148 resultados para ENDOSCOPIC TRACHEAL OCCLUSION


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The objective of this study was to investigate the feasibility, outcomes, and amount of small intestinal submucosa (SIS) material needed for embolization of jugular vein (JV) in a swine and sheep model. Our hypothesis was that SIS would cause vein occlusion. MATERIALS AND METHODS: The external JVs (EJV) in swine (n = 6) and JVs in sheep (n = 6) were occluded with SIS fan-folded compressed strips. After percutaneous puncture of the peripheral portion of the EJV or JV, a TIPS set was used to exit their lumen centrally through the skin. The SIS strips were delivered into the isolated venous segment with a pull-through technique via a 10-Fr sheath. Follow-up venograms were done immediately after placement and at the time of sacrifice at 1 or 3 months. Gross examinations focused on the EJV or JV and their surrounding structures. Specimens were evaluated by histology. RESULTS: SIS strip(s) placement was successful in all cases, with immediate vein occlusion seen in 23 of 24 veins (95.8%). All EJVs treated with two strips and all JVs treated with three or four strips remained closed on 1- and 3-month follow-up venograms. Two EJVs treated with one strip and one JV treated with two strips were partially patent on venograms at 1 and 3 months. There has been one skin inflammatory reaction. Necropsies revealed excluded EJV or JV segments with SIS incorporation into the vein wall. Histology demonstrated various stages of SIS remodeling with fibrocytes, fibroblasts, endothelial cells, capillaries, and inflammatory cells. CONCLUSION: We conclude that EJV and JV ablation with SIS strips using percutaneous exit catheterization is feasible and effective in animal models. Further exploration of SIS as vein ablation material is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Although mechanical thrombectomy (MT) has an encouragingly high recanalization rate in treating stroke, it is associated with severe complications of which the underlying factors have yet to be identified. Because MT is a mechanical approach, the mechanical properties of the thrombus might be crucial for its success. The present study assesses the effect of thrombus length on the in vivo effectiveness and complication rate of MT. MATERIALS AND METHODS: Angiography and embolization of 21 cranial vessels with radiopaque whole-blood thrombi 10, 20, and 40 mm in length (7 occlusions each) were performed in 7 swine. MT was carried out using a distal snarelike device (BCR Roadsaver) with proximal balloon occlusion. A total of 61 retrievals were attempted. RESULTS: In the group of 10-mm occlusions, 77.8% of the attempts achieved complete recanalisation. For longer occlusions, the success rates decreased significantly to 20% of attempts for 20-mm occlusions (odds ratio [OR], 14; 95% confidence interval [CI], 2.2-89.2) and 11.1% for 40-mm occlusions (OR, 28; 95% CI, 3.9-202.2; P < .005). The low success rates were largely due to complications associated with thrombus compaction during retrieval. Similarly, the rate of thromboembolic events increased from 0% in 10-mm occlusions to 14.8% in 40-mm occlusions. CONCLUSIONS: MT using a distal device proved to be a fast, effective, and safe procedure for recanalizing short (10-mm) occlusions in the animal model. However, occlusion length emerged as a crucial determinant for MT with a significant decrease in recanalization success per attempt and increased complication rates. These findings suggest limitations of MT in the clinical application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: For selected stroke patients, intra-arterial thrombolysis (IAT) has been shown to be an effective treatment option. However, knowledge of safety and efficacy of IAT in patients with acute stroke as a complication of arterial catheter interventions is limited. METHODS: We analyzed clinical radiological findings and functional outcomes in consecutive patients 3 months after treatment with IAT for peri-procedural strokes occurring during neuroendovascular or cardiac catheter interventions. To measure outcome, the modified Rankin scale score was used. RESULTS: Of a total of 432 patients treated with IAT, 12 (4 women and 8 men; mean age, 60 years) were treated because of an ischemic stroke after a neuro-endovascular procedure (n=6) or coronary angiography (n=6). The median baseline National Institutes of Health Stroke Scale score was 15. Recanalization was complete (thrombolysis in myocardial infarction grade 3) in 6, partial (thrombolysis in myocardial infarction 2) in 5, and minimal (thrombolysis in myocardial infarction 1) in 1. Nine patients (75%) had a favorable outcome (modified Rankin scale score, 0 to 2), and 3 had a poor outcome (modified Rankin scale score, 3 or 4). All patients with complete recanalization had a favorable outcome, whereas only 3 of 6 patients with partial or minimal recanalization (P=0.18) had a favorable outcome. Follow-up brain imaging was normal in 2 and showed new ischemic lesions in 10 patients. Two patients (17%) had a symptomatic intracerebral hemorrhage. CONCLUSIONS: In acute stroke attributable to arterial catheter interventions, IAT is feasible and has the potential to improve outcome in these patients. A high recanalization rate could be achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The use of vascular plug devices for the occlusion of high-flow lesions is a relatively new and successful procedure in peripheral and cardiopulmonary interventions. We report on the use and efficiency of the Amplatzer vascular plug in a small clinical series and discuss its potential for occlusion of large vessels and high-flow lesions in neurointerventions. METHODS: Between 2005 and 2007 four patients (mean age 38.5 years, range 16-62 years) were treated with the device, in three patients to achieve parent artery occlusion of the internal carotid artery, in one patient to occlude a high-flow arteriovenous fistula of the neck. The application, time to occlusion, and angiographic and clinical