121 resultados para Common carotid artery


Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: The arterial pharmacokinetics of ketamine and norketamine enantiomers after racemic ketamine or S-ketamine i.v. administration were evaluated in seven gelding ponies in a crossover study (2-month interval). METHODS: Anaesthesia was induced with isoflurane in oxygen via a face-mask and then maintained at each pony's individual MAC. Racemic ketamine (2.2 mg kg(-1)) or S-ketamine (1.1 mg kg(-1)) was injected in the right jugular vein. Blood samples were collected from the right carotid artery before and at 1, 2, 4, 8, 16, 32, 64, and 128 min after ketamine administration. Ketamine and norketamine enantiomer plasma concentrations were determined by capillary electrophoresis. Individual R-ketamine and S-ketamine concentration vs time curves were analysed by non-linear least square regression two-compartment model analysis using PCNonlin. Plasma disposition curves for R-norketamine and S-norketamine were described by estimating AUC, C(max), and T(max). Pulse rate (PR), respiratory rate (R(f)), tidal volume (V(T)), minute volume ventilation (V(E)), end-tidal partial pressure of carbon dioxide (PE'(CO(2))), and mean arterial blood pressure (MAP) were also evaluated. RESULTS: The pharmacokinetic parameters of S- and R-ketamine administered in the racemic mixture or S-ketamine administered separately did not differ significantly. Statistically significant higher AUC and C(max) were found for S-norketamine compared with R-norketamine in the racemic group. Overall, R(f), V(E), PE'(CO(2)), and MAP were significantly higher in the racemic group, whereas PR was higher in the S-ketamine group. CONCLUSIONS: Norketamine enantiomers showed different pharmacokinetic profiles after single i.v. administration of racemic ketamine in ponies anaesthetised with isoflurane in oxygen (1 MAC). Cardiopulmonary variables require further investigation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: The indications for endovascular aortic aneurysm repair (EVAR) are mainly established in hostile abdomen, in patients with significant comorbidities which affect the general operability of the patient and, given the necessary infrastructure, also in ruptured aneurysm. Along to those, we present another possible indication in the presence of a kidney allograft in patients with aortic aneurysm. METHODS: Based on a case report of aorto-biiliac stent-graft repair of an infrarenal aortic aneurysm in a patient with renal allograft, a systematic review of the literature was performed of all similar cases concerning surgical therapy in this constellation. RESULTS: EVAR was performed using an aorto-biiliac system (Zenith) Trifab, COOK) in a 61-year-old male patient 11 years after heterotopic renal allotransplantation in the right iliac fossa. Preoperative renal function was normal. Because the donor renal artery was anastomosed to the recipient's external iliac artery the stent-graft was implanted from the left common femoral artery to minimize temporary allograft ischemia. The intra- and postoperative course was uneventful with a follow-up of presently 12 months. A primary type-II endoleak (retroleak from a lumbar artery) is being treated conservatively so far with embolization being a future option. At present there are 15 cases of EVAR in renal allograft patients that have been reported, all of them being successful. DISCUSSION: All data existing in the literature reported to date as well as our own experience justify the first choice of EVAR in morphologically suitable cases. One major advantage of EVAR in this constellation is the avoidance of aortic cross clamping which poses the graft at risk of ischemia. Long-term results will be most important for definite assessment of EVAR. However, contrast media application during the operation and for CT surveillance should be considered as a major disadvantage.