100 resultados para BMI cut-off
Resumo:
OBJECTIVE The primary aim of the study was to evaluate whether rheumatoid arthritis (RA) patients considered to be in remission according to clinical criteria sets still had persisting ultrasound (US) synovitis. We further intended to evaluate the capacity of our US score to discriminate between the patients with a clinically active disease versus those in remission. METHODS This is an observational study nested within the Swiss Clinical Quality Management in Rheumatic Diseases (SCQM) rheumatoid arthritis cohort. A validated US score (SONAR score) based on a semi-quantitative B-mode and Doppler (PwD) score as part of the regular clinical workup by rheumatologists in different clinical settings was used. To define clinically relevant synovitis, the same score was applied to 38 healthy controls and the 90st percentile was used as cut-off for 'relevant' synovitis. RESULTS Three hundred and seven patients had at least one US examination and concomitant clinical information on disease activity. More than a third of patients in both DAS28 and ACR/EULAR remission showed significant gray scale synovitis (P=0.01 and 0.0002, respectively) and PwD activity (P=0.005 and 0.0005, respectively) when compared to controls. The capacity of US to discriminate between the two clinical remission groups and patients with active disease was only moderate. CONCLUSION This observational study confirms that many patients considered to be in clinical remission according the DAS and the ACR/EULAR definitions still have residual synovitis on US. The prognostic significance of US synovitis and the exact place of US in patients reaching clinical remission need to be further evaluated.
Resumo:
Immunoglobulin A (IgA) serves as the basis of the secretory immune system by protecting the lining of mucosal sites from pathogens. In both humans and dogs, IgA deficiency (IgAD) is associated with recurrent infections of mucosal sites and immune-mediated diseases. Low concentrations of serum IgA have previously been reported to occur in a number of dog breeds but no generally accepted cut-off value has been established for canine IgAD. The current study represents the largest screening to date of IgA in dogs in terms of both number of dogs (n = 1267) and number of breeds studied (n = 22). Serum IgA concentrations were quantified by using capture ELISA and were found to vary widely between breeds. We also found IgA to be positively correlated with age (p < 0.0001). Apart from the two breeds previously reported as predisposed to low IgA (Shar-Pei and German shepherd), we identified six additional breeds in which ≥10% of all tested dogs had very low (<0.07 g/l) IgA concentrations (Hovawart, Norwegian elkhound, Nova Scotia duck tolling retriever, Bullterrier, Golden retriever and Labrador retriever). In addition, we discovered low IgA concentrations to be significantly associated with canine atopic dermatitis (CAD, p < 0.0001) and pancreatic acinar atrophy (PAA, p = 0.04) in German shepherds.
Resumo:
BackgroundConsensus-based approaches provide an alternative to evidence-based decision making, especially in situations where high-level evidence is limited. Our aim was to demonstrate a novel source of information, objective consensus based on recommendations in decision tree format from multiple sources.MethodsBased on nine sample recommendations in decision tree format a representative analysis was performed. The most common (mode) recommendations for each eventuality (each permutation of parameters) were determined. The same procedure was applied to real clinical recommendations for primary radiotherapy for prostate cancer. Data was collected from 16 radiation oncology centres, converted into decision tree format and analyzed in order to determine the objective consensus.ResultsBased on information from multiple sources in decision tree format, treatment recommendations can be assessed for every parameter combination. An objective consensus can be determined by means of mode recommendations without compromise or confrontation among the parties. In the clinical example involving prostate cancer therapy, three parameters were used with two cut-off values each (Gleason score, PSA, T-stage) resulting in a total of 27 possible combinations per decision tree. Despite significant variations among the recommendations, a mode recommendation could be found for specific combinations of parameters.ConclusionRecommendations represented as decision trees can serve as a basis for objective consensus among multiple parties.