results and the follow-up were evaluated. RESULTS: Navigation, positioning and detachment of the device were satisfactory in all cases. No flow-related migration of the plug was seen. The cessation of flow was delayed by a mean of 10.5 min after deployment of the first device. In the procedures involving vessel sacrifice, two devices had to be deployed to achieve total occlusion. No patient experienced new neurological deficits; the 3-month follow-up revealed stable results. CONCLUSION: The Amplatzer vascular plug can be adapted for the treatment of high-flow lesions and parent artery occlusions in the head and neck. In this small series the use of the devices was uncomplicated and safe. The rigid and large delivery device and the delayed cessation of flow currently limit the device's use in neurointerventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Computer-assisted navigation is increasingly used in functional endoscopic sinus surgery (FESS) to prevent injury to vital structures, necessitating preparative CT and, thus, radiation exposure. The purpose of our study was to investigate currently used radiation doses for CT in computer-assisted navigation in sinus surgery (CAS-CT) and to assess minimal doses required. MATERIALS AND METHODS: A questionnaire inquiring about dose parameters used for CAS-CT was sent to 30 radiologic institutions. The feasibility of low-dose registration was tested with a phantom. The influence of CAS-CT dose on technical accuracy and on the practical performance of 5 ear, nose, and throat (ENT) surgeons was evaluated with cadaver heads. RESULTS: The questionnaire response rate was 63%. Variation between minimal and maximal dose used for CAS-CT was 18-fold. Phantom registration was possible with doses as low as 1.1 mGy. No dose dependence on technical accuracy was found. ENT surgeons were able to identify anatomic landmarks on scans with a dose as low as 3.1 mGy. CONCLUSIONS: The vast dose difference between institutions mirrors different attitudes toward image quality and radiation-protection issues rather than being technically founded, and many patients undergo CAS-CT at higher doses than necessary. The only limit for dose reduction in CT for computer-assisted endoscopic sinus surgery is the ENT surgeon's ability to cope with impaired image quality, whereas there is no technically justified lower dose limit. We recommend, generally, doses used for the typical diagnostic low-dose sinus CT (120 kV/20-50 mAs). When no diagnostic image quality is needed, even a reduction down to a third is possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stent placement has been applied in small case series as a rescue therapy in combination with different thrombolytic agents, percutaneous balloon angioplasty (PTA), and mechanical thromboembolectomy (MT) in acute stroke treatment. These studies report a considerable mortality and a high rate of intracranial hemorrhages when balloon-mounted stents were used. This study was performed to evaluate feasibility, efficacy, and safety of intracranial artery recanalization for acute ischemic stroke using a self-expandable stent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare the risk of shunt-dependent hydrocephalus after treatment of ruptured intracranial aneurysms by clipping versus coiling. METHODS: We analyzed 596 patients prospectively added to our database from July of 1999 to November of 2005 concerning the risk of shunt dependency after clipping versus coiling. Factors analyzed included age; sex; Hunt and Hess grade; Fisher grade; acute hydrocephalus; intraventricular hemorrhage; angiographic vasospasm; and number, size, and location of aneurysms. In addition, a meta-analysis of available data from the literature was performed identifying four studies with quantitative data on the frequency of clip, coil, and shunt dependency. RESULTS: The institutional series revealed Hunt and Hess grade, Fisher grade, acute hydrocephalus, intraventricular hemorrhage, and angiographic vasospasm as significant (P < 0.05) risk factors for shunt dependency after a univariate analysis. In a multivariate logistic regression analysis, we isolated intraventricular hemorrhage, acute hydrocephalus, and angiographic vasospasm as independent, significant risk factors for shunt dependency. The meta-analysis, including the current data, revealed a significantly higher risk for shunt dependency after coiling than after clipping (P = 0.01). CONCLUSION: Clipping of a ruptured aneurysm may be associated with a lower risk for developing shunt dependency, possibly by clot removal. This might influence long-term outcome and surgical decision making.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During endoscopic surgery, it is difficult to ascertain the anatomical landmarks once the anatomy is fiddled with or if the operating area is filled with blood. An augmented reality system will enhance the endoscopic view and further enable surgeons to view hidden critical structures or the results of preoperative planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Initial presentation of a white female newborn delivered after normal pregnancy demonstrated a white mass obstructing the left nare. Primary biopsy revealed a focus of fibrotic nasal mucosa that included squamous and respiratory epithelium. After endoscopic resection of the mass, histopathologic examination resulted in the diagnosis of a teratoma. According to our literature review, this is the first case of a teratoma arising from the nasal septum in a white. Worldwide, 3 additional cases have been reported, but none included endoscopic management. This case illustrates our protocol for an endoscopic approach to an obstructive nasal mass in a neonate and our experience in the management of this rare disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Branch retinal vein occlusion is a frequent cause of visual loss with currently insufficient treatment options. We evaluate the effect of Bevacizumab (Avastin) treatment in patients with macular edema induced by branch retinal vein occlusion.