103 resultados para ELECTROMAGNETIC DEVICES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

About 500,000 elderly people in Switzerland suffer a fall each year. Thus medical attention and help are essential for these people, who mostly live alone without a caregiver. Only 3% of people aged over 65 in Switzerland use an emergency system. Personal telehealth devices allow patients to receive enough information about the appropriate treatment, as well as followup with their doctors and reports of any emergency, in the absence of any caregiver. This increases their quality of life in a cost-effective fashion. "Limmex"-a new medical emergency watch-was launched in Switzerland in 2011 and has been a great commercial success. In this paper, we give a brief review of this watch technology, along with the results of a survey of 620 users conducted by the Department of Emergency Medicine in Bern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Acupuncture is a complex intervention consisting of specific and non-specific components. Acupuncture studies more frequently focus on collecting data from the patients’ perspective and response, but the acupuncturist’s role remains relatively unclear. In order to investigate potential non-mechanical active factors originating from the acupuncturist and transmitted to the patient during treatment, two novel devices for basic research in acupuncture were designed. The Acuplicator allows the researcher to insert needles without touching the needles themselves, while the Veliusator locks the needle in its place so that no mechanical movement can be transferred. METHODS: The Acuplicator was used to insert needles at Neiguan (PC6) on the right forearm of 23 volunteers. The insertion depth was measured using a depth gauge. The transfer of mechanical movements from the handle to the tip was detected with a precision length gauge with a motoric-tactile sensor. RESULTS: The mean insertion depth was (12.3 ± 1.5) mm (range 9.5 to 15.0 mm). Even with intense manipulation of the needle handle, no movements within ± 1 μm could be detected at the tip when the needle was locked. CONCLUSION: With these two devices it will be possible to investigate the influence of non-mechanical components such as therapeutic qi in acupuncture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: High dilutions of various starting materials, e.g. copper sulfate, Hypericum perforatum and sulfur, showed significant differences from controls and amongst different dilution levels in ultraviolet light (UV) transmission [1,2]. Exposure of high dilutions to external physical factors such as UV light or elevated temperature (37°C) also yielded significantly different UV transmissions compared to unexposed dilutions [2,3]. In a study with highland frogs it was shown that animals incubated with thyroxine 30c but not with thyroxine 30c exposed to electromagnetic fields (EMFs) of a microwave oven or mobile phone metamorphosed more slowly than control animals [4]. Aims: The aim was to test whether the EMF of a mobile phone influences the UV absorbance of dilutions of quartz and Atropa belladonna (AB). Methodology: Commercially available dilutions of 6x, 12x, 15x, 30x in H2O and 19% ethanol of quartz (SiO2) and of 4x, 6x, 12x, 15x, 30x in H2O and 19% ethanol of AB were used in the experiments (Weleda AG, Arlesheim, Switzerland). Four samples of each dilution were exposed to the EMF of a mobile phone (Philips, Savvy Dual Band) at 900 MHz with an output of 2 W for 3 h, while control samples (4 of each dilution) were kept in a separate room. Absorbance of the samples in the UV range (from 190 to 340 nm) was measured in a randomized order with a Shimadzu UV-1800 spectrophotometer equipped with an auto sampler. In total 5 separate measurement days will be carried out for quartz and for AB dilutions. The average absorbance from 200 to 340 nm and from 200 to 240 nm was compared among dilution levels using a Kruskal-Wallis test and between exposed and unexposed samples using a Mann-Whitney-U test. Results: Preliminary results after 2 measurement days indicated that for quartz the absorbance of the various dilution levels was different from each other (except 12x and 15x), and that samples exposed to an EMF did not show a difference in UV absorbance from unexposed samples. Preliminary results after one measurement day indicated that for AB the absorbance of the various dilution levels was different from each other. The samples exposed to an EMF did not show a difference in UV absorbance from unexposed samples (except 4x in the range from 200 – 240 nm). Conclusions: These results suggest that exposure of high dilutions of quartz and AB to a mobile phone EMF as used here does not alter UV absorbance of these dilutions. The final results will show whether this holds true.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: In homeopathy or anthroposophically extended medicine high dilutions are used. They showed significant differences in ultraviolet light (UV) transmission between controls and different dilution levels. Exposing such dilutions to physical factors such as UV light or elevated temperature (37�C) yielded significantly different UV transmissions values compared to unexposed dilutions. The aim was to test whether electromagnetic fields (EMF) of a mobile phone affect the UV absorbance of dilutions of Atropa belladonna (Ab) and quartz. Methods: Commercially available dilutions of Ab 4x, 6x, 12x, 15x, 30x and of quartz 6x, 12x, 15x, 30x were investigated. On 5 days, 4 samples of each dilution were exposed to the EMF by a mobile phone at 900MHz (GSM) with an output power of 2W for 3 h. Control samples were kept in a separate room. UV-absorbance of the samples in the range from 190 to 340 nm was measured in randomized order. The average absorbance from 200 to 340 nm and from 200 to 240 nm was compared between exposed and unexposed samples by a dependent t-test. Results: Between unexposed and exposed dilutions of Ab and quartz no significant differences were detected, except for quartz 12x over the range from 200 to 340 nm. Conclusion: Exposure of high dilutions of Ab and quartz to GSM EMF of a mobile phone did not