Resumo:
Instruments for on-farm determination of colostrum quality such as refractometers and densimeters are increasingly used in dairy farms. The colour of colostrum is also supposed to reflect its quality. A paler or mature milk-like colour is associated with a lower colostrum value in terms of its general composition compared with a more yellowish and darker colour. The objective of this study was to investigate the relationships between colour measurement of colostrum using the CIELAB colour space (CIE L*=from white to black, a*=from red to green, b*=from yellow to blue, chroma value G=visual perceived colourfulness) and its composition. Dairy cow colostrum samples (n=117) obtained at 4·7±1·5 h after parturition were analysed for immunoglobulin G (IgG) by ELISA and for fat, protein and lactose by infrared spectroscopy. For colour measurements, a calibrated spectrophotometer was used. At a cut-off value of 50 mg IgG/ml, colour measurement had a sensitivity of 50·0%, a specificity of 49·5%, and a negative predictive value of 87·9%. Colostral IgG concentration was not correlated with the chroma value G, but with relative lightness L*. While milk fat content showed a relationship to the parameters L*, a*, b* and G from the colour measurement, milk protein content was not correlated with a*, but with L*, b*, and G. Lactose concentration in colostrum showed only a relationship with b* and G. In conclusion, parameters of the colour measurement showed clear relationships to colostral IgG, fat, protein and lactose concentration in dairy cows. Implementation of colour measuring devices in automatic milking systems and milking parlours might be a potential instrument to access colostrum quality as well as detecting abnormal milk.
Resumo:
Aims To explore the impact of the functional severity of coronary artery stenosis on changes in myocardial oxygenation during pharmacological vasodilation, using oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR) imaging and invasive fractional flow reserve (FFR). An FFR is considered a standard of reference for assessing haemodynamic relevance of coronary artery stenosis; yet, the relationship of FFR to changes in myocardial oxygenation during vasodilator stress and thus to an objective marker for ischaemia on the tissue level is not well understood. Methods and results We prospectively recruited 64 patients with suspected/known coronary artery disease undergoing invasive angiography. The FFR was performed in intermediate coronary artery stenosis. OS-CMR images were acquired using a T2*-sensitive sequence before and after adenosine-induced vasodilation, with myocardial segments matched to angiography. Very strict image quality criteria were defined to ensure the validity of results. The FFR was performed in 37 patients. Because of the strict image quality criteria, 41% of segments had to be excluded, leaving 29/64 patients for the blinded OS-CMR analysis. Coronary territories with an associated FFR of <0.80 showed a lack of increase in myocardial oxygenation [mean signal intensity (ΔSI) −0.49%; 95% confidence interval (CI) −3.78 to 2.78 vs. +7.30%; 95% CI 4.08 to 10.64; P < 0.001]. An FFR of <0.54 best predicted a complete lack of a vasodilator-induced oxygenation increase (sensitivity 71% and specificity 75%). An OS-CMR ΔSI <4.78% identified an FFR of <0.8 with a sensitivity of 86% and specificity of 92%. Conclusion An FFR of <0.80 is associated with a lack of an adenosine-inducible increase in oxygenation of the dependent coronary territory, while a complete lack of such an increase was best predicted by an FFR of <0.54. Further studies are warranted to identify clinically meaningful cut-off values for FFR measurements and to assess the utility of OS-CMR as an alternative clinical tool for assessing the functional relevance of coronary artery stenosis.
Resumo:
AIM To evaluate the performance of a pen‑type laser fluorescence device (DIAGNOdent 2190; LFpen, KaVo, Germany) and bitewing radiographs (BW) for approximal caries detection in permanent and primary teeth. MATERIALS AND METHODS A total of 246 anterior approximal surfaces (102 permanent and 144 primary) were selected. Contact points were simulated using sound teeth. Two examiners assessed all approximal surfaces using LFpen and BW. The teeth were histologically assessed for the reference standard. Optimal cut‑off limits were calculated for LFpen for primary and permanent teeth. Sensitivity, specificity, accuracy and area under the receiver operating characteristic curve (Az) were calculated for D1 (enamel and dentin lesions) and D3 (dentin lesions) thresholds. The reproducibility was assessed by intraclass correlation coefficient (ICC) and Cohen's weighted kappa values. RESULTS For permanent teeth, the LFpen cut‑off were 0- 27 (sound), 28- 33 (enamel caries) and >33 (dentin caries). For primary teeth, the LFpen cut‑off were 0- 7 (sound), 8- 32 (enamelcaries) and >32 (dentin caries). The LFpen presented higher sensitivity values than BW for primary teeth (0.58 vs. 0.32 at D1 and 0.80 vs. 0.47 at D3) and permanent teeth (0.80 vs. 0.57 at D1 and 0.94 vs. 0.51 at D3). Specificity did not show a significant difference between the methods. Rank correlations with histology were 0.59 and 0.83 (LFpen) and 0.36 and 0.70 (BW) for primary and permanent teeth, respectively, considering all lesions. ICC values for LFpen were 0.71 (inter) and 0.86 (intra) for permanent teeth and 0.94 (inter) and 0.90/0.99 for primary teeth. Kappa values for BW were 0.69 (inter) and 0.68/0.90 (intra) for permanent teeth and 0.64 (inter) and 0.89/0.89 for primary teeth. CONCLUSION LFpen presented better reproducibility for primary and permanent teeth and higher accuracy in detecting caries lesions at D1 threshold than BW for permanent teeth. LFpen should be used as an adjunct method for approximal caries detection.
