216 resultados para Capsule anchor implantation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thrombosis of the inferior vena cava is a life-threatening complication in cancer patients leading to pulmonary embolism. These patients can also be affected by superior vena cava syndrome causing dyspnea followed by trunk or extremity swelling. We report the case of a 61-year-old female suffering from an extended colorectal tumor who became affected by both of the mentioned complications. Due to thrombus formation within the right vena jugularis interna, thrombosis of the inferior vena cava, and superior vena cava syndrome, a combined interventional procedure via a left jugular access with stenting of the superior vena cava and filter placement into the inferior vena cava was performed As a consequence, relief of the patient's symptoms, prevention of pulmonary embolism, and paving of the way for further venous chemotherapy were achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We assessed the impact of vessel size on angiographic and long-term clinical outcome after percutaneous coronary intervention (PCI) with sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES) within a randomized trial (SIRTAX [Sirolimus-Eluting Stent Compared With Paclitaxel-Eluting Stent for Coronary Revascularization]). BACKGROUND: Percutaneous coronary intervention in small-vessel disease is associated with an increased risk of major adverse cardiac events (MACE). METHODS: A total of 1,012 patients were randomly assigned to treatment with SES (n = 503) or PES (n = 509). A stratified analysis of angiographic and clinical outcome was performed up to 2 years after PCI according to size of the treated vessel (reference vessel diameter < or =2.75 vs. >2.75 mm). RESULTS: Of 1,012 patients, 370 patients (37%) with 495 lesions underwent stent implantation in small vessels only, 504 patients (50%) with 613 lesions in large vessels only, and 138 patients (14%) with 301 lesions in both small and large vessels (mixed). In patients with small-vessel stents, SES reduced MACE by 55% (10.4% vs. 21.4%; p = 0.004), mainly driven by a 69% reduction of target lesion revascularization (TLR) (6.0% vs. 17.7%; p = 0.001) compared with PES at 2 years. In patients with large- and mixed-vessel stents, rates of MACE (large: 10.4% vs. 13.1%; p = 0.33; mixed: 16.7% vs. 18.0%; p = 0.83) and TLR (large: 6.9% vs. 8.6%; p = 0.47; mixed: 16.7% vs. 15.4%; p = 0.86) were similar for SES and PES. There were no significant differences with respect to death and myocardial infarction between the 3 groups. CONCLUSIONS: Compared with PES, SES more effectively reduced MACE and TLR in small-vessel disease. Differences between SES and PES appear less pronounced in patients with large- and mixed-vessel disease. (The SIRTAX trial; http://clinicaltrials.gov/ct/show/NCT00297661?order=1; NCT00297661).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to investigate the biochemical properties, histological and immunohistochemical appearance, and magnetic resonance (MR) imaging findings of reparative cartilage after autologous chondrocyte implantation (ACI) for osteochondritis dissecans (OCD). METHODS: Six patients (mean age 20.2 +/- 8.8 years; 13-35 years) who underwent ACI for full-thickness cartilage defects of the femoral condyle were studied. One year after the procedure, a second-look arthroscopic operation was performed with biopsy of reparative tissue. The International Cartilage Repair Society (ICRS) visual histological assessment scale was used for histological assessment. Biopsied tissue was immunohistochemically analyzed with the use of monoclonal antihuman collagen type I and monoclonal antihuman collagen type II primary antibodies. Glycosaminoglycan (GAG) concentrations in biopsied reparative cartilage samples were measured by high performance liquid chromatography (HPLC). MR imaging was performed with T1- and T2-weighted imaging and three-dimensional spoiled gradient-recalled (3D-SPGR) MR imaging. RESULTS: Four tissue samples were graded as having a mixed morphology of hyaline and fibrocartilage while the other two were graded as fibrocartilage. Average ICRS scores for each criterion were (I) 1.0 +/- 1.5; (II) 1.7 +/- 0.5; (III) 0.6 +/- 1.0; (IV) 3.0 +/- 0.0; (V) 1.8 +/- 1.5; and (VI) 