PURPOSE: To compare two techniques used to create a larger animal model of venous valve incompetence. MATERIALS AND METHODS: To achieve vein dilatation as the primary cause of valve incompetence, common carotid jugular vein (JV) fistulas were created and optional filters were placed into the JV of sheep. Altogether, nine inferior vena cava filters were placed in three sheep in two stages. Six filters were placed caudal to the most caudal JV valve in three sheep and removed 6 weeks later. Then, three filters were placed across the most caudal valve in two sheep with competent valves and removed 3 weeks later. A common carotid artery-JV fistula was created in three sheep and followed-up for 1-3 weeks. Ascending and descending venograms were obtained to determine the JV sizes and function of their valves. The JVs removed at necropsy were studied with venoscopy. RESULTS: Only one of the six JVs with filters caudal to the most caudal valve had incompetent valves after filter removal at 6 weeks. In addition, only one of three JVs with the filter across the valve had incompetent valves after filter removal at 3 weeks. At 1-3-week follow-up of the group with common carotid artery-JV fistula, all three JVs had incompetent valves in the cephalad vein portion, but only one JV had an incompetent valve in its caudal portion. At venoscopy, the incompetent valves showed various degrees of damage ranging from shortening to the destruction of valve leaflets. CONCLUSION: Dilation of the valve annulus with a removable vena cava filter failed to produce valve incompetence. The promising results with the common carotid artery-JV fistula justify further detailed research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Limited experience with bioprosthetic venous valve percutaneously inserted into femoral veins in 15 patients has been promising in short-term results only to show disappointing long-term results. Percutaneous autogenous venous valve (PAVV) transplantation was explored in an ovine model as a possible alternative treatment. METHODS: PAVV consisted of a vein segment containing a valve that was attached to a stent template. The stent templates (n = 9) were designed and hand made in our research laboratory. They consist of two stainless steel square stents 13 or 15 mm in diameter to fit the ovine jugular veins (JV), which ranges from 10 to 15 mm in diameter. A valve-containing segment of JV was harvested and attached with sutures and barbs inside the stent template (n = 9). The valve devices were then manually folded and front loaded inside the 4 cm chamber of the 13F delivery sheath and delivered into the contralateral JV by femoral vein approach. Transplanted PAVVs were studied by immediate and 3 months venograms. Animals were euthanized at 3 months, and jugular veins harvested to perform angioscopic evaluations in vitro. RESULTS: PAVV transplantation was successful in all nine animals. Good valve function with no reflux was observed on immediate and 3 months venograms in eight valves. The transplanted maximal JV diameter ranged from 10.2 mm to 15.4 mm (mean 13.1 +/- 1.5 mm). Venoscopic examination revealed intact, flexible, nonthickened valve leaflets in eight specimens. One PAVV exhibited normal function of one leaflet only; the other cusp was accidentally cut during the transplantation procedure. All transplanted autologous valves were free of thrombus and incorporated into the vein wall of the host vessel. CONCLUSION: This study demonstrated that autogenous valve transplants remained patent and competent without long-term anticoagulation for up to 3 months. The percutaneous autogenous venous valve may provide in future minimally invasive treatment for patients with chronic deep venous insufficiency, but long-term studies need to be done to document its continued patency and function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous valve replacement for severe aortic stenosis has shown to be an alternative treatment option for non-surgical candidates. We report on the first successful valve in valve procedure in an 80-year-old patient with a severe regurgitation of a degenerated aortic bioprosthesis using the Corevalve Revalving system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND AIM OF THE STUDY: Preservation of the aortic valve during the repair of acute type A aortic dissection (AADA) is a viable option to prevent lifelong oral anticoagulation. The study aim was to assess aortic valve function following resuspension and supracoronary ascending aortic grafting. METHODS: Among a collective of 210 consecutive patients undergoing surgery for AADA, 140 (66.7%) with resuspension of the aortic valve and supracoronary ascending graft were analyzed. Of these patients, 83 (59.3%) had a complete follow up (mean 61.2 +/- 40.8 months), with 65 of the subgroup (78.3%) being followed by computed tomography scanning and echocardiography. RESULTS: Reoperation due to severe aortic valve regurgitation was required in seven patients (10.8%). The perioperative characteristics were similar in these patients; notably, no significant difference was evident with regards to the aortic annulus diameter and the severity of regurgitation at the time of surgery. The left ventricular mass index was significantly higher in patients requiring reoperation due to aortic valve regurgitation (219.3 +/- 146.6 versus 123.9 +/- 146.6 g/m2; p <0.05). None of the patients died as a result of reoperation. CONCLUSION: The long-term functional results following resuspension of the aortic valve in AADA were very good. A close echocardiographic follow up was necessary, as reoperation of the aortic valve was required in more than 10% of the collective, with an average follow up of five years. Reoperation was mainly related to secondary dilatation of the aortic root.