Resumo:
The 5th Assessment Report (AR5) of the Intergovernmental Panel on Climate Change (IPCC) states with very high certainty that anthropogenic emissions have caused measurable changes in the physical ocean environment. These changes are summarized with special focus on those that are predicted to have the strongest, most direct effects on ocean biological processes; namely, ocean warming and associated phenomena (including stratification and sea level rise) as well as deoxygenation and ocean acidification. The biological effects of these changes are then discussed for microbes (including phytoplankton), plants, animals, warm and cold-water corals, and ecosystems. The IPCC AR5 highlighted several areas related to both the physical and biological processes that required further research. As a rapidly developing field, there have been many pertinent studies published since the cut off dates for the AR5, which have increased our understanding of the processes at work. This study undertook an extensive review of recently published literature to update the findings of the AR5 and provide a synthesized review on the main issues facing future oceans. The level of detail provided in the AR5 and subsequent work provided a basis for constructing projections of the state of ocean ecosystems in 2100 under two the Representative Concentration Pathways RCP4.5 and 8.5. Finally the review highlights notable additions, clarifications and points of departure from AR5 provided by subsequent studies.
Resumo:
Histone RNA 3' processing in vitro produces one or more 5' cleavage products corresponding to the mature histone mRNA 3' end, and a group of 3' cleavage products whose 5' ends are mostly located several nucleotides downstream of the mRNA 3' end. The formation of these 3' products is coupled to the formation of 5' products and dependent on the U7 snRNP and a heat-labile processing factor. These short 3' products therefore are a true and general feature of the processing reaction. Identical 3' products are also formed from a model RNA containing all spacer nucleotides downstream of the mature mRNA 3' end, but no sequences from the mature mRNA. Again, this reaction is dependent on both the U7 snRNP and a heat-labile factor. Unlike the processing with a full-length histone pre-mRNA, this reaction produces only 3' but no 5' fragments. In addition, product formation is inhibited by addition of cap structures at the model RNA 5' end, indicating that product formation occurs by 5'-3' exonucleolytic degradation. This degradation of a model 3' product by a 5'-3' exonuclease suggests a mechanism for the release of the U7 snRNP after processing by shortening the cut-off histone spacer sequences base paired to U7 RNA.
Resumo:
Alpine heavy precipitation events often affect small catchments, although the circulation pattern leading to the event extends over the entire North Atlantic. The various scale interactions involved are particularly challenging for the numerical weather prediction of such events. Unlike previous studies focusing on the southern Alps, here a comprehensive study of a heavy precipitation event in the northern Alps in October 2011 is presented with particular focus on the role of the large-scale circulation in the North Atlantic/European region. During the event exceptionally high amounts of total precipitable water occurred in and north of the Alps. This moisture was initially transported along the flanks of a blocking ridge over the North Atlantic. Subsequently, strong and persistent northerly flow established at the upstream flank of a trough over Europe and steered the moisture towards the northern Alps. Lagrangian diagnostics reveal that a large fraction of the moisture emerged from the West African coast where a subtropical upper-level cut-off low served as an important moisture collector. Wave activity flux diagnostics show that the ridge was initiated as part of a low-frequency, large-scale Rossby wave train while convergence of fast transients helped to amplify it locally in the North Atlantic. A novel diagnostic for advective potential vorticity tendencies sheds more light on this amplification and further emphasizes the role of the ridge in amplifying the trough over Europe. Operational forecasts misrepresented the amplitude and orientation of this trough. For the first time, this study documents an important pathway for northern Alpine flooding, in which the interaction of synoptic-scale to large-scale weather systems and of long-range moisture transport from the Tropics are dominant. Moreover, the trapping of moisture in a subtropical cut-off near the West African coast is found to be a crucial precursor to the observed European high-impact weather.
