100 resultados para patient safety


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Drug-eluting stents (DESs) effectively reduce angiographic restenosis and the clinical need for repeat revascularization procedures as compared with bare-metal stents. Widely publicized concerns arose recently about the incidence of late and very late stent thrombosis with the use of first-generation DESs. Recent systematic reviews and large-scale registry studies demonstrated similar rates of overall mortality and myocardial infarction for patients treated with either DESs or bare-metal stents during long-term follow-up. Careful selection of stent type according to patient and lesion characteristics as well as monitoring of adherence to dual antiplatelet therapy could maximize the therapeutic potential of these devices. The purpose of the present Review is to provide the reader with an overview of the benefits and risks of first-generation DESs that could help physicians select the most appropriate stent type for each patient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Prolonged sacral neuromodulation (SNM) testing is more reliable for accurate patient selection than the usual test period of 4-7 days. However, prolonged testing was suspected to result in a higher complication rate due to infection via the percutaneous passage of the extension wire. Therefore, we prospectively assessed the complications associated with prolonged tined lead testing. PATIENTS AND METHODS: A consecutive series of 44 patients who underwent prolonged tined lead testing for at least 14 days between May 2002 and April 2007 were evaluated. Complications during prolonged tined lead testing, during and after tined lead explantation and during follow-up after implantation of the implantable pulse generator (IPG) were registered prospectively. RESULTS: Four patients suffered from urgency-frequency syndrome, 13 from urge incontinence, 18 from non-obstructive chronic urinary retention and nine from chronic pelvic pain syndrome. The median test phase was 30 days (interquartile range [IQR] 21-36). Thirty-two of the 44 patients (73%) had successful prolonged tined lead testing and 31 of these (97%) underwent the implantation of the IPG. The median follow-up of the IPG implanted patients was 31 months (IQR 20-41). The complication rate was 5% (2/44) during prolonged tined lead testing and 16% (5/31) during follow-up of the IPG implanted patients, respectively. None of the complications could be attributed to prolonged testing. No infections were observed during the study period. CONCLUSIONS: This prospective, observational non-randomised study suggests prolonged SNM tined lead testing is a safe procedure. Based on the low complication rate and the increased reliability for accurate patient selection, this method is proposed as a possible standard test procedure, subject to confirmation by further randomised, controlled clinical studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The off-label use of topical tacrolimus (Protopic) for inflammatory external eye diseases is gaining popularity. However, there are no reports on the safety profile of this new treatment option. PATIENTS AND METHODS: We treated six patients with different inflammatory eye diseases with topical tacrolimus (Protopic 0.03 %) as off-label use in addition to the conventional anti-inflammatory treatment. Patients were interviewed for side effects and serum drug concentrations were measured under steady state conditions one hour after topical application of tacrolimus ointment. RESULTS: Two patients reported a slight burning sensation immediately after application, in one patient we found a slight worsening of the dry eye problems. No patient abandoned the treatment due to side effects. Serum drug concentrations remained below the analytical threshold in all cases (< 1.5 ng/ml). CONCLUSIONS: Tacrolimus for the topical treatment of anterior segment inflammatory eye diseases is well tolerated without detectable systemic drug resorption.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Erythropoiesis-stimulating agents (ESAs) reduce anemia in cancer patients and may improve quality of life, but there are concerns that ESAs might increase mortality. OBJECTIVES: Our objectives were to examine the effect of ESAs and identify factors that modify the effects of ESAs on overall survival, progression free survival, thromboembolic and cardiovascular events as well as need for transfusions and other important safety and efficacy outcomes in cancer patients. SEARCH STRATEGY: We searched the Cochrane Library, Medline, Embase and conference proceedings for eligible trials. Manufacturers of ESAs were contacted to identify additional trials. SELECTION CRITERIA: We included randomized controlled trials comparing epoetin or darbepoetin plus red blood cell transfusions (as necessary) versus red blood cell transfusions (as necessary) alone, to prevent or treat anemia in adult or pediatric cancer patients