83 resultados para Shoulder harnesses.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE The objective of this study was to evaluate stiffness, strength, and failure modes of monolithic crowns produced using computer-aided design/computer-assisted manufacture, which are connected to diverse titanium and zirconia abutments on an implant system with tapered, internal connections. MATERIALS AND METHODS Twenty monolithic lithium disilicate (LS2) crowns were constructed and loaded on bone level-type implants in a universal testing machine under quasistatic conditions according to DIN ISO 14801. Comparative analysis included a 2 × 2 format: prefabricated titanium abutments using proprietary bonding bases (group A) vs nonproprietary bonding bases (group B), and customized zirconia abutments using proprietary Straumann CARES (group C) vs nonproprietary Astra Atlantis (group D) material. Stiffness and strength were assessed and calculated statistically with the Wilcoxon rank sum test. Cross-sections of each tested group were inspected microscopically. RESULTS Loaded LS2 crowns, implants, and abutment screws in all tested specimens (groups A, B, C, and D) did not show any visible fractures. For an analysis of titanium abutments (groups A and B), stiffness and strength showed equally high stability. In contrast, proprietary and nonproprietary customized zirconia abutments exhibited statistically significant differences with a mean strength of 366 N (Astra) and 541 N (CARES) (P < .05); as well as a mean stiffness of 884 N/mm (Astra) and 1,751 N/mm (CARES) (P < .05), respectively. Microscopic cross-sections revealed cracks in all zirconia abutments (groups C and D) below the implant shoulder. CONCLUSION Depending on the abutment design, prefabricated titanium abutment and proprietary customized zirconia implant-abutment connections in conjunction with monolithic LS2 crowns had the best results in this laboratory investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The rotator cuff is a complex musculotendinous unit, which plays a major role in glenohumeral joint stability and mobilization. Tears of the rotator cuff tendon and its subsequent changes of the rotator cuff muscle are common, and the incidence increases with age. Several structures such as the muscle, tendon, and bone may contribute to the development of a tear as well as on the outcome following a rotator cuff repair. Knowledge of these structures may help to improve rotator cuff healing after rotator cuff tear. The goal of this chapter is to discuss the evidence which exists with regard to the pathophysiological changes in the muscle, tendon, and bone that lead to a rotator cuff rupture as well as the changes that occur in these structures after a tear has occurred.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE The aim of this cross-sectional study was to estimate bone loss of implants with platform-switching design and analyze possible risk indicators after 5 years of loading in a multi-centered private practice network. METHOD AND MATERIALS Peri-implant bone loss was measured radiographically as the distance from the implant shoulder to the mesial and distal alveolar crest, respectively. Risk factor analysis for marginal bone loss included type of implant prosthetic treatment concept and dental status of the opposite arch. RESULTS A total of 316 implants in 98 study patients after 5 years of loading were examined. The overall mean value for radiographic bone loss was 1.02 mm (SD ± 1.25 mm, 95% CI 0.90- 1.14). Correlation analyses indicated a strong association of peri-implant bone loss > 2 mm for removable implant-retained prostheses with an odds ratio of 53.8. CONCLUSION The 5-year-results of the study show clinically acceptable values of mean bone loss after 5 years of loading. Implant-supported removable prostheses seem to be a strong co-factor for extensive bone level changes compared to fixed reconstructions. However, these results have to be considered for evaluation of the included special cohort under private dental office conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hintergrund Begleitverletzungen können in bis zu 90 % der Fälle nach erstmaliger Schulterluxation auftreten. Auch wenn sie nicht immer einen Einfluss auf die Therapiewahl haben, so ist eine sorgfältige Diagnostik entscheidend. Einteilung In der Akutsituation ist eine konventionelle Bildgebung in mindestens 2 Ebenen (a.-p./Neer/evtl. axial) vor und nach Reposition zwingend. Luxationsfrakturen dürfen nicht übersehen bzw. durch das Manöver der geschlossenen Reposition sekundär disloziert werden. Bestehen ossäre glenoidale, humerale oder kombinierte Verletzungen, sollten sie gemäß Stabilitätskriterien versorgt werden. Dies kann umgehend, nach manifester Dezentrierung oder Instabilität entweder mittels Osteosythese oder als glenohumerale Stabilisation im Verlauf erfolgen. Bei einer Instabilität ist prinzipiell zur Bilanzierung einer ossären Ursache das Arthro-CT die Untersuchung der Wahl, welche auch eine Beurteilung der kapsulolabroligamentären Verletzung sowie einer traumatischen Rotatorenmanschettenläsion ermöglicht. Letztere ist jedoch besser mittels Arthro-MRT zu beurteilen. Diskussion Eine signifikante frische, meist größere oder massive, Rotatorenmanschettenläsion sollte rasch operativ angegangen werden. Medial reichende „off the track“ Hill-Sachs-Läsionen können mittels einer Hill-Sachs-Remplissage oder, wie auch glenoidale Defekte, mittels einer Kochenaugmentation versorgt werden. Langzeitresultate des Latarjet-Verfahrens zeigen 25 Jahre nach dem Eingriff die niedrigste Reluxationsrate < 4 %, eine gute Außenrotation, eine sehr hohe Patientenzufriedenheit und degenerative Veränderungen, welche vergleichbar mit der natürlichen Entwicklung nach erstmaliger Schulterluxation ohne Rezidiv sind.