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: The standard surgical repair of disease of the aortic valve and the ascending aorta has been combined replacement, which includes the disadvantage of inserting a mechanical valve. We have investigated an individualized approach which preserves the native valve. PATIENTS AND METHODS: Between October 1995 and October 1997, a consecutive total of 101 patients (72 men, 29 women, aged 21-83 years) underwent operations for disease of the ascending aorta: aortic dissection type A in 34 patients, aneurysmal dilatation in 67. Dilatation of the aortic arch was associated with aortic regurgitation in 58 patients. There were 11 patients with aortic valve stenosis or previously implanted aortic valve prosthesis among a total of 46 whose aortic valve was replaced (group II). Supracommissural aortic replacement with a Dacron tube was performed in 16 patients (group I) with normal valve cusps and an aortic root diameter < 3.5 cm. In 28 patients with an aortic root diameter of 3.5-5.0 cm the aortic root was remodelled (group III). Resuspension of the native aortic valve was undertaken in 11 patients with aortic root dilatation of > 5.0 cm (group IV). RESULTS: Operative intervention was electively performed in 72 patients, without any death. Of 29 patients operated as an emergency for acute type A dissection four died (14%). In 55 of the 58 patients with aortic regurgitation in proved possible to preserve native aortic valve (95%). In the early postoperative phase and after an average follow-up time of 11.8 months, transthoracic echocardiography demonstrated good aortic valve function, except in one patient each of groups III and IV who developed aortic regurgitation grades I or II. CONCLUSION: The described individualized approach makes it possible to preserve the native aortic valve in most patients with aortic regurgitation, at a low risk. Follow-up observations so far indicate good results of the reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tricuspid regurgitation following heart transplantation can become a severe problem in a subset of patients, where medical therapy fails. Operative findings are described and results of subsequent results with surgical intervention including repair and replacement are analysed. Although follow-up is short, tricuspid replacement seems superior to reconstruction following heart transplantation. Best results are obtained, if replacement is performed, before right ventricular function deteriorates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present report the prevalence, severity, and risk factors of tricuspid valve regurgitation (TR) in 251 heart transplant recipients have been analyzed retrospectively. Tricuspid valve function was studied by color-flow Doppler echocardiogram and annual heart catheterization. The presence or severity of TR was graded on a scale from 0 (no TR) to 4 (severe). Additional postoperative data included rate of rejection, number of endomyocardial biopsies, incidence of transplant vasculopathy, and preoperative and postoperative hemodynamics. The incidence of grade 3 TR increases from 5% at 1 year to 50% at 4 years after transplantation. Multivariate analysis showed rate of rejection and donor heart weight to be significant risk factors. The ischemic intervals as well as the preoperative and postoperative pulmonary hemodynamics did not affect the severity or prevalence of TR. These results indicate that various factors appear to have an impact on the development of TR and that the prevalence might be lowered by a reduction of the number of biopsies performed and when possible, oversizing of donor hearts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Regression of left ventricular (LV) hypertrophy with normalization of diastolic function has been reported in patients with aortic stenosis late after aortic valve replacement (AVR). The purpose of the present study was to evaluate the effect of AVR on LV function and structure in chronic aortic regurgitation early and late after AVR. METHODS AND RESULTS: Twenty-six patients were included in the present analysis. Eleven patients with severe aortic regurgitation were studied before, early (21 months) and late (89 months) after AVR through the use of LV biplane angiograms, high-fidelity pressure measurements, and LV endomyocardial biopsies. Fifteen healthy subjects were used as controls. LV systolic function was determined from biplane ejection fraction and midwall fractional shortening. LV diastolic function was calculated from the time constant of LV relaxation, peak filling rates, and myocardial stiffness constant. LV structure was assessed from muscle fiber diameter, interstitial fibrosis, and fibrous content. LV muscle mass decreased significantly by 38% early and 55% late after surgery. Ejection fraction was significantly reduced preoperatively and did not change after AVR (P=NS). LV relaxation was significantly prolonged before surgery (89+/-28 ms) but was normalized late after AVR (42+/-14 ms). Early and late peak filling rates were increased preoperatively but normalized postoperatively. Diastolic stiffness constant was increased before surgery (22+/-6 versus 9+/-3 in control subjects; P=0.0003) and remained elevated early and late after AVR (23+/-4; P=0.002). Muscle fiber diameter decreased significantly after AVR but remained increased at late follow-up. Interstitial fibrosis was increased preoperatively and increased even further early but decreased late after AVR. Fibrosis was positively linearly correlated to myocardial stiffness and inversely correlated to LV ejection fraction. CONCLUSIONS: Patients with aortic regurgitation show normalization of macroscopic LV hypertrophy late after AVR, although fiber hypertrophy persists. These changes in LV myocardial structure late after AVR are accompanied by a change in passive elastic properties with persistent diastolic dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the relative contribution of hemodynamic and clinical factors to serum natriuretic peptide elevation in seventy-one patients with either aortic stenosis or aortic regurgitation. We found that pulmonary hypertension, heart failure and renal failure are the most powerful independent predictors of natriuretic peptide elevation in patients with aortic valve disease, irrespective of the type or severity of valvular lesion itself.