109 resultados para Reported Sleep
Resumo:
The orexin system is a key regulator of sleep and wakefulness. In a multicenter, double-blind, randomized, placebo-controlled, two-way crossover study, 161 primary insomnia patients received either the dual orexin receptor antagonist almorexant, at 400, 200, 100, or 50 mg in consecutive stages, or placebo on treatment nights at 1-week intervals. The primary end point was sleep efficiency (SE) measured by polysomnography; secondary end points were objective latency to persistent sleep (LPS), wake after sleep onset (WASO), safety, and tolerability. Dose-dependent almorexant effects were observed on SE , LPS , and WASO . SE improved significantly after almorexant 400 mg vs. placebo (mean treatment effect 14.4%; P < 0.001). LPS (–18 min (P = 0.02)) and WASO (–54 min (P < 0.001)) decreased significantly at 400 mg vs. placebo. Adverse-event incidence was dose-related. Almorexant consistently and dose-dependently improved sleep variables. The orexin system may offer a new treatment approach for primary insomnia.
Resumo:
Sleep-disordered breathing (SDB) represents a risk factor for cardiovascular morbidity after a cerebral ischemic event (acute ischemic event, ischemic stroke, or transient ischemic attack). In the present study, endothelial function and arterial stiffness were analyzed in patients who experienced a postacute ischemic event with relation to SDB, sleep disruption, and nocturnal oxygenation parameters.
Resumo:
This article is aimed at addressing the current state-of-the-art in epidemiology, pathophysiology, diagnostic procedures and treatment options for appropriate management of obstructive sleep apnoea (OSA) in cardiovascular (in particular hypertensive) patients, as well as for the management of cardiovascular diseases (in particular arterial hypertension) in OSA patients. The present document is the result of work performed by a panel of experts participating in the European Union COST (Cooperation in Scientific and Technological research) Action B26 on OSA, with the endorsement of the European Respiratory Society and the European Society of Hypertension. In particular, these recommendations are aimed at reminding cardiovascular experts to consider the occurrence of sleep-related breathing disorders in patients with high blood pressure. They are also aimed at reminding respiration experts to consider the occurrence of hypertension in patients with respiratory problems at night.
Resumo:
To (a) develop the Women With Vulvar Neoplasia-Patient-Reported Outcome (WOMAN-PRO) instrument as a measure of women's post-vulvar surgery symptom experience and informational needs, (b) examine its content validity, (c) describe modifications based on pilot testing, and (d) examine the content validity of the revised instrument.
Resumo:
BACKGROUND: Adherence is one of the most crucial issues in the clinical management of HIV-infected patients receiving antiretroviral therapy (ART). METHODS: A 2-item adherence questionnaire was introduced into the Swiss HIV Cohort Study in July 2003. All 3607 eligible patients were on ART for > or =6 months and their current regimen for > or =1 month. Three definitions of nonadherence were considered: missing > or =1 dose, missing > or =2 doses, and taking <95% of doses in the past 4 weeks. RESULTS: Over 30% of patients reported missing > or =1 dose, 14.9% missed > or =2 doses, and 7.1% took <95% of doses in the previous 4 weeks. The rate of drug holidays was 5.8%. Whether using more or less conservative definitions of nonadherence, younger age, living alone, number of previous regimens, and boosted protease inhibitor regimens were independent factors associated with nonadherence. There was a significant association between optimal viral suppression and nonadherence as well as a significant linear trend in optimal viral suppression by missed doses. CONCLUSIONS: Younger age, lack of social support, and complexity of therapy are important factors that are related to nonadherence with ART. Investment in behavioral dimensions of HIV is crucial to improve adherence in ART recipients.
