105 resultados para Clinical performance


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The objective of this systematic review was to assess the 5-year survival rates and incidences of complications associated with ceramic abutments and to compare them with those of metal abutments. METHODS: An electronic Medline search complemented by manual searching was conducted to identify randomized-controlled clinical trials, and prospective and retrospective studies providing information on ceramic and metal abutments with a mean follow-up time of at least 3 years. Patients had to have been examined clinically at the follow-up visit. Assessment of the identified studies and data abstraction was performed independently by three reviewers. Failure rates were analyzed using standard and random-effects Poisson regression models to obtain summary estimates of 5-year survival proportions. RESULTS: Twenty-nine clinical and 22 laboratory studies were selected from an initial yield of 7136 titles and data were extracted. The estimated 5-year survival rate of ceramic abutments was 99.1% [95% confidence interval (CI): 93.8-99.9%] and 97.4% (95% CI: 96-98.3%) for metal abutments. The estimated cumulative incidence of technical complications after 5 years was 6.9% (95% CI: 3.5-13.4%) for ceramic abutments and 15.9% (95% CI: 11.6-21.5%) for metal abutments. Abutment screw loosening was the most frequent technical problem, occurring at an estimated cumulative incidence after 5 years of 5.1% (95% CI: 3.3-7.7%). All-ceramic crowns supported by ceramic abutments exhibited similar annual fracture rates as metal-ceramic crowns supported by metal abutments. The cumulative incidence of biological complications after 5 years was estimated at 5.2% (95% CI: 0.4-52%) for ceramic and 7.7% (95% CI: 4.7-12.5%) for metal abutments. Esthetic complications tended to be more frequent at metal abutments. A meta-analysis of the laboratory data was impossible due to the non-standardized test methods of the studies included. CONCLUSION: The 5-year survival rates estimated from annual failure rates appeared to be similar for ceramic and metal abutments. The information included in this review did not provide evidence for differences of the technical and biological outcomes of ceramic and metal abutments. However, the information for ceramic abutments was limited in the number of studies and abutments analyzed as well as the accrued follow-up time. Standardized methods for the analysis of abutment strength are needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to determine the influence of polyvinyl chloride (PVC) wrapping on the performance of two laser fluorescence devices (LF and LFpen) by assessing tooth occlusal surfaces. BACKGROUND DATA: Protection of their tips may influence LF measurements. To date there are no studies evaluating the influence of this protection on the performance of the LFpen on permanent teeth, or comparing it to the original LF device. MATERIALS AND METHODS: One hundred nineteen permanent molars were assessed by two experienced dentists using the LF and the LFpen devices, both with and without PVC wrapping. The teeth were histologically prepared and assessed for caries extension. RESULTS: The LF values with and without PVC wrapping were significantly different. For both LF devices, the sensitivity and accuracy were lower when the PVC wrapping was used. The specificity was statistically significantly higher for the LFpen with PVC. No difference was found between the areas under the ROC curves with and without PVC wrapping. The ICC showed excellent interexaminer agreement. The Bland and Altman method showed a range between the upper and the lower limits of agreement of 63.4 and 57.8 units for the LF device, and 49.4 and 74.2 for the LFpen device, with and without PVC wrapping, respectively. CONCLUSIONS: We found an influence of the PVC wrapping on the performance of the LF and LFpen devices. However, since its influence on detection of occlusal caries lesions is considered for, the use of one PVC layer is suggested to avoid cross-contamination in clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES This study examined the near visual acuity of dentists in relation to age and magnification under simulated clinical conditions. MATERIALS AND METHODS Miniaturized visual tests were performed in posterior teeth of a dental phantom head in a simulated clinical setting (dental chair, operating lamp, dental mirror). The visual acuity of 40 dentists was measured under the following conditions: (1) natural visual acuity, distance of 300 mm; (2) natural visual acuity, free choice of distance; (3) Galilean loupes, magnification of ×2.5; (4) Keplerian loupes, ×4.3; (5) operating microscope, ×4, integrated light; (6) operating microscope, ×6.4, integrated light. RESULTS The visual acuity varied