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: We aimed to assess quality of life (QOL) and its predictors in stroke survivors after local intra-arterial thrombolysis (IAT) as well as to measure QOL according to the site of pretreatment vessel occlusion. Methods: From January 2000 to April 2004, 175 consecutive patients underwent IAT for acute ischemic stroke. Clinical and radiological data were collected prospectively. We contacted 135 stroke survivors after a mean of 923 (+/-431) days, 132 responded. QOL, assessed with EuroQol (EQ-5D), and functional abilities, measured with the modified Rankin Scale (mRS) and the Barthel Index, were compared, and predictors of QOL were analyzed. Results: Measured with EQ-5D, 56% of the patients reported a good QOL (EQ-5D Index >/=70). Low mRS and high Barthel Index scores at follow-up were associated with better overall QOL (Kendall's tau >0.5). Nevertheless, 25% of the functionally independent patients (mRS 0-2) indicated a markedly impaired QOL (EQ-5D Index <70) and 10% of disabled patients indicated good QOL. QOL was significantly lower in patients with occlusion of the internal carotid artery compared to patients with occlusion of the basilar artery or the M1, M2 or M3/4 segment of the middle cerebral artery (EQ-5D Index: p = 0.005). A high National Institute of Health Stroke Scale score on admission and occlusion of the internal carotid artery were independent predictors of impaired QOL (p < 0.05). Conclusion: More than half of the stroke survivors treated with IAT reported a good QOL, mostly survivors with mild disabilities. QOL assessment gives information that is not provided by traditional outcome scores. Our results support guidelines to measure QOL in stroke research. Copyright (c) 2008 S. Karger AG, Basel.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: The use of vascular plug devices for the occlusion of high-flow lesions is a relatively new and successful procedure in peripheral and cardiopulmonary interventions. We report on the use and efficiency of the Amplatzer vascular plug in a small clinical series and discuss its potential for occlusion of large vessels and high-flow lesions in neurointerventions. METHODS: Between 2005 and 2007 four patients (mean age 38.5 years, range 16-62 years) were treated with the device, in three patients to achieve parent artery occlusion of the internal carotid artery, in one patient to occlude a high-flow arteriovenous fistula of the neck. The application, time to occlusion, and angiographic and clinical results and the follow-up were evaluated. RESULTS: Navigation, positioning and detachment of the device were satisfactory in all cases. No flow-related migration of the plug was seen. The cessation of flow was delayed by a mean of 10.5 min after deployment of the first device. In the procedures involving vessel sacrifice, two devices had to be deployed to achieve total occlusion. No patient experienced new neurological deficits; the 3-month follow-up revealed stable results. CONCLUSION: The Amplatzer vascular plug can be adapted for the treatment of high-flow lesions and parent artery occlusions in the head and neck. In this small series the use of the devices was uncomplicated and safe. The rigid and large delivery device and the delayed cessation of flow currently limit the device's use in neurointerventions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: The postoperative assessment of volume status is not straightforward because of concomitant changes in intravascular volume and vascular tone. Hypovolemia and blood flow redistribution may compromise the perfusion of the intraabdominal organs. We investigated the effects of a volume challenge in different intra- and extraabdominal vascular beds. METHODS: Twelve pigs were studied 6 h after major intraabdominal surgery under general anesthesia when clinically normovolemic. Volume challenges consisted of 200 mL rapidly infused 6% hydroxyethyl starch. Systemic (continuous thermodilution) and regional (ultrasound Doppler) flows in carotid, renal, celiac trunk, hepatic, and superior mesenteric arteries and the portal vein were continuously measured. The acute and sustained effects of the challenge were compared with baseline. RESULTS: Volume challenge produced a sustained increase of 22% +/- 15% in cardiac output (P < 0.001). Blood flow increased by 10% +/- 9% in the renal artery, by 22% +/- 15% in the carotid artery, by 26% +/- 15% in the superior mesenteric artery, and by 31% +/- 20% in the portal vein (all P < 0.001). Blood flow increases in the celiac trunk (8% +/- 13%) and the hepatic artery (7% +/- 19%) were not significant. Increases in regional blood flow occurred early and were sustained. Mean arterial and central venous blood pressures increased early and decreased later (all P < 0.05). CONCLUSIONS: A volume challenge in clinically euvolemic postoperative animals was associated with a sustained increase in blood flow to all vascular beds, although the increase in the celiac trunk and the hepatic artery was very modest and did not reach statistical significance. Whether improved postoperative organ perfusion is accompanied by a lower complication rate should be evaluated in further studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: This retrospective study was conducted to determine whether a low-volume contrast medium protocol provides sufficient enhancement for 64-detector computed tomography angiography (CTA) in patients with aortoiliac aneurysms. METHODS: Evaluated were 45 consecutive patients (6 women; mean age, 72 +/- 6 years) who were referred for aortoiliac computed tomography angiography between October 2005 and January 2007. Group A (22 patients; creatinine clearance, 64.2 +/- 8.1 mL/min) received 50 mL of the contrast agent. Group B (23 patients; creatinine clearance, 89.4 +/- 7.3 mL/min) received 100 mL of the contrast agent. The injection rate was 3.5 mL/s, followed by 30 mL of saline at 3.5 mL/s. Studies were performed on the same 64-detector computed tomography scanner using a real-time bolus-tracking technique. Quantitative analysis was performed by determination of mean vascular attenuation at 10 regions of interest from the suprarenal aorta to the common femoral artery by one reader blinded to type and amount of contrast agent and compared using the Student t test. Image quality according to a 4-point scale was assessed in consensus by two readers blinded to type and amount of contrast medium and compared using the Mann-Whitney test. Multivariable adjustments were performed using ordinal regression analysis. RESULTS: Mean total attenuation did not differ significantly between both groups (196.5 +/- 33.0 Hounsfield unit [HU] in group A and 203.1 +/- 44.2 HU in group B; P = .57 by univariate and P > .05 by multivariable analysis). Accordingly, attenuation at each region of interest was not significantly different (P > .35). Image quality was excellent or good in all patients. No significant differences in visual assessment were found comparing both contrast medium protocols (P > .05 by univariate and by multivariable analysis). CONCLUSIONS: Aortoiliac aneurysm imaging can be performed with substantially reduced amounts of contrast medium using 64-detector computed tomography angiography technology.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Delayed ischemic neurological deficit (DIND) following cerebral vasospasm remains a cause for high morbidity and mortality in patients with subarachnoid hemorrhage (SAH). There is experimental and clinical evidence of positive effects of nitric oxide (NO) donors on cerebral vasospasm. We therefore analysed the effect of transdermal nitroglycerin in patients with SAH measuring transcranial Doppler velocities (TCD), cerebral blood flow (CBF) and DIND. Nitroglycerin was used in a target dose of 14 microg/kg/h. TCD assessment was performed daily. CBF measurements were done using the perfusion CT-technique. Blood pressure, volume intake and vasopressor administration, were registered. Nine patients were randomly assigned either to the nitroglycerin group (N-group) and eight patients in the control group (C-group). Mean TCD values in the extracranial portion of the internal carotid artery (ICA) were lower in the N-group (p<0.005). Mean TCD in the middle cerebral arteries (MCA) showed no difference. The Lindegaard ratio was higher in the N-group (p<0.04). CBF in the N-group was higher than in the C-group (p<0.03). Even though nitroglycerin reduces blood pressure and lowers ICA TCD-values and increases the Lindegaard ratio, a higher CBF was measured in the N-group. Thus, nitroglycerin influences the cerebral vascular tone and increases CBF. SAH therapy with nitroglycerin is possible without increasing the risk of DIND. The exact timing of onset, duration and reduction of nitroglycerin administration in respect to the appearance of vasospasm may have a strong impact on the success of such a therapy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was to analyze the suitability of the cerebral vasculature of the pig regarding a revascularization procedure. In two 60 kg pigs the femoral artery was exposed and canulated for selective angiography and interventional procedures. After the angiography, the pigs were brought to the animal OR for craniotomy and analysis of the intracranial cerebral arteries and the surgical exposure of the carotid arteries under the microscope. Angiography demonstrated the presence of a true internal-, external carotid artery and vertebral arteries. Both the vertebral and internal carotid arteries are feeding a rete mirabilis both at the cranial base and the cranio-cervical junction. At these sites further advancement of the angiography catheter was not possible. Out of these rete mirabilis, an intracranial carotid artery and an intracranial vertebral artery were formed, respectively. The intracranial cerebral vessels were of the dimension of 1 mm and less. The extracranial portion of the internal carotid artery was 2.5 mm of diameter. From these findings, we conclude that a direct cerebral revascularization procedure of the intracranial vessels is not possible in the swine. However, a global revascularization procedure on the extracranial portion of the internal carotid artery is thus feasible, both using a low- and high-flow anastamosis technique.