242 resultados para Theta burst stimulation (TBS)
Resumo:
We sought to characterize the excitability properties of tibialis anterior (TA) and brachioradialis (BR) muscles at rest and during electrically induced muscle activation in normal subjects.
Resumo:
Auditory hallucinations comprise a critical domain of psychopathology in schizophrenia. Repetitive transcranial magnetic stimulation (TMS) has shown promise as an intervention with both positive and negative reports. The aim of this study was to test resting-brain perfusion before treatment as a possible biological marker of response to repetitive TMS. Twenty-four medicated patients underwent resting-brain perfusion magnetic resonance imaging with arterial spin labeling (ASL) before 10 days of repetitive TMS treatment. Response was defined as a reduction in the hallucination change scale of at least 50%. Responders (n=9) were robustly differentiated from nonresponders (n=15) to repetitive TMS by the higher regional cerebral blood flow (CBF) in the left superior temporal gyrus (STG) (P<0.05, corrected) before treatment. Resting-brain perfusion in the left STG predicted the response to repetitive TMS in this study sample, suggesting this parameter as a possible bio-marker of response in patients with schizophrenia and auditory hallucinations. Being noninvasive and relatively easy to use, resting perfusion measurement before treatment might be a clinically relevant way to identify possible responders and nonresponders to repetitive TMS.
Resumo:
Transcranial magnetic stimulation (TMS) is a novel therapeutic approach, used in patients with pharmacoresistant auditory verbal hallucinations (AVH). To investigate the neurobiological effects of TMS on AVH, we measured cerebral blood flow with pseudo-continuous magnetic resonance-arterial spin labeling 20 ± 6 hours before and after TMS treatment.
Resumo:
The pain and distress associated with transcutaneous electrical nerve stimulation (TENS) of the udder was evaluated by treating 20 healthy dairy cows with an electrical udder stimulator. This generated a sequence of pulses (frequency: 160+/-10% impulses per second, duration 250 mus) and provided voltage ranges from 0 to 10 volts (+/-10%). Trials took place on three consecutive days, twice daily after morning and evening milking. Daily sessions were divided into two periods: (1) control (sham treatment) and (2) treatment (real treatment). Physiological (heart rate, respiratory rate, and plasma cortisol concentration) as well as ethological parameters (kicking, weight shifting, and looking backwards to udder) were defined as pain-indicating parameters and observed. Evaluation of data showed that only one parameter (kicking) was significantly increased during real treatment compared to sham treatment. It is concluded that the TENS therapy tested in this study can evoke changes in behaviour (increased kicking) consistent with an experience of pain in some cows.
Resumo:
Experiments were designed to investigate the suitability of a combination of a short manual teat stimulation with a short latency period before teat cup attachment to induce and maintain oxytocin release and milk ejection without interruption. In Experiment 1, seven dairy cows in mid lactation were manually pre-stimulated for 15, 30 or 45 s, followed by either 30 s or 45 s of latency period. It was shown that all treatments induced a similar release of oxytocin without interruption until the end of milking. In particular, the latency period of up to 45 s did not cause a transient decrease of oxytocin concentration. In Experiment 2, milking characteristics were recorded in seven cows each in early, mid, and late lactation, respectively. Because the course of milk ejection depends mainly on the degree of udder filling, individual milkings were classified based on the actual degree of udder filling which differs between lactational stages but also between morning and evening milkings. All animals underwent twelve different udder preparation treatments, i.e. 15, 30, or 45 s of pre-stimulation followed by latency periods of 0, 30, 45, or 60 s. Milking characteristics were recorded. Total milk yield, main milking time and average milk flow rate did not differ between treatments if the degree of udder filling at the start of milking was >40% of the maximum storage capacity. However, if the udder filling was <40%, main milking time was decreased with the duration of a latency period up to 45 s, independent of duration of pre-stimulation. Average milk flow at an udder filling of <40% was highest after a pre-stimulation of 45 s followed by a latency period of another 45 s. In contrast, average milk flow reached its lowest values at a pre-stimulation of 15 s without additional latency period. However, average milk flow after a 15-s pre-stimulation increased with increasing latency period. In conclusion, a very short pre-stimulation when followed by a latency period up to 45 s before teat cup attachment remains a suitable alternative for continuous stimulation to induce milk ejection.