Resumo:
Ab initio calculations of Afρ are presented using Mie scattering theory and a Direct Simulation Monte Carlo (DSMC) dust outflow model in support of the Rosetta mission and its target 67P/Churyumov-Gerasimenko (CG). These calculations are performed for particle sizes ranging from 0.010 μm to 1.0 cm. The present status of our knowledge of various differential particle size distributions is reviewed and a variety of particle size distributions is used to explore their effect on Afρ , and the dust mass production View the MathML sourcem˙. A new simple two parameter particle size distribution that curtails the effect of particles below 1 μm is developed. The contributions of all particle sizes are summed to get a resulting overall Afρ. The resultant Afρ could not easily be predicted a priori and turned out to be considerably more constraining regarding the mass loss rate than expected. It is found that a proper calculation of Afρ combined with a good Afρ measurement can constrain the dust/gas ratio in the coma of comets as well as other methods presently available. Phase curves of Afρ versus scattering angle are calculated and produce good agreement with observational data. The major conclusions of our calculations are: – The original definition of A in Afρ is problematical and Afρ should be: qsca(n,λ)×p(g)×f×ρqsca(n,λ)×p(g)×f×ρ. Nevertheless, we keep the present nomenclature of Afρ as a measured quantity for an ensemble of coma particles.– The ratio between Afρ and the dust mass loss rate View the MathML sourcem˙ is dominated by the particle size distribution. – For most particle size distributions presently in use, small particles in the range from 0.10 to 1.0 μm contribute a large fraction to Afρ. – Simplifying the calculation of Afρ by considering only large particles and approximating qsca does not represent a realistic model. Mie scattering theory or if necessary, more complex scattering calculations must be used. – For the commonly used particle size distribution, dn/da ∼ a−3.5 to a−4, there is a natural cut off in Afρ contribution for both small and large particles. – The scattering phase function must be taken into account for each particle size; otherwise the contribution of large particles can be over-estimated by a factor of 10. – Using an imaginary index of refraction of i = 0.10 does not produce sufficient backscattering to match observational data. – A mixture of dark particles with i ⩾ 0.10 and brighter silicate particles with i ⩽ 0.04 matches the observed phase curves quite well. – Using current observational constraints, we find the dust/gas mass-production ratio of CG at 1.3 AU is confined to a range of 0.03–0.5 with a reasonably likely value around 0.1.
Resumo:
Currently, most cosmic ray data are obtained by detectors on satellites, aircraft, high-altitude balloons and ground (neutron monitors). In our work, we examined whether Liulin semiconductor spectrometers (simple silicon planar diode detectors with spectrometric properties) located at high mountain observatories could contribute new information to the monitoring of cosmic rays by analyzing data from selected solar events between 2005 and 2013. The decision thresholds and detection limits of these detectors placed at Jungfraujoch (Switzerland; 3475 m a.s.l.; vertical cut-off rigidity 4.5 GV) and Lomnicky stıt (Slovakia; 2633 m a.s.l.; vertical cut-off rigidity 3.84 GV) highmountain observatories were determined. The data showed that only the strongest variations of the cosmic ray flux in this period were detectable. The main limitation in the performance of these detectors is their small sensitive volume and low sensitivity of the PIN photodiode to neutrons.
Resumo:
BACKGROUND Intravenous anaesthetic drugs are the primary means for producing general anaesthesia in equine practice. The ideal drug for intravenous anaesthesia has high reliability and pharmacokinetic properties indicating short elimination and lack of accumulation when administered for prolonged periods. Induction of general anaesthesia with racemic ketamine preceded by profound sedation has already an established place in the equine field anaesthesia. Due to potential advantages over racemic ketamine, S-ketamine has been employed in horses to induce general anaesthesia, but its optimal dose remains under investigation. The objective of this study was to evaluate whether 2.5 mg/kg S-ketamine could be used as a single intravenous bolus to provide short-term surgical anaesthesia in colts undergoing surgical castration, and to report its pharmacokinetic profile. RESULTS After premedication with romifidine and L-methadone, the combination of S-ketamine and diazepam allowed reaching surgical anaesthesia in the 28 colts. Induction of anaesthesia as well as recovery were good to excellent in the majority (n = 22 and 24, respectively) of the colts. Seven horses required additional administration of S-ketamine to prolong the duration of surgical anaesthesia. Redosing did not compromise recovery quality. Plasma concentration of S-ketamine decreased rapidly after administration, following a two-compartmental model, leading to the hypothesis of a consistent unchanged elimination of the parent compound into the urine beside its conversion to S-norketamine. The observed plasma concentrations of S-ketamine at the time of first movement were various and did not support the definition of a clear cut-off value to predict the termination of the drug effect. CONCLUSIONS The administration of 2.5 mg/kg IV S-ketamine after adequate premedication provided good quality of induction and recovery and a duration of action similar to what has been reported for racemic ketamine at the dose of 2.2 mg/kg. Until further investigations will be provided, close monitoring to adapt drug delivery is mandatory, particularly once the first 10 minutes after injection are elapsed. Taking into account rapid elimination of S-ketamine, significant inter-individual variability and rapid loss of effect over a narrow range of concentrations a sudden return of consciousness has to be foreseen.
