92 resultados para misfit dislocation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Data concerning outcome after management of acetabular fractures by anterior approaches with focus on age and fractures associated with roof impaction, central dislocation and/or quadrilateral plate displacement are rare. METHODS Between October 2005 and April 2009 a series of 59 patients (mean age 57 years, range 13-91) with fractures involving the anterior column was treated using the modified Stoppa approach alone or for reduction of displaced iliac wing or low anterior column fractures in combination with the 1st window of the ilioinguinal approach or the modified Smith-Petersen approach, respectively. Surgical data, accuracy of reduction, clinical and radiographic outcome at mid-term and the need for endoprosthetic replacement in the postoperative course (defined as failure) were assessed; uni- and multivariate regression analysis were performed to identify independent predictive factors (e.g. age, nonanatomical reduction, acetabular roof impaction, central dislocation, quadrilateral plate displacement) for a failure. Outcome was assessed for all patients in general and in accordance to age in particular; patients were subdivided into two groups according to their age (group "<60yrs", group "≥60yrs"). RESULTS Forty-three of 59 patients (mean age 54yrs, 13-89) were available for evaluation. Of these, anatomic reduction was achieved in 72% of cases. Nonanatomical reduction was identified as being the only multivariate predictor for subsequent total hip replacement (Adjusted Hazard Ratio 23.5; p<0.01). A statistically significant higher rate of nonanatomical reduction was observed in the presence of acetabular roof impaction (p=0.01). In 16% of all patients, total hip replacement was performed and in 69% of patients with preserved hips the clinical results were excellent or good at a mean follow up of 35±10 months (range: 24-55). No statistical significant differences were observed between both groups. CONCLUSION Nonanatomical reconstruction of the articular surfaces is at risk for failure of joint-preserving management of acetabular fractures through an isolated or combined modified Stoppa approach resulting in total joint replacement at mid-term. In the elderly, joint-preserving surgery is worth considering as promising clinical and radiographic results might be obtained at mid-term.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE The purpose of this study was to evaluate if osseous correction of the femoral neck achieved arthroscopically is comparable to that achieved by surgical dislocation. METHODS We retrospectively analyzed all patients who were treated with hip arthroscopy or surgical dislocation for cam or mixed type femoroacetabular impingement (FAI) in our institution between 2006 and 2009. Inclusion criteria were complete clinical and radiologic documentation with standardized radiographs. Group 1 consisted of 66 patients (49 female patients, mean age 33.8 years) treated with hip arthroscopy. Group 2 consisted of 135 patients (91 male patients, mean age 31.2 years) treated with surgical hip dislocation. We compared the preoperative and postoperative alpha and gamma angles, as well as the triangular index. Mean follow-up was 16.7 months (range, 2 to 79 months). RESULTS In group 1, the mean alpha angle improved from 60.7° preoperatively to 47.8° postoperatively (P < .001) and the mean gamma angle improved from 47.3° to 44.5° (P < .001). Over time, the preoperative mean alpha angle increased from 56.3° in 2006 to 67.5° in 2009, whereas the postoperative mean alpha angle decreased from 51.2° in 2006 to 47.5° in 2009. In group 2, the mean alpha angle improved from 75.3° preoperatively to 44.8° postoperatively (P < .001), and the mean gamma angle improved from 65.1° to 52.2° (P < .001). Arthroscopic revision of intra-articular adhesions was performed in 4 patients (6.1%) in group 1 and 16 patients (12%) in group 2. Three patients (2.2%) in group 2 underwent revision for nonunion of the greater trochanter. CONCLUSIONS Osseous correction of cam-type FAI with hip arthroscopy is comparable to the correction achieved by surgical hip dislocation. There is a significant learning curve for hip arthroscopy, with postoperative osseous correction showing improved results with increasing surgical experience. LEVEL OF EVIDENCE Level III, retrospective comparative study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To compare the precision of fit of full-arch implant-supported screw-retained computer-aided designed and computer-aided manufactured (CAD/CAM) titanium-fixed dental prostheses (FDP) before and after veneering. The null-hypothesis was that there is no difference in vertical microgap values between pure titanium frameworks and FDPs after