widely between individuals and was significantly lower in the group ≥40 years of age (p < 0.001). Significant differences were found between all tested conditions (p < 0.01). Furthermore, a correlation between visual acuity and age was found for all conditions. The performance with the microscope was better than with loupes even with comparable magnification factors. Some dentists had a better visual acuity without optical aids than others with Galilean loupes. CONCLUSIONS Near visual acuity under simulated clinical conditions varies widely between individuals and decreases throughout life. Visual deficiencies can be compensated for with optical aids. CLINICAL RELEVANCE Newly developed miniaturized vision tests have allowed, in a clinically relevant way, to evaluate the influence of magnification and age on the near visual acuity of dentists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gene therapy, aimed at the correction of key pathologies being out of reach for conventional drugs, bears the potential to alter the treatment of cardiovascular diseases radically and thereby of heart failure. Heart failure gene therapy refers to a therapeutic system of targeted drug delivery to the heart that uses formulations of DNA and RNA, whose products determine the therapeutic classification through their biological actions. Among resident cardiac cells, cardiomyocytes have been the therapeutic target of numerous attempts to regenerate systolic and diastolic performance, to reverse remodeling and restore electric stability and metabolism. Although the concept to intervene directly within the genetic and molecular foundation of cardiac cells is simple and elegant, the path to clinical reality has been arduous because of the challenge on delivery technologies and vectors, expression regulation, and complex mechanisms of action of therapeutic gene products. Nonetheless, since the first demonstration of in vivo gene transfer into myocardium, there have been a series of advancements that have driven the evolution of heart failure gene therapy from an experimental tool to the threshold of becoming a viable clinical option. The objective of this review is to discuss the current state of the art in the field and point out inevitable innovations on which the future evolution of heart failure gene therapy into an effective and safe clinical treatment relies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to describe the process to obtain Food and Drug Administration (FDA) approval for the expanded indication for treatment with the Resolute zotarolimus-eluting stent (R-ZES) (Medtronic, Inc., Santa Rosa, California) in patients with coronary artery disease and diabetes. BACKGROUND The R-ZES is the first drug-eluting stent specifically indicated in the United States for percutaneous coronary intervention in patients with diabetes. METHODS We pooled patient-level data for 5,130 patients from the RESOLUTE Global Clinical Program. A performance goal prospectively determined in conjunction with the FDA was established as a rate of target vessel failure at 12 months of 14.5%. In addition to the FDA pre-specified cohort of less complex patients with diabetes (n = 878), we evaluated outcomes of the R-ZES in all 1,535 patients with diabetes compared with all 3,595 patients without diabetes at 2 years. RESULTS The 12-month rate of target vessel failure in the pre-specified diabetic cohort was 7.8% (upper 95% confidence interval: 9.51%), significantly lower than the performance goal of 14.5% (p < 0.001). After 2 years, the cumulative incidence of target lesion failure in patients with noninsulin-treated diabetes was comparable to that of patients without diabetes (8.0% vs. 7.1%). The higher risk insulin-treated population demonstrated a significantly higher target lesion failure rate (13.7%). In the whole population, including complex patients, rates of stent thrombosis were not significantly different between patients with and without diabetes (1.2% vs. 0.8%). CONCLUSIONS The R-ZES is safe and effective in patients with diabetes. Long-term clinical data of patients with noninsulin-treated diabetes are equivalent to patients without diabetes. Patients with insulin-treated diabetes remain a higher risk subset. (The Medtronic RESOLUTE Clinical Trial; NCT00248079; Randomized, Two-arm, Non-inferiority Study Comparing Endeavor-Resolute Stent With Abbot Xience-V Stent [RESOLUTE-AC]; NCT00617084; The Medtronic RESOLUTE US Clinical Trial (R-US); NCT00726453; RESOLUTE International Registry: Evaluation of the Resolute Zotarolimus-Eluting Stent System in a 'Real-World' Patient Population [R-Int]; NCT00752128; RESOLUTE Japan-The Clinical Evaluation of the MDT-4107 Drug-Eluting Coronary Stent [RJ]; NCT00927940).