95 resultados para Aneurysms


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to establish and validate a three-dimensional imaging protocol for the assessment of Computed Tomography (CT) scans of abdominal aortic aneurysms in UK EVAR trials patients. Quality control and repeatability of anatomical measurements is important for the validity of any core laboratory. METHODS: Three different observers performed anatomical measurements on 50 preoperative CT scans of aortic aneurysms using the Vitrea 2 three-dimensional post-imaging software in a core laboratory setting. We assessed the accuracy of intra and inter observer repeatability of measurements, the time required for collection of measurements, 3 different levels of automation and 3 different automated criteria for measurement of neck length. RESULTS: None of the automated neck length measurements demonstrated sufficient accuracy and it was necessary to perform checking of the important automated landmarks. Good intra and limited inter observer agreement were achieved with three-dimensional assessment. Complete assessment of the aneurysm and iliacs took an average (SD) of 17.2 (4.1) minutes. CONCLUSIONS: Aortic aneurysm anatomy can be assessed reliably and quickly using three-dimensional assessment but for scans of limited quality, manual checking of important landmarks remains necessary. Using a set protocol, agreement between observers is satisfactory but not as good as within observers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The standard technique of two-dimensional intra-arterial digital subtraction angiography (2D-DSA) for the imaging of experimental rabbit aneurysms is invasive and has considerable surgical risks. Therefore, minimally invasive techniques ideally providing three-dimensional imaging for intervention planning and follow-up are needed. This study evaluates the feasibility and quality of three-dimensional 3-T magnetic resonance angiography (3D-3T-MRA) and compares 3D-3T-MRA with 2D-DSA in experimental aneurysms in the rabbit. METHOD: Three microsurgically created aneurysms in three rabbits were evaluated using 2D-DSA and 3D-3T-MRA. Imaging of the aneurysms was performed 2 weeks after creation using 2D-DSA and contrast-enhanced (CE) MRA. Measurements included aneurysm dome (length and width) and aneurysm neck. Aneurysm volumes were determined using CE-MRA. RESULTS: The measurements of the aneurysms' dimensions and the evaluation of vicinity vessels with both techniques showed a good correlation. The mean aneurysm length, aneurysm width and neck width measured with DSA (6.9, 4.1 and 2.8 mm, respectively) correlated with the measurements performed in 3D-3T-MRA (6.9, 4 and 2.5 mm, respectively). The mean aneurysm volumes measured with CE-MRA was 46.7 mm(3). CONCLUSION: 3D-3T CE-MRA is feasible and less invasive and is a safer imaging alternative to DSA for experimental aneurysm. Additionally, aneurysm technique this precise offers the possibility of repetitive 3D aneurysm volumetry for long-term follow-up studies after endovascular aneurysm occlusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abdominal aortic aneurysms (AAA) confer a substantial healthcare burden in the Western world. Surgical or endovascular therapy is indicated in patients with a maximum diameter exceeding 5.5 cm. Patients with smaller AAA must undergo a specific ultrasound surveillance program aimed at avoiding exposure to an increased risk of rupture once their AAA exceeds the threshold for active treatment. Based on improved understanding of the pathophysiology of AAA, recent years provided initial insight into potential medical treatment options. The presence of AAA is currently regarded a coronary artery disease risk equivalent. ACE inhibitors, statins and JNK-inhibitors were shown to have the potential to slow down progression. Since cigarette smoking is the main risk factor for both the development and progression of AAA, smoking cessation remains a key goal. Further prospective studies will assess the clinical efficacy of various promising drug treatment approaches aimed at slowing disease progression of small AAA and after endovascular therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Vasospastic brain infarction is a devastating complication of aneurysmal subarachnoid hemorrhage (SAH). Using a probe for invasive monitoring of brain tissue oxygenation or blood flow is highly focal and may miss the site of cerebral vasospasm (CVS). Probe placement is based on the assumption that the spasm will occur either at the dependent vessel territory of the parent artery of the ruptured aneurysm or at the artery exposed to the focal thick blood clot. We investigated the likelihood of a focal monitoring sensor being placed in vasospasm or infarction territory on a hypothetical basis. METHODS From our database we retrospectively selected consecutive SAH patients with angiographically proven (day 7-14) severe CVS (narrowing of vessel lumen >50%). Depending on the aneurysm location we applied a standard protocol of probe placement to detect the most probable site of severe CVS or infarction. We analyzed whether the placement was congruent with existing CVS/infarction. RESULTS We analyzed 100 patients after SAH caused by aneurysms located in