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The following is an analysis of the role of computer aided surgery by infralabyrinthine-subcochlear approach to the petrous apex for cholesterol granulomas with hearing preservation. In a retrospective case review from 1996 to 2008 six patients were analysed in our tertiary referral centre, otorhinolaryngology outpatient clinic. Excellent intraoperative localisation of the carotid artery, facial nerve and the entrance into the cholesterol cyst of the bone by means of the navigation system was seen. Additionally, the operation time decreased from an initial 4 h down to 2 h. The application of computer-aided surgery allows intraoperative monitoring of the position of the tip of the microsurgical instruments in case of a rare disease and in the delicate area of the petrous apex giving a high security level.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

At a party of a sports club, an argument started between two groups of young men, in the course of which one of the persons involved threw a beer glass hitting a young man of the other group, who collapsed with a profusely bleeding wound. Although resuscitation measures were initiated immediately, the victim died at the scene due to exsanguination from the completely severed left external carotid artery in combination with the aspiration of blood. Tests with drinking glasses thrown at a skull-neck model suggested that an undamaged beer glass thrown at the head of the victim could not cause the fatal injuries on the neck because of its splintering behaviour. In fact, it seemed that the beer glass had been damaged prior to throwing it and that its sharp edges perforated the skin on hitting the neck.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: Estradiol (E(2)) is known to accelerate reendothelialization and thus prevent intimal thickening and in-stent restenosis after angioplasty. Transplantation experiments with ERalpha(-/-) mice have previously shown that E(2) acts through local and bone marrow cell compartments to enhance endothelial healing. However, the downstream mechanisms induced by E(2) to mediate endothelial repair are still poorly understood. METHODS AND RESULTS: We show here that after endovascular carotid artery injury, E(2)-enhanced endothelial repair is lost in osteopontin-deficient mice (OPN(-/-)). Transplantation of OPN(-/-) bone marrow into wild-type lethally irradiated mice, and vice versa, suggested that osteopontin plays a crucial role in both the local and the bone marrow actions of E(2). In the vascular compartment, using transgenic mice expressing doxycyclin regulatable-osteopontin, we show that endothelial cell specific osteopontin overexpression mimics E(2)-enhanced endothelial cell migration and proliferation in the regenerating endothelium. In the bone marrow cell compartment, we demonstrate that E(2) enhances bone marrow-derived mononuclear cell adhesion to regenerating endothelium in vivo, and that this effect is dependent on osteopontin. CONCLUSIONS: We demonstrate here that E(2) acceleration of the endothelial repair requires osteopontin, both for bone marrow-derived cell recruitment and for endothelial cell migration and proliferation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The effect of whole-body vibration dosage on leg blood flow was investigated. Nine healthy young adult males completed a set of 14 random vibration and non-vibration exercise bouts whilst squatting on a Galileo 900 plate. Six vibration frequencies ranging from 5 to 30 Hz (5 Hz increments) were used in combination with a 2.5 mm and 4.5 mm amplitude to produce twelve 1-min vibration bouts. Subjects also completed two 1-min bouts where no vibration was applied. Systolic and diastolic diameters of the common femoral artery and blood cell velocity were measured by an echo Doppler ultrasound in a standing or rest condition prior to the bouts and during and after each bout. Repeated measures MANOVAs were used in the statistical analysis. Compared with the standing condition, the exercise bouts produced a four-fold increase in mean blood cell velocity (P<0.001) and a two-fold increase in peak blood cell velocity (P<0.001). Compared to the non-vibration bouts, frequencies of 10-30 Hz increased mean blood cell velocity by approximately 33% (P<0.01) whereas 20-30 Hz increased peak blood cell velocity by approximately 27% (P<0.01). Amplitude was additive to frequency but only achieved significance at 30 Hz (P<0.05). Compared with the standing condition, squatting alone produced significant increases in mean and peak blood cell velocity (P<0.001). The results show leg blood flow increased during the squat or non-vibration bouts and systematically increased with frequency in the vibration bouts.