112 resultados para GRASA ABDOMINAL
Resumo:
BACKGROUND The majority of radiological reports are lacking a standard structure. Even within a specialized area of radiology, each report has its individual structure with regards to details and order, often containing too much of non-relevant information the referring physician is not interested in. For gathering relevant clinical key parameters in an efficient way or to support long-term therapy monitoring, structured reporting might be advantageous. OBJECTIVE Despite of new technologies in medical information systems, medical reporting is still not dynamic. To improve the quality of communication in radiology reports, a new structured reporting system was developed for abdominal aortic aneurysms (AAA), intended to enhance professional communication by providing the pertinent clinical information in a predefined standard. METHODS Actual state analysis was performed within the departments of radiology and vascular surgery by developing a Technology Acceptance Model. The SWOT (strengths, weaknesses, opportunities, and threats) analysis focused on optimization of the radiology reporting of patients with AAA. Definition of clinical parameters was achieved by interviewing experienced clinicians in radiology and vascular surgery. For evaluation, a focus group (4 radiologists) looked at the reports of 16 patients. The usability and reliability of the method was validated in a real-world test environment in the field of radiology. RESULTS A Web-based application for radiological "structured reporting" (SR) was successfully standardized for AAA. Its organization comprises three main categories: characteristics of pathology and adjacent anatomy, measurements, and additional findings. Using different graphical widgets (eg, drop-down menus) in each category facilitate predefined data entries. Measurement parameters shown in a diagram can be defined for clinical monitoring and be adducted for quick adjudications. Figures for optional use to guide and standardize the reporting are embedded. Analysis of variance shows decreased average time required with SR to obtain a radiological report compared to free-text reporting (P=.0001). Questionnaire responses confirm a high acceptance rate by the user. CONCLUSIONS The new SR system may support efficient radiological reporting for initial diagnosis and follow-up for AAA. Perceived advantages of our SR platform are ease of use, which may lead to more accurate decision support. The new system is open to communicate not only with clinical partners but also with Radiology Information and Hospital Information Systems.
Resumo:
We present a case of a ruptured abdominal aortic aneurysm (AAA) with ambiguous accessory findings on post-mortem computed-tomography (PMCT), post-mortem magnetic resonance (PMMR) imaging, and PMCT-angiography (PMCTA) suggestive of thoracic aortic dissection. The diagnosis of ruptured AAA was confirmed by autopsy; however, there was no aortic dissection. The imaging findings that mimicked the presence of aortic dissection might have been an atypical presentation of post-mortem clotting or sedimentation. This case is an ideal example to illustrate benefits, limitations, and challenges of post-mortem cross-sectional imaging. It serves as a reminder that both, training as well as correlation of imaging findings with autopsy are fundamental to improve our understanding of radiologic findings on post-mortem cross-sectional imaging.
Resumo:
Accurate measurement of abdominal aortic aneurysms is necessary to predict rupture risk and, more recently, to follow aneurysm sac behavior following endovascular repair. Up until this point, aneurysm diameter has been the most common measurement utilized for these purposes. Although aneurysm diameter is predictive of rupture, accurate measurement is hindered by such factors as aortic tortuosity and interobserver variability, and it does not account for variations in morphology such as saccular aneurysms. Additionally, decreases in aneurysm diameter do not completely describe the somewhat complex remodeling seen following endovascular repair of aortic aneurysms. Measurement of aneurysm volume has the advantage of describing aneurysm morphology in a multidimensional fashion, but it has not been readily available or easily measured until recently. This has changed with the introduction of commercially available software tools that permit quicker and easier to perform volume measurements. Whether it is time for volume to replace, or compliment, diameter is the subject of the current debate.
Resumo:
Arterial waves are seen as possible independent mediators of cardiovascular risks, and the wave intensity analysis (WIA) has therefore been proposed as a method for patient selection for ventricular assist device (VAD) implantation. Interpreting measured wave intensity (WI) is challenging and complexity is increased by the implantation of a VAD. The waves generated by the VAD interact with the waves generated by the native heart, and this interaction varies with changing VAD settings. Eight sheep were implanted with a pulsatile VAD (PVAD) through ventriculo-aortic cannulation. The start of PVAD ejection was synchronized to the native R-wave and delayed between 0 % - 90 % of the cardiac cycle in 10 % steps or phase shifts (PS). Pressure and velocity signals were registered, using a combined Doppler and pressure wire positioned in the abdominal aorta, and used to calculate the WI. Depending on the PS, different wave interference phenomena occurred. Maximum unloading of the left ventricle (LV) coincided with constructive interference and maximum blood flow pulsatility, and maximum loading of the LV coincided with destructive interference and minimum blood flow pulsatility. We believe, that non-invasive WIA could potentially be used clinically to assess the mechanical load of the LV, and to monitor the peripheral hemodynamics such as blood flow pulsatility and risk of intestinal bleeding.