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The association between aortic valve disease and coronary atherosclerosis is common. In the recent era of percutaneous aortic valve replacement (PAVR), there is little experience with coronary artery intervention after valve implantation. CASE REPORT: To our knowledge, this is the first case of successful percutaneous coronary intervention after implantation of a CoreValve percutaneous aortic valve. We report a case of a 79-year-old female patient who underwent successful coronary artery intervention few months after a CoreValve's percutaneous implantation for severe aortic valve stenosis. Verifying the position of the used wires (crossing from inside the self expanding frame) is of utmost importance before proceeding to coronary intervention. In this case, crossing the aortic valve, coronary angiography, and multivessel stenting were successfully performed. CONCLUSION: Percutaneous coronary intervention in patients with previous CoreValve is feasible and safe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Transcatheter aortic valve implantation (TAVI) for high-risk and inoperable patients with severe aortic stenosis is an emerging procedure in cardiovascular medicine. Little is known of the impact of TAVI on renal function. METHODS: We analysed retrospectively renal baseline characteristics and outcome in 58 patients including 2 patients on chronic haemodialysis undergoing TAVI at our institution. Acute kidney injury (AKI) was defined according to the RIFLE classification. RESULTS: Fifty-eight patients with severe symptomatic aortic stenosis not considered suitable for conventional surgical valve replacement with a mean age of 83 +/- 5 years underwent TAVI. Two patients died during transfemoral valve implantation and two patients in the first month after TAVI resulting in a 30-day mortality of 6.9%. Vascular access was transfemoral in 46 patients and transapical in 12. Estimated glomerular filtration rate (eGFR) increased in 30 patients (56%). Fifteen patients (28%) developed AKI, of which four patients had to be dialyzed temporarily and one remained on chronic renal replacement therapy. Risk factors for AKI comprised, among others, transapical access, number of blood transfusions, postinterventional thrombocytopaenia and severe inflammatory response syndrome (SIRS). CONCLUSIONS: TAVI is feasible in patients with a high burden of comorbidities and in patients with pre-existing end-stage renal disease who would be otherwise not considered as candidates for conventional aortic valve replacement. Although GFR improved in more than half of the patients, this benefit was associated with a risk of postinterventional AKI. Future investigations should define preventive measures of peri-procedural kidney injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: It is unclear whether transcatheter aortic valve implantation (TAVI) addresses an unmet clinical need for those currently rejected for surgical aortic valve replacement (SAVR) and whether there is a subgroup of high-risk patients benefiting more from TAVI compared to SAVR. In this two-centre, prospective cohort study, we compared baseline characteristics and 30-day mortality between TAVI and SAVR in consecutive patients undergoing invasive treatment for aortic stenosis. METHODS AND RESULTS: We pre-specified different adjustment methods to examine the effect of TAVI as compared with SAVR on overall 30-day mortality: crude univariable logistic regression analysis, multivariable analysis adjusted for baseline characteristics, analysis adjusted for propensity scores, propensity score matched analysis, and weighted analysis using the inverse probability of treatment (IPT) as weights. A total of 1,122 patients were included in the study: 114 undergoing TAVI and 1,008 patients undergoing SAVR. The crude mortality rate was greater in the TAVI group (9.6% vs. 2.3%) yielding an odds ratio [OR] of 4.57 (95%-CI 2.17-9.65). Compared to patients undergoing SAVR, patients with TAVI were older, more likely to be in NYHA class III and IV, and had a considerably higher logistic EuroSCORE and more comorbid conditions. Adjusted OR depended on the method used to control for confounding and ranged from 0.60 (0.11-3.36) to 7.57 (0.91-63.0). We examined the distribution of propensity scores and found scores to overlap sufficiently only in a narrow range. In patients with sufficient overlap of propensity scores, adjusted OR ranged from 0.35 (0.04-2.72) to 3.17 (0.31 to 31.9). In patients with insufficient overlap, we consistently found increased odds of death associated with TAVI compared with SAVR irrespective of the method used to control confounding, with adjusted OR ranging from 5.88 (0.67-51.8) to 25.7 (0.88-750). Approximately one third of patients undergoing TAVI were found to be potentially eligible for a randomised comparison of TAVI versus SAVR. CONCLUSIONS: Both measured and unmeasured confounding limit the conclusions that can be drawn from observational comparisons of TAVI versus SAVR. Our study indicates that TAVI could be associated with either substantial benefits or harms. Randomised comparisons of TAVI versus SAVR are warranted.