173 resultados para Screw Dislocation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Distraction of the periosteum results in the formation of new bone in the gap between the periosteum and the original bone. We postulate that the use of a barrier membrane would be beneficial for new bone formation in periosteal distraction. Methods: To selectively influence the contribution of the periosteum, a distraction plate with perforations was used alone or covered by a collagen barrier membrane. All animals were subjected to a 7-day latency period and a 10-day distraction period with a rate of 0.1 mm/day. Four animals per group with or without a barrier membrane were sacrificed at 2, 4, and 6 weeks after the end of the distraction. The height of new bone generated relative to the areas bound by the parent bone and the periosteum was determined by histomorphometric methods. Results: New bone was found in all groups. At the periphery of the distraction plate, significant differences in bone height were found between the hinge and the distraction screw for the group without barrier membrane at 2 weeks (0.39 ± 0.19 mm) compared to 4 weeks (0.84 ± 0.44 mm; P = 0.002) and 6 weeks (1.06 ± 0.39 mm; P = 0.004). Differences in maximum bone height with and without a barrier membrane were observed laterally to the distraction plate at 2 weeks (1.22 ± 0.64 versus 0.55 ± 0.14 mm; P = 0.019) and 6 weeks (1.61 ± 0.56 versus 0.73 ± 0.33 mm; P = 0.003) of the consolidation period. Conclusion: Within the limitations of the present study, the application of a barrier membrane may be considered beneficial for new bone formation induced by periosteal distraction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: A recent in vivo study has shown considerable contamination of internal implant and suprastructure components with great biodiversity, indicating bacterial leakage along the implant-abutment interface, abutment-prosthesis interface, and restorative margins. The goal of the present study was to compare microbiologically the peri-implant sulcus to these internal components on implants with no clinical signs of peri-implantitis and in function for many years. Checkerboard DNA-DNA hybridization was used to identify and quantify 40 species. Material and Methods: Fifty-eight turned titanium Brånemark implants in eight systemically healthy patients (seven women, one man) under regular supportive care were examined. All implants had been placed in the maxilla and loaded with a screw-retained full-arch bridge for an average of 9.6 years. Gingival fluid samples were collected from the deepest sulcus per implant for microbiological analysis. As all fixed restorations were removed, the cotton pellet enclosed in the intra-coronal compartment and the abutment screw were retrieved and microbiologically evaluated. Results: The pellet enclosed in the suprastructure was very similar to the peri-implant sulcus in terms of bacterial detection frequencies and levels for practically all the species included in the panel. Yet, there was virtually no microbial link between these compartments. When comparing the abutment screw to the peri-implant sulcus, the majority of the species were less frequently found, and in lower numbers at the former. However, a relevant link in counts for a lot of bacteria was described between these compartments. Even though all implants in the present study showed no clinical signs of peri-implantitis, the high prevalence of numerous species associated with pathology was striking. Conclusions: Intra-coronal compartments of screw-retained fixed restorations were heavily contaminated. The restorative margin may have been the principal pathway for bacterial leakage. Contamination of abutment screws most likely occurred from the peri-implant sulcus via the implant-abutment interface and abutment-prosthesis interface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nonunions of pediatric subtrochanteric femur fractures are exceedingly rare and have to date not been reported in the literature. We present the case of an 11-year-old boy who developed such a nonunion after open reduction internal fixation using a pediatric locked proximal femur plate. Using an adult proximal humerus locking plate, adequate proximal fixation of the nonunion was obtained. Furthermore, previously placed distal screw holes were safely bridged and the biomechanical environment around the nonunion site improved. Uneventful healing was possible with the use of adjuvant bone grafting. No short- or midterm complications occurred. Although other implants can certainly be adapted to a use different than that of its original design, the present case suggests that adult proximal humerus locking plates may be a safe option for revision surgery of the proximal pediatric femur.