141 resultados para AK15-1364


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mesoscopic 3D imaging has become a widely used optical imaging technique to visualize intact biological specimens. Selective plane illumination microscopy (SPIM) visualizes samples up to a centimeter in size with micrometer resolution by 3D data stitching but is limited to fluorescent contrast. Optical projection tomography (OPT) works with fluorescent and nonfluorescent contrasts, but its resolution is limited in large samples. We present a hybrid setup (OPTiSPIM) combining the advantages of each technique. The combination of fluorescent and nonfluorescent high-resolution 3D data into integrated datasets enables a more extensive representation of mesoscopic biological samples. The modular concept of the OPTiSPIM facilitates incorporation of the transmission OPT modality into already established light sheet based imaging setups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fog is a potential source of water that could be exploited using the innovative technology of fog collection. Naturally, the potential of fog has proven its significance in cloud forests that are thriving from fog interception. Historically, the remains of artificial structures in different countries prove that fog has been collected as an alternative and/or supplementary water source. In the beginning of the 19th century, fog collection was investigated as a potential natural resource. After the mid-1980s, following success in Chile, fog-water collection commenced in a number of developing countries. Most of these countries are located in arid and semi-arid regions with topographic and climatic conditions that favour fog-water collection. This paper reviews the technology of fog collection with initial background information on natural fog collection and its historical development. It reviews the climatic and topographic features that dictate fog formation (mainly advection and orographic) and the innovative technology to collect it, focusing on the amount collected, the quality of fog water, and the impact of the technology on the livelihoods of beneficiary communities. By and large, the technology described is simple, cost-effective, and energy-free. However, fog-water collection has disadvantages in that it is seasonal, localised, and the technology needs continual maintenance. Based on the experience in several countries, the sustainability of the technology could be guaranteed if technical, economic, social, and management factors are addressed during its planning and implementation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We study the tuning curve of entangled photons generated by type-0 spontaneous parametric down-conversion in a periodically poled potassium titanyl phosphate crystal. We demonstrate the X-shaped spatiotemporal structure of the spectrum by means of measurements and numerical simulations. Experiments for different pump waists, crystal temperatures, and crystal lengths are in good agreement with numerical simulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We show that a single-layer antireflection coating on a THz source of high refractive index can substantially increase the transmission of emitted THz pulses. Calculations indicate that the optimum coating thickness depends on the exact shape of the generated THz waveform and whether the transmitted waveform is to be optimized for the highest peak (temporal) amplitude, peak spectral amplitude, or pulse energy. We experimentally demonstrate a 15% increase in peak amplitude, a 33% increase in peak spectral amplitude, and a 48% increase in energy for a 100 μm thick fused silica AR coating on a lithium niobate crystal used as THz emitter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Hemodynamic management in intensive care patients guided by blood pressure and flow measurements often do not sufficiently reveal common hemodynamic problems. Trans-esophageal echocardiography (TEE) allows for direct measurement of cardiac volumes and function. A new miniaturized probe for TEE (mTEE) potentially provides a rapid and simplified approach to monitor cardiac function. The aim of the study was to assess the feasibility of hemodynamic monitoring using mTEE in critically ill patients after a brief operator training period. METHODS In the context of the introduction of mTEE in a large ICU, 14 ICU staff specialists with no previous TEE experience received six hours of training as mTEE operators. The feasibility of mTEE and the quality of the obtained hemodynamic information were assessed. Three standard views were acquired in hemodynamically unstable patients: 1) for assessment of left ventricular function (LV) fractional area change (FAC) was obtained from a trans-gastric mid-esophageal short axis view, 2) right ventricular (RV) size was obtained from mid-esophageal four chamber view, and 3) superior vena cava collapsibility for detection of hypovolemia was assessed from mid-esophageal ascending aortic short axis view. Off-line blinded assessment by an expert cardiologist was considered as a reference. Inter-rater agreement was assessed using Chi-square tests or correlation analysis as appropriate. RESULTS In 55 patients, 148 mTEE examinations were performed. Acquisition of loops in sufficient quality was possible in 110 examinations for trans-gastric mid-esophageal short axis, 118 examinations for mid-esophageal four chamber and 125 examinations for mid-esophageal ascending aortic short axis view. Inter-rater agreement (Kappa) between ICU mTEE operators and the reference was 0.62 for estimates of LV function, 0.65 for RV dilatation, 0.76 for hypovolemia and 0.77 for occurrence of pericardial effusion (all P < 0.0001). There was a significant correlation between the FAC measured by ICU operators and the reference (r = 0.794, P (one-tailed) < 0.0001). CONCLUSIONS Echocardiographic examinations using mTEE after brief bed-side training were feasible and of sufficient quality in a majority of examined ICU patients with good inter-rater reliability between mTEE operators and an expert cardiologist. Further studies are required to assess the impact of hemodynamic