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Several patients with chronic critical limb ischemia show angiographically an isolated popliteal segment (IPS) and a single calf vessel (SCV) with no direct communication to the former. In this situation a bypass can be inserted from the common femoral artery to the IPS or to the SCV. The results of 73 bypass procedures--40 to an isolated popliteal segment and 33 to a single calf vessel for limb salvage--were prospectively evaluated. Eighty percent of the grafts were performed with an autogenous saphenous vein (ASV), the rest with a thin wall polytetrafluoroethylene (PTFE) prosthesis. The mean age of our patients was 75 years and many suffered from cardiovascular disease. The operative mortality rate was 3% and the mean postoperative survival 32 months. Three year patency and limb salvage rates for ASV grafts was 83% and 87% (IPS) respectively 77% and 76% (MCV); for PTFE grafts 58% and 88% (IPS) respectively 17% and 50% (MCV). There was no significant difference found in patency and limb salvage rates of the two procedures if the graft was an autogenous saphenous vein (p > 0.05). The PTFE prosthesis was only suitable for grafts inserted to the isolated popliteal segment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study investigated vascular reactivity in response to acetylcholine, in the presence of acute inhibition of nitric oxide synthase, in the carotid artery and aorta of obese C57Bl6/J mice fed on a high-fat diet for 30 weeks, and of control mice. A subgroup of obese animals was also treated with the ET(A) receptor antagonist darusentan (50 mg x kg(-1) x day(-1)). In vascular rings from control animals, acetylcholine caused endothelium-dependent contractions in the carotid artery, but not in the aorta. In vascular rings from obese mice, contractility to acetylcholine was also evident in the aorta, and that in the carotid artery was increased compared with control mice. ET(A) receptor blockade by darusentan treatment of the obese mice prevented enhanced vasoconstriction to acetylcholine, resulting in mild vasodilatation. Thus obesity increases endothelium-dependent vasoconstriction in the absence of endothelial nitric oxide. This effect can be completely prevented by chronic ET(A) receptor blockade, suggesting that endothelin modulates increased endothelium-dependent vasoconstriction in obesity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report on oxygenation changes noninvasively recorded by multichannel continuous-wave near infrared spectroscopy (CW-NIRS) during endovascular neuroradiologic interventions requiring temporary balloon occlusion of arteries supplying the cerebral circulation. Digital subtraction angiography (DSA) provides reference data on the site, timing, and effectiveness of the flow stagnation as well as on the amount and direction of collateral circulation. This setting allows us to relate CW-NIRS findings to brain specific perfusion changes. We focused our analysis on the transition from normal perfusion to vessel occlusion, i.e., before hypoxia becomes clinically apparent. The localization of the maximal response correlated either with the core (occlusion of the middle cerebral artery) or with the watershed areas (occlusion of the internal carotid artery) of the respective vascular territories. In one patient with clinically and angiographically confirmed insufficient collateral flow during carotid artery occlusion, the total hemoglobin concentration became significantly asymmetric, with decreased values in the ipsilateral watershed area and contralaterally increased values. Multichannel CW-NIRS monitoring might serve as an objective and early predictive marker of critical perfusion changes during interventions-to prevent hypoxic damage of the brain. It also might provide valuable human reference data on oxygenation changes as they typically occur during acute stroke.