79 resultados para Q-Safe


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Small-intestine adhesiolysis can be very time consuming and may be associated with bowel wall damage. The risk for injuries to the small or large bowel resulting in increased morbidity and costs is considerable. Both efficient and gentle dissection of adhesions is important in order to avoid intraoperative perforation or, worse, postoperative intestinal leaks. We present a technique using drops of body-warm isotonic saline solution to create an edematous swelling of the adhesions. This procedure not only protects the bowel from cooling and drying, but also simplifies the dissection and, thus, lowers the risk of intestinal lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The minimally invasive approach for hysterectomy with proven benefits and lower morbidity has become the gold standard, even in women with large uterine masses. Most women with a malignant condition present with abnormal vaginal bleeding and/or suspicious imaging such that few are diagnosed by final histopathology after surgery. However, if a malignancy is not diagnosed preoperatively, intraabdominal morcellation for uterus extraction has an increased risk for potential tumor spread and peritoneal metastases, especially in cases of unexpected leiomyosarcoma. We describe a simple method to wrap the uterus in a contained environment with a plastic bag through the posterior vaginal fornix prior to conventional coring morcellation for vaginal extraction in total laparoscopic hysterectomy. We further describe our experience with a risk stratification and treatment algorithm to implement this procedure in daily routine. A video and an illustrating sketch demonstrate the simplicity and safety of the procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Paediatric supraglottic airway devices AmbuAura-i and Air-Q were designed as conduits for tracheal intubation. Although fibreoptic-guided intubation has proved successful, blind intubation as a rescue technique has never been evaluated. OBJECTIVE Evaluation of blind intubation through AmbuAura-i and Air-Q. On the basis of fibreoptic view data, we hypothesised that the success rate with the AmbuAura-i would be higher than with the Air-Q. DESIGN A prospective, randomised controlled trial with institutional review board (IRB) approval and written informed consent. SETTING University Childrens' Hospital; September 2012 to July 2014. PATIENTS Eighty children, American Society of Anesthesiologists (ASA) class I to III, weight 5 to 50 kg. INTERVENTIONS Tracheal intubation was performed through the randomised device with the tip of a fibrescope placed inside and proximal to the tip of the tracheal tube. This permitted sight of tube advancement, but without fibreoptic guidance (visualised blind intubation). MAIN OUTCOME MEASURES Primary outcome was successfully visualised blind intubation; secondary outcomes included supraglottic airway device success, insertion times, airway leak pressure, fibreoptic view and adverse events. RESULTS Personal data did not differ between groups. In contrast to our hypothesis, blind intubation was possible in 15% with the Air-Q and in 3% with the AmbuAura-i [95% confidence interval (95% CI) 6 to 31 vs. 0 to 13%; P = 0.057]. First attempt supraglottic airway device insertion success rates were 95% (Air-Q) and 100% (AmbuAura-i; 95% CI 83 to 99 vs. 91 to 100; P = 0.49). Median leak pressures were 18 cmH2O (Air-Q) and 17 cmH2O [AmbuAura-i; interquartile range (IQR) 14 to 18 vs. 14 to 19 cmH2O; P = 0.66]. Air-Q insertion was slower (27 vs. 19 s, P < 0.001). There was no difference in fibreoptic view, or adverse events (P > 0.05). In one child (Air-Q size 1.5, tube size 3.5), the tube dislocated during device removal. CONCLUSION Ventilation with both devices is reliable, but success of blind intubation is unacceptably low and cannot be recommended for elective or rescue purposes. If intubation through a paediatric supraglottic airway device is desired, we suggest that fibreoptic guidance is used. TRIAL REGISTRATION Clinicaltrials.gov identifier: NCT01692522.