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This review covers the surgery for the bone-anchored hearing aid (Baha(®)). PREOPERATIVE WORKUP: A review of the indications and preoperative diagnostics shows that best results are generally obtained in patients with conductive or mixed hearing loss rehabilitation when surgery is not applicable or has failed and in patients that suffer from single-sided deafness. An audiogram must confirm that the bone conduction hearing is within the inclusion criteria. A computed tomography scan is performed in cases of malformation to assure sufficient bone thickness at the site of screw implantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the multidisciplinary findings in a pre-Columbian mummy head from Southern Peru (Cahuachi, Nazca civilisation, radiocarbon dating between 120 and 750 AD) of a mature male individual (40-60 years) with the first two vertebrae attached in pathological position. Accordingly, the atlanto-axial transition (C1/C2) was significantly rotated and dislocated at 38° angle associated with a bulging brownish mass that considerably reduced the spinal canal by circa 60%. Using surface microscopy, endoscopy, high-resolution multi-slice computer tomography, paleohistology and immunohistochemistry, we identified an extensive epidural hematoma of the upper cervical spinal canal-extending into the skull cavity-obviously due to a rupture of the left vertebral artery at its transition between atlas and skull base. There were no signs of fractures of the skull or vertebrae. Histological and immunohistochemical examinations clearly identified dura, brain residues and densely packed corpuscular elements that proved to represent fresh epidural hematoma. Subsequent biochemical analysis provided no evidence for pre-mortal cocaine consumption. Stable isotope analysis, however, revealed significant and repeated changes in the nutrition during his last 9 months, suggesting high mobility. Finally, the significant narrowing of the rotational atlanto-axial dislocation and the epidural hematoma probably caused compression of the spinal cord and the medulla oblongata with subsequent respiratory arrest. In conclusion, we suggest that the man died within a short period of time (probably few minutes) in an upright position with the head rotated rapidly to the right side. In paleopathologic literature, trauma to the upper cervical spine has as yet only very rarely been described, and dislocation of the vertebral bodies has not been presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Femoro-acetabular impingement can cause pain and degenerative changes of the hip joint. Traditionally, surgical dislocation of the hip joint has been performed for correction of pathologic abnormalities in the proximal part of the femur and the acetabulum. Failures of surgical treatment are often related to postoperative pain in the groin or in the area of the greater trochanter, associated with this surgical approach. The aim of our study was to determine the prevalence and functional impact of pain at the greater trochanter after surgical dislocation of the hip.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lumbopelvic distraction stabilization with (triangular osteosynthesis) or without additional iliosacral screw allows anatomic reduction of the posterior pelvic ring after severely displaced sacral fractures, correction or resection osteotomies of malunions, respectively, septic sacroiliitis and permits early weight bearing. However, this technique is complicated by wound necrosis or infection in up to 20% to 30%. We describe our experience with a less invasive technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Healed Legg-Calvé-Perthes disease may cause both intra-articular and extra-articular impingement, resulting in a symptomatic hip prior to the onset of osteoarthritis. Various impingement-relieving surgeries have been used in the past; however, the development of the safe surgical dislocation technique has allowed a better understanding of complex deformity that may be present in these hips and hence may improve treatment of these symptomatic prearthritic hips. This article outlines the range of deformities possible in a Perthes hip, and treatment strategies to surgically address these deformities. For Perthes disease good preoperative clinical and radiographic assessment is essential, and intraoperative assessment vital.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This prospective study on symptomatic adult patients with femoroacetabular impingement (FAI) who underwent open surgical intervention for management was designed to identify any obvious histological differences in the damaged acetabular cartilage within different subgroups of FAI. 20 patients underwent surgical intervention following safe surgical dislocation of the hip. There were 6 cases of cam impingement, 5 cases of pincer impingement and 9 of the mixed type. Pincer impingement cases demonstrated a characteristic focal, well-circumscribed and localized area of severe damage. On the other hand, cases with cam impingement showed a diffuse area of involvement affecting a larger surface of the acetabular cartilage, with degenerative changes, superficial erosions and some discontinuities. A small biopsy specimen of the acetabular rim including bone, cartilage and labrum from the affected zone was obtained in all cases. Histological evaluation was performed under normal and polarized light microscopy. Histological findings helped corroborate the pre-operative diagnosis and also define the unique nature of impingement and specific damage according to the type of impingement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we present a new population-based implant design methodology, which advances the state-of-the-art approaches by combining shape and bone quality information into the design strategy. The method enhances the mechanical stability of the fixation and reduces the intra-operative in-plane bending which might impede the functionality of the locking mechanism. The method is presented for the case of mandibular locking fixation plates, where the mandibular angle and the bone quality at screw locations are taken into account. Using computational anatomy techniques, the method automatically derives, from a set of computed tomography images, the mandibular angle and the bone thickness and intensity values at the path of every screw. An optimisation