with or without concurrent antineoplastic therapy. DATA COLLECTION AND ANALYSIS: We performed a meta-analysis of randomized controlled trials comparing epoetin alpha, epoetin beta or darbepoetin alpha plus red blood cell transfusions versus transfusion alone, for prophylaxis or therapy of anemia while or after receiving anti-cancer treatment. Patient-level data were obtained and analyzed by independent statisticians at two academic departments, using fixed-effects and random-effects meta-analysis. Analyses were according to the intention-to-treat principle. Primary endpoints were on study mortality and overall survival during the longest available follow-up, regardless of anticancer treatment, and in patients receiving chemotherapy. Tests for interactions were used to identify differences in effects of ESAs on mortality across pre-specified subgroups. The present review reports only the results for the primary endpoint. MAIN RESULTS: A total of 13933 cancer patients from 53 trials were analyzed, 1530 patients died on-study and 4993 overall. ESAs increased on study mortality (combined hazard ratio [cHR] 1.17; 95% CI 1.06-1.30) and worsened overall survival (cHR 1.06; 95% CI 1.00-1.12), with little heterogeneity between trials (I(2) 0%, p=0.87 and I(2) 7.1%, p=0.33, respectively). Thirty-eight trials enrolled 10441 patients receiving chemotherapy. The cHR for on study mortality was 1.10 (95% CI 0.98-1.24) and 1.04; 95% CI 0.97-1.11) for overall survival. There was little evidence for a difference between trials of patients receiving different cancer treatments (P for interaction=0.42). AUTHORS' CONCLUSIONS: ESA treatment in cancer patients increased on study mortality and worsened overall survival. For patients undergoing chemotherapy the increase was less pronounced, but an adverse effect could not be excluded.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: : Proton radiation has been used for the treatment of uveal melanoma since 1975, but few studies have been conducted to assess its efficacy and safety. This paper aims to systematically review the effects and side effects of proton therapy for any indication of the eye. MATERIAL AND METHODS: : A range of databases were searched from inception to 2007. All studies that included at least ten patients and that assessed the efficacy or safety of proton therapy for any indication of the eye were included. RESULTS: : The search generated 2,385 references, of which 37 met the inclusion criteria. Five controlled trials, two comparative studies and 30 case series were found, most often reporting on uveal melanoma, choroidal melanoma and age-related macular degeneration (AMD). Methodological quality of these studies was poor. Studies were characterized by large differences in radiation techniques applied within the studies, and by variation in patient characteristics within and between studies. Results for uveal melanoma and choroidal melanoma suggest favorable survival, with, however, significant rates of side effects. Results for choroidal hemangioma and AMD did not reveal beneficial effects from proton radiation. CONCLUSION: : There is limited evidence on the effectiveness and safety of proton radiation due to the lack of well-designed and well-reported studies. There is a need to lift evidence on proton therapy to a higher level by performing dose-finding randomized controlled trials (RCTs), comparative studies of proton radiation versus standard given alternatives and prospective case studies enrolling only patients treated with up-to-date techniques, allowing extrapolation of results to similar patient groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Interventional cardiology in a day-case setting might reduce logistic constraints on hospital resources. However, in contrast with coronary angioplasty, few data support the feasibility and safety of radiofrequency catheter ablation (RCA). The aim of this prospective, multicenter cohort study was to evaluate the feasibility and safety of RCA in 1,342 patients (814 men; mean age 57 +/- 17 years) considered eligible for ambulatory RCA, according to specific set of criteria, for common atrial flutter (n = 632), atrioventricular nodal reentrant tachycardia (n = 436), accessory pathways (n = 202), and atrial tachycardia (n = 72). Patients suitable for early discharge (4 to 6 hours after uncomplicated RCA) were scheduled for 1-month follow-up. Predictive factors for delayed complications were studied by multivariate analysis. Of the 1,342 enrolled patients, 1,270 (94.6%) were discharged the same day and followed for 1 month; no deaths occurred, and the readmission rate was 0.79% (95% confidence interval 0.30% to 1.27%). Six patients had significant puncture complications, 2 presented with symptomatic delayed pulmonary embolism, and 2 had new onset of poorly tolerated atrial flutter. None of these complications was life threatening. Multivariate analysis did not identify any significant independent predictors for