128 resultados para validation study


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this in vitro study was to assess the agreement among four techniques used as gold standard for the validation of methods for occlusal caries detection. Sixty-five human permanent molars were selected and one site in each occlusal surface was chosen as the test site. The teeth were cut and prepared according to each technique: stereomicroscopy without coloring (1), dye enhancement with rhodamine B (2) and fuchsine/acetic light green (3), and semi-quantitative microradiography (4). Digital photographs from each prepared tooth were assessed by three examiners for caries extension. Weighted kappa, as well as Friedman's test with multiple comparisons, was performed to compare all techniques and verify statistical significant differences. Results: kappa values varied from 0.62 to 0.78, the latter being found by both dye enhancement methods. Friedman's test showed statistical significant difference (P < 0.001) and multiple comparison identified these differences among all techniques, except between both dye enhancement methods (rhodamine B and fuchsine/acetic light green). Cross-tabulation showed that the stereomicroscopy overscored the lesions. Both dye enhancement methods showed a good agreement, while stereomicroscopy overscored the lesions. Furthermore, the outcome of caries diagnostic tests may be influenced by the validation method applied. Dye enhancement methods seem to be reliable as gold standard methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A real-time polymerase chain reaction (PCR) assay was developed for rapid identification of Bacillus anthracis in environmental samples. These samples often harbor Bacillus cereus bacteria closely related to B. anthracis, which may hinder its specific identification by resulting in false positive signals. The assay consists of two duplex real-time PCR: the first PCR allows amplification of a sequence specific of the B. cereus group (B. anthracis, B. cereus, Bacillus thuringiensis, Bacillus weihenstephanensis, Bacillus pseudomycoides, and Bacillus mycoides) within the phosphoenolpyruvate/sugar phosphotransferase system I gene and a B. anthracis specific single nucleotide polymorphism within the adenylosuccinate synthetase gene. The second real-time PCR assay targets the lethal factor gene from virulence plasmid pXO1 and the capsule synthesis gene from virulence plasmid pXO2. Specificity of the assay is enhanced by the use of minor groove binding probes and/or locked nucleic acids probes. The assay was validated on 304 bacterial strains including 37 B. anthracis, 67 B. cereus group, 54 strains of non-cereus group Bacillus, and 146 Gram-positive and Gram-negative bacteria strains. The assay was performed on various environmental samples spiked with B. anthracis or B. cereus spores. The assay allowed an accurate identification of B. anthracis in environmental samples. This study provides a rapid and reliable method for improving rapid identification of B. anthracis in field operational conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluation and validation of the psychometric properties of the eight-item modified Medical Outcomes Study Social Support Survey (mMOS-SS).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to validate the accuracy and reproducibility of a statistical shape model-based 2D/3D reconstruction method for determining cup orientation after total hip arthroplasty. With a statistical shape model, this method allows reconstructing a patient-specific 3D-model of the pelvis from a standard AP X-ray radiograph. Cup orientation (inclination and anteversion) is then calculated with respect to the anterior pelvic plane that is derived from the reconstructed model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the accuracy of hypodense regions in non-contrast-enhanced cardiac computed tomography (unenhanced CT) to identify nonviable myocardial scar tissue.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The Conners Adult ADHD Rating Scales (CAARS) assess symptoms specific to adults that are frequently used and have been translated into German. The current study tests the factor structure of the CAARS in a large sample of German adults with ADHD and compares the means of the CAARS subscales with those of healthy German controls. Method: CAARS were completed by 466 participants with ADHD and 851 healthy control participants. Confirmatory factor analysis was used to establish model fit with the American original. Comparisons between participants with ADHD and healthy controls and influences of gender, age, and degree of education were analyzed. Results: Confirmatory factor analysis showed a very good fit with the model for the American original. Differences between ADHD participants and healthy controls on all Conners Adult ADHD Rating Scales-Self-Report (CAARS-S) subscales were substantial and significant. Conclusion: The factor structure of the original American model was successfully replicated in this sample of adult German ADHD participants. (J. of Att. Dis. 2012; XX(X) 1-XX).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The German version of the Conners Adult ADHD Rating Scales (CAARS) has proven to show very high model fit in confirmative factor analyses with the established factors inattention/memory problems, hyperactivity/restlessness, impulsivity/emotional lability, and problems with self-concept in both large healthy control and ADHD patient samples. This study now presents data on the psychometric properties of the German CAARS-self-report (CAARS-S) and observer-report (CAARS-O) questionnaires.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