2.5 +/- 1.2. Average total score was 10.7 +/- 2.8. On immunohistochemical analysis, the matrix from deep and middle layers of reparative cartilage stained positive for type II collagen; however, the surface layer did not stain well. The average GAG concentration in reparative cartilage was 76.6 +/- 4.2 microg/mg whereas that in normal cartilage was 108 +/- 11.2 microg/mg. Common complications observed on 3D-SPGR MR imaging were hypertrophy of grafted periosteum, edema-like signal in bone marrow, and incomplete repair of subchondral bone at the surgical site. Clinically, patients had significant improvements in Lysholm scores. CONCLUSIONS: In spite of a good clinical course, reparative cartilage after ACI had less GAG concentration and was inferior to healthy hyaline cartilage in histological and immunohistochemical appearance and on MRI findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mesenchymal stem cells (MSCs) provide an important source of pluripotent cells for musculoskeletal tissue repair. This study examined the impact of MSC implantation on cartilage healing characteristics in a large animal model. Twelve full-thickness 15-mm cartilage lesions in the femoropatellar articulations of six young mature horses were repaired by injection of a self-polymerizing autogenous fibrin vehicle containing mesenchymal stem cells, or autogenous fibrin alone in control joints. Arthroscopic second look and defect biopsy was obtained at 30 days, and all animals were euthanized 8 months after repair. Cartilage repair tissue and surrounding cartilage were assessed by histology, histochemistry, collagen type I and type II immunohistochemistry, collagen type II in situ hybridization, and matrix biochemical assays. Arthroscopic scores for MSC-implanted defects were significantly improved at the 30-day arthroscopic assessment. Biopsy showed MSC-implanted defects contained increased fibrous tissue with several defects containing predominantly type II collagen. Long-term assessment revealed repair tissue filled grafted and control lesions at 8 months, with no significant difference between stem cell-treated and control defects. Collagen type II and proteoglycan content in MSC-implanted and control defects were similar. Mesenchymal stem cell grafts improved the early healing response, but did not significantly enhance the long-term histologic appearance or biochemical composition of full-thickness cartilage lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Stent thrombosis may occur late after drug-eluting stent (DES) implantation, and its cause remains unknown. The present study investigated differences of the stented segment between patients with and without very late stent thrombosis with the use of intravascular ultrasound. METHODS AND RESULTS: Since January 2004, patients presenting with very late stent thrombosis (> 1 year) after DES implantation underwent intravascular ultrasound. Findings in patients with very late stent thrombosis were compared with intravascular ultrasound routinely obtained 8 months after DES implantation in 144 control patients, who did not experience stent thrombosis for > or = 2 years. Very late stent thrombosis was encountered in 13 patients at a mean of 630+/-166 days after DES implantation. Compared with DES controls, patients with very late stent thrombosis had longer lesions (23.9+/-16.0 versus 13.3+/-7.9 mm; P<0.001) and stents (34.6+/-22.4 versus 18.6+/-9.5 mm; P<0.001), more stents per lesion (1.6+/-0.9 versus 1.1+/-0.4; P<0.001), and stent overlap (39% versus 8%; P<0.001). Vessel cross-sectional area was similar for the reference segment (cross-sectional area of the external elastic membrane: 18.9+/-6.9 versus 20.4+/-7.2 mm2; P=0.46) but significantly larger for the in-stent segment (28.6+/-11.9 versus 20.1+/-6.7 mm2; P=0.03) in very late stent thrombosis patients compared with DES controls. Incomplete stent apposition was more frequent (77% versus 12%; P<0.001) and maximal incomplete stent apposition area was larger (8.3+/-7.5 versus 4.0+/-3.8 mm2; P=0.03) in patients with very late stent thrombosis compared with controls. CONCLUSIONS: Incomplete stent apposition is highly prevalent in patients with very late stent thrombosis after DES implantation, suggesting a role in the pathogenesis of this adverse event.