209 resultados para Drug-eluting stent


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Preliminary results of a randomized trial have suggested that total lesion coverage with drug-eluting stents (DES) is not necessary in the presence of diffuse disease of nonuniform severity. In the present study, we report long-term results of this trial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives This study sought to compare the efficacy of passive stent coating with titanium-nitride-oxide (TiNO) with drug-eluting stents releasing zotarolimus (ZES) (Endeavor, Medtronic, Minneapolis, Minnesota). Background Stent coating with TiNO has been shown to reduce restenosis compared with bare-metal stents in experimental and clinical studies. Methods In an assessor-blind noninferiority study, 302 patients undergoing percutaneous coronary intervention were randomized to treatment with TiNO or ZES. The primary endpoint was in-stent late loss at 6 to 8 months, and analysis was by intention to treat. Results Both groups were well balanced with respect to baseline clinical and angiographic characteristics. The TiNO group failed to reach the pre-specified noninferiority margin for the primary endpoint (in-stent late loss: 0.64 ± 0.61 mm vs. 0.47 ± 0.48 mm, difference: 0.16, upper 1-sided 95% confidence interval [CI]: 0.26; pnoninferiority = 0.54), and subsequent superiority testing was in favor of ZES (psuperiority = 0.02). In-segment binary restenosis was lower with ZES (11.1%) than with TiNO (20.5%; psuperiority = 0.04). A stratified analysis of the primary endpoint found particularly pronounced differences between stents among diabetic versus nondiabetic patients (0.90 ± 0.69 mm vs. 0.39 ± 0.38 mm; pinteraction = 0.04). Clinical outcomes showed a similar rate of death (0.7% vs. 0.7%; p = 1.00), myocardial infarction (5.3% vs. 6.7%; p = 0.60), and major adverse cardiac events (21.1% vs. 18.0%, hazard ratio: 1.19, 95% CI: 0.71 to 2.00; p = 0.50) at 1 year. There were no differences in rates of definite or probable stent thrombosis (0.7% vs. 0%; p = 0.51) at 1 year. Conclusions Compared with TiNO, ZES was superior with regard to late loss and binary restenosis. The concept of passive stent coating with TiNO remains inferior to drug-eluting stent technology in reducing restenosis. ([TIDE] Randomized Trial Comparing Titan Stent With Zotarolimus-Eluting Stent: NCT00492908)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biolimus-eluting stents (BESs) with a biodegradable polymer in abluminal coating achieve more complete coverage at 9 months compared with sirolimus-eluting stents (SESs) with a durable polymer, as assessed by optical coherence tomography (OCT). Whether this advantage persists or augments after complete resorption of the polymer (>12 months) is unknown.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The SYNTAX score (SXscore) has been shown to be an effective predictor of clinical outcomes in patients undergoing percutaneous coronary intervention (PCI). Methods and results: The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the “all-comers” LEADERS trial (patients post-surgical revascularisation were excluded). Post hoc analysis was performed by stratifying clinical outcomes at two-year follow-up, according to one of three SXscore tertiles: SXlow ≤8 (n=464), 816 (n=461). At two-year follow-up the rate of major adverse cardiovascular events was 18.4%, 12.0% and 9.4% in the SXhigh, SXmid, and SXlow tertile, respectively (HR 1.45; CI 1.21-1.74; p<0.01). There was a significantly higher rate of cardiac death in patients in the highest SXscore tertile (7% SXhigh versus 2.4% SXmid versus 1.8% SXlow; HR 2.22; CI 1.5-3.27; p<0.001). Within the SXhigh tertile the rate of cardiac death was significantly lower in patients treated with the biolimus-eluting stent compared with the sirolimus-eluting stent (4.7% versus 9.6%, HR 0.48; CI 0.23-0.99; p=0.046). Conclusions: The SXscore when applied to an “all-comers” patient population allows for prospective risk stratification of patients undergoing PCI up to two years follow-up. In addition, the SXscore appears to separate the performance of devices in high risk patient groups.