Resumo:
The aim of this study was to quantify the effects of isoflurane at approximately the minimum alveolar concentration (peri-MAC) on the temporal summation (TS) of reflex activity in ponies. TS was evoked by repeated electrical stimulations applied at 5 Hz for 2 s on the digital nerve of the left forelimb of seven ponies. Surface electromyographic activity was recorded from the deltoid and common digital extensor muscles. TS thresholds and amplitude of response to stimulations of increasing intensities were assessed during anaesthesia at 0.85, 0.95 and 1.05 times the individual MAC, and after anaesthesia in standing animals. Under isoflurane anaesthesia, TS thresholds increased significantly in a concentration-dependent fashion and at each isoflurane MAC, the responses increased significantly for increasing stimulation intensities. A concentration-dependent depression of evoked reflexes with a reduction in the slopes of the stimulus-response function was observed for both muscles. The results demonstrated that with this model it is possible to describe and quantify the effects of anaesthetics on spinal sensory-motor processing in ponies.
Resumo:
We report on a patient who developed, from 5 months of age, multiple seizure types, including myoclonic, associated with severe psychomotor delay, leading to the diagnosis of Dravet syndrome. Over the years, he developed refractory epilepsy and was implanted with a vagus nerve stimulator at the age of 19. After 3 months, he experienced a progressive improvement of partial and generalized seizures, with a >90% reduction, and better alertness. This meaningful clinical improvement is discussed in the light of the sudden unexpected death in epilepsy risk, which is high in this setting, and seems remarkably diminished in our patient in view of the reduction of generalized convulsions.
Resumo:
This paper provides a theoretical assessment of the safety considerations encountered in the simultaneous use of transcranial magnetic stimulation (TMS) and neurological interventions involving implanted metallic electrodes, such as electrocorticography. Metal implants are subject to magnetic forces due to fast alternating magnetic fields produced by the TMS coil. The question of whether the mechanical movement of the implants leads to irreversible damage of brain tissue is addressed by an electromagnetic simulation which quantifies the magnitude of imposed magnetic forces. The assessment is followed by a careful mechanical analysis determining the maximum tolerable force which does not cause irreversible tissue damage. Results of this investigation provide useful information on the range of TMS stimulator output powers which can be safely used in patients having metallic implants. It is shown that conventional TMS applications can be considered safe when applied on patients with typical electrode implants as the induced stress in the brain tissue remains well below the limit of tissue damage.
Resumo:
Deep brain stimulation (DBS) of different nuclei is being evaluated as a treatment for epilepsy. While encouraging results have been reported, the effects of changes in stimulation parameters have been poorly studied. Here the effects of changes of pulse waveform in high frequency DBS (130 Hz) of the amygdala-hippocampal complex (AH) are presented. These effects were studied on interictal epileptic discharge rates (IEDRs). AH-DBS was implemented with biphasic versus pseudo monophasic charge balanced pulses, in two groups of patients: six with temporal lobe epilepsy (TLE) associated with hippocampal sclerosis (HS) and six with non lesional (NLES) temporal epilepsy. In patients with HS, IEDRs were significantly reduced with AH-DBS applied with biphasic pulses in comparison with monophasic pulse. IEDRs were significantly reduced in only two patients with NLES independently to stimulus waveform. Comparison to long-term seizure outcome suggests that IEDRs could be used as a neurophysiological marker of chronic AH-DBS and they suggest that the waveform of the electrical stimuli can play a major role in DBS. We concluded that biphasic stimuli are more efficient than pseudo monophasic pulses in AH-DBS in patients with HS. In patients with NLES epilepsy, other parameters relevant for efficacy of DBS remain to be determined.
Resumo:
Inferolateral early repolarization (ER) and Brugada syndrome manifest with J waves. Isoproterenol suppresses recurrent ventricular arrhythmias while reducing J waves in both disorders.