delayed complications. In conclusion, these data suggest that same-day discharge after uncomplicated RCA for routine supraventricular arrhythmias is safe and may be applicable in clinical practice. This approach is known to be associated with significant patient satisfaction and cost savings and can be considered a first-line option in most patients who undergo routine ablation procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial. BACKGROUND The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES. METHODS The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat. RESULTS At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005). CONCLUSIONS The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Patients can make valuable contributions towards promoting the safety of their health care. Health care professionals (HCPs) could play an important role in encouraging patient involvement in safety-relevant behaviours. However, to date factors that determine HCPs' attitudes towards patient participation in this area remain largely unexplored. OBJECTIVE To investigate predictors of HCPs' attitudes towards patient involvement in safety-relevant behaviours. DESIGN A 22-item cross-sectional fractional factorial survey that assessed HCPs' attitudes towards patient involvement in relation to two error scenarios relating to hand hygiene and medication safety. SETTING Four hospitals in London PARTICIPANTS   Two hundred sixteen HCPs (116 doctors; 100 nurses) aged between 21 and 60 years (mean: 32): 129 female. OUTCOME MEASURES Approval of patient's behaviour, HCP response to the patient, anticipated effects on the patient-HCP relationship, support for being asked as a HCP, affective rating response to the vignettes. RESULTS HCPs elicited more favourable attitudes towards patients intervening about a medication error than about hand sanitation. Across vignettes and error scenarios, the strongest predictors of attitudes were how the patient intervened and how the HCP responded to the patient's behaviour. With regard to HCP characteristics, doctors viewed patients intervening less favourably than nurses. CONCLUSIONS HCPs perceive patients intervening about a potential error less favourably if the patient's behaviour is confrontational in nature or if the HCP responds to the patient intervening in a discouraging manner. In particular, if a HCP responds negatively to the patient (irrespective of whether an error actually occurred), this is perceived as having negative effects on the HCP-patient relationship.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Although well-established for suspected lower limb deep venous thrombosis, an algorithm combining a clinical decision score, d-dimer testing, and ultrasonography has not been evaluated for suspected upper extremity deep venous thrombosis (UEDVT). OBJECTIVE To assess the safety and feasibility of a new diagnostic algorithm in patients with clinically suspected UEDVT. DESIGN Diagnostic management study. (ClinicalTrials.gov: NCT01324037) SETTING: 16 hospitals in Europe and the United States. PATIENTS 406 inpatients and outpatients with suspected UEDVT. MEASUREMENTS The algorithm consisted of the sequential application of a clinical decision score, d-dimer testing, and ultrasonography. Patients were first categorized as likely or unlikely to have UEDVT; in those with an unlikely score and normal d-dimer levels, UEDVT was excluded. All other patients had (repeated) compression ultrasonography. The primary outcome was the 3-month incidence of symptomatic UEDVT and pulmonary embolism in patients with a normal diagnostic work-up. RESULTS The algorithm was feasible and completed in 390 of the 406 patients (96%). In 87 patients (21%), an unlikely score combined with normal d-dimer levels excluded UEDVT. Superficial venous thrombosis and UEDVT were diagnosed in 54 (13%) and 103 (25%) patients, respectively. All 249 patients with a normal diagnostic work-up, including those with protocol violations (n = 16), were followed for 3 months. One patient developed UEDVT during follow-up, for an overall failure rate of 0.4% (95% CI, 0.0% to 2.2%). LIMITATIONS This study was not powered to show the safety of the substrategies. d-Dimer testing was done locally. CONCLUSION The combination of a clinical decision score, d-dimer testing, and ultrasonography can safely and effectively exclude UEDVT. If confirmed by other studies, this algorithm has potential as a standard approach to suspected UEDVT. PRIMARY FUNDING SOURCE None.