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an ‘all-comers' population of patients, in order to clarify the mechanism of eventual differences in the biocompatibility and thrombogenicity of the devices. Methods and results Patients randomized to angiographic follow-up in the RESOLUTE All Comers trial (NCT00617084) at pre-specified OCT sites underwent OCT follow-up at 13 months. Tissue coverage and apposition were assessed strut by strut, and the results in both treatment groups were compared using multilevel logistic or linear regression, as appropriate, with clustering at three different levels: patient, lesion, and stent. Fifty-eight patients (30 ZES and 28 EES), 72 lesions, 107 stents, and 23 197 struts were analysed. Eight hundred and eighty-seven and 654 uncovered struts (7.4 and 5.8%, P= 0.378), and 216 and 161 malapposed struts (1.8 and 1.4%, P= 0.569) were found in the ZES and EES groups, respectively. The mean thickness of coverage was 116 ± 99 µm in ZES and 142 ± 113 µm in EES (P= 0.466). No differences in per cent neointimal volume obstruction (12.5 ± 7.9 vs. 15.0 ± 10.7%) or other areas–volumetric parameters were found between ZES and EES, respectively. Conclusion No significant differences in tissue coverage, malapposition, or lumen/stent areas and volumes were detected by OCT between the hydrophilic polymer-coated ZES and the fluoropolymer-coated EES at 13-month follow-up.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to investigate the impact of patient and lesion complexity on outcomes with newer-generation zotarolimus-eluting stents (ZES) and everolimus-eluting stents (EES).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ABSORB cohort A trial using the bioresorbable everolimus-eluting scaffold (BVS revision 1.0, Abbott Vascular) demonstrated a slightly higher acute recoil with BVS than with metallic stents. To reinforce the mechanical strength of the scaffold, the new BVS scaffold (revision 1.1) with modified strut design was developed and tested in the ABSORB cohort B trial. This study sought to evaluate and compare the in vivo acute scaffold recoil of the BVS revision 1.0 in ABSORB cohort A and the BVS revision 1.1 in ABSORB cohort B with the historical recoil of the XIENCE V® everolimus-eluting metal stent (EES, SPIRIT I and II).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anemia is frequent among patients with cardiovascular disease and adversely affects prognosis. The objective of this analysis was to assess the impact of anemia on long-term clinical outcomes among patients undergoing percutaneous coronary intervention (PCI) with the unrestricted use of drug-eluting stents (DES).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goal of this study was to investigate sex-based differences in long-term clinical and angiographic outcomes after coronary revascularization with drug-eluting stents (DES).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate safety and effectiveness of early generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI), and to determine whether benefits and risks vary over time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Early generation drug-eluting stents (DESs) reduce restenosis and repeat revascularization procedures. However, the long-term safety and efficacy of early generation DES according to diabetic status are poorly established.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study investigated the efficacy and safety of a balloon expandable, sirolimus-eluting stent (SES) in patients with symptomatic infrapopliteal arterial disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

SPIRIT Women is the first interventional trial dedicated exclusively to women, focusing on symptoms at presentation, referral time to coronary intervention and the safety and performance of the XIENCE V stent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: This prospective multicenter study compared angiographic in-lesion late lumen loss in de novo native coronary artery lesions (vessel diameter range 2.25-2.75 mm, length range > or = 15 to < or = 30 mm) 8 months after the implantation of a sirolimus-eluting stent with that of similar vessels with the same drug-eluting stent or a bare stent of the SIRIUS study (historical controls). METHODS AND RESULTS: One hundred one patients (study group) were matched and compared with 323 patients receiving the bare stent (bare control group) and with 350 receiving the Cypher stent (Cypher control group) in the SIRIUS trial. Mean in-lesion late loss in the study group was lower than that in the bare control group (0.20 versus 0.76 mm, P < .0001) and not inferior to that in the Cypher control group (0.27 mm, P = .3). Adverse event rates (death and myocardial infarction) were similar between groups. At 8 months, target lesion revascularization rates were 0% in the study group, 13.2% in the bare control group (P < .001), and 4.6% in the Cypher control group (P = .03). CONCLUSIONS: The Cypher Bx Velocity stent was confirmed to be superior to the bare Bx Velocity stent in small coronary vessels in terms of in-lesion late loss 8 months after implantation.