the following locations: MCA (n = 14), ICA (n = 30), A1CA (n = 4), AcoA or A2CA (n = 33), and VBA (n = 19). Sensor location corresponded with CVS territory in 93% of MCA, 87% of ICA, 76% of AcoA or A2CA, but only 50% of A1CA and 42% of VBA aneurysms. The focal probe was located inside the infarction territory in 95% of ICA, 89% of MCA, 78% of ACoA or A2CA, 50% of A1CA and 23% of VBA aneurysms. CONCLUSION The probability that a single focal probe will be situated in the territory of severe CVS and infarction varies. It seems to be reasonably accurate for MCA and ICA aneurysms, but not for ACA or VBA aneurysms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To analyse our results of using a double arterial perfusion strategy to avoid lower body hypothermic circulatory arrest after extensive thoracic aortic surgery. METHODS We analysed the intra- and perioperative courses of 10 patients (median age 58 years, median logistic EuroSCORE 14.6) who underwent extensive thoracic aortic surgery with a double arterial perfusion strategy. The main goal of double arterial perfusion is to separate myocardial and supra-aortic from systemic perfusion. Aortic repair starts at the most distal level of the descending aorta, followed by reinsertion of the supra-aortic vessels, and ends with completion of the proximal anastomosis or by any kind of root repair as needed. RESULTS Seven of 10 patients had prior surgery of the thoracic aorta. Indications for surgery were post-dissection aneurysm in 4 patients, true aneurysm in 3, anastomotic aneurysms in 2 and Type B aortic dissection with pseudo-coarctation in 1. Surgical access was performed through median sternotomy with left hemi-clamshell extension in all cases. There was no in-hospital mortality, but perioperative neurological symptoms occurred in 2 patients. These 2 patients developed delayed stroke (after awaking) after an initial uneventful clinical course, and in 1 of them, neurological symptoms resolved completely during follow-up. The median follow-up was 7 (±13) months. There was no death and no need for additional redo surgery during this observational period. CONCLUSIONS Extensive surgery of the thoracic aorta using a double arterial perfusion technique in order to avoid lower body hypothermic circulatory arrest is an attractive option. Further refinements of this technique may enable the safe and effective simultaneous multisegmental treatment of thoracic aortic pathology in patients who would otherwise have to undergo a two-step surgical approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The purpose of this study was to assess the occurrence, predictors, and mechanisms of optical coherence tomography (OCT)-detected coronary evaginations following drug-eluting stent (DES) implantation. BACKGROUND Angiographic ectasias and aneurysms in stented segments have been associated with a risk of late stent thrombosis. Using OCT, some stented segments show coronary evaginations reminiscent of ectasias. METHODS Evaginations were defined as outward bulges in the luminal contour between struts. They were considered major evaginations (MEs) when extending ≥3 mm along the vessel length, with a depth ≥10% of the stent diameter. A total of 228 patients who had sirolimus (SES)-, paclitaxel-, biolimus-, everolimus (EES)-, or zotarolimus (ZES)-eluting stents implanted in 254 lesions, were analysed after 1, 2, or 5 years; and serial assessment using OCT and intravascular ultrasound (IVUS) was performed post-intervention and after 1 year in 42 patients. RESULTS Major evaginations occurred frequently at all time points in SES (∼26%) and were rarely seen in EES (3%) and ZES (2%, P = 0.003). Sirolimus-eluting stent implantation was the strongest independent predictor of ME [adjusted OR (95% CI) 9.1 (1.1-77.4), P = 0.008]. Malapposed and uncovered struts were more common in lesions with vs. without ME (77 vs. 25%, P < 0.001 and 95 vs. 20%, P < 0.001, respectively) as was thrombus [49 vs. 14%, OR 7.3 (95% CI: 1.7-31.2), P = 0.007]. Post-intervention intra-stent dissection and protrusion of the vessel wall into the lumen were associated with an increased risk of evagination at follow-up [OR (95% CI): 2.9 (1.8-4.9), P < 0.001 and 3.3 (1.6-6.9), P = 0.001, respectively]. In paired IVUS analyses, lesions with ME showed a larger increase in the external elastic membrane area (20% area change) compared with lesions without ME (5% area change, P < 0.001). CONCLUSION Optical coherence tomography-detected MEs are a specific morphological footprint of early-generation SES and are nearly absent in newer-generation ZES and EES. Evaginations appear to be related to vessel injury at baseline; are associated with positive vessel remodelling; and correlate with uncoverage, malapposition, and thrombus at follow-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: Angiographic ectasias and aneurysms in stented segments have been associated with late stent thrombosis. Using optical coherence tomography (OCT), some stented segments show coronary evaginations reminiscent of ectasias. The purpose of this study was to explore, using computational fluid-dynamic (CFD) simulations, whether OCT-detected coronary evaginations can induce local changes in blood flow. Methods and results: OCT-detected