alter UV absorbance of these dilutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the first analysis of the input impedance and radiation properties of a dipole antenna, placed on top of Fan 's three-dimensional electromagnetic bandgap (EBG) structure, (Applied Physics Letters, 1994) constructed using a high dielectric constant ceramic. The best position of the dipole on the EBG surface is determined following impedance and radiation pattern analyses. Based on this optimum configuration an integrated Schottky heterodyne detector was designed, manufactured and tested from 0.48 to 0.52 THz. The main antenna features were not degraded by the high dielectric constant substrate due to the use of the EBG approach. Measured radiation patterns are in good agreement with the predicted ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract. During the last decade mobile communications increasingly became part of people's daily routine. Such usage raises new challenges regarding devices' battery lifetime management when using most popular wireless access technologies, such as IEEE 802.11. This paper investigates the energy/delay trade-off of using an end-user driven power saving approach, when compared with the standard IEEE 802.11 power saving algorithms. The assessment was conducted in a real testbed using an Android mobile phone and high-precision energy measurement hardware. The results show clear energy benefits of employing user-driven power saving techniques, when compared with other standard approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Equipped with state-of-the-art smartphones and mobile devices, today's highly interconnected urban population is increasingly dependent on these gadgets to organize and plan their daily lives. These applications often rely on current (or preferred) locations of individual users or a group of users to provide the desired service, which jeopardizes their privacy; users do not necessarily want to reveal their current (or preferred) locations to the service provider or to other, possibly untrusted, users. In this paper, we propose privacy-preserving algorithms for determining an optimal meeting location for a group of users. We perform a thorough privacy evaluation by formally quantifying privacy-loss of the proposed approaches. In order to study the performance of our algorithms in a real deployment, we implement and test their execution efficiency on Nokia smartphones. By means of a targeted user-study, we attempt to get an insight into the privacy-awareness of users in location-based services and the usability of the proposed solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To compare clinical outcome of Amplatzer PFO (APFO) to Cardia PFO (CPFO) occluder. Percutaneous patent foramen ovale (PFO) closure prevents stroke recurrence in stroke due to paradoxical embolism. Methods and results: The primary endpoint was a composite of stroke, TIA, or peripheral embolism at follow-up. The secondary endpoint was residual shunt. Outcome was compared among 934 (APFO: 712; CPFO: 222) patients, and in 297 propensity score-matched patients. The primary endpoint occurred in 29 patients (0.71/100 patient-years): four (2%) with the CPFO (0.31/100 patient-years), and 25 (4%) with the APFO (0.89/100 patient-years) (p=0.20). Residual shunt at six months was more frequent with the CPFO (31% versus 9%, p<0.001). No differences in residual shunts were seen at the last available echocardiographic follow-up (9±18 months): APFO 11%, CPFO 14%, p=0.22. Conclusions: This study suggests that PFO closure with APFO or CPFO is equally effective for the prevention of recurrent events. Residual shunt was more frequent at six months with CPFO, but was similar to APFO at later follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Upconverter materials and upconverter solar devices were recently investigated with broad-band excitation revealing the great potential of upconversion to enhance the efficiency of solar cell at comparatively low solar concentration factors. In this work first attempts are made to simulate the behavior of the upconverter β-NaYF4 doped with Er3+ under broad-band excitation. An existing model was adapted to account for the lower absorption of broader excitation spectra. While the same trends as observed for the experiments were found in the simulation, the absolute values are fairly different. This makes an upconversion model that specifically considers the line shape function of the ground state absorption indispensable to achieve accurate simulations of upconverter materials and upconverter solar cell devices with broadband excitations, such as the solar radiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We calculate the O(αs) corrections to the double differential decay width dΓ77/(ds1ds2) for the process B¯→Xsγγ, originating from diagrams involving the electromagnetic dipole operator O7. The kinematical variables s1 and s2 are defined as si=(pb−qi)2/m2b, where pb, q1, q2 are the momenta of the b quark and two photons. We introduce a nonzero mass ms for the strange quark to regulate configurations where the gluon or one of the photons become collinear with the strange quark and retain terms which are logarithmic in ms, while discarding terms which go to zero in the limit ms→0. When combining virtual and bremsstrahlung corrections, the infrared and collinear singularities induced by soft and/or collinear gluons drop out. By our cuts the photons do not become soft, but one of them can become collinear with the strange quark. This implies that in the final result a single logarithm of ms survives. In principle, the configurations with collinear photon emission could be treated using fragmentation functions. In a related work we find that similar results can be obtained when simply interpreting ms appearing in the final result as a constituent mass. We do so in the present paper and vary ms between 400 and 600 MeV in the numerics. This work extends a previous paper by us, where only the leading power terms with respect to the (normalized) hadronic mass s3=(pb−q1−q2)2/m2b were taken into account in the underlying triple differential decay width dΓ77/(ds1ds2ds3).