83 resultados para Low threshold current densities


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Low vitamin D levels have been associated with depressive symptoms in population-based studies and non-clinical samples as well as with clinical depression. This study aimed to examine the association of vitamin D levels with the severity and dimensions of depressive symptoms in hospitalized patients with a current episode of depression taking into account confounding variables. METHODS We investigated 380 patients (mean age 47 ± 12 years, 70% women) who were consecutively hospitalized with a main diagnosis of an ICD-10 depressive episode. All patients self-rated depressive symptom severity with the Hospital Anxiety and Depression Scale (HADS-D), the Beck Depression Inventory-II (BDI-II), and the Brief Symptom Inventory. A principal component analysis was performed with all 34 items of these questionnaires and serum levels of 25-hydroxyvitamin D3 (25-OH D) were measured. RESULTS Vitamin D deficiency (< 50 nmol/l), insufficiency (50-75 nmol/l), and sufficiency (> 75 nmol/l) were present in 55.5%, 31.8% and 12.6%, respectively, of patients. Patients with vitamin D deficiency scored higher on the HADS-D scale and on an anhedonia symptom factor than those with insufficient (p-values ≤ 0.023) or sufficient (p-values ≤ 0.008) vitamin D. Vitamin D deficient patients also scored higher on the BDI-II scale than those with sufficient vitamin D (p = 0.007); BDI-II cognitive/affective symptoms, but not somatic/affective symptoms, were higher in patients with vitamin D deficiency (p = 0.005) and insufficiency (p = 0.041) relative to those with sufficient vitamin D. Effect sizes suggested clinically relevant findings. CONCLUSIONS Low vitamin D levels are frequent in hospitalized patients with a current episode of depression. Especially 25-OH D levels < 50 nmol/l were associated with cognitive/affective depressive symptoms, and anhedonia symptoms in particular.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND AIMS Smoking is a crucial environmental factor in inflammatory bowel disease [IBD]. However, knowledge on patient characteristics associated with smoking, time trends of smoking rates, gender differences and supportive measures to cease smoking provided by physicians is scarce. We aimed to address these questions in Swiss IBD patients. METHODS Prospectively obtained data from patients participating in the Swiss IBD Cohort Study was analysed and compared with the general Swiss population [GSP] matched by age, sex and year. RESULTS Among a total of 1770 IBD patients analysed [49.1% male], 29% are current smokers. More than twice as many patients with Crohn's disease [CD] are active smokers compared with ulcerative colitis [UC] [UC, 39.6% vs CD 15.3%, p < 0.001]. In striking contrast to the GSP, significantly more women than men with CD smoke [42.8% vs 35.8%, p = 0.025], with also an overall significantly increased smoking rate compared with the GSP in women but not men. The vast majority of smoking IBD patients [90.5%] claim to never have received any support to achieve smoking cessation, significantly more in UC compared with CD. We identify a significantly negative association of smoking and primary sclerosing cholangitis, indicative of a protective effect. Psychological distress in CD is significantly higher in smokers compared with non-smokers, but does not differ in UC. CONCLUSIONS Despite well-established detrimental effects, smoking rates in CD are alarmingly high with persistent and stagnating elevations compared with the GSP, especially in female patients. Importantly, there appears to be an unacceptable underuse of supportive measures to achieve smoking cessation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the role of an ultra-low-dose dual-source CT coronary angiography (CTCA) scan with high pitch for delimiting the range of the subsequent standard CTCA scan. METHODS 30 patients with an indication for CTCA were prospectively examined using a two-scan dual-source CTCA protocol (2.0 × 64.0 × 0.6 mm; pitch, 3.4; rotation time of 280 ms; 100 kV): Scan 1 was acquired with one-fifth of the tube current suggested by the automatic exposure control software [CareDose 4D™ (Siemens Healthcare, Erlangen, Germany) using 100 kV and 370 mAs as a reference] with the scan length from the tracheal bifurcation to the