monitoring by mTEE on relevant patient outcomes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The objective of this study was to evaluate the effects of two different mean arterial blood pressure (MAP) targets on needs for resuscitation, organ dysfunction, mitochondrial respiration and inflammatory response in a long-term model of fecal peritonitis. METHODS: Twenty-four anesthetized and mechanically ventilated pigs were randomly assigned (n = 8/group) to a septic control group (septic-CG) without resuscitation until death or one of two groups with resuscitation performed after 12 hours of untreated sepsis for 48 hours, targeting MAP 50-60 mmHg (low-MAP) or 75-85 mmHg (high-MAP). RESULTS: MAP at the end of resuscitation was 56 ± 13 mmHg (mean ± SD) and 76 ± 17 mmHg respectively, for low-MAP and high-MAP groups. One animal each in high- and low-MAP groups, and all animals in septic-CG died (median survival time: 21.8 hours, inter-quartile range: 16.3-27.5 hours). Norepinephrine was administered to all animals of the high-MAP group (0.38 (0.21-0.56) mcg/kg/min), and to three animals of the low-MAP group (0.00 (0.00-0.25) mcg/kg/min; P = 0.009). The high-MAP group had a more positive fluid balance (3.3 ± 1.0 mL/kg/h vs. 2.3 ± 0.7 mL/kg/h; P = 0.001). Inflammatory markers, skeletal muscle ATP content and hemodynamics other than MAP did not differ between low- and high-MAP groups. The incidence of acute kidney injury (AKI) after 12 hours of untreated sepsis was, respectively for low- and high-MAP groups, 50% (4/8) and 38% (3/8), and in the end of the study 57% (4/7) and 0% (P = 0.026). In septic-CG, maximal isolated skeletal muscle mitochondrial Complex I, State 3 respiration increased from 1357 ± 149 pmol/s/mg to 1822 ± 385 pmol/s/mg, (P = 0.020). In high- and low-MAP groups, permeabilized skeletal muscle fibers Complex IV-state 3 respiration increased during resuscitation (P = 0.003). CONCLUSIONS: The MAP targets during resuscitation did not alter the inflammatory response, nor affected skeletal muscle ATP content and mitochondrial respiration. While targeting a lower MAP was associated with increased incidence of AKI, targeting a higher MAP resulted in increased net positive fluid balance and vasopressor load during resuscitation. The long-term effects of different MAP targets need to be evaluated in further studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Definitions of shock and resuscitation endpoints traditionally focus on blood pressures and cardiac output. This carries a high risk of overemphasizing systemic hemodynamics at the cost of tissue perfusion. In line with novel shock definitions and evidence of the lack of a correlation between macro- and microcirculation in shock, we recommend that macrocirculatory resuscitation endpoints, particularly arterial and central venous pressure as well as cardiac output, be reconsidered. In this viewpoint article, we propose a three-step approach of resuscitation endpoints in shock of all origins. This approach targets only a minimum individual and context-sensitive mean arterial blood pressure (for example, 45 to 50 mm Hg) to preserve heart and brain perfusion. Further resuscitation is exclusively guided by endpoints of tissue perfusion irrespectively of the presence of arterial hypotension ('permissive hypotension'). Finally, optimization of individual tissue (for example, renal) perfusion is targeted. Prospective clinical studies are necessary to confirm the postulated benefits of targeting these resuscitation endpoints.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the universal prescription of sedative drugs in the intensive care unit (ICU), current practice is not guided by high-level evidence. Landmark sedation trials have made significant contributions to our understanding of the problems associated with ICU sedation and have promoted changes to current practice. We identified challenges and limitations of clinical trials which reduced the generalizability and the universal adoption of key interventions. We present an international perspective regarding current sedation practice and a blueprint for future research, which seeks to avoid known limitations and generate much-needed high-level evidence to better guide clinicians' management and therapeutic choices of sedative agents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ATLAS detector at the Large Hadron Collider is used to search for excited electrons and excited muons in the channel pp -> ll* -> ll gamma, assuming that excited leptons are produced via contact interactions. The analysis is based on 13 fb(-1) of pp collisions at a centre-of-mass energy of 8 TeV. No evidence for excited leptons is found, and a limit is set at the 95% credibility level on the cross section times branching ratio as a function of the excited-lepton mass m(l*). For m(l*) >= 0.8 TeV, the respective upper limits on sigma B(l(*) -> l gamma) are 0.75 and 0.90 fb for the e* and mu* searches. Limits on sigma B are converted into lower bounds on the compositeness scale 3. In the special case where Lambda = m(l*), excited-electron and excited-muon masses below 2.2 TeV are excluded.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Global environmental change includes changes in a wide range of global scale phenomena, which are expected to affect a number of physical processes, as well as the vulnerability of the communities that will experience their impact. Decision-makers are in need of tools that will enable them to assess the loss of such processes under different future scenarios and to design risk reduction strategies. In this paper, a tool is presented that can be used by a range of end-users (e.g. local authorities, decision makers, etc.) for the assessment of the monetary loss from future landslide events, with a particular focus on torrential processes. The toolbox includes three functions: a) enhancement of the post-event damage data collection process, b) assessment of monetary loss of future events and c) continuous updating and improvement of an existing vulnerability curve by adding data of recent events. All functions of the tool are demonstrated through examples of its application.