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM To associate the dimension of the facial bone wall with clinical, radiological, and patient-centered outcomes at least 10 years after immediate implant placement with simultaneous guided bone regeneration in a retrospective study. MATERIAL AND METHODS Primary endpoint was the distance from the implant shoulder (IS) to the first bone-to-implant contact (IS-BIC10y ). Secondary endpoints included the facial bone thickness (BT10y ) 2, 4, and 6 mm apical to the IS, and the implant position. At baseline, the horizontal defect width (HDWBL ) from the implant surface to the alveolar wall was recorded. At recall, distance from the IS to the mucosal margin (IS-MM10y ), degree of soft tissue coverage of the mesial and distal aspects of the implants (PISm10y , PISd10y ; Papilla Index), pocket probing depth (PPD10y ), and patient-centered outcomes were determined. Width of the keratinized mucosa (KM), Full-Mouth Plaque and Bleeding Score (FMPS, FMBS) were available for both time points. RESULTS Of the 20 patients who underwent immediate implant placement with simultaneous guided bone regeneration and transmucosal healing, nine males and eight females with a median age of 62 years (42 min, 84 max) were followed up for a median period of 10.5 y (min 10.1 max 11.5). The 10-year implant survival rate was 100%. Multivariate regression analysis revealed a correlation of the IS-BIC10y , controlled for age and gender, with four parameters: HDWBL (P = 0.03), KMBL -10 (P = 0.02), BT10 4 mm (P = 0.01), and BT10 6 mm (P = 0.01). CONCLUSION Within the conditions of the present study, the horizontal defect width was the main indicator for the vertical dimension of the facial bone. The facial bone dimension was further associated with a reduction in the width of the keratinized mucosa and the dimension of the buccal bone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With an emphasis on systems analyses, the VSV-EBOVAC project harnesses state-of-the-art technologies that illuminate mechanisms behind the observed immunogenicity and reactogenicity of the rVSV-ZEBOV vaccine and ensures that such information is shared among stakeholders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The improvement and performance of a micellar electrokinetic capillary chromatography assay for cefepime in human serum and plasma with a 50 μm id fused-silica capillary elongated from 40 to 60 cm is reported. Sample preparation with dodecylsulfate protein precipitation at pH 4.5, the pH 9.1 separation medium and the applied voltage were as reported previously[16]. The change resulted in a significant lower current, higher resolution and increased detection time intervals. The performance of the assay with multi-level internal calibration was assessed with calibration and control samples. Quality assurance data of a two year period assessed under the new conditions demonstrated the robustness of the assay. In serum samples of patients who received both cefepime and sulfamethoxazole, cefepime could not be detected due to the inseparability of the two compounds. The presence of an interference can be recognized by an increased peak width (width > 0.2 min), the appearance of a shoulder or an unresolved double peak. The patient data gathered during a three year period reveal that introduction of therapeutic drug monitoring led to a 50% reduction of the median drug level. The data suggest that therapeutic drug monitoring can help to minimize the risk of major adverse reactions and to increase drug safety on an individual basis. This article is protected by copyright. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fission track analysis was applied to the Precambrian suites of Madagascar in order to identify the lower-temperature cooling histories and their relationships to the Phanerozoic events that affected the island. Apatite ages range from 431 to 68 Ma, and zircon ages range from 452 to 238 Ma. Thermochronologically, the island can be divided into a southern, central, and northern region each with a subdivision on an east-west basis. The southern region is sharply separated from the central region by strongly contrasting apparent apatite ages over the northwest-southeast striking Ranotsara Shear Zone (RSZ). The change in apparent ages over the RSZ is indicative of later reactivation along younger brittle faults. The central region has the oldest ages of the island and has a diffuse contact to the third region northward. Along the entire western margin of the Precambrian basement initial Paleozoic exhumation was followed by heating (burial by sediments) during Jurassic and Cretaceous times. A decrease in ages along the eastern margin from 119 to 68 Ma coincides with the predicted positions of the Marion hot spot after effects of erosion are considered. On the other hand, these ages may represent progressive opening of the margin in a southward direction together with associated denudation of the rift shoulder. The eastern part of the central region has remained very stable since at least Devonian times, undergoing only long-term very slow exhumation at rates of 1–5 m/Myr.