160 resultados para CROWN-ETHER CORE
Resumo:
A chronology called EDML1 has been developed for the EPICA ice core from Dronning Maud Land (EDML). EDML1 is closely interlinked with EDC3, the new chronology for the EPICA ice core from Dome-C (EDC) through a stratigraphic match between EDML and EDC that consists of 322 volcanic match points over the last 128 ka. The EDC3 chronology comprises a glaciological model at EDC, which is constrained and later selectively tuned using primary dating information from EDC as well as from EDML, the latter being transferred using the tight stratigraphic link between the two cores. Finally, EDML1 was built by exporting EDC3 to EDML. For ages younger than 41 ka BP the new synchronized time scale EDML1/EDC3 is based on dated volcanic events and on a match to the Greenlandic ice core chronology GICC05 via 10Be and methane. The internal consistency between EDML1 and EDC3 is estimated to be typically ~6 years and always less than 450 years over the last 128 ka (always less than 130 years over the last 60 ka), which reflects an unprecedented synchrony of time scales. EDML1 ends at 150 ka BP (2417 m depth) because the match between EDML and EDC becomes ambiguous further down. This hints at a complex ice flow history for the deepest 350 m of the EDML ice core.
Resumo:
BACKGROUND: Mild perioperative hypothermia increases the risk of several severe complications. Perioperative patient warming to preserve normothermia has thus become routine, with forced-air warming being used most often. In previous studies, various resistive warming systems have shown mixed results in comparison with forced-air. Recently, a polymer-based resistive patient warming system has been developed. We compared the efficacy of a standard forced-air warming system with the resistive polymer system in volunteers. METHODS: Eight healthy volunteers participated, each on two separate study days. Unanesthetized volunteers were cooled to a core temperature (tympanic membrane) of 34 degrees C by application of forced-air at 10 degrees C and a circulating-water mattress at 4 degrees C. Meperidine and buspirone were administered to prevent shivering. In a randomly designated order, volunteers were then rewarmed (until their core temperatures reached 36 degrees C) with one of the following active warming systems: (1) forced-air warming (Bair Hugger warming cover #300, blower #750, Arizant, Eden Prairie, MN); or (2) polymer fiber resistive warming (HotDog whole body blanket, HotDog standard controller, Augustine Biomedical, Eden Prairie, MN). The alternate system was used on the second study day. Metabolic heat production, cutaneous heat loss, and core temperature were measured. RESULTS: Metabolic heat production and cutaneous heat loss were similar with each system. After a 30-min delay, core temperature increased nearly linearly by 0.98 (95% confidence interval 0.91-1.04) degrees C/h with forced-air and by 0.92 (0.85-1.00) degrees C/h with resistive heating (P = 0.4). CONCLUSIONS: Heating efficacy and core rewarming rates were similar with full-body forced-air and full-body resistive polymer heating in healthy volunteers.
Resumo:
Diagnostic and therapeutic interventions following dental injuries are not part of the routine practice in the dental office. Quite often, these patients are emergency cases who seek treatment after normal office hours. The objective of this and the future papers is to present the current treatment concepts in dental traumatology at the School of Dental Medicine, University of Berne. The fruitful cooperation in the field of dental traumatology between the Department of Oral Surgery and Stomatology, and the Department of Conservative Dentistry (including pediatric dentistry and endodontology) is based on the interdisciplinary approach that has been established five years ago. Following discussion and evaluation of such treated cases, and considering current clinical and experimental references, the said concepts have been worked out. The present paper describes the therapeutic concepts of crown fractures.
Resumo:
BACKGROUND: With the International Classification of Functioning, Disability and Health (ICF), we can now rely on a globally agreed-upon framework and system for classifying the typical spectrum of problems in the functioning of persons given the environmental context in which they live. ICF Core Sets are subgroups of ICF items selected to capture those aspects of functioning that are most likely to be affected by sleep disorders. OBJECTIVE: The objective of this paper is to outline the developmental process for the ICF Core Sets for Sleep. METHODS: The ICF Core Sets for Sleep will be defined at an ICF Core Sets Consensus Conference, which will integrate evidence from preliminary studies, namely (a) a systematic literature review regarding the outcomes used in clinical trials and observational studies, (b) focus groups with people in different regions of the world who have sleep disorders, (c) an expert survey with the involvement of international clinical experts, and (d) a cross-sectional study of people with sleep disorders in different regions of the world. CONCLUSION: The ICF Core Sets for Sleep are being designed with the goal of providing useful standards for research, clinical practice and teaching. It is hypothesized that the ICF Core Sets for Sleep will stimulate research that leads to an improved understanding of functioning, disability, and health in sleep medicine. It is of further hope that such research will lead to interventions and accommodations that improve the restoration and maintenance of functioning and minimize disability among people with sleep disorders throughout the world.
Resumo:
The purpose of this study was to investigate the accuracy of diagnosing interproximal subgingival caries at crown margins. A total of 32 subgingival interproximal crown margin areas were examined by 10 clinicians (n = 320) using conventional diagnostic methods on extracted, crowned teeth mounted in a specially designed cast. Crown margins were located 1.5 mm below the level of the artificial gingiva. Clinical and radiographic diagnoses were compared to the histopathologic findings for each site. Both visual-tactile and radiographic evaluations revealed a weak diagnostic accuracy for interproximal subgingival crown margin caries.
Resumo:
OBJECTIVE: The aim of this study was to establish and validate a three-dimensional imaging protocol for the assessment of Computed Tomography (CT) scans of abdominal aortic aneurysms in UK EVAR trials patients. Quality control and repeatability of anatomical measurements is important for the validity of any core laboratory. METHODS: Three different observers performed anatomical measurements on 50 preoperative CT scans of aortic aneurysms using the Vitrea 2 three-dimensional post-imaging software in a core laboratory setting. We assessed the accuracy of intra and inter observer repeatability of measurements, the time required for collection of measurements, 3 different levels of automation and 3 different automated criteria for measurement of neck length. RESULTS: None of the automated neck length measurements demonstrated sufficient accuracy and it was necessary to perform checking of the important automated landmarks. Good intra and limited inter observer agreement were achieved with three-dimensional assessment. Complete assessment of the aneurysm and iliacs took an average (SD) of 17.2 (4.1) minutes. CONCLUSIONS: Aortic aneurysm anatomy can be assessed reliably and quickly using three-dimensional assessment but for scans of limited quality, manual checking of important landmarks remains necessary. Using a set protocol, agreement between observers is satisfactory but not as good as within observers.
Resumo:
Pathologically elevated body core temperature, measured at the death scene, is an important finding in medico-legal investigation of violent deaths. An abnormally high rectal temperature at any death scene may point to an underlying pathology, the influence of certain drugs or a hidden cerebral traumatism, and death by suffocation which would remain undetected without further medico-legal investigations. Furthermore, hyperthermia and fever, if unrecognized, may result in an erroneous forensic estimation of time since death in the early postmortem period by the "Henssge method." By a retrospective study of 744 cases, the authors demonstrate that hyperthermia is a finding with an incidence of 10% of all cases of violent death. The main causes are: influence of drugs, malignant tumors, cerebral hypoxia as a result of suffocation, infections, and systemic inflammatory disorders. As a consequence it must be stated, that hyperthermia must be excluded in every medico-legal death scene investigation by a correct measurement of body core temperature and a comparison between the cooling rate of the body and the behavior of early postmortem changes, notably livor and rigor mortis.