porcelain firing. MATERIALS AND METHODS Five CAD/CAM titanium grade IV frameworks for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI tooth positions 15, 13, 11, 21, 23, 25) were fabricated after digitizing the implant platforms and the cuspid-supporting framework resin pattern with a laser scanner (CARES(®) Scan CS2; Institut Straumann AG, Basel, Switzerland). A bonder, an opaquer, three layers of porcelain, and one layer of glaze were applied (Vita Titankeramik) and fired according to the manufacturer's preheating and fire cycle instructions at 400-800°C. The one-screw test (implant 25 screw-retained) was applied before and after veneering of the FDPs to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from interproximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS All vertical microgaps were clinically acceptable with values <90 μm. No statistically significant pairwise difference (P = 0.98) was observed between the relative effects of vertical microgap of unveneered (median 19 μm; 95% CI 13-35 μm) and veneered FDPs (20 μm; 13-31 μm), providing support for the null-hypothesis. Analysis within the groups showed significantly different values between the five implants of the FDPs before (P = 0.044) and after veneering (P = 0.020), while a monotonous trend of increasing values from implant 23 (closest position to screw-retained implant 25) to 15 (most distant implant) could not be observed (P = 0.169, P = 0.270). CONCLUSIONS Full-arch CAD/CAM titanium screw-retained frameworks have a high accuracy. Porcelain firing procedure had no impact on the precision of fit of the final FDPs. All implant microgap measurements of each FDP showed clinically acceptable vertical misfit values before and after veneering. Thus, the results do not only show accurate performance of the milling and firing but show also a reproducible scanning and designing process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Posterior approaches to the hip joint were developed by Langenbeck and Kocher in the nineteenth century. Letournel created the term Kocher-Langenbeck approach which became one of the most important approaches to the hip joint. The further extension of this approach by digastric trochanteric osteotomy and subsequently by surgical hip dislocation enables visualization of the entire hip joint which allows complete evaluation of articular joint damage, quality of reduction and confirmation of extra-articular hardware. With the increasing incidence of acetabular fractures in the elderly there is a concomitant increase of complicating factors, such as multifragmentary posterior wall fractures, dome impaction, marginal impaction and femoral head damage. These factors are negative predictors and compromise a favorable outcome after acetabular surgery. With direct joint visualization these factors can be reliably recognized and corrected as adequately as possible. Surgical hip dislocation thus offers advantages in complex posterior wall, transverse and T-shaped fractures with or without posterior wall involvement. For these fracture types surgical hip dislocation represents a standard approach in our hands.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. METHODS Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). RESULTS In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. CONCLUSIONS Early results for PF-LCP osteosynthesis show major complications in 7 of 19 patients requiring reosteosynthesis or prosthesis implantation due to secondary loss of reduction or hardware removal. Further studies are required to evaluate the limitations of this device.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The issue of phrenic nerve preservation during pneumonectomy is still an unanswered question. So far, its direct effect on immediate postoperative pulmonary lung function has never been evaluated in a prospective trial. METHODS We conducted a prospective crossover study including 10 patients undergoing pneumonectomy for lung cancer between July 2011 and July 2012. After written informed consent, all consecutive patients who agreed to take part in the study and in whom preservation of the phrenic nerve during operation was possible, were included in the study. Upon completion of lung resection, a catheter was placed in the proximal paraphrenic tissue on the pericardial surface. After an initial phase of recovery of 5 days all patients underwent ultrasonographic assessment of diaphragmatic motion followed by lung function testing with and without induced phrenic nerve palsy. The controlled, temporary paralysis of the ipsilateral hemidiaphragm was achieved by local administration of lidocaine 1% at a rate of 3 mL/h (30 mg/h) via the above-mentioned catheter. RESULTS Temporary phrenic nerve palsy was accomplished in all but 1 patient with suspected