diaphragmatic border. Scan 2 was acquired with standard tube current extending with reduced scan length based on Scan 1. Nine central coronary artery segments were analysed qualitatively on both scans. RESULTS Scan 2 (105.1 ± 10.1 mm) was significantly shorter than Scan 1 (127.0 ± 8.7 mm). Image quality scores were significantly better for Scan 2. However, in 5 of 6 (83%) patients with stenotic coronary artery disease, a stenosis was already detected in Scan 1 and in 13 of 24 (54%) patients with non-stenotic coronary arteries, a stenosis was already excluded by Scan 1. Using Scan 2 as reference, the positive- and negative-predictive value of Scan 1 was 83% (5 of 6 patients) and 100% (13 of 13 patients), respectively. CONCLUSION An ultra-low-dose CTCA planning scan enables a reliable scan length reduction of the following standard CTCA scan and allows for correct diagnosis in a substantial proportion of patients. ADVANCES IN KNOWLEDGE Further dose reductions are possible owing to a change in the individual patient's imaging strategy as a prior ultra-low-dose CTCA scan may already rule out the presence of a stenosis or may lead to a direct transferal to an invasive catheter procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The complex relation between thrombotic thrombocytopenic purpura (TTP) and pregnancy is concisely reviewed. Pregnancy is a very strong trigger for acute disease manifestation in patients with hereditary TTP caused by double heterozygous or homozygous mutations of ADAMTS13 (ADisintegrin And Metalloprotease with ThromboSpondin type 1 domains, no. 13). In several affected women disease onset during their first pregnancy leads to the diagnosis of hereditary TTP. Without plasma treatment mother and especially fetus are at high risk of dying. The relapse risk during a next pregnancy is almost 100% but regular plasma transfusion starting in early pregnancy will prevent acute TTP flare-up and may result in successful pregnancy outcome. Pregnancy may also constitute a mild risk factor for the onset of acute acquired TTP caused by autoantibody-mediated severe ADAMTS13 deficiency. Women having survived acute acquired TTP may not be at very high risk of TTP relapse during an ensuing next pregnancy but seem to have an elevated risk of preeclampsia. Monitoring of ADAMTS13 activity and inhibitor titre during pregnancy may help to guide management and to avoid disease recurrence. Finally, TTP needs to be distinguished from the much more frequent hypertensive pregnancy complications, preeclampsia and especially HELLP (Hemolysis, Elevated Liver Enzymes, Low Platelet count) syndrome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The accurate electron density distribution and magnetic properties of two metal-organic polymeric magnets, the quasi-one-dimensional (1D) Cu(pyz)(NO3)2 and the quasi-two-dimensional (2D) [Cu(pyz)2(NO3)]NO3·H2O, have been investigated by high-resolution single-crystal X-ray diffraction and density functional theory calculations on the whole periodic systems and on selected fragments. Topological analyses, based on quantum theory of atoms in molecules, enabled the characterization of possible magnetic exchange pathways and the establishment of relationships between the electron (charge and spin) densities and the exchange-coupling constants. In both compounds, the experimentally observed antiferromagnetic coupling can be quantitatively explained by the Cu-Cu superexchange pathway mediated by the pyrazine bridging ligands, via a σ-type interaction. From topological analyses of experimental charge-density data, we show for the first time that the pyrazine tilt angle does not play a role in determining the strength of the magnetic interaction. Taken in combination with molecular orbital analysis and spin density calculations, we find a synergistic relationship between spin delocalization and spin polarization mechanisms and that both determine the bulk magnetic behavior of these Cu(II)-pyz coordination polymers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