Resumo:
Coral reef aorta is a rare form of calcifying atherosclerosis typically involving the supra and juxtarenal aorta. P atients classically present with refractory hypertension, intermittent claudication and abdominal angina. The treatment is either surgical via transaortic endarterectomy or through transferal endovascular stentgraft placement. Here we describe the case of a 45yearold female patient infected with human immuno deficiency virus, with resistant hypertension, lower limb and abdominal claudication, who was successfully treated with endovascular stent placement. We f urther provide a brief overview of the disease characteristics and treatment options.
Resumo:
PURPOSE To determine the variability of apparent diffusion coefficient (ADC) values in various anatomic regions in the upper abdomen measured with magnetic resonance (MR) systems from different vendors and with different field strengths. MATERIALS AND METHODS Ten healthy men (mean age, 36.6 years ± 7.7 [standard deviation]) gave written informed consent to participate in this prospective ethics committee-approved study. Diffusion-weighted (DW) MR imaging was performed in each subject with 1.5- and 3.0-T MR systems from each of three vendors at two institutions. Two readers independently measured ADC values in seven upper abdominal regions (left and right liver lobe, gallbladder, pancreas, spleen, and renal cortex and medulla). ADC values were tested for interobserver differences, as well as for differences related to field strength and vendor, with repeated-measures analysis of variance; coefficients of variation (CVs) and variance components were calculated. RESULTS Interreader agreement was excellent (intraclass coefficient, 0.876). ADC values were (77.5-88.8) ×10(-5) mm(2)/sec in the spleen and (250.6-278.5) ×10(-5) mm(2)/sec in the gallbladder. There were no significant differences between ADC values measured at 1.5 T and those measured at 3.0 T in any anatomic region (P >.10 for all). In two of seven regions at 1.5 T (left and right liver lobes, P < .023) and in four of seven regions at 3.0 T (left liver lobe, pancreas, and renal cortex and medulla, P < .008), intervendor differences were significant. CVs ranged from 7.0% to 27.1% depending on the anatomic location. CONCLUSION Despite significant intervendor differences in ADC values of various anatomic regions of the upper abdomen, ADC values of the gallbladder, pancreas, spleen, and kidney may be comparable between MR systems from different vendors and between different field strengths.
Resumo:
AIMS In this work, we provide novel insight into the morphology of dissecting abdominal aortic aneurysms in angiotensin II-infused mice. We demonstrate why they exhibit a large variation in shape and, unlike their human counterparts, are located suprarenally rather than infrarenally. METHODS AND RESULTS We combined synchrotron-based, ultra-high resolution ex vivo imaging (phase contrast X-Ray tomographic microscopy) with in vivo imaging (high-frequency ultrasound and contrast-enhanced micro-CT) and image-guided histology. In all mice, we observed a tear in the tunica media of the abdominal aorta near the ostium of the celiac artery. Independently we found that, unlike the gradual luminal expansion typical for human aneurysms, the outer diameter increase of angiotensin II-induced dissecting aneurysms in mice was related to one or several intramural haematomas. These were caused by ruptures of the tunica media near the ostium of small suprarenal side branches, which had never been detected by the established small animal imaging techniques. The tear near the celiac artery led to apparent luminal dilatation, while the intramural haematoma led to a dissection of the tunica adventitia on the left suprarenal side of the aorta. The number of ruptured branches was higher in those aneurysms that extended into the thoracic aorta, which explained the observed variability in aneurysm shape. CONCLUSION Our results are the first to describe apparent luminal dilatation, suprarenal branch ruptures, and intramural haematoma formation in dissecting abdominal aortic aneurysms in mice. Moreover, we validate and demonstrate the vast potential of phase contrast X-ray tomographic microscopy in cardiovascular small animal applications.