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND CONTEXT A new device, DensiProbe, has been developed to provide surgeons with intraoperative information about bone strength by measuring the peak breakaway torque. In cases of low bone quality, the treatment can be adapted to the patient's condition, for example, by improving screw-anchorage with augmentation techniques. PURPOSE The objective of this study was to investigate the feasibility of DensiProbe Spine in patients undergoing transpedicular fixation. STUDY DESIGN Prospective feasibility study on consecutive patients. PATIENT SAMPLE Fourteen women and 16 men were included in this study. OUTCOME MEASURES Local and general bone quality. METHODS These consecutive patients scheduled for transpedicular fixation were evaluated for bone mineral density (BMD), which was measured globally by dual-energy X-ray absorptiometry and locally via biopsies using quantitative microcomputed tomography. The breakaway torque force within the vertebral body was assessed intraoperatively via the transpedicular approach with the DensiProbe Spine. The results were correlated with the areal BMD at the lumbar spine and the local volumetric BMD (vBMD) and a subjective impression of bone strength. The feasibility of the method was evaluated, and the clinical and radiological performance was evaluated over a 1-year follow-up. This study was funded by an AO Spine research grant; DensiProbe was developed at the AO Research Institute Davos, Switzerland; the AO Foundation is owner of the intellectual property rights. RESULTS In 30 patients, 69 vertebral levels were examined. The breakaway torque consistently correlated with an experienced surgeon's quantified impression of resistance as well as with vBMD of the same vertebra. Beyond a marginal prolongation of surgery time, no adverse events related to the usage of the device were observed. CONCLUSIONS The intraoperative transpedicular measurement of the peak breakaway torque was technically feasible, safe, and reliably predictive of local vBMD during dorsal spinal instrumentations in a clinical setting. Larger studies are needed to define specific thresholds that indicate a need for the augmentation or instrumentation of additional levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Replacement intervals of implantable medical devices are commonly dictated by battery life. Therefore, intracorporeal energy harvesting has the potential to reduce the number of surgical interventions by extending the life cycle of active devices. Given the accumulated experience with intravascular devices such as stents, heart valves, and cardiac assist devices, the idea to harvest a small fraction of the hydraulic energy available in the cardiovascular circulation is revisited. The aim of this article is to explore the technical feasibility of harvesting 1 mW electric power using a miniature hydrodynamic turbine powered by about 1% of the cardiac output flow in a peripheral artery. To this end, numerical modelling of the fluid mechanics and experimental verification of the overall performance of a 1:1 scale friction turbine are performed in vitro. The numerical flow model is validated for a range of turbine configurations and flow conditions (up to 250 mL/min) in terms of hydromechanic efficiency; up to 15% could be achieved with the nonoptimized configurations of the study. Although this article does not entail the clinical feasibility of intravascular turbines in terms of hemocompatibility and impact on the circulatory system, the numerical model does provide first estimates of the mechanical shear forces relevant to blood trauma and platelet activation. It is concluded that the time-integrated shear stress exposure is significantly lower than in cardiac assist devices due to lower flow velocities and predominantly laminar flow.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Musicians often suffer injuries related to their music playing. Therefore, some use Alexander Technique (AT), a mental-physical method that facilitates to release unnecessary muscle tension and to re-educate non-beneficial movement patterns through enhanced kinaesthetic awareness. According to a recent review AT may be effective for chronic back pain [1]. This review aimed to evaluate the evidence for the effectiveness of AT lessons on music performance and musicians’ health and well-being. Methods The following electronic databases were searched up to July 2012 for relevant literature: PUBMED, Google Scholar, CINAHL and EMBASE. The search criteria were "Alexander technique" AND "music*" [all fields]. References were searched, and experts and societies of AT or musicians' medicine contacted for further publications. Results 100 studies were identified. 24 studies were included for further analysis, 5 of which were randomised controlled trials (RCTs), 5 controlled but not randomised (CTs), 5 without control group, 2 mixed methods (RCT and case studies), and 7 surveys. 