Resumo:
People with sequence-space synesthesia (SSS) report stable visuo-spatial forms corresponding to numbers, days, and months (amongst others). This type of synesthesia has intrigued scientists for over 130 years but the lack of an agreed upon tool for assessing it has held back research on this phenomenon. The present study builds on previous tests by measuring the consistency of spatial locations that is known to discriminate controls from synesthetes. We document, for the first time, the sensitivity and specificity of such a test and suggest a diagnostic cut-off point for discriminating between the groups based on the area bounded by different placement attempts with the same item.
Resumo:
The most commonly used method for formally assessing grapheme-colour synaesthesia (i.e., experiencing colours in response to letter and/or number stimuli) involves selecting colours from a large colour palette on several occasions and measuring consistency of the colours selected. However, the ability to diagnose synaesthesia using this method depends on several factors that have not been directly contrasted. These include the type of colour space used (e.g., RGB, HSV, CIELUV, CIELAB) and different measures of consistency (e.g., city block and Euclidean distance in colour space). This study aims to find the most reliable way of diagnosing grapheme-colour synaesthesia based on maximising sensitivity (i.e., ability of a test to identify true synaesthetes) and specificity (i.e., ability of a test to identify true non-synaesthetes). We show, applying ROC (Receiver Operating Characteristics) to binary classification of a large sample of self-declared synaesthetes and non-synaesthetes, that the consistency criterion (i.e., cut-off value) for diagnosing synaesthesia is considerably higher than the current standard in the field. We also show that methods based on perceptual CIELUV and CIELAB colour models (rather than RGB and HSV colour representations) and Euclidean distances offer an even greater sensitivity and specificity than most currently used measures. Together, these findings offer improved heuristics for the behavioural assessment of grapheme-colour synaesthesia.
Resumo:
AIMS A non-invasive gene-expression profiling (GEP) test for rejection surveillance of heart transplant recipients originated in the USA. A European-based study, Cardiac Allograft Rejection Gene Expression Observational II Study (CARGO II), was conducted to further clinically validate the GEP test performance. METHODS AND RESULTS Blood samples for GEP testing (AlloMap(®), CareDx, Brisbane, CA, USA) were collected during post-transplant surveillance. The reference standard for rejection status was based on histopathology grading of tissue from endomyocardial biopsy. The area under the receiver operating characteristic curve (AUC-ROC), negative (NPVs), and positive predictive values (PPVs) for the GEP scores (range 0-39) were computed. Considering the GEP score of 34 as a cut-off (>6 months post-transplantation), 95.5% (381/399) of GEP tests were true negatives, 4.5% (18/399) were false negatives, 10.2% (6/59) were true positives, and 89.8% (53/59) were false positives. Based on 938 paired biopsies, the GEP test score AUC-ROC for distinguishing ≥3A rejection was 0.70 and 0.69 for ≥2-6 and >6 months post-transplantation, respectively. Depending on the chosen threshold score, the NPV and PPV range from 98.1 to 100% and 2.0 to 4.7%, respectively. CONCLUSION For ≥2-6 and >6 months post-transplantation, CARGO II GEP score performance (AUC-ROC = 0.70 and 0.69) is similar to the CARGO study results (AUC-ROC = 0.71 and 0.67). The low prevalence of ACR contributes to the high NPV and limited PPV of GEP testing. The choice of threshold score for practical use of GEP testing should consider overall clinical assessment of the patient's baseline risk for rejection.