125 resultados para Cortex Preservation
Resumo:
Prolongation of the safe period of ischemia of the heart is an efficient way to overcome donor organ shortage, as demonstrated in renal and hepatic transplantation. We present the results of a prospective, randomized study comparing preservation with University of Wisconsin solution (UWS) versus St. Thomas' Hospital solution (STS) in clinical heart transplantation. A total of 39 patients were enrolled in the study (n = 20 for UWS and n = 19 for STS). Hemodynamic, electron microscopic, and biochemical evaluation did not reveal any significant differences in postoperative myocardial performance. Only the number of intraoperative defibrillations (0.82 for UWS versus 1.7 for STS) and the rhythm stability after reperfusion (13/20 UWS hearts versus 6/19 STS hearts in sinus rhythm) were significantly different. Heart preservation with UWS and STS appears to be of comparable efficacy at mean ischemic times of less than 4 hours.
Resumo:
In recent years, there is a growing body of evidence that the University of Wisconsin (UW) solution offers many advantages in organ preservation with regard to preservation quality and time. We, therefore, conducted the first European prospective, randomized, clinical trial comparing myocardial performance after preservation with UW and St. Thomas Hospital (ST) solution. Preliminary results indicated superior heart function after preservation with UW solution.
Resumo:
Metanephric adenoma (MA) is a rare renal neoplasm present at any age. Usually, a total nephrectomy is performed. Some successful partial nephrectomies or selective tumor resections are described in adults but not in children. We present here the case of a 15-month-old boy, the youngest patient yet to be reported with an MA. We performed a local resection of the tumor. Today, 2 1/2 years after surgery, we can document a favorable clinical course and normal ultrasound findings in the follow-up of the operated kidney. This case gives further evidence that organ-sparing resection of MA is feasible in selected cases. A close clinical and ultrasound follow-up is mandatory for this approach.
Resumo:
PURPOSE: The aim of this review was to evaluate the techniques and outcomes of postextraction ridge preservation and the efficacy of these procedures in relation to subsequent implant placement. MATERIALS AND METHODS: A MEDLINE/PubMed search was conducted and the bibliographies of reviews from 1999 to March 2008 were assessed for appropriate studies. Randomized clinical trials, controlled clinical trials, and prospective/retrospective studies with a minimum of five patients were included. RESULTS: A total of 135 abstracts were identified, from which 53 full-text articles were further examined, leading to 37 human studies that fulfilled the search criteria. Many different techniques, methodologies, durations, and materials were presented in the publications reviewed, making direct comparison difficult. CONCLUSIONS: Despite the heterogeneity of the studies, it was concluded that ridge preservation procedures are effective in limiting horizontal and vertical ridge alterations in postextraction sites. There is no evidence to support the superiority of one technique over another. There is also no conclusive evidence that ridge preservation procedures improve the ability to place implants.
Resumo:
We have quantitated the degree of structural preservation in cryo-sections of a vitrified biological specimen. Previous studies have used sections of periodic specimens to assess the resolution present, but preservation before sectioning was not assessed and so the damage due particularly to cutting was not clear. In this study large single crystals of lysozyme were vitrified and from these X-ray diffraction patterns extending to better than 2.1A were obtained. The crystals were high pressure frozen in 30% dextran, and cryo-sectioned using a diamond knife. In the best case, preservation to a resolution of 7.9A was shown by electron diffraction, the first observation of sub-nanometre structural preservation in a vitreous section.
Resumo:
Especially young women with cancer face rising survival rates due to remarkable progress in oncologic therapies. Preserving fertility is a major concern for both patients and their next of kin. Well established reproductive technologies such as cryopreservation of fertilized oocytes after in vitro fertilization already make fertility preservation possible for some patients. This review is dedicated to the emerging techniques that are becoming widely accepted for fertility preservation in young women and girls with cancer, such as auto transplantation of ovarian tissue cryopreservation and in vitro maturation (IVM) of either oocytes or follicles. First results are encouraging. But some challenges still have to be tackled in order for these novel technologies to be routinely employed with the aim of successful fertility preservation.
Resumo:
Recent studies suggest that lucid dreaming (awareness of dreaming while dreaming) might be associated with increased brain activity over frontal regions during rapid eye movement (REM) sleep. By applying transcranial direct current stimulation (tDCS), we aimed to manipulate the activation of the dorsolateral prefrontal cortex (DLPFC) during REM sleep to induce lucid dreaming. Nineteen participants spent three consecutive nights in a sleep laboratory. On the second and third nights they randomly received either 1 mA tDCS for 10 min or sham stimulation during each REM period starting with the second one. According to the participants' self-ratings, tDCS over the DLPFC during REM sleep increased lucidity in dreams. The effects, however, were not strong and found only in frequent lucid dreamers. While this indicates some preliminary support for the involvement of the DLPFC in lucid dreaming, further research, controlling for indirect effects of stimulation and including other brain regions, is needed.
Resumo:
Repetitive transcranial magnetic stimulation (rTMS) is a novel research tool in neurology and psychiatry. It is currently being evaluated as a conceivable alternative to electroconvulsive therapy for the treatment of mood disorders. Eight healthy young (age range 21-25 years) right-handed men without sleep complaints participated in the study. Two sessions at a 1-week interval, each consisting of an adaptation night (sham stimulation) and an experimental night (rTMS in the left dorsolateral prefrontal cortex or sham stimulation; crossover design), were scheduled. In each subject, 40 trains of 2-s duration of rTMS (inter-train interval 28 s) were applied at a frequency of 20 Hz (i.e. 1600 pulses per session) and at an intensity of 90% of the motor threshold. Stimulations were scheduled 80 min before lights off. The waking EEG was recorded for 10-min intervals approximately 30 min prior to and after the 20-min stimulations, and polysomnographic recordings were obtained during the subsequent sleep episode (23.00-07.00 h). The power spectra of two referential derivations, as well as of bipolar derivations along the antero-posterior axis over the left and right hemispheres, were analyzed. rTMS induced a small reduction of sleep stage 1 (in min and percentage of total sleep time) over the whole night and a small enhancement of sleep stage 4 during the first non-REM sleep episode. Other sleep variables were not affected. rTMS of the left dorsolateral cortex did not alter the topography of EEG power spectra in waking following stimulation, in the all-night sleep EEG, or during the first non-REM sleep episode. Our results indicate that a single session of rTMS using parameters like those used in depression treatment protocols has no detectable side effects with respect to sleep in young healthy males.
Resumo:
This study investigated the effect of high-frequency repetitive transcranial magnetic stimulation (HF-rTMS) of the left prefrontal cortex (LPFC) on mood in a sham-controlled crossover design. Twenty-five healthy male subjects received HF-rTMS of the LPFC in real and sham conditions. Forty trains (frequency 20 Hz, stimulation intensity 100% of individual motor threshold, train duration 2 s, intertrain interval 28 s) were applied in each session. Mood change from baseline was measured with five visual analog scales (VAS) for sadness, anxiety, happiness, tiredness and pain/discomfort. We were unable to demonstrate significant mood changes from baseline on visual analog scales after either sham or real stimulation of LPFC. There is insufficient evidence to support the general conclusion that HF-rTMS of LPFC has mood effects in healthy volunteers. Future studies should be sham-controlled, have larger sample sizes, and strictly stimulate one single region per session in order to exclude interaction effects with the previous stimulation.