Resumo:
OBJECTIVES To compare biomechanical rupture risk parameters of asymptomatic, symptomatic and ruptured abdominal aortic aneurysms (AAA) using finite element analysis (FEA). STUDY DESIGN Retrospective biomechanical single center analysis of asymptomatic, symptomatic, and ruptured AAAs. Comparison of biomechanical parameters from FEA. MATERIALS AND METHODS From 2011 to 2013 computed tomography angiography (CTA) data from 30 asymptomatic, 15 symptomatic, and 15 ruptured AAAs were collected consecutively. FEA was performed according to the successive steps of AAA vessel reconstruction, segmentation and finite element computation. Biomechanical parameters Peak Wall Rupture Risk Index (PWRI), Peak Wall Stress (PWS), and Rupture Risk Equivalent Diameter (RRED) were compared among the three subgroups. RESULTS PWRI differentiated between asymptomatic and symptomatic AAAs (p < .0004) better than PWS (p < .1453). PWRI-dependent RRED was higher in the symptomatic subgroup compared with the asymptomatic subgroup (p < .0004). Maximum AAA external diameters were comparable between the two groups (p < .1355). Ruptured AAAs showed the highest values for external diameter, total intraluminal thrombus volume, PWS, RRED, and PWRI compared with asymptomatic and symptomatic AAAs. In contrast with symptomatic and ruptured AAAs, none of the asymptomatic patients had a PWRI value >1.0. This threshold value might identify patients at imminent risk of rupture. CONCLUSIONS From different FEA derived parameters, PWRI distinguishes most precisely between asymptomatic and symptomatic AAAs. If elevated, this value may represent a negative prognostic factor for asymptomatic AAAs.
Resumo:
Echinococcus multilocularis is an important pathogenic zoonotic parasite of health concern, though absent in the United Kingdom. Eurasian beavers (Castor fiber) may act as a rare intermediate host, and so unscreened wild caught individuals may pose a potential risk of introducing this parasite to disease-free countries through translocation programs. There is currently no single definitive ante-mortem diagnostic test in intermediate hosts. An effective non-lethal diagnostic, feasible under field condition would be helpful to minimise parasite establishment risk, where indiscriminate culling is to be avoided. This study screened live beavers (captive, n = 18 or wild-trapped in Scotland, n = 12) and beaver cadavers (wild Scotland, n = 4 or Bavaria, n = 11), for the presence of E. multilocularis. Ultrasonography in combination with minimally invasive surgical examination of the abdomen by laparoscopy was viable under field conditions for real-time evaluation in beavers. Laparoscopy alone does not allow the operator to visualize the parenchyma of organs such as the liver, or inside the lumen of the gastrointestinal tract, hence the advantage of its combination with abdominal ultrasonography. All live beavers and Scottish cadavers were largely unremarkable in their haematology and serum biochemistry with no values suspicious for liver pathology or potentially indicative of E. multilocularis infection. This correlated well with ultrasound, laparoscopy, and immunoblotting, which were unremarkable in these individuals. Two wild Bavarian individuals were suspected E. multilocularis positive at post-mortem, through the presence of hepatic cysts. Sensitivity and specificity of a combination of laparoscopy and abdominal ultrasonography in the detection of parasitic liver cyst lesions was 100% in the subset of cadavers (95%Confidence Intervals 34.24-100%, and 86.7-100% respectively). For abdominal ultrasonography alone sensitivity was only 50% (95%CI 9.5-90.6%), with specificity being 100% (95%CI 79.2-100%). For laparoscopy alone sensitivity was 100% (95% CI 34.2-100%), with specificity also being 100% (95% CI 77.2-100%). Further immunoblotting, PCR and histopathological examination revealed one individual positive for E. multilocularis, whilst the other individual was positive for Taenia martis.
Resumo:
OBJECTIVES Human studies on the role of mannose-binding lectin (MBL) in patients with invasive candidiasis have yielded conflicting results. We investigated the influence of MBL and other lectin pathway proteins on Candida colonization and intra-abdominal candidiasis (IAC) in a cohort of high-risk patients. METHODS Prospective observational cohort study of 89 high-risk intensive-care unit (ICU) patients. Levels of lectin pathway proteins at study entry and six MBL2 single-nucleotide polymorphisms were analyzed by sandwich-type immunoassays and genotyping, respectively, and correlated with development of heavy Candida colonization (corrected colonization index (CCI) ≥0.4) and occurrence of IAC during a 4-week period. RESULTS Within 4 weeks after inclusion a CCI ≥0.4 and IAC was observed in 47% and 38% of patients respectively. Neither serum levels of MBL, ficolin-1, -2, -3, MASP-2 or collectin liver 1 nor MBL2 genotypes were associated with a CCI ≥0.4. Similarly, none of the analyzed proteins was found to be associated with IAC with the exception of lower MBL levels (HR 0.74, p = 0.02) at study entry. However, there was no association of MBL deficiency (<0.5 μg/ml), MBL2 haplo- or genotypes with IAC. CONCLUSION Lectin pathway protein levels and MBL2 genotype investigated in this study were not associated with heavy Candida colonization or IAC in a cohort of high-risk ICU patients.