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: We assessed the safety of the multikinase inhibitor regorafenib in patients with hepatocellular carcinoma (HCC) that had progressed following first-line sorafenib. PATIENTS AND METHODS: Thirty-six patients with Barcelona Clinic Liver Cancer stage B or C HCC and preserved to mildly impaired liver function (Child-Pugh class A) received regorafenib 160 mg once daily in cycles of 3 weeks on/1 week off treatment until disease progression, unacceptable toxicity, death or patient/physician decision to discontinue. The primary end-point was safety; secondary end-points included efficacy (including time to progression and overall survival). RESULTS: The median treatment duration was 19.5 weeks (range 2-103). At data cutoff, three patients remained on treatment. Reasons for discontinuation were adverse events (n=20), disease progression (n=10), consent withdrawal (n=2) and death (n=1). Seventeen patients required dose reductions (mostly for adverse events [n=15]); 35 patients had treatment interruption (mostly for adverse events [n=32] or patient error [n=11]). The most frequent treatment-related adverse events were hand-foot skin reaction (any grade n=19; grade ≥3 n=5), diarrhoea (n=19; n=2), fatigue (n=19; n=6), hypothyroidism (n=15; n=0), anorexia (n=13; n=0), hypertension (n=13; n=1), nausea (n=12; n=0) and voice changes (n=10; n=0). Disease control was achieved in 26 patients (partial response n=1; stable disease n=25). Median time to progression was 4.3 months. Median overall survival was 13.8 months. CONCLUSION: Regorafenib had acceptable tolerability and evidence of antitumour activity in patients with intermediate or advanced HCC that progressed following first-line sorafenib.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Renal impairment (RI) is associated with impaired prognosis in patients with coronary artery disease. Clinical and angiographic outcomes of patients undergoing percutaneous coronary intervention (PCI) with the use of drug-eluting stents (DES) in this patient population are not well established. METHODS We pooled individual data for 5,011 patients from 3 trials with the exclusive and unrestricted use of DES (SIRTAX - N = 1,012, LEADERS - N = 1,707, RESOLUTE AC - N = 2,292). Angiographic follow-up was available for 1,544 lesions. Outcomes through 2 years were stratified according to glomerular filtration rate (normal renal function: GFR≥90 ml/min; mild RI: 90Patients with moderate/severe RI had an increased risk of cardiac death or myocardial infarction ([MI], OR 2.14, 95%CI 1.36-3.36), cardiac death (OR 2.21, 95%CI 1.10-4.46), and MI (OR 2.02, 95%CI 1.19-3.43) compared with patients with normal renal function at 2 years follow-up. There was no difference in cardiac death or MI between patients with mild RI compared to those with normal renal function (OR 1.10, 95%CI 0.75-1.61). The risk of target-lesion revascularization was similar for patients with moderate/severe RI (OR 1.17, 95%CI 0.70-1.95) and mild RI (OR 1.16, 95%CI 0.81-1.64) compared with patients with normal renal function. In-stent late loss and in-segment restenosis were not different for patients with moderate/severe RI, mild RI, and normal renal function. CONCLUSIONS Renal function does not affect clinical and angiographic effectiveness of DES. However, prognosis remains impaired among patients with moderate/severe RI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Opioid substitution treatment (OST) for opioid dependence may be limited by adverse events (AEs). Increasing the range of therapeutic options optimizes outcomes and facilitates patient management. An international, multi-center, two-phase study investigated the efficacy and safety of slow-release oral morphine (SROM) versus methadone in patients receiving methadone therapy for opioid dependence. In phase 1 (two way cross-over, 11 weeks each period) patients were randomized to SROM or methadone oral solution. In phase 2 (25 weeks), patients continued treatment with SROM (group A) or switched from methadone to SROM (group B). In total, 211 out of 276 completed phase 1 and 198 entered phase 2 (n = 95 group A, n = 103 group B). Treatment with both SROM and methadone was well tolerated. However, the mean QTc-interval associated with methadone was significantly longer than that under SROM. Higher treatment satisfaction, fewer cravings for heroin, and lower mental stress were reported with SROM. This study adds a significant further weight of evidence that SROM is an effective and well tolerated long-term maintenance treatment for opioid dependence with a beneficial risk profile compared to methadone regarding cardiac effects and supports its clinical utility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Extensive coronary artery disease (CAD) is associated with higher risk. In this substudy of the PLATO trial, we examined the effects of randomized treatment on outcome events and safety in relation to the extent of CAD. METHODS Patients were classified according to presence of extensive CAD (defined as 3-vessel disease, left main disease, or prior coronary artery bypass graft surgery). The trial's primary and secondary end points were compared using Cox proportional hazards regression. RESULTS Among 15,388 study patients for whom the extent of CAD was known, 4,646 (30%) had extensive CAD. Patients with extensive CAD had more high-risk characteristics and experienced more clinical