Resumo:
A modified uvulopalatopharyngoplasty (UPPP) was carried out between January 1992 and December 2003 at the ENT Department of the Inselspital in Bern in 146 patients with habitual or complicated rhonchopathy. The operation consisted of a classical tonsillectomy or residual tonsil resection and additional shortening of the uvula. The natural mucosal fold between the uvula and the upper pole of the tonsils was carefully preserved. A wide opening to the rhinopharynx was created by asymmetric suturing of the glossopalantine and pharyngopalatine arches. A retrospective questionnaire with regard to rhonchopathy, phases of apnea, daytime drowsiness, obstruction of nasal breathing, long-term complications and patient satisfaction was used to evaluate the short-term and long-term effectiveness of the modified UPPP as well as the incidence of adverse side effects. Complete postoperative courses were evaluated in 116 patients. Surgical complications were restricted to one case with postoperative hemorrhage. A velum insufficiency or postoperative rhinopharyngeal stenosis did not occur. Eighty-three patients (72%) confirmed a persistent suppression or substantial improvement of the rhonchopathy. Disappearance or decrease of sleep apnea was confirmed in 12 (63%) out of 19 postoperative polysomnographic follow-up investigations. Long-term complications occurred in a total of 27 (23%) of 116 patients. They were confined to minor problems such as dryness of the mouth (n = 12), slight difficulty in swallowing (n = 7), discrete speech disturbances (n = 1), and slight pharyngeal dysesthesias (n = 7) with feeling of a lump in the throat and compulsive clearing of the throat. Eighty-five patients (73%) reported that they were satisfied with the postoperative result even several years after the operation. Looking back, 31 patients (27%) would no longer have the operation performed. The inadequate result of the rhonchopathy was specified as the reason by 21 patients. Ten patients had unpleasant memories of the operation because of intensive postoperative pain. Snoring and apneic phases are suppressed or improved by non-traumatic UPPP in the majority of patients. This effect persisted even years after the operation.
Resumo:
STUDY OBJECTIVE: In healthy subjects, arousability to inspiratory resistive loading is greater during rapid eye movement (REM) sleep compared with non-REM (NREM) sleep but is poorest in REM sleep in patients with sleep apnea. We therefore examined the hypothesis that sleep fragmentation impairs arousability, especially from REM sleep. DESIGN: Two blocks of 3 polysomnographies (separated by at least 1 week) were performed randomly. An inspiratory-loaded night followed either 2 undisturbed control nights (LN(C)) or 2 acoustically fragmented nights (LN(F)) SETTING: Sleep laboratory. PARTICIPANTS: Sixteen healthy men aged 20 to 29 years. INTERVENTIONS: In both loaded nights, an inspiratory resistive load was added via a valved facemask every 2 minutes during sleep and turned off either when arousal occurred or after 2 minutes. MEASUREMENTS AND RESULTS: During LN(F), arousability remained significantly greater in REM sleep (71% aroused within 2 minutes) compared with stage 2 (29%) or stage 3/4 (16%) sleep. After sleep fragmentation, arousability was decreased in stage 2 sleep (LN(F): 29%; LN(C): 38%; p < .05) and low in early REM sleep, increasing across the night (p < .01). In stage 3/4 sleep, neither an attenuation nor a change across the night was seen after sleep fragmentation. CONCLUSIONS: Mild sleep fragmentation is already sufficient to attenuate arousability in stage 2 sleep and to decrease arousability in early, compared with late, REM sleep. This means that sleep fragmentation affects the arousal response to increasing resistance and that the effects are different in stage 2 and REM sleep. The biologic reason for this increase in the arousal response in REM sleep across the night is not clear.