13 to 72 musicians participated per RCT. In 5 RCTs AT groups received between 12 and 20 one-to-one lessons. In 4 RCTs control groups received no interventions. Primary outcomes were performance anxiety, music performance, "use" as well as respiratory function and pain. Performance anxiety decreased by AT in 3 of 4 RCTs and in 3 of 3 CTs. Music performance was improved by AT in 1 RCT, yet in 2 RCTs comparing neurofeedback (NF) to AT, only NF showed improvements. Discussion and Conclusion To investigate the effectiveness of AT in musicians a variety of study designs and outcome measures have been used. Evidence from RCTs suggests that AT may improve performance anxiety in musicians. Effects on music performance, body use and respiratory function yet remain inconsistent. Future trials with scientifically sound study designs are warranted to further and more reliably explore the potential of AT as a relatively low cost and low risk method in the interest of musicians. References [1] Woodman JP, Moore NR. Evidence for the effectiveness of Alexander Technique lessons in medical and health-related conditions: a systematic review. Int J Clin Pract 2012;66(1):98-112.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE We report on workflow and process-based performance measures and their effect on clinical outcome in Solitaire FR Thrombectomy for Acute Revascularization (STAR), a multicenter, prospective, single-arm study of Solitaire FR thrombectomy in large vessel anterior circulation stroke patients. METHODS Two hundred two patients were enrolled across 14 centers in Europe, Canada, and Australia. The following time intervals were measured: stroke onset to hospital arrival, hospital arrival to baseline imaging, baseline imaging to groin puncture, groin puncture to first stent deployment, and first stent deployment to reperfusion. Effects of time of day, general anesthesia use, and multimodal imaging on workflow were evaluated. Patient characteristics and workflow processes associated with prolonged interval times and good clinical outcome (90-day modified Rankin score, 0-2) were analyzed. RESULTS Median times were onset of stroke to hospital arrival, 123 minutes (interquartile range, 163 minutes); hospital arrival to thrombolysis in cerebral infarction (TICI) 2b/3 or final digital subtraction angiography, 133 minutes (interquartile range, 99 minutes); and baseline imaging to groin puncture, 86 minutes (interquartile range, 24 minutes). Time from baseline imaging to puncture was prolonged in patients receiving intravenous tissue-type plasminogen activator (32-minute mean delay) and when magnetic resonance-based imaging at baseline was used (18-minute mean delay). Extracranial carotid disease delayed puncture to first stent deployment time on average by 25 minutes. For each 1-hour increase in stroke onset to final digital subtraction angiography (or TICI 2b/3) time, odds of good clinical outcome decreased by 38%. CONCLUSIONS Interval times in the STAR study reflect current intra-arterial therapy for patients with acute ischemic stroke. Improving workflow metrics can further improve clinical outcome. CLINICAL TRIAL REGISTRATION: URL http://www.clinicaltrials.gov. Unique identifier: NCT01327989.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: To examine the effect of memory strategy training on different aspects of memory in children born very preterm and to determine whether there is a generalization of the training effect to non-trained functions. The influence of individual factors such as age and performance level on the training success will be determined. Methods: In a randomized, controlled and blinded clinical trial, 46 children born very preterm (aged 7-12 years) were allocated to a memory strategy training (MEMO-Training, n=23) or a control group (n=23). Neuropsychological assessment was performed before, immediately after the training and at a 6-month follow-up. In the MEMO-Training, five different memory strategies were introduced and practiced in a one-to-one setting (4 hour-long training sessions over 4 weeks, 20 homework sessions). Results: A significant training-related improvement occurred in trained aspects of memory (verbal and visual learning and recall, verbal working memory) and in non-trained functions (inhibition, mental arithmetic). No performance increase was observed in the control group. At six months follow-up, there was a significant training-related improvement of visual working memory. Age and performance level before the training predicted the training success significantly. Conclusion: Teaching memory strategies is an effective way to improve different aspects of memory but also non-trained functions such as inhibition and mental arithmetic in children born very preterm. Age and performance level influence the success