catheter dislocation. Spirometry showed a significant decrease in dynamic lung volumes (forced expiratory volume in 1 second and forced vital capacity; p < 0.05) with the paralyzed hemidiaphragm. Blood oxygen saturation levels did not change significantly. CONCLUSIONS Our results show that phrenic nerve palsy causes a significant impairment of dynamic lung volumes during the early postoperative period after pneumonectomy. Therefore, in these already compromised patients, intraoperative phrenic nerve injury should be avoided whenever possible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The surgical management of symptomatic femoroacetabular impingement (FAI) generally is indicated after the failure of a trial of nonsurgical treatment. Surgical planning includes an assessment of the labrochondral pathology as well as of the acetabular and proximal femoral bony deformity. Advanced articular cartilage disease generally is associated with poorer outcomes. Surgical hip dislocation and hip arthroscopy have been used, with favorable early outcomes and low complication rates. Careful patient selection is important in predicting the success of the surgical management of symptomatic FAI. A trial of nonsurgical management generally is recommended, but limited information exists regarding its success. The early outcomes of both open and arthroscopic surgical techniques demonstrate significant improvement in most patients, with relatively low rates of complications. Because poorer clinical outcomes are associated with more advanced articular cartilage degeneration, improved strategies for the earlier identification and disease staging of symptomatic patients may enhance the long-term outcomes of both nonsurgical and surgical management.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Numerical simulation experiments give insight into the evolving energy partitioning during high-strain torsion experiments of calcite. Our numerical experiments are designed to derive a generic macroscopic grain size sensitive flow law capable of describing the full evolution from the transient regime to steady state. The transient regime is crucial for understanding the importance of micro structural processes that may lead to strain localization phenomena in deforming materials. This is particularly important in geological and geodynamic applications where the phenomenon of strain localization happens outside the time frame that can be observed under controlled laboratory conditions. Ourmethod is based on an extension of the paleowattmeter approach to the transient regime. We add an empirical hardening law using the Ramberg-Osgood approximation and assess the experiments by an evolution test function of stored over dissipated energy (lambda factor). Parameter studies of, strain hardening, dislocation creep parameter, strain rates, temperature, and lambda factor as well asmesh sensitivity are presented to explore the sensitivity of the newly derived transient/steady state flow law. Our analysis can be seen as one of the first steps in a hybrid computational-laboratory-field modeling workflow. The analysis could be improved through independent verifications by thermographic analysis in physical laboratory experiments to independently assess lambda factor evolution under laboratory conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to determine the frequency of atlanto-axial rotatory subluxations (AARS) in multi detector computed tomography (MDCT) performed on human corpses for forensic purposes and to investigate whether these are a physiological postmortem finding or indicate a trauma to the neck region. 80 forensic cases examined with MDCT from November 2003 to March 2007 were included in the study. The study was approved by the regional ethics committee. For each case volumes were rendered and investigated with reference to suspected AARS and any other anomalies of the head and neck region. The rotation of the head as well as in the atlanto-axial joint were measured and occurring AARS were judged according Fielding's classification. The finding of AARS was correlated to case criteria such as postmortem head rotation, sex, age, cause of death, time since death and further autopsy results. Statistical analysis was performed using Fisher's exact test, Wilcoxon's rank sums test and Chi-square test with Pearson approximation. 