UNLABELLED Evidence for target values of arterial oxygen saturation (SaO2), CO2, and pH has changed substantially over the last 20 years. A representative survey concerning treatment strategies in extremely low-birth-weight infants (ELBW) was sent to all German neonatal intensive care units (NICUs) treating ELBW infants in 1997. A follow-up survey was conducted in 2011 and sent to all NICUs in Germany, Austria, and Switzerland. During the observation period, NICUs targeting SaO2 of 80, 85, and 90 % have increased, while units aiming for 94 and 96 % decreased (all p < 0.001). Similarly, NICUs aiming for pH 7.25 or lower increased, while 7.35 or higher decreased (both p < 0.001). Furthermore, more units targeted a CO2 of 50 mmHg (7.3 kPa) or higher (p < 0.001), while fewer targeted 40 or 35 mmHg (p < 0.001). Non-invasive ventilation (NIV) was used in 80.2 % of NICUs in 2011. The most frequently used ventilation modes were synchronized intermittent mandatory ventilation (SIMV) (67.5 %) and intermittent positive pressure ventilation (IPPV) (59.7 %) in 1997 and SIMV (77.2 %) and synchronized intermittent positive pressure ventilation (SIPPV) (26.8 %) in 2011. NICUs reporting frequent or always use of IPPV decreased to 11.0 % (p < 0.001). SIMV (77.2 %) and SIPPV (26.8 %) did not change from 1997 to 2011, while high-frequency oscillation (HFO) increased from 9.1 to 19.7 % (p = 0.018). Differences between countries, level of care, and size of the NICU were minimal. CONCLUSIONS Target values for SaO2 decreased, while CO2 and pH increased significantly during the observation period. Current values largely reflect available evidence at time of the surveys. WHAT IS KNOWN • Evidence concerning target values of oxygen saturation, CO 2 , and pH in extremely low-birth-weight infants has grown substantially. • It is not known to which extent this knowledge is transferred into clinical practice and if treatment strategies have changed. WHAT IS NEW • Target values for oxygen saturation in ELBW infants decreased between 1997 and 2011 while target values for CO 2 and pH increased. • Similar treatment strategies existed in different countries, hospitals of different size, or university versus nonuniversity hospitals in 2011.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Uncertainty about the presence of infection results in unnecessary and prolonged empiric antibiotic treatment of newborns at risk for early-onset sepsis (EOS). This study evaluates the impact of this uncertainty on the diversity in management. METHODS A web-based survey with questions addressing management of infection risk-adjusted scenarios was performed in Europe, North America, and Australia. Published national guidelines (n=5) were reviewed and compared to the results of the survey. RESULTS 439 Clinicians (68% were neonatologists) from 16 countries completed the survey. In the low-risk scenario, 29% would start antibiotic therapy and 26% would not, both groups without laboratory investigations; 45% would start if laboratory markers were abnormal. In the high-risk scenario, 99% would start antibiotic therapy. In the low-risk scenario, 89% would discontinue antibiotic therapy before 72 hours. In the high-risk scenario, 35% would discontinue therapy before 72 hours, 56% would continue therapy for five to seven days, and 9% for more than 7 days. Laboratory investigations were used in 31% of scenarios for the decision to start, and in 72% for the decision to discontinue antibiotic treatment. National guidelines differ considerably regarding the decision to start in low-risk and regarding the decision to continue therapy in higher risk situations. CONCLUSIONS There is a broad diversity of clinical practice in management of EOS and a lack of agreement between current guidelines. The results of the survey reflect the diversity of national guidelines. Prospective studies regarding management of neonates at risk of EOS with safety endpoints are needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Investigations on antimatter allow us to shed light on fundamental issues of contemporary physics. The only antiatom presently available, antihydrogen, is produced making use of the Antiproton Decelerator (AD) facility at CERN. International collaborations currently on the floor (ALPHA, ASACUSA and ATRAP) have succeeded in producing antihydrogen and are now involved in its confinement and manipulation. The AEGIS experiment is currently completing the commissioning of the apparatus which will generate and manipulate antiatoms. The present paper, after a report on the main results achieved with antihydrogen physics, gives an overview of the AEGIS experiment, describes its current status and discusses its first target.