of memory strategy training. These results highlight the importance of teaching children memory strategies to reduce scholastic problems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction According to Lent and Lopez’ (2002) tripartite view of efficacy beliefs, members of a team form beliefs about the efficacy of their team partners. This other-efficacy belief can influence individual performance as shown by Dunlop, Beatty, and Beauchamp (2011) in their experimental study using manipulated performance feedback to alter other-efficacy beliefs. Participants holding favorable other-efficacy beliefs outperformed those with lower other--‐efficacy beliefs. Antecedents of such other-efficacy beliefs are amongst others perceptions regarding motivation and psychological factors of the partner (Jackson, Knapp, & Beauchamp, 2008). Overt self-talk could be interpreted as the manifestation of such motivational or psychological factors. In line with this assumption, in an experimental study using dubbed videos of the same segment of a tennis match, Van Raalte, Brewer, Cornelius, and Petitpas (2006) found that players were perceived more favorably (e.g., more concentrated, and of higher ability levels) when shown with dubbed positive self-talk as compared to dubbed negative or no dubbed self--‐talk. Objectives The aim of the study was to examine the possible effects of a confederate’s overt self-talk on participants’ other-efficacy beliefs and performance in a team setting. Method In a laboratory experiment (between-subjects, pre-post-test design, matched by pretest performance) 89 undergraduate students (female = 35, M = 20.81 years, SD = 2.34) participated in a golf putting task together with a confederate (same gender groups). Depending on the experimental condition (positive, negative, or no self-talk), the confederate commented his or her putts according to a self-talk script. Bogus performance feedback assured that the performance of the confederate was held constant. Performance was measured as the distance to the center of the target, other-efficacy by a questionnaire. Results The data collection has just finished and the results of repeated measures analyses of variance will be presented and discussed at the congress. We expect to find higher other-efficacy beliefs and better individual performance in the positive self-talk condition. References Dunlop, W.L., Beatty, D.J., & Beauchamp, M.R. (2011). Examining the influence of other-efficacy and self-efficacy on personal performance. Journal of Sport & Exercise Psychology, 33, 586-593. Jackson, B., Knapp, P., & Beauchamp, M.R. (2008). Origins and consequences of tripartite efficacy beliefs within elite athlete dyads. Journal of Sport and Exercise Psychology, 30, 512-540. Lent, R.W., & Lopez, F.G. (2002). Cognitive ties that bind: A tripartite view of efficacy beliefs in growth--‐promoting relationships. Journal of Social and Clinical Psychology, 21, 256-286. Van Raalte, J.L., Brewer, B.W, Cornelius, A.E., & Petitpas, A.J. (2006). Self-presentational effects of self-talk on perceptions of tennis players. Hellenic Journal of Psychology, 3, 134-149.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES This study aimed to update the Logistic Clinical SYNTAX score to predict 3-year survival after percutaneous coronary intervention (PCI) and compare the performance with the SYNTAX score alone. BACKGROUND The SYNTAX score is a well-established angiographic tool to predict long-term outcomes after PCI. The Logistic Clinical SYNTAX score, developed by combining clinical variables with the anatomic SYNTAX score, has been shown to perform better than the SYNTAX score alone in predicting 1-year outcomes after PCI. However, the ability of this score to predict long-term survival is unknown. METHODS Patient-level data (N = 6,304, 399 deaths within 3 years) from 7 contemporary PCI trials were analyzed. We revised the overall risk and the predictor effects in the core model (SYNTAX score, age, creatinine clearance, and left ventricular ejection fraction) using Cox regression analysis to predict mortality at 3 years. We also updated the extended model by combining the core model with additional independent predictors of 3-year mortality (i.e., diabetes mellitus, peripheral vascular disease, and body mass index). RESULTS The revised Logistic Clinical SYNTAX models showed better discriminative ability than the anatomic SYNTAX score for the prediction of 3-year mortality after PCI (c-index: SYNTAX score, 0.61; core model, 0.71; and extended model, 0.73 in a cross-validation procedure). The extended model in particular performed better in differentiating low- and intermediate-risk groups. CONCLUSIONS Risk scores combining clinical characteristics with the anatomic SYNTAX score substantially better predict 3-year mortality than the SYNTAX score