70% (n=56) of the cases included in the study presented with an AARS. A strong correlation (P<.0001) between suspected AARS and postmortem head rotation was found. Two cases presented with an atlanto-axial rotation greater than the head rotation. One showed an undiscovered lateral dislocation of the atlas, and one an unfused atlas-ring. There was no correlation to any further investigated case criteria. Ipsilateral AARS with head rotation alone does not indicate trauma to the neck. PmCT can substantially support forensic examinations of the skeleton, especially in body regions, which are elaborate to access at autopsy, such as the cervical spine. Isolated AARS (Fielding type I) on pmCT is usually a normal finding associated with ipsilateral head rotation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the influence of Emmanuel Levinas’s ethics on the rethinking of community in post-identitarian terms (most prominently in the work of Maurice Blanchot, Alphonso Lingis, and, to a lesser extent, Jean-Luc Nancy), the question of community remains a problematic spot in Levinas’s own philosophy. I would argue that, instead of grounding a new thinking of community, the dyadic relation of Same and Other poses a structural problem when trying to open the ethical relation to the wider realm of others while keeping radical difference in place. As external observer and guarantor of justice, for instance, is the Third excluded a priori from the ethical relation? Is community always only another term for the political? Or, as Levinas himself puts it in Otherwise Than Being: “What meaning can community take on in difference without reducing difference?” Identifying in the notion of impersonality a way to access Levinas’s thought on community, this paper aims at rethinking the scene of address and the ethical relation in terms of displacement, dislocation and interruption.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Low viscosity domains such as localized shear zones exert an important control on the geodynamics of the uppermost mantle. Grain size reduction and subsequent strain localization related to a switch from dislocation to diffusion creep is one mechanism to form low viscosity domains. To sustain strain localization, the grain size of mantle minerals needs to be kept small over geological timescales. One way to keep olivine grain sizes small is by pinning of mobile grain boundaries during grain growth by other minerals (second phases). Detailed microstructural studies based on natural samples from three shear zones formed at different geodynamic settings, allowed the derivation of the olivine grain-size dependence on the second-phase content. The polymineralic olivine grain-size evolution with increasing strain is similar in the three shear zones. If the second phases are to pin the mobile olivine grain boundary the phases need to be well mixed before grain growth. We suggest that melt-rock and metamorphic reactions are crucial for the initial phase mixing in mantle rocks. With ongoing deformation and increasing strain, grain boundary sliding combined with mass transfer processes and nucleation of grains promotes phase mixing resulting in fine-grained polymineralic mixtures that deform by diffusion creep. Strain localization due to the presence of volumetrically minor minerals in polymineralic mantle rocks is only important at high strain deformation (ultramylonites) at low temperatures (<~800°C). At smaller strain and stress conditions and/or higher temperatures other parameters like overall energy available to deform a given rock volume, the inheritance of mechanical anisotropies or the presence of water or melts needs to be considered to explain strain localization in the upper mantle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Malposition of the acetabular component in total hip arthroplasty (THA) is a common surgical problem that can lead to hip dislocation, reduced range of motion and may result in early loosening. The aim of this study is to validate the accuracy and reproducibility of a single x-ray image based 2D/3D reconstruction technique in determining cup inclination and anteversion against two different computer tomography (CT)-based measurement techniques. Methods Cup anteversion and inclination of 20 patients after cementless primary THA was measured on standard anteroposterior (AP) radiographs with the help of the single x-ray 2D/3D reconstruction program and compared with two different 3D CT-based analyses [Ground Truth (GT) and MeVis (MV) reconstruction model]. Results The measurements from the single x-ray 2D/3D reconstruction technique were strongly correlated with both types of CT image-processing protocols for both cup inclination [R²=0.69 (GT); R²=0.59 (MV)] and anteversion [R²=0.89 (GT); R²=0.80 (MV)]. Conclusions The single x-ray image based 2D/3D reconstruction technique is a feasible method to assess cup position on postoperative x-rays. CTscans remain the golden standard for a more complex biomechanical evaluation when a lower tolerance limit (+/-2 degrees) is required.