Resumo:
A few publications documented the coexistence of epilepsy and obstructive sleep apnea (OSA). The extent, nature, and clinical relevance of this association remain poorly understood. We retrospectively reviewed the database of our sleep center to identify patients with both sleep apnea and epilepsy. Characteristics of epilepsy, sleep history, presence of excessive daytime sleepiness [Epworth Sleepiness Scale (ESS)] and polysomnographic data were assessed. The effect of continuous positive airway pressure (CPAP) on seizure reduction was prospectively analyzed after a median interval of 26 months (range: 2-116 months) from the diagnosis of OSA. OSA was found in 29 epilepsy patients (25 men and 4 women) with a median age of 56 years (range: 37-79). The median apnea hypopnea index was 33 (range: 10-85), the oxygen desaturation index was 12 (range 0-92), and 52% of the patients had an ESS score >10. In 27 patients, epilepsy appeared 1 month to 44 years prior to the diagnosis of OSA. In 21 patients, the appearance of OSA symptoms coincided with a clear increase in seizure frequency or the first appearance of a status epilepticus. Treatment with CPAP was continued with good compliance in 12 patients and led to a significant reduction of both ESS scores and seizure frequency in 4 patients. Our data suggest the importance of considering diagnosis and treatment of OSA in epilepsy patients with poor seizure control and/or reappearance of seizures after a seizure-free interval.
Resumo:
BACKGROUND AND PURPOSE: Sleep-disordered breathing (SDB) is frequent in stroke patients. Risk factors, treatment response, short-term and long-term outcome of SDB in stroke patients are poorly known. METHODS: We prospectively studied 152 patients (mean age 56+/-13 years) with acute ischemic stroke. Cardiovascular risk factors, Epworth sleepiness score (ESS), stroke severity/etiology, and time of stroke onset were assessed. The apnea-hypopnea index (AHI) was determined 3+/-2 days after stroke onset and 6 months later (subacute phase). Continuous positive airway pressure (CPAP) treatment was started acutely in patients with SDB (AHI > or =15 or AHI > or =10+ESS >10). CPAP compliance, incidence of vascular events, and stroke outcome were assessed 60+/-16 months later (chronic phase). RESULTS: Initial AHI was 18+/-16 (> or =10 in 58%, > or =30 in 17% of patients) and decreased in the subacute phase (P<0.001). Age, diabetes, and nighttime stroke onset were independent predictors of AHI (r2=0.34). In patients with AHI > or =30, age, male gender, body mass index, diabetes, hypertension, coronary heart disease, ESS, and macroangiopathic etiology of stroke were significantly higher/more common than in patients with AHI <10. Long-term incidence of vascular events and stroke outcome were similar in both groups. CPAP was started in 51% and continued chronically in 15% of SDB pts. Long-term stroke mortality was associated with initial AHI, age, hypertension, diabetes, and coronary heart disease. CONCLUSIONS: SDB is common particularly in elderly stroke male patients with diabetes, nighttime stroke onset, and macroangiopathy as cause of stroke; it improves after the acute phase, is associated with an increased poststroke mortality, and can be treated with CPAP in a small percentage of patients.
Resumo:
BACKGROUND AND OBJECTIVE: Sleep disturbances are prevalent but often overlooked or underestimated. We suspected that sleep disorders might be particularly common among pharmacy customers, and that they could benefit from counselling. Therefore, we described the prevalence and severity of symptoms associated with sleep and wakefulness disorders among Swiss pharmacy customers, and estimated the need for counselling and treatment. METHODS: In 804 Swiss pharmacies (49% of all community pharmacies) clients were invited to complete the Stanford Sleep Disorders Questionnaire (SDQ), and the Epworth Sleepiness Scale (EPW). The SDQ was designed to classify symptoms of sleep and wakefulness into the four most prevalent disorders: sleep apnoea syndrome (SAS), insomnia in psychiatric disorders (PSY), periodic leg movement disorders/restless legs (RLS) and narcolepsy (NAR). Data were entered into an internet-linked database for analysis by an expert system as a basis for immediate counselling by the pharmacist. RESULTS: Of 4901 participants, 3238 (66.1%) were female, and 1663 (33.9%) were male. The mean age (SD) of females and males was 52.4 (18.05), and 55.1 (17.10) years, respectively. The percentages of female and male individuals above cut-off of SDQ subscales were 11.4% and 19.8% for sleep apnoea, 40.9% and 38.7% for psychiatric sleep disorders, 59.3% and 46.8% for restless legs, and 10.4% and 9.4% for narcolepsy respectively. The prevalence of an Epworth Sleepiness Scale score >11 was 16.5% in females, and 23.9% in males. Reliability assessed by Cronbach's alpha was 0.65 to 0.78 for SDQ subscales, and for the Epworth score. CONCLUSIONS: Symptoms of sleep and wakefulness disorders among Swiss pharmacy customers were highly prevalent. The SDQ and the Epworth Sleepiness Scale score had a satisfactory reliability to be useful for identification of pharmacy customers who might benefit from information and counselling while visiting pharmacies. The internet-based system proved to be a helpful tool for the pharmacist when counselling his customers in terms of diagnostic classification and severity of symptoms associated with the sleeping and waking state.