alone and should be used for long-term risk stratification of patients undergoing PCI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Drug eluting stents for the treatment of small vessel coronary artery disease have traditionally yielded inferior clinical outcomes compared to the use of DES in large vessels. The benefit of the second-generation Resolute zotarolimus-eluting stent (R-ZES) in small vessels was examined. METHODS Two-year clinical outcomes from five combined R-ZES studies were compared between patients with small (reference vessel diameter [RVD] ≤2.5 mm; n = 1,956) and large (RVD >2.5 mm; n = 3174) vessels. RESULTS Despite a higher incidence of comorbidities in the small vessel group, there was no significant difference in target lesion failure (TLF) (10.1% vs. 8.7%; P = 0.54) at 2 years. When the subgroup of patients with diabetes was examined (n = 1,553) there was no significant difference in 2-year TLF in small compared to large vessels (11.2% vs. 11.1%; P = 0.17). Similarly, within the small vessel cohort, no significant difference was seen regarding TLF at 2 years between people with and without diabetes (11.2% vs 9.6%; P = 0.28). CONCLUSION When used for the treatment of small vessels, the R-ZES appears to provide acceptable clinical results at 2 years when compared to its performance in large vessels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES This study examined the impact of age and magnification on the near visual acuity of dentists in their private practice under simulated clinical conditions. MATERIALS AND METHODS Miniaturized visual tests were fixed in posterior teeth of a dental phantom head and brought to 31 dentists in their respective private practice. The visual acuity of these dentists (n = 19, ≥40 years; n = 12, <40 years) was measured in a clinical setting under the following conditions: (a) natural visual acuity, distance of 300 mm; (b) natural visual acuity, free choice of the distance; and (c) loupe and additional light source, if available. RESULTS The visual acuity under the different clinical conditions varied widely between individuals. The older group of dentists had a lower median visual acuity value under all clinical conditions. This difference was highly significant for natural visual acuity at a free choice of distance (p < 0.0001). For younger dentists (<40 years), visual acuity could be significantly improved by reducing the eye-object distance (p = 0.001) or by using loupes (p = 0.008). For older dentists (≥40 years), visual acuity could be significantly improved by using loupes (p = 0.0005). CONCLUSIONS Visual performance decreased with increasing age under the specific clinical conditions of each dentist's private practice. Magnification aids can compensate for visual deficiencies. CLINICAL RELEVANCE The question of whether findings obtained under standardized conditions are valuable for the habitual setting of each dentist's private practice seems clinically relevant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The Sorin Freedom SOLO (FS) bovine pericardial stentless valve prosthesis is designed for supraannular, subcoronary implantation. We report our experience and results with 277 consecutively implanted FS bioprostheses. METHODS 277 patients (mean age, 74.2 ± 7.3 years; 139 (50.2%) female) underwent aortic valve replacement (AVR) with the FS stentless bioprosthesis. The hemodynamic performance was investigated with transthoracic echocardiography at discharge, 6 months later, and yearly thereafter. Follow-up was 100% complete, with an average observation time of 2.6 ± 1.7 years and a total of 697.3 patient-years. RESULTS The overall 30-day mortality was 4.3%. The mortalities for isolated AVR and combined procedures were 1.9% and 7.3%, respectively. No causes of death were valve-related. Preoperative peak (74.2 ± 23.0 mm Hg) and mean (48.6 ± 16.3 mm Hg) gradients decreased to 15.6 ± 5.4 mm Hg and 8.8 ± 3.0 mm Hg postoperatively and remained unchanged for as long as 5 years. The postoperative mean effective orifice area (EOA) for valve sizes 19, 21, 23, 25, and 27 were 1.49 ± 0.32 cm(2), 1.67 ± 0.40 cm(2), 1.92 ± 0.38 cm(2), 2.01 ± 0.42 cm(2), and 2.13 ± 0.36 cm(2), respectively. Severe prosthesis-patient mismach (PPM) was completely absent, and moderate PPM occurred in 17 patients (6.1%). In isolated AVR, 0.8% of patients with preoperative sinus rhythm required a permanent pacemaker before hospital discharge. There was 100% freedom from structural valve deterioration, 99.6 % freedom from endocarditis and reoperation, and 97.3% freedom from thromboembolism at 5 years. CONCLUSIONS The FS stentless aortic valve is safe to implant, and it shows excellent hemodynamic performance and early and midterm results. Owing to the favorable EOA, the valve appears particularly attractive for patients at risk for PPM.