What's known on the subject? and What does the study add? One area of particular growth for robotic surgery has been partial nephrectomy. Despite a perceived notion that robotic-assisted partial nephrectomy is more easily adaptable compared to laparoscopic partial nephrectomy, there is nonetheless an associated learning curve. Validated training models with a corresponding assessment method for robotic-assisted partial nephrectomy were previously unavailable. We have designed and validated a RAPN surgical model appropriate for resident and fellow training.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In chronic haemodialysis patients, anaemia is a frequent finding associated with high therapeutic costs and further expenses resulting from serial laboratory measurements. HemoHue HH1, HemoHue Ltd, is a novel tool consisting of a visual scale for the noninvasive assessment of anaemia by matching the coloration of the conjunctiva with a calibrated hue scale. The aim of the study was to investigate the usefulness of HemoHue in estimating individual haemoglobin concentrations and binary treatment outcomes in haemodialysis patients. A prospective blinded study with 80 hemodialysis patients comparing the visual haemoglobin assessment with the standard laboratory measurement was performed. Each patient's haemoglobin concentration was estimated by seven different medical and nonmedical observers with variable degrees of clinical experience on two different occasions. The estimated population mean was close to the measured one (11.06 ± 1.67 versus 11.32 ± 1.23 g/dL, P < 0.0005). A learning effect could be detected. Relative errors in individual estimates reached, however, up to 50%. Insufficient performance in predicting binary outcomes (ROC AUC: 0.72 to 0.78) and poor interrater reliability (Kappa < 0.6) further characterised this method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: Myocardial blood flow (MBF) is the gold standard to assess myocardial blood supply and, as recently shown, can be obtained by myocardial contrast echocardiography (MCE). The aims of this human study are (i) to test whether measurements of collateral-derived MBF by MCE are feasible during elective angioplasty and (ii) to validate the concept of pressure-derived collateral-flow assessment. METHODS AND RESULTS: Thirty patients with stable coronary artery disease underwent MCE of the collateral-receiving territory during and after angioplasty of 37 stenoses. MCE perfusion analysis was successful in 32 cases. MBF during and after angioplasty varied between 0.060-0.876 mL min(-1) g(-1) (0.304+/-0.196 mL min(-1) g(-1)) and 0.676-1.773 mL min(-1) g(-1) (1.207+/-0.327 mL min(-1) g(-1)), respectively. Collateral-perfusion index (CPI) is defined as the rate of MBF during and after angioplasty varied between 0.05 and 0.67 (0.26+/-0.15). During angioplasty, simultaneous measurements of mean aortic pressure, coronary wedge pressure, and central venous pressure determined the pressure-derived collateral-flow index (CFI(p)), which varied between 0.04 and 0.61 (0.23+/-0.14). Linear-regression analysis demonstrated an excellent agreement between CFI(p) and CPI (y=0.88 x +0.01; r(2)=0.92; P<0.0001). CONCLUSION: Collateral-derived MBF measurements by MCE during angioplasty are feasible and proved that the pressure-derived CFI exactly reflects collateral relative to normal myocardial perfusion in humans.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To validate the Probability of Repeated Admission (Pra) questionnaire, a widely used self-administered tool for predicting future healthcare use in older persons, in three European healthcare systems. DESIGN: Prospective study with 1-year follow-up. SETTING: Hamburg, Germany; London, United Kingdom; Canton of Solothurn, Switzerland. PARTICIPANTS: Nine thousand seven hundred thirteen independently living community-dwelling people aged 65 and older. MEASUREMENTS: Self-administered eight-item Pra questionnaire at baseline. Self-reported number of hospital admissions and physician visits during 1 year of follow-up. RESULTS: In the combined sample, areas under the receiver operating characteristic curves (AUCs) were 0.64 (95% confidence interval (CI)=0.62-0.66) for the prediction of one or more hospital admissions and 0.68 (95% CI=0.66-0.69) for the prediction of more than six physician visits during the following year. AUCs were similar between sites. In comparison, prediction models based on a person's age and sex alone exhibited