Resumo:
BACKGROUND: In 2003 the Swiss federation of pharmacists organized a campaign "sleep disturbances--daytime sleepiness". The goal was to assist pharmacy clients in detecting likely causes of any sleep disturbance or daytime sleepiness through a free of charge screening, and to deliver targeted counselling. For pharmacy practice there are no screening or triage guidelines to assess the severity of sleep and wakefulness disturbances and potential causes for those disturbances. In this paper the outcome of the campaign in terms of feasibility, participation, observed response patterns, sale of over-the-counter (OTC) sleeping pills, and counselling activities is evaluated. METHODS: The Stanford sleep disorders questionnaire and the Epworth sleepiness scale served to identify patterns of symptoms suggestive of four major categories of sleep disorders. The questionnaires were posted on a web-site and the clients' data were entered online in the pharmacies. A report was automatically generated and immediately available online to the pharmacists. The pharmacists documented separately their counselling activities in a pharmacist's activity report. RESULTS: Six hundred and twenty-two (23%) of 2743 pharmacy clients had response patterns suggestive of obstructive sleep apnoea, 418 (15%) of restless-legs-syndrome, 39 (1%) of a sleep disorder potentially associated with a psychiatric condition and 79 (3%) of narcolepsy. An Epworth sleepiness score >10 points was found in 567 (21%). After screening, 2345 (86%) pharmacy clients received targeted counselling. Only 216 (8%) purchased an OTC sleeping pill and 704 (26%) were recommended to consult a physician, but of these, 446 (63%) were already under medical supervision. CONCLUSIONS: The online screening tool for sleep disorders and daytime sleepiness was successfully introduced in Swiss pharmacies. Pharmacies were able to assess the pattern of individual sleep disorders and to identify a possible cause in nearly one-third of the cases.
Resumo:
A prothrombotic state may contribute to the elevated cardiovascular risk in patients with obstructive sleep apnea (OSA). We investigated the relationship between apnea severity and hemostasis factors and effect of continuous positive airway pressure (CPAP) treatment on hemostatic activity. We performed full overnight polysomnography in 44 OSA patients (mean age 47+/-10 years), yielding apnea-hypopnea index (AHI) and mean nighttime oxyhemoglobin saturation (SpO2) as indices of apnea severity. For treatment, subjects were double-blind randomized to 2 weeks of either therapeutic CPAP (n = 18), 3 l/min supplemental nocturnal oxygen (n = 16) or placebo-CPAP (<1 cm H2O) (n = 10). Levels of von Willebrand factor antigen (VWF:Ag), soluble tissue factor (sTF), D-dimer, and plasminogen activator inhibitor (PAI)-1 antigen were measured in plasma pre- and posttreatment. Before treatment, PAI-1 was significantly correlated with AHI (r = 0.47, p = 0.001) and mean nighttime SpO2 (r = -0.32, p = 0.035), but these OSA measures were not significantly related with VWF:Ag, sTF, and D-dimer. AHI was a significant predictor of PAI-1 (R2 = 0.219, standardized beta = 0.47, p = 0.001), independent of mean nighttime SpO2, body mass index (BMI), and age. A weak time-by-treatment interaction for PAI-1 was observed (p = 0.041), even after adjusting for age, BMI, pre-treatment AHI, and mean SpO2 (p = 0.046). Post hoc analyses suggested that only CPAP treatment was associated with a decrease in PAI-1 (p = 0.039); there were no changes in VWF:Ag, sTF, and D-dimer associated with treatment with placebo-CPAP or with nocturnal oxygen. Apnea severity may be associated with impairment in the fibrinolytic capacity. To the extent that our sample size was limited, the observation that CPAP treatment led to a decrease in PAI-1 in OSA must be regarded as tentative.