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Both acetabular undercoverage (hip dysplasia) and overcoverage (pincer-type femoroacetabular impingement) can result in hip osteoarthritis. In contrast to undercoverage, there is a lack of information on radiographic reference values for excessive acetabular coverage. Questions/purposes (1) How do common radiographic hip parameters differ in hips with a deficient or an excessive acetabulum in relation to a control group; and (2) what are the reference values determined from these data for acetabular under- and overcoverage? Methods We retrospectively compared 11 radiographic parameters describing the radiographic acetabular anatomy among hip dysplasia (26 hips undergoing periacetabular osteotomy), control hips (21 hips, requiring no rim trimming during surgical hip dislocation), hips with overcoverage (14 hips, requiring rim trimming during surgical hip dislocation), and hips with severe overcoverage (25 hips, defined as having acetabular protrusio). The hips were selected from a patient cohort of a total of 593 hips. Radiographic parameters were assessed with computerized methods on anteroposterior pelvic radiographs and corrected for neutral pelvic orientation with the help of a true lateral radiograph. Results All parameters except the crossover sign differed among the four study groups. From dysplasia through control and overcoverage, the lateral center-edge angle, acetabular arc, and anteroposterior/craniocaudal coverage increased. In contrast, the medial center-edge angle, extrusion/acetabular index, Sharp angle, and prevalence of the posterior wall sign decreased. The following reference values were found: lateral center-edge angle 23° to 33°, medial center-edge angle 35° to 44°, acetabular arc 61° to 65°, extrusion index 17% to 27%, acetabular index 3° to 13°, Sharp angle 38° to 42°, negative crossover sign, positive posterior wall sign, anterior femoral head coverage 15% to 26%, posterior femoral head coverage 36% to 47%, and craniocaudal coverage 70% to 83%. Conclusions These acetabular reference values define excessive and deficient coverage. They may be used for radiographic evaluation of symptomatic hips, may offer possible predictors for surgical outcomes, and serve to guide clinical decision-making.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The biomechanical properties of the atlanto-axial joint in a young Yorkshire Terrier dog with spontaneous atlantoaxial instability were compared to those of another young toy breed dog with a healthy atlantoaxial joint. The range-of-motion was increased in flexion and lateral bending in the unstable joint. In addition, lateral bending led to torsion and dorsal dislocation of the axis within the atlas. On gross examination, the dens ligaments were absent and a longitudinal tear of the tectorial membrane was observed. These findings suggest that both ventral and lateral flexion may lead to severe spinal cord compression, and that the tectorial membrane may play a protective role in some cases of atlantoaxial instability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Treatment of displaced tarsal navicular body fractures usually consists of open reduction and internal fixation. However, there is little literature reporting results of this treatment and correlation to fracture severity. METHODS We report the results of 24 patients treated in our institution over a 12-year period. Primary outcome measurements were Visual-Analogue-Scale Foot and Ankle score (VAS-FA), AOFAS midfoot score, and talonavicular osteoarthritis at final follow-up. According to a new classification system reflecting talonavicular joint damage, 2-part fractures were classified as type I, multifragmentary fractures as type II, and fractures with talonavicular joint dislocation and/or concomitant talar head fractures as type III. Spearman's coefficients tested this classification's correlation with the primary outcome measurements. Mean patient age was 33 (range 16-61) years and mean follow-up duration 73 (range 24-159) months. RESULTS Average VAS-FA score was 74.7 (standard deviation [SD] 16.9), and average AOFAS midfoot score was 83.8 (SD = 12.8). Final radiographs showed no talonavicular arthritis in 5 patients, grade 1 in 7, grade 2 in 3, grade 3 in 6, and grade 4 in 1 patient. Two patients had secondary or spontaneous talonavicular fusion. Spearman coefficients showed strong correlation of the classification system with VAS-FA score (r = -0.663, P < .005) and talonavicular arthritis (r = 0.600, P = .003), and moderate correlation with AOFAS score (r = -.509, P = .011). CONCLUSION At midterm follow-up, open reduction and internal fixation of navicular body fractures led to good clinical outcome but was closely related to fracture severity. A new classification based on the degree of talonavicular joint damage showed close correlation to clinical and radiologic outcome. LEVEL OF EVIDENCE Level IV, retrospective case series.