events during follow-up. They were less likely to undergo percutaneous coronary intervention (58% vs 79%, P < .001) but more likely to undergo coronary artery bypass graft surgery (16% vs 2%, P < .001). Ticagrelor, compared with clopidogrel, reduced the composite of cardiovascular death, myocardial infarction, and stroke in patients with extensive CAD (14.9% vs 17.6%, hazard ratio [HR] 0.85 [0.73-0.98]) similar to its reduction in those without extensive CAD (6.8% vs 8.0%, HR 0.85 [0.74-0.98], Pinteraction = .99). Major bleeding was similar with ticagrelor vs clopidogrel among patients with (25.7% vs 25.5%, HR 1.02 [0.90-1.15]) and without (7.3% vs 6.4%, HR 1.14 [0.98-1.33], Pinteraction = .24) extensive CAD. CONCLUSIONS Patients with extensive CAD have higher rates of recurrent cardiovascular events and bleeding. Ticagrelor reduced ischemic events to a similar extent both in patients with and without extensive CAD, with bleeding rates similar to clopidogrel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Antifibrinolytics have been used for 2 decades to reduce bleeding in cardiac surgery. MDCO-2010 is a novel, synthetic, serine protease inhibitor. We describe the first experience with this drug in patients. METHODS In this phase II, double-blind, placebo-controlled study, 32 patients undergoing isolated primary coronary artery bypass grafting with cardiopulmonary bypass were randomly assigned to 1 of 5 increasing dosage groups of MDCO-2010. The primary aim was to evaluate pharmacokinetics (PK) with assessment of plasmatic concentrations of the drug, short-term safety, and tolerance of MDCO-2010. Secondary end points were influence on coagulation, chest tube drainage, and transfusion requirements. RESULTS PK analysis showed linear dosage-proportional correlation between MDCO-2010 infusion rate and PK parameters. Blood loss was significantly reduced in the 3 highest dosage groups compared with control (P = 0.002, 0.004 and 0.011, respectively). The incidence of allogeneic blood product transfusions was lower with MDCO-2010 4/24 (17%) vs 4/8 (50%) in the control group. MDCO-2010 exhibited dosage-dependent antifibrinolytic effects through suppression of D-dimer generation and inhibition of tissue plasminogen activator-induced lysis in ROTEM analysis as well as anticoagulant effects demonstrated by prolongation of activated clotting time and activated partial thromboplastin time. No systematic differences in markers of end organ function were observed among treatment groups. Three patients in the MDCO-2010 groups experienced serious adverse events. One patient experienced intraoperative thrombosis of venous grafts considered possibly related to the study drug. No reexploration for mediastinal bleeding was required, and there were no deaths. CONCLUSIONS This first-in-patient study demonstrated dosage-proportional PK for MDCO-2010 and reduction of chest tube drainage and transfusions in patients undergoing primary coronary artery bypass grafting. Antifibrinolytic and anticoagulant effects were demonstrated using various markers of coagulation. MDCO-2010 was well tolerated and showed an acceptable initial safety profile. Larger multi-institutional studies are warranted to further investigate the safety and efficacy of this compound.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE, AIMS AND OBJECTIVES Safety climate measurements are a broadly used element of improvement initiatives. In order to provide a sound and easy-to-administer instrument for the use in Swiss hospitals, we translated the Safety Climate Survey into German and French. METHODS After translating the Safety Climate Survey into French and German, a cross-sectional survey study was conducted with health care professionals (HCPs) in operating room (OR) teams and on OR-related wards in 10 Swiss hospitals. Validity of the instrument was examined by means of Cronbach's alpha and missing rates of the single items. Item-descriptive statistics group differences and percentage of 'problematic responses' (PPR) were calculated. RESULTS 3153 HCPs completed the survey (response rate: 63.4%). 1308 individuals were excluded from the analyses because of a profession other than doctor or nurse or invalid answers (n = 1845; nurses = 1321, doctors = 523). Internal consistency of the translated Safety Climate Survey was good (Cronbach's alpha G erman  = 0.86; Cronbach's alpha F rench  = 0.84). Missing rates at item level were rather low (0.23-4.3%). We found significant group differences in safety climate values regarding profession, managerial function, work area and time spent in direct patient care. At item level, 14 out of 21 items showed a PPR higher than 10%. CONCLUSIONS Results indicate that the French and German translations of the Safety Climate Survey might be a useful measurement instrument for safety climate in Swiss hospital units. Analyses at item level allow for differentiating facets of safety climate into more positive and critical safety climate aspects.