Resumo:
OBJECTIVES: To determine whether objective measures of sleep correlate with plasma levels of the proinflammatory cytokine interleukin (IL)-6 and the procoagulant marker fibrin D-dimer in caregivers of patients with dementia. DESIGN: Cross-sectional study. SETTING: Subjects' homes. PARTICIPANTS: Sixty-four community-dwelling spousal caregivers (69% women, mean age+/-standard deviation 72+/-9) and 36 sex-matched noncaregiving controls. MEASUREMENTS: All participants underwent in-home full-night polysomnography. Demographic and lifestyle factors, depression, diseases, and medication that could affect inflammation, coagulation, and sleep were controlled for in analyses regressing sleep variables and caregiver status and their interaction on plasma levels of IL-6 and D-dimer. RESULTS: Caregivers had higher levels of D-dimer (781+/-591 vs 463+/-214 ng/mL, P=.001) and IL-6 (1.42+/-1.52 vs 0.99+/-0.86 pg/mL, P<.06) and lower levels of total sleep time (369+/-70 vs 393+/-51 minutes, P=.049) and sleep efficiency (77+/-11 vs 82+/-9%, P=.04) than controls. After controlling for age and body mass index, longer wake time after sleep onset (change in coefficient of determination (DeltaR2)=0.039, P=.04) and the interaction between caregiver status and higher apnea-hypopnea index (DeltaR2=0.054, P=.01) were predictors of IL-6. Controlling for age, caregiver status independently predicted D-dimer levels (DeltaR2=0.047, P=.01). Controlling for age and caregiver status, lower sleep efficiency (DeltaR2=0.032, P=.03) and the interaction between caregiver status and more Stage 2 sleep (DeltaR2=0.037, P=.02) independently predicted plasma D-dimer levels. CONCLUSION: Poor sleep was associated with higher plasma IL-6 and D-dimer levels. These effects were most pronounced in caregivers of subjects with Alzheimer's disease. The findings suggest a mechanism that may explain how disturbed sleep might be associated downstream with cardiovascular risk, particularly in older people under chronic stress.
Resumo:
This paper describes the results of a unique "natural experiment" of the operation and cessation of a broadcast transmitter with its short-wave electromagnetic fields (6-22 MHz) on sleep quality and melatonin cycle in a general human population sample. In 1998, 54 volunteers (21 men, 33 women) were followed for 1 week each before and after shut-down of the short-wave radio transmitter at Schwarzenburg (Switzerland). Salivary melatonin was sampled five times a day and total daily excretion and acrophase were estimated using complex cosinor analysis. Sleep quality was recorded daily using a visual analogue scale. Before shut down, self-rated sleep quality was reduced by 3.9 units (95% CI: 1.7-6.0) per mA/m increase in magnetic field exposure. The corresponding decrease in melatonin excretion was 10% (95% CI: -32 to 20%). After shutdown, sleep quality improved by 1.7 units (95% CI: 0.1-3.4) per mA/m decrease in magnetic field exposure. Melatonin excretion increased by 15% (95% CI: -3 to 36%) compared to baseline values suggesting a rebound effect. Stratified analyses showed an exposure effect on melatonin excretion in poor sleepers (26% increase; 95% CI: 8-47%) but not in good sleepers. Change in sleep quality and melatonin excretion was related to the extent of magnetic field reduction after the transmitter's shut down in poor but not good sleepers. However, blinding of exposure was not possible in this observational study and this may have affected the outcome measurements in a direct or indirect (psychological) way.