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Paclitaxel-eluting stents (PES) have been shown to reduce the rate of restenosis and the need for repeated revascularization procedures compared with bare metal stents. However, long-term effects of paclitaxel on vascular function are unknown. The purpose of the present study was to assess coronary vasomotor response to exercise after paclitaxel-eluting stent implantation. METHODS: Coronary vasomotion was evaluated by biplane quantitative coronary angiography at rest and during supine bicycle exercise in 27 patients with coronary artery disease. Twelve patients were treated with a bare metal stent (controls), and fifteen patients with a paclitaxel-eluting stent. All patients were restudied 6+/-2 (range 2-12) months after stent implantation. Minimal luminal diameter, stent diameter, proximal, distal and a reference vessel diameter were determined. RESULTS: Reference vessels showed exercise-induced vasodilation in both groups (+20+/-5% controls; +26+/-3% PES group). Vasomotion within the stented vessel segments was abolished. In the controls, the adjacent segments proximal and distal to the stent showed exercise-induced vasodilation (+17+/-3% and +24+/-4%). In contrast, there was exercise-induced vasoconstriction of the proximal and distal vessel segments adjacent to the paclitaxel-eluting stent (-13+/-6% and -18+/-4%; p<0.005). After sublingual nitroglycerin, the proximal and distal vessel segments dilated in both groups. Exercise-induced vasoconstriction adjacent to paclitaxel-eluting stent correlated inversely with the time interval after stent implantation. CONCLUSIONS: Paclitaxel-eluting stent implantation is associated with exercise-induced vasoconstriction in the persistent region suggesting endothelial dysfunction as the underlying mechanism. Improvement of vascular function occurs over time, indicating delayed vascular healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The polysaccharide capsule protects Streptococcus pneumoniae from phagocytosis during invasive infection, but inhibits adherence. Serotypes vary in their tendency to colonize the nasopharynx or cause invasive infection, and differences in capsule expression may play a role. Expression of the first gene of the capsule operon, cpsA, during in vitro growth of 43 clinical isolates representing 14 common pneumococcal serotypes was compared using quantitative RT-PCR. Serotypes associated with invasive infection (1, 4, 5, 7F, 8 and 14) expressed an average of twofold (P=0.0003) more cpsA than serotypes associated with nasopharyngeal colonization (6A, 6B, 9V, 15, 18C, 19F, 23F and 33). There was no difference in cpsA expression in response to growth under environmental oxygen or anaerobic conditions between the invasive and colonizing transparent strains tested: oxygen concentration did not affect cpsA expression in either the invasive or the colonizing transparent strains. Expression of cpsA at OD(600) 0.6 tended to be greater in strains with a longer lag phase during in vitro growth (P=0.07). Therefore, cpsA expression under ambient oxygen concentrations correlates with serotype-specific invasiveness and is inversely associated with the prevalence of serotype-specific carriage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, we showed that the in vitro lag phase correlates with the pneumococcal serotype. This study investigated the role of capsule genes in bacterial growth using strain D39. Deletion of the entire capsule operon induced a significantly prolonged lag phase in Todd Hewitt broth (P=0.0002). However, partial deletions showed a different influence on the lag phase. Supplementation of media with 5% fetal bovine serum restored normal growth, at least partially, in mutants with a prolonged lag phase. Therefore, pneumococcal capsule gene products influence bacterial growth in vitro in strain D39.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The epidemiology, phylogeny, and biology of nonencapsulated Streptococcus pneumoniae are largely unknown. Increased colonization capacity and transformability are, however, intriguing features of these pneumococci and play an important role. Twenty-seven nonencapsulated pneumococci were identified in a nationwide collection of 1,980 nasopharyngeal samples and 215 blood samples obtained between 1998 and 2002. On the basis of multilocus sequence typing and capsule region analysis we divided the nonencapsulated pneumococci into two groups. Group I was closely related to encapsulated strains. Group II had a clonal population structure, including two geographically widespread clones able to cause epidemic conjunctivitis and invasive diseases. Group II strains also carried a 1,959-bp homologue of aliB (aliB-like ORF 2) in the capsule region, which was highly homologous to a sequence in the capsule region of Streptococcus mitis. In addition, strains of the two major clones in group II had an additional sequence, aliB-like ORF 1 (1,968 to 2,004 bp), upstream of aliB-like ORF 2. Expression of aliB-like ORF 1 was detected by reverse transcription-PCR, and the corresponding RNA was visualized by Northern blotting. A gene fragment homologous to capN of serotypes 33 and 37 suggests that group II strains were derived from encapsulated pneumococci some time ago. Therefore, loss of capsule expression in vivo was found to be associated with the importation of one or two aliB homologues in some nonencapsulated pneumococci.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims Percutaneous coronary intervention (PCI) in diabetic patients is associated with an increased risk of restenosis and major adverse cardiac events (MACE). We assessed the impact of diabetes on long-term outcome after PCI with sirolimus-eluting (SES) and paclitaxel-eluting (PES) stents. Methods and results In the SIRTAX trial, 1012 patients were randomized to treatment with SES (n = 503) or PES (n = 509). A stratified analysis of outcomes was performed according to the presence or absence of diabetes. Baseline characteristics were well balanced between SES and PES in patients with (N = 201) and without diabetes (N = 811). Clinical outcome was worse in diabetic compared with non-diabetic patients regarding death (9.0% vs. 4.1%, P = 0.004) and MACE (defined as cardiac death, myocardial infarction, or TLR; 19.9% vs. 12.7%, P = 0.007) at 2 years. Among diabetic patients, SES reduced MACE by 47% (14.8% vs. 25.8%, HR = 0.52, P = 0.05) and TLR by 61% (7.4% vs. 17.2%, HR = 0.39, P = 0.03) compared with PES at 2 years. Conclusion Diabetic patients have worse prognosis than non-diabetic patients undergoing PCI with DES. Among the diabetic patient population of this trial, SES reduce repeat revascularization procedures and MACE more effectively than PES and to a similar degree as in non-diabetic patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: We sought to investigate the prevalence of posttraumatic stress disorder, anxiety, and depression in patients and their partners after implantation of a mechanical assist device as a bridge to heart transplantation. METHODS: This was a retrospective assessment of 41 patients (age 46.3 +/- 12.0 years; male-female ratio, 38:3; time since transplantation, 55.3 +/- 34.2 months [range, 7-122 months) and 27 partners (male-female ratio 2:25) by standardized instruments (Impact of Event Scale, Hospital Anxiety and Depression Scale), in 2 University Heart Transplant Centers (Vienna, Austria, Munster, Germany). The duration of the support systems (MicroMed DeBakey-VAD in 17 patients, Novacor in 10, Thoratec in 8, TCI HeartMate in 5, and Berlin Heart Incor in 1 patient) ranged from 28 to 711 (176 +/- 146) days. RESULTS: None of the patients, but 23% of the partners (n = 6), met the criteria for posttraumatic stress disorder (Maercker cutoff >0). The Impact of Event Scale (IES) sum scales differed significantly between the 2 groups (21.2 +/- 15.1, mean +/- SD) for the patients versus 38.1 +/- 27.8 for the partners, respectively; P = .001). Two percent of the patients, but 19% of the partners, showed mild to moderate depression; 4% of patients, but 23% of their partners, reported mild to moderate anxiety. None of the results were significantly influenced by the time since transplantation, patient age, diagnoses, type of assist device, or indication for heart transplantation. CONCLUSIONS: Despite patients being much closer to a life threat, their partners experience significantly more psychologic distress even in the long run. Our findings highlight the need for attention to the supporting persons.