strategy is then used to optimise the two parameters of plate angle and screw position. Results for the new design are presented along with a comparison with a commercially available mandibular locking fixation plate. A statistically highly significant improvement was observed. Our experiments allowed us to conclude that an angle of 126° and a screw separation of 8mm is a more suitable design than the standard 120° and 9mm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients after Legg-Calvé-Perthes disease (LCPD) often develop pain, impaired ROM, abductor weakness, and progression of osteoarthritis (OA) in early adulthood. Based on intraoperative observations during surgical hip dislocation, we established an algorithm for more detailed characterization of the underlying pathomorphologies with a proposed joint-preserving surgical treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new anterior intrapelvic approach for the surgical management of displaced acetabular fractures involving predominantly the anterior column and the quadrilateral plate is described. In order to establish five 'windows' for instrumentation, the extraperitoneal space is entered along the lateral border of the rectus abdominis muscle. This is the so-called 'Pararectus' approach. The feasibility of safe dissection and optimal instrumentation of the pelvis was assessed in five cadavers (ten hemipelves) before implementation in a series of 20 patients with a mean age of 59 years (17 to 90), of whom 17 were male. The clinical evaluation was undertaken between December 2009 and December 2010. The quality of reduction was assessed with post-operative CT scans and the occurrence of intra-operative complications was noted. In cadavers, sufficient extraperitoneal access and safe instrumentation of the pelvis were accomplished. In the patients, there was a statistically significant improvement in the reduction of the fracture (pre- versus post-operative: mean step-off 3.3 mm (sd 2.6) vs 0.1 mm (sd 0.3), p < 0.001; and mean gap 11.5 mm (sd 6.5) vs 0.8 mm (sd 1.3), p < 0.001). Lesions to the peritoneum were noted in two patients and minor vascular damage was noted in a further two patients. Multi-directional screw placement and various plate configurations were feasible in cadavers without significant retraction of soft tissues. In the treatment of acetabular fractures predominantly involving the anterior column and the quadrilateral plate, the Pararectus approach allowed anatomical restoration with minimal morbidity related to the surgical access.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conclusion: A robot built specifically for stereotactic cochlear implantation provides equal or better accuracy levels together with a better integration into a clinical environment, when compared to existing approaches based on industrial robots. Objectives: To evaluate the technical accuracy of a robotic system developed specifically for lateral skull base surgery in an experimental setup reflecting the intended clinical application. The invasiveness of cochlear electrode implantation procedures may be reduced by replacing the traditional mastoidectomy with a small tunnel slightly larger in diameter than the electrode itself. Methods: The end-to-end accuracy of the robot system and associated image-guided procedure was evaluated on 15 temporal bones of whole head cadaver specimens. The main components of the procedure were as follows: reference screw placement, cone beam CT scan, computer-aided planning, pair-point matching of the surgical plan, robotic drilling of the direct access tunnel, and post-operative cone beam CT scan and accuracy assessment. Results: The mean accuracy at the target point (round window) was 0.56 ± 41 mm with an angular misalignment of 0.88 ± 0.41°. The procedural time of the registration process through the completion of the drilling procedure was 25 ± 11 min. The robot was fully operational in a clinical environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The most common techniques to perform stellate ganglion blocks (SGBs) are the blind C6 approach and the fluoroscopic-controlled paratracheal C7 approach, both after manual dislocation of the large vessels. Complications due to vascular or esophageal puncture have been reported. The goal of this ultrasound imaging study was to determine how frequently hazardous structures are located along the needle path of conventional SGB and to determine the influence of the dislocation maneuver on their position.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Image-guided microsurgery requires accuracies an order of magnitude higher than today's navigation systems provide. A critical step toward the achievement of such low-error requirements is a highly accurate and verified patient-to-image registration. With the aim of reducing target registration error to a level that would facilitate the use of image-guided robotic microsurgery on the rigid anatomy of the head, we have developed a semiautomatic fiducial detection technique. Automatic force-controlled localization of fiducials on the patient is achieved through the implementation of a robotic-controlled tactile search within the head of a standard surgical screw. Precise detection of the corresponding fiducials in the image data is realized using an automated model-based matching algorithm on high-resolution, isometric cone beam CT images. Verification of the registration technique on phantoms demonstrated that through the elimination of user variability, clinically relevant target registration errors of approximately 0.1 mm could be achieved.