poor predictive validity (AUC or= 0.5) were 2.3 times as likely (95% CI=2.1-2.6) as low-risk individuals to have a hospital admission, and 2.1 times as likely (95% CI=2.0-2.2) to have more than six physician visits. CONCLUSION: The Pra instrument exhibits good validity for predicting future health service use on a population level in different healthcare settings. Administrative data have shown similar predictive validity, but in practice, such data are often not available. The Pra is likely of high interest to governments and health insurance companies worldwide as a basis for programs aimed at health risk management in older persons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article reports about the internet based, second multicenter study (MCS II) of the spine study group (AG WS) of the German trauma association (DGU). It represents a continuation of the first study conducted between the years 1994 and 1996 (MCS I). For the purpose of one common, centralised data capture methodology, a newly developed internet-based data collection system ( http://www.memdoc.org ) of the Institute for Evaluative Research in Orthopaedic Surgery of the University of Bern was used. The aim of this first publication on the MCS II was to describe in detail the new method of data collection and the structure of the developed data base system, via internet. The goal of the study was the assessment of the current state of treatment for fresh traumatic injuries of the thoracolumbar spine in the German speaking part of Europe. For that reason, we intended to collect large number of cases and representative, valid information about the radiographic, clinical and subjective treatment outcomes. Thanks to the new study design of MCS II, not only the common surgical treatment concepts, but also the new and constantly broadening spectrum of spine surgery, i.e. vertebro-/kyphoplasty, computer assisted surgery and navigation, minimal-invasive, and endoscopic techniques, documented and evaluated. We present a first statistical overview and preliminary analysis of 18 centers from Germany and Austria that participated in MCS II. A real time data capture at source was made possible by the constant availability of the data collection system via internet access. Following the principle of an application service provider, software, questionnaires and validation routines are located on a central server, which is accessed from the periphery (hospitals) by means of standard Internet browsers. By that, costly and time consuming software installation and maintenance of local data repositories are avoided and, more importantly, cumbersome migration of data into one integrated database becomes obsolete. Finally, this set-up also replaces traditional systems wherein paper questionnaires were mailed to the central study office and entered by hand whereby incomplete or incorrect forms always represent a resource consuming problem and source of error. With the new study concept and the expanded inclusion criteria of MCS II 1, 251 case histories with admission and surgical data were collected. This remarkable number of interventions documented during 24 months represents an increase of 183% compared to the previously conducted MCS I. The concept and technical feasibility of the MEMdoc data collection system was proven, as the participants of the MCS II succeeded in collecting data ever published on the largest series of patients with spinal injuries treated within a 2 year period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objectives of this study were to develop and validate a tool for assessing pain in population-based observational studies and to develop three subscales for back/neck, upper extremity and lower extremity pain. Based on a literature review, items were extracted from validated questionnaires and reviewed by an expert panel. The initial questionnaire consisted of a pain manikin and 34 items relating to (i) intensity of pain in different body regions (7 items), (ii) pain during activities of daily living (18 items) and (iii) various pain modalities (9 items). Psychometric validation of the initial questionnaire was performed in a random sample of the German-speaking Swiss population. Analyses included tests for reliability, correlation analysis, principal components factor analysis, tests for internal consistency and validity. Overall, 16,634 of 23,763 eligible individuals participated (70%). Test-retest reliability coefficients ranged from 0.32 to 0.97, but only three coefficients were below 0.60. Subscales were constructed combining four items for each of the subscales. Item-total coefficients ranged from 0.76 to 0.86 and Cronbach's alpha were 0.75 or higher for all subscales. Correlation coefficients between subscales and three validated instruments (WOMAC, SPADI and Oswestry) ranged from 0.62 to 0.79. The final Pain Standard Evaluation Questionnaire (SEQ Pain) included 28 items and the pain manikin and accounted for the multidimensionality of pain by assessing pain location and intensity, pain during activity, triggers and time of onset of pain and frