148 resultados para Aneurysm
Resumo:
Microvascular surgery has become an important method for reconstructing surgical defects due to trauma, tumors or after burn. The most important factor for successful free flap transfer is a well-executed anastomosis. The time needed to perform the anastomosis and the failure rate are not negligible despite the high level of operator's experience. During the history, many alternatives were tried to help the microsurgeon and to reduce the complications. A Medline literature search was performed to find articles dealing with non-suture methods of microvascular anastomosis. Many historical books were also included. The non-suture techniques can be divided into four groups based on the used mechanism of sutures: double intubation including tubes and stents, intubation-eversion including simple rings, double eversion including staples and double rings, and wall adjustement with adhesives or laser. All these techniques were able to produce a faster and easier microvascular anastomosis. Nevertheless, disadvantages of the suturless techniques include toxicity, high cost, leakage or aneurysm formation. More refinement is needed before their widespread adoption. Thus, laser-assisted microvascular anastomosis using 1,9 μm diode laser appeared to be a safe and reliable help for the microsurgeon and may be further developed in the near future.
Resumo:
A 77-year-old woman underwent aortic valve replacement and coronary bypass grafting in 2007 in the Emirates. Evolution was uneventful until December 2011. After repeated episodes of unspecific infections, a computed tomographic scan showed a large pseudoaneurysm of the distal ascending aorta. The site of aortic rupture was closed with a Gore-Tex patch and a Staphylococcus aureus infection treated appropriately. Two months later, a small cutaneous lesion on the cranial part of the sternotomy started bleeding. Computed tomographic scan demonstrated recurrence of a false aneurysm with erosion of the sternum and a large subcutaneous hematoma caused by the fistula. The patient was transferred to our institution. The challenges of this case included safe surgical approach (sternotomy, cannulation, perfusion, cerebral protection) as well as complete removal and extensive debridement of the infected material and reconstruction of the aortic arch. Using fully biological material, reconstruction of the ascending aorta and proximal arch was successfully performed.
Resumo:
Time-of-flight (ToF) and phase contrast (PC) magnetic resonance angiographies (MRAs) are noninvasive applications to depict the cerebral arteries. Both approaches can image the cerebral vasculature without the administration of intravenous contrast. Therefore, it is used in routine clinical evaluation of cerebrovascular diseases, e.g., aneurysm and arteriovenous malformations. However, subtle microvascular disease usually cannot be resolved with standard, clinical-field-strength MRA. The purpose of this study was to compare the ability of ToF and PC MRA to visualize the cerebral arteries at increasing field strengths.
Resumo:
Vascular surgical training currently has to cope with various challenges, including restrictions on work hours, significant reduction of open surgical training cases in many countries, an increasing diversity of open and endovascular procedures, and distinct expectations by trainees. Even more important, patients and the public no longer accept a "learning by doing" training philosophy that leaves the learning curve on the patient's side. The Vascular International (VI) Foundation and School aims to overcome these obstacles by training conventional vascular and endovascular techniques before they are applied on patients. To achieve largely realistic training conditions, lifelike pulsatile models with exchangeable synthetic arterial inlays were created to practice carotid endarterectomy and patch plasty, open abdominal aortic aneurysm surgery, and peripheral bypass surgery, as well as for endovascular procedures, including endovascular aneurysm repair, thoracic endovascular aortic repair, peripheral balloon dilatation, and stenting. All models are equipped with a small pressure pump inside to create pulsatile flow conditions with variable peak pressures of ~90 mm Hg. The VI course schedule consists of a series of 2-hour modules teaching different open or endovascular procedures step-by-step in a standardized fashion. Trainees practice in pairs with continuous supervision and intensive advice provided by highly experienced vascular surgical trainers (trainer-to-trainee ratio is 1:4). Several evaluations of these courses show that tutor-assisted training on lifelike models in an educational-centered and motivated environment is associated with a significant increase of general and specific vascular surgical technical competence within a short period of time. Future studies should evaluate whether these benefits positively influence the future learning curve of vascular surgical trainees and clarify to what extent sophisticated models are useful to assess the level of technical skills of vascular surgical residents at national or international board examinations. This article gives an overview of our experiences of >20 years of practical training of beginners and advanced vascular surgeons using lifelike pulsatile vascular surgical training models.
Resumo:
OBJECTIVES: Aim of this study was to compare the utility of susceptibility weighted imaging (SWI) with the established diagnostic techniques CT and fluid attenuated inversion recovery (FLAIR) in their detecting capacity of subarachnoid hemorrhage (SAH), and further to compare the combined SWI/FLAIR MRI data with CT to evaluate whether MRI is more accurate than CT. METHODS: Twenty-five patients with acute SAH underwent CT and MRI within 6 days after symptom onset. Underlying pathology for SAH was head trauma (n=9), ruptured aneurysm (n=6), ruptured arteriovenous malformation (n=2), and spontaneous bleeding (n=8). SWI, FLAIR, and CT data were analyzed. The anatomical distribution of SAH was subdivided into 8 subarachnoid regions with three peripheral cisterns (frontal-parietal, temporal-occipital, sylvian), two central cisterns and spaces (interhemispheric, intraventricular), and the perimesencephalic, posterior fossa, superior cerebellar cisterns. RESULTS: SAH was detected in a total of 146 subarachnoid regions. CT identified 110 (75.3%), FLAIR 127 (87%), and SWI 129 (88.4%) involved regions. Combined FLAIR and SWI identified all 146 detectable regions (100%). FLAIR was sensitive for frontal-parietal, temporal-occipital and Sylvian cistern SAH, while SWI was particularly sensitive for interhemispheric and intraventricular hemorrhage. CONCLUSIONS: By combining SWI and FLAIR, MRI yields a distinctly higher detection rate for SAH than CT alone, particularly due to their complementary detection characteristics in different anatomical regions. Detection strength of SWI is high in central areas, whereas FLAIR shows a better detection rate in peripheral areas.
Resumo:
BACKGROUND AND PURPOSE:Conventional platinum coils cause imaging artifacts that reduce imaging quality and therefore impair imaging interpretation on intraprocedural or noninvasive follow-up imaging. The purpose of this study was to evaluate imaging characteristics and artifact production of polymeric coils compared with standard platinum coils in vitro and in vivo.MATERIALS AND METHODS:Polymeric coils and standard platinum coils were evaluated in vitro with the use of 2 identical silicon aneurysm models coiled with a packing attenuation of 20% each. DSA, flat panel CT, CT, and MR imaging were performed. In vivo evaluation of imaging characteristics of polymeric coils was performed in experimentally created rabbit carotid bifurcation aneurysms. DSA, CT/CTA, and MR imaging were performed after endovascular treatment of the aneurysms. Images were evaluated regarding visibility of individual coils, coil mass, artifact production, and visibility of residual flow within the aneurysm.RESULTS:Overall, in vitro and in vivo imaging showed relevantly reduced artifact production of polymeric coils in all imaging modalities compared with standard platinum coils. Image quality of CT and MR imaging was improved with the use of polymeric coils, which permitted enhanced depiction of individual coil loops and residual aneurysm lumen as well as the peri-aneurysmal area. Remarkably, CT images demonstrated considerably improved image quality with only minor artifacts compared with standard coils. On DSA, polymeric coils showed transparency and allowed visualization of superimposed vessel structures.CONCLUSIONS:This initial experimental study showed improved imaging quality with the use of polymeric coils compared with standard platinum coils in all imaging modalities. This might be advantageous for improved intraprocedural imaging for the detection of complications and posttreatment noninvasive follow-up imaging.
Resumo:
The rupture of intracranial aneurysms leads to subarachnoid hemorrhage, which is often associated with poor outcome. Preventive treatment of unruptured intracranial aneurysms is possible and recommended. However, the lack of candidate genes precludes identifying patients at risk by genetic analyses. We observed intracranial aneurysms in 2 patients with von Hippel-Lindau (VHL) disease and the known disease-causing mutation c.292T > C (p.Tyr98His) in the VHL tumor suppressor gene. This study investigates whether the VHL gene is a possible candidate gene for aneurysm formation.
Resumo:
In experimental aneurysm models, long-term patency without spontaneous thrombosis is the most important precondition for analyses of embolization devices. We recently reported the feasibility of creating complex venous pouch bifurcation aneurysms in the rabbit with low morbidity, low mortality, and high short-term aneurysm patency. In order to further evaluate our model, we examined the long-term patency rate.
Resumo:
Iatrogenic atrial septal defects are described in 2 patients. They occurred after implantation of Amplatzer occluders to close a patent foramen ovale. While device erosions to the extra-atrial space have been described, erosion induced atrial septal defects are a new medical entity. They may be fairly common in the situation of an atrial septal aneurysm whipping the rim of the device incessantly. They are clinically silent and benign and require echocardiography for detection. A second device solved the problem in the cases described.
Resumo:
Stroke is a significant cause of serious disability and death worldwide. A substantial proportion of strokes are related to an underlying cardiac embolic source, most commonly in association with atrial arrhythmias (fibrillation/flutter). Atrial fibrillation is considered a major risk factor for stroke. Although long-term prophylactic oral anticoagulation has been shown to be very effective in reducing stroke in patients with atrial fibrillation, it has a number of major limitations and is not feasible in all patients. In such cases, the use of percutaneously (transvenous) implanted left atrial appendage occlusive devices or surgical appendage obliteration is being explored. Similarly, the presence of a patent foramen ovale, especially in the presence of an atrial septal aneurysm, is now recognized as an important potential mediator of paradoxical cardiogenic embolism. Percutaneous patent foramen ovale closure is becoming increasingly established as a safe and effective means of preventing recurrent strokes in the presence of a patent foramen ovale. In this account, the authors discuss the intracardiac devices and techniques available and the relative merits of their use for stroke prevention.
Resumo:
Marfan's syndrome is caused by mutations in the extracellular matrix protein fibrillin-1 with aortic aneurysm and dissection being its most life-threatening manifestations. Kidney transplantation from donors with Marfan's syndrome has never been reported in the literature, possibly because of reticences due to the underlying connective tissue disease. Here, we report two patients with end-stage renal disease, transplanted with the kidneys from a donor with Marfan's syndrome who died of aortic dissection and cerebral hemorrhage. After delayed graft function in both recipients, renal function normalized with no renovascular complications and negative proteinuria for 6 years in one patient and 2 years in the other patient, who died from an ischemic cerebrovascular insult. Kidneys from organ donors with Marfan's syndrome might be suitable for transplantation.
Resumo:
Very recently, heterozygous mutations in the genes encoding transforming growth factor beta receptors I (TGFBR1) and II (TGFBR2) have been reported in Loeys-Dietz aortic aneurysm syndrome (LDS). In addition, dominant TGFBR2 mutations have been identified in Marfan syndrome type 2 (MFS2) and familial thoracic aortic aneurysms and dissections (TAAD). In the past, mutations of these genes were associated with atherosclerosis and several human cancers. Here, we report a total of nine novel and one known heterozygous sequence variants in the TGFBR1 and TGFBR2 genes in nine of 70 unrelated individuals with MFS-like phenotypes who previously tested negative for mutations in the gene encoding the extracellular matrix protein fibrillin-1 (FBN1). To assess the pathogenic impact of these sequence variants, in silico analyses were performed by the PolyPhen, SIFT, and Fold-X algorithms and by means of a 3D homology model of the TGFBR2 kinase domain. Our results showed that in all but one of the patients the pathogenic effect of at least one sequence variant is highly probable (c.722C > T, c.799A > C, and c.1460G > A in TGFBR1 and c.773T > G, c.1106G > T, c.1159G > A, c.1181G > A, and c.1561T > C in TGFBR2). These deleterious alleles occurred de novo or segregated with the disease in the families, indicating a causative association between the sequence variants and clinical phenotypes. Since TGFBR2 mutations found in patients with MFS-related disorders cannot be distinguished from heterozygous TGFBR2 mutations reported in tumor samples, we emphasize the importance of segregation analysis in affected families. In order to be able to find the mutation that is indeed responsible for a MFS-related phenotype, we also propose that genetic testing for sequence alterations in TGFBR1 and TGFBR2 should be complemented by mutation screening of the FBN1 gene.
Resumo:
We report of a 71-year-old woman with a history of chronic analgesic nephropathy, who underwent coronary angiography. Because of anterior ventricular aneurysm, anticoagulation with nadroparine was installed. Continued ACE-inhibitor and ASA with additional intravenous contrast substance lead to acute tubular necrosis with rapid decline of the renal function. Due to accumulation of the low molecular weight heparin, the patient developed an extensive retroperitoneal haematoma with circulatory shock and temporary anuric kidney failure. Low molecular weight heparins are commonly used during percutaneous coronary interventions. They are as safe and efficient compared to unfractioned heparin. But due to their renal elimination, they have to be monitored by measuring anti-factor Xa-activity if creatinine-clearance is <30 ml/min.
Resumo:
We describe the successful selective coil embolization of an infected superior gluteal pseudoaneurysm secondary to methicillin-resistant Staphylococcus aureus (MRSA) in a 36-year old women. The patient presented with a long history of drug abuse and perisacral abscesses due to chronic sacroilitis. The chosen strategy provides a safe and successful management of infected false gluteal artery aneurysm.
Resumo:
OBJECTIVES: To carry out long-term follow-up after percutaneous closure of patent foramen ovale (PFO) in patients with cryptogenic stroke. DESIGN: Prospective cohort study. SETTING: Single tertiary care centre. PARTICIPANTS: 525 consecutive patients (mean (SD) age 51 (12) years; 56% male). INTERVENTIONS: Percutaneous PFO closure without intraprocedural echocardiography. MAIN OUTCOME MEASURES: Freedom from recurrent embolic events. RESULTS: A mean (SD) of 1.7 (1.0) clinically apparent embolic events occurred for each patient, and 186 patients (35%) had >1 event. An atrial septal aneurysm was associated with the PFO in 161 patients (31%). All patients were followed up prospectively for up to 11 years. The implantation procedure failed in two patients (0.4%). There were 13 procedural complications (2.5%) without any long-term sequelae. Contrast transoesophageal echocardiography at 6 months showed complete closure in 86% of patients, and a minimal, moderate or large residual shunt in 9%, 3% and 2%, respectively. Patients with small occluders (<30 mm; n = 429) had fewer residual shunts (small 11% vs large 27%; p<0.001). During a mean (SD) follow-up of 2.9 (2.2) years (median 2.3 years; total 1534 patient-years), six ischaemic strokes, nine transient ischaemic attacks (TIAs) and two peripheral emboli occurred. Freedom from recurrent stroke, TIA, or peripheral embolism was 98% at 1 year, 97% at 2 years and 96% at 5 and 10 years, respectively. A residual shunt (hazard ratio = 3.4; 95% CI 1.3 to 9.2) was a risk factor for recurrence. CONCLUSIONS: This study attests to the long-term safety and efficacy of percutaneous PFO closure guided by fluoroscopy only for secondary prevention of paradoxical embolism in a large cohort of consecutive patients.