anteroposterior, Dunn, Dunn/45 degrees flexion, cross-table/15 degrees internal rotation, cross-table/neutral rotation, and cross-table/15 degrees external rotation) best identifies femoral head/neck asphericity, we studied 21 desiccated femurs; 11 with an aspherical femoral head/neck contour and 10 with a spherical femoral head/neck contour. To radiographically quantify femoral head asphericity, we measured the angle where the femoral head/neck leaves sphericity (angle alpha). The aspherical femoral head/neck contours had a greater maximum angle alpha (70 degrees ) compared with the spherical head/neck contours (50 degrees ). The angle alpha varied depending on the radiographic projection: it was greatest in the Dunn view with 45 degrees hip flexion (71 degrees +/- 10 degrees ) and least in the cross-table view in 15 degrees external rotation (51 degrees +/- 7 degrees ). Diagnosis of a pathologic femoral head/neck contour depends on the radiologic projection. The Dunn view in 45 degrees or 90 degrees flexion or a cross-table projection in internal rotation best show femoral head/neck asphericity, whereas anteroposterior or externally rotated cross-table views are likely to miss asphericity. Level of Evidence: Prognostic study, level II-1 (retrospective study).
Resumo:
The purpose of this study was to determine whether changes in glenoid version are associated with humeral head displacement and changes in the joint reaction forces, as these might contribute to instability or loosening in total shoulder replacement. A total shoulder prosthesis was implanted in neutral version in 6 cadaveric shoulders. Glenoid version was then changed in steps of 4 degrees toward more anteversion and retroversion. An increase in anteversion resulted in anterior translation of the humeral head and in eccentric loading of the anterior part of the glenoid. Retroversion was associated with posterior displacement and posterior loading of the glenoid. A change in rotation of the humeral component did not compensate for altered version of the glenoid component. These results suggest that both instability and glenoid component loosening may be related to the version of the glenoid component. Therefore, assessment of loosening and instability justifies precise assessment of glenoid component version.
Resumo:
This article reports about the internet based, second multicenter study (MCS II) of the spine study group (AG WS) of the German trauma association (DGU). It represents a continuation of the first study conducted between the years 1994 and 1996 (MCS I). For the purpose of one common, centralised data capture methodology, a newly developed internet-based data collection system ( http://www.memdoc.org ) of the Institute for Evaluative Research in Orthopaedic Surgery of the University of Bern was used. The aim of this first publication on the MCS II was to describe in detail the new method of data collection and the structure of the developed data base system, via internet. The goal of the study was the assessment of the current state of treatment for fresh traumatic injuries of the thoracolumbar spine in the German speaking part of Europe. For that reason, we intended to collect large number of cases and representative, valid information about the radiographic, clinical and subjective treatment outcomes. Thanks to the new study design of MCS II, not only the common surgical treatment concepts, but also the new and constantly broadening spectrum of spine surgery, i.e. vertebro-/kyphoplasty, computer assisted surgery and navigation, minimal-invasive, and endoscopic techniques, documented and evaluated. We present a first statistical overview and preliminary analysis of 18 centers from Germany and Austria that participated in MCS II. A real time data capture at source was made possible by the constant availability of the data collection system via internet access. Following the principle of an application service provider, software, questionnaires and validation routines are located on a central server, which is accessed from the periphery (hospitals) by means of standard Internet browsers. By that, costly and time consuming software installation and maintenance of local data repositories are avoided and, more importantly, cumbersome migration of data into one integrated database becomes obsolete. Finally, this set-up also replaces traditional systems wherein paper questionnaires were mailed to the central study office and entered by hand whereby incomplete or incorrect forms always represent a resource consuming problem and source of error. With the new study concept and the expanded inclusion criteria of MCS II 1, 251 case histories with admission and surgical data were collected. This remarkable number of interventions documented during 24 months represents an increase of 183% compared to the previously conducted MCS I. The concept and technical feasibility of the MEMdoc data collection system was proven, as the participants of the MCS II succeeded in collecting data ever published on the largest series of patients with spinal injuries treated within a 2 year period.
Resumo:
The purpose of this study was to evaluate the neuroimaging quality and accuracy of prospective real-time navigator-echo acquisition correction versus untriggered intrauterine magnetic resonance imaging (MRI) techniques. Twenty women in whom fetal motion artifacts compromised the neuroimaging quality of fetal MRI taken during the 28.7 +/- 4 week of pregnancy below diagnostic levels were additionally investigated using a navigator-triggered half-Fourier acquired single-shot turbo-spin echo (HASTE) sequence. Imaging quality was evaluated by two blinded readers applying a rating scale from 1 (not diagnostic) to 5 (excellent). Diagnostic criteria included depiction of the germinal matrix, grey and white matter, CSF, brain stem and cerebellum. Signal-difference-to-noise ratios (SDNRs) in the white matter and germinal zone were quantitatively evaluated. Imaging quality improved in 18/20 patients using the navigator echo technique (2.4 +/- 0.58 vs. 3.65 +/- 0.73 SD, p < 0.01 for all evaluation criteria). In 2/20 patients fetal movement severely impaired image quality in conventional and navigated HASTE. Navigator-echo imaging revealed additional structural brain abnormalities and confirmed diagnosis in 8/20 patients. The accuracy improved from 50% to 90%. Average SDNR increased from 0.7 +/- 7.27 to 19.83 +/- 15.71 (p < 0.01). Navigator-echo-based real-time triggering of fetal head movement is a reliable technique that can deliver diagnostic fetal MR image quality despite vigorous fetal movement.