212 resultados para Three-dimensional computed tomography
Resumo:
The purpose of the present study was to compare conventional intraoral periapical radiographs (PA) with limited cone beam computed tomography (CBCT) for evaluation of mandibular molars prior to apical surgery. The apical extent and homogeneity of the root canal fillings (RCF) as well as the number of root canals were examined.
Resumo:
This retrospective radiographic study analyzed the dimensions of the alveolar bone in the posterior dentate mandible based on cone beam computed tomography (CBCT) images. A total of 56 CBCT images met the inclusion criteria, resulting in a sample size of 122 cross sections showing posterior mandibular teeth (premolars and molars). The thickness of the buccal and lingual bone walls was measured at two locations: 4 mm apical to the cementoenamel junction (measurement point 1, MP1) and at the middle of the root (measurement point 2, MP2). Further, alveolar bone width was assessed at the level of the most coronal buccal bone detectable (alveolar bone width 1, BW1) and at the superior border of the mandibular canal (alveolar bone width 2, BW2). The vertical distance between the two as well as the presence of a lingual undercut were also analyzed. There was a steady increase in buccal bone wall thickness from the first premolar to the second molar at both MP1 and MP2. BW1 at the level of the premolars was significantly thinner than that for molars. Alveolar bone height was constant for all teeth examined. For the selection of an appropriate postextraction treatment approach, analysis of the alveolar bone dimensions at the tooth to be extracted by means of CBCT can offer valuable information concerning bone volume and morphology at the future implant site.
Resumo:
The purpose of the present study was to evaluate the thickness and the anatomic characteristics of the Schneiderian membrane and cortical bone using limited cone beam computed tomography (CBCT) scannning in patients referred for planning of apical surgery of maxillary molars.
Resumo:
Minor brain injury is a frequent condition. Validated clinical decision rules can help in deciding whether a computed tomogram (CT) of the head is required. We hypothesized that institutional guidelines are not frequently used, and that psychological factors are a common reason for ordering an unnecessary CT.
Resumo:
Advances in diagnostic imaging and the introduction of damage control strategy in trauma have influenced our approach to treating liver trauma patients. The objective of the present study was to investigate the impact of change in liver trauma management on outcome.
Resumo:
A new generation of high definition computed tomography (HDCT) 64-slice devices complemented by a new iterative image reconstruction algorithm-adaptive statistical iterative reconstruction, offer substantially higher resolution compared to standard definition CT (SDCT) scanners. As high resolution confers higher noise we have compared image quality and radiation dose of coronary computed tomography angiography (CCTA) from HDCT versus SDCT. Consecutive patients (n = 93) underwent HDCT, and were compared to 93 patients who had previously undergone CCTA with SDCT matched for heart rate (HR), HR variability and body mass index (BMI). Tube voltage and current were adapted to the patient's BMI, using identical protocols in both groups. The image quality of all CCTA scans was evaluated by two independent readers in all coronary segments using a 4-point scale (1, excellent image quality; 2, blurring of the vessel wall; 3, image with artefacts but evaluative; 4, non-evaluative). Effective radiation dose was calculated from DLP multiplied by a conversion factor (0.014 mSv/mGy × cm). The mean image quality score from HDCT versus SDCT was comparable (2.02 ± 0.68 vs. 2.00 ± 0.76). Mean effective radiation dose did not significantly differ between HDCT (1.7 ± 0.6 mSv, range 1.0-3.7 mSv) and SDCT (1.9 ± 0.8 mSv, range 0.8-5.5 mSv; P = n.s.). HDCT scanners allow low-dose 64-slice CCTA scanning with higher resolution than SDCT but maintained image quality and equally low radiation dose. Whether this will translate into higher accuracy of HDCT for CAD detection remains to be evaluated.
Resumo:
Whole-body computed tomography (WBCT) plays an important role in the management of severely injured patients. We evaluated the radiation exposure of WBCT scans using different positioning boards and arm positions.
Resumo:
To assess the ability of low-dose CT to detect and characterize the most common CT patterns of pulmonary disease.
Resumo:
In this study, we show the use of three-dimensional printing models for preoperative planning of transcatheter valve replacement in a patient with an extreme porcelain aorta. A 70-year-old man with severe aortic stenosis and a porcelain aorta was referred to our center for transcatheter aortic valve replacement. Unfortunately, the patient died after the procedure because of a potential ischemic event. Therefore, we decided to fabricate three-dimensional models to evaluate the potential effects of these constructs for previous surgical planning and simulation of the transcatheter valve replacement.
Resumo:
Within the next few years, the medical industry will launch increasingly affordable three-dimensional (3D) vision systems for the operating room (OR). This study aimed to evaluate the effect of two-dimensional (2D) and 3D visualization on surgical skills and task performance.
Resumo:
The post-mortem use of modern imaging techniques such as multislice computed tomography (MSCT) is becoming increasingly important as an aid for conventional autopsy. This article presents a case of a 4-month-old boy who died from sudden infant death syndrome (SIDS) with intravascular gas after an intraosseus medication application documented by post-mortem MSCT. It is most likely that the gas entered the body during resuscitation. This case emphasises the advantage of post-mortem imaging as a complementary aid for the autopsy. We conclude that during emergency treatment, the medical staff should be aware of the possibility of causing a gas embolism following intraosseus medication. Resuscitation with an inserted, disconnected intraosseous needle should be avoided.
Resumo:
OBJECTIVE: Computed tomography (CT) and magnetic resonance imaging (MRI) are introduced as an alternative to traditional autopsy. The purpose of this study was to investigate their accuracy in mass estimation of liver and spleen. METHODS: In 44 cases, the weights of spleen and liver were estimated based on MRI and CT data using a volume-analysis software and a postmortem tissue-specific density factor. In a blinded approach, the results were compared with the weights noted at autopsy. RESULTS: Excellent correlation between estimated and real weights (r = 0.997 for MRI, r = 0.997 for CT) was found. Putrefaction gas and venous air embolism led to an overestimation. Venous congestion and drowning caused higher estimated weights. CONCLUSION: Postmortem weights of liver and spleen can accurately be assessed by nondestructive imaging. Multislice CT overcomes the limitation of putrefaction and venous air embolism by the possibility to exclude gas. Congestion seems to be even better assessed.
Resumo:
In forensic autopsies, one of the most important and common signs of violence to the neck is hemorrhages of the soft tissues. The Institute of Forensic Medicine in Bern evaluates the usefulness of postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) of forensic cases prior to autopsy. The aim of this study was to prove the sensitivity of postmortem MSCT and MRI in the detection of hemorrhages of the neck muscles. A full body scan prior to and a detailed scan of the explanted larynx after autopsy were performed. MSCT detected multiple fractures of the larynx. Detailed MRI was able to demonstrate the hemorrhage of the left posterior cricoarytenoid muscle. The minor hemorrhage of the right posterior cricoarytenoid muscle could not be detected with certainty. Although more experience is required, we conclude that combined MRI and MSCT examination is a useful tool for documentation and examination of neck muscle hemorrhages in forensic cases.