evaginations are defined as outward bulges in the luminal vessel contour between struts, with the depth of the bulge exceeding the actual strut thickness. Evaginations can be characterised cross ectionally by depth and along the stented segment by total length. Assuming an ellipsoid shape, we modelled 3-D evaginations with different sizes by varying the depth from 0.2-1.0 mm, and the length from 1-9 mm. For the flow simulation we used average flow velocity data from non-diseased coronary arteries. The change in flow with varying evagination sizes was assessed using a particle tracing test where the particle transit time within the segment with evagination was compared with that of a control vessel. The presence of the evagination caused a delayed particle transit time which increased with the evagination size. The change in flow consisted locally of recirculation within the evagination, as well as flow deceleration due to a larger lumen - seen as a deflection of flow towards the evagination. Conclusions: CFD simulation of 3-D evaginations and blood flow suggests that evaginations affect flow locally, with a flow disturbance that increases with increasing evagination size.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulmonary artery aneurysm in adults is a rare diagnosis. Most cases described in the literature are either associated with congenital heart disease or pulmonal arterial hypertension, respectively, or are not true aneurysms but rather pseudoaneurysms, which are usually iatrogenic. We present the case of a 68-year old female patient with the incidental finding of a true aneurysm of the right peripheral pulmonary artery with a maximum diameter of 4 cm. With increasing aneurysm diameter over time, the decision for a surgical resection was made. Complete resection of the aneurysm including lower lobe resection was performed. Histopathological examination showed necrotizing giant cell arteritis as the underlying cause. The postoperative course was uneventful and no signs of further disease activity were detected. To our knowledge, this is the first reported case of a pulmonary artery aneurysm caused by giant cell arteritis, whereas it should be noted that the distinction between Takayasu arteritis and giant cell arteritis is not clearly defined. Considering the high mortality associated with aneurysm rupture, surveillance is advocated for small aneurysms, whereas for larger aneurysms and those showing signs of progression in size despite medical therapy or even dissection, surgical intervention should be considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) as well as thoracic and abdominal endovascular aortic repair (TEVAR and EVAR) rely on accurate pre- and postprocedural imaging. This review article discusses the application of imaging, including preprocedural assessment and measurements as well as postprocedural imaging of complications. Furthermore, the exciting perspective of computational fluid dynamics (CFD) based on cross-sectional imaging is presented. TAVR is a minimally invasive alternative for treatment of aortic valve stenosis in patients with high age and multiple comorbidities who cannot undergo traditional open surgical repair. Given the lack of direct visualization during the procedure, pre- and peri-procedural imaging forms an essential part of the intervention. Computed tomography angiography (CTA) is the imaging modality of choice for preprocedural planning. Routine postprocedural follow-up is performed by echocardiography to confirm treatment success and detect complications. EVAR and TEVAR are minimally invasive alternatives to open surgical repair of aortic pathologies. CTA constitutes the preferred imaging modality for both preoperative planning and postoperative follow-up including detection of endoleaks. Magnetic resonance imaging is an excellent alternative to CT for postoperative follow-up, and is especially beneficial for younger patients given the lack of radiation. Ultrasound is applied in screening and postoperative follow-up of abdominal aortic aneurysms, but cross-sectional imaging is required once abnormalities are detected. Contrast-enhanced ultrasound may be as sensitive as CTA in detecting endoleaks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To analyse the results after elective open total aortic arch replacement. METHODS We analysed 39 patients (median age 63 years, median logistic EuroSCORE 18.4) who underwent elective open total arch replacement between 2005 and 2012. RESULTS In-hospital mortality was 5.1% (n = 2) and perioperative neurological injury was 12.8% (n = 5). The indication for surgery was degenerative aneurysmal disease in 59% (n = 23) and late aneurysmal formation following previous surgery of type A aortic dissection in 35.9% (n = 14); 5.1% (n = 2) were due to anastomotical aneurysms after prior ascending repair. Fifty-nine percent (n = 23) of the patients had already undergone previous proximal thoracic aortic surgery. In 30.8% (n = 12) of them, a conventional elephant trunk was added to total arch replacement, in 28.2% (n = 11), root replacement was additionally performed. Median hypothermic circulatory arrest time was 42 min (21-54 min). Selective antegrade cerebral perfusion was used in 95% (n = 37) of patients. Median follow-up was 11 months [interquartile range (IQR) 1-20 months]. There was no late death and no need for reoperation during this period. CONCLUSIONS Open total aortic arch replacement shows very satisfying results. The number of patients undergoing total arch replacement as a redo procedure and as a part of a complex multisegmental aortic pathology is high. Future strategies will have to emphasize neurological protection in extensive simultaneous replacement of the aortic arch and adjacent segments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The population-based effectiveness of thoracic endovascular aortic repair (TEVAR) versus open surgery for descending thoracic aortic aneurysm remains in doubt. METHODS Patients aged over 50 years, without a history of aortic dissection, undergoing repair of a thoracic aortic aneurysm between 2006 and 2011 were assessed using mortality-linked individual patient data from Hospital Episode Statistics (England). The principal outcomes were 30-day operative mortality, long-term survival (5 years) and aortic-related reinterventions. TEVAR and open repair were compared using crude and multivariable models that adjusted for age and sex. RESULTS Overall, 759 patients underwent thoracic aortic aneurysm repair, mainly for intact aneurysms (618, 81·4 per cent). Median ages of TEVAR and open cohorts were 73 and 71 years respectively (P < 0·001), with more men undergoing TEVAR (P = 0·004). For intact aneurysms, the operative mortality rate was similar for TEVAR and open repair (6·5 versus 7·6 per cent; odds ratio 0·79, 95 per cent confidence interval (c.i.) 0·41 to 1·49), but the 5-year survival rate was significantly worse after TEVAR (54·2 versus 65·6 per cent; adjusted hazard ratio 1·45, 95 per cent c.i. 1·08 to 1·94). After 5 years, aortic-related mortality was similar in the two groups, but cardiopulmonary mortality was higher after TEVAR. TEVAR was associated with more aortic-related reinterventions (23·1 versus 14·3 per cent; adjusted HR 1·70, 95 per cent c.i. 1·11 to 2·60). There were 141 procedures for ruptured thoracic aneurysm (97 TEVAR, 44 open), with TEVAR showing no significant advantage in terms of operative mortality. CONCLUSION In England, operative mortality for degenerative descending thoracic aneurysm was similar after either TEVAR or open repair. Patients who had TEVAR appeared to have a higher reintervention rate and worse long-term survival, possibly owing to cardiopulmonary morbidity and other selection bias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: A number of intrinsic and extrinsic risk factors for the rupture of intracranial aneurysms have been identified. Still, the cause precipitating aneurysm rupture remains unknown in many cases. In addition, it has been observed that aneurysm ruptures are clustered in time but the trigger mechanism remains obscure. As solar activity has been associated with cardiovascular mortality and morbidity we decided to study ist association to aneurysm rupture in the Swiss population. Method: Patient data was extracted from the Swiss SOS database, at time of analysis covering 918 patients with angiography-proven aSAH treated at seven Swiss neurovascular centers between 01/01/2009 – 12/31/2011. The number of aneurysm rupture per day, week, month (Daily/Weekly/Monthly Rupture Frequency = RF) was measured and correlated to the absolute amount and the change in various parameters of interest representing continuous measurements of solar activity (radioflux (F10.7 index), solar proton flux, solar flare occurrence, planetary K-index/planetary A-index) using Poisson regression analysis. Results: Of a consecutive series of 918 cases of SAH, precise determination of the date of symptom onset was possible in 816 (88.9%). During the period of interest there were 517 days without recorded aneurysm rupture. There were 398, 139, 27 and 12 days with 1, 2, 3, and 4 ruptures per day. Five or 6 ruptures were only noted on a single day each. Poisson regression analysis demonstrated a significant correlation of F10.7 index and aneurysm rupture (incidence rate ratio (IRR) = 1.006303; standard error (SE) 0.0013201; 95% confidence interval (CI) 1.003719 – 1.008894; p<0.001), according to which every 1-unit increase of the F10.7 index increased the count for an aneurysm to rupture by 0.63%. As the F10.7 index is known to correlate well with the Space Environment Services Center (SESC) sunspot number, we performed additional analyses on SESC sunspot number and sunspot area. Here, a likewise statistically significant relationship of both the SESC sunspot number (IRR 1.003413; SE 0.0007913; 95%CI 1.001864 – 1.004965; p<0.001) and the sunspot area (IRR 1.000419; SE 0.0000866; 95%CI 1.000249 – 1.000589; p<0.001) emerged. All other variables analyzed showed no correlation with RF. Conclusions: Using valid methods, we found higher radioflux, sunspot number and sunspot area to be associated with an increased count of aneurysm rupture. Since we were using rupture frequencies rather than incidences and because we cannot explain the physiological basis of this statistical association, the clinical meaningfulness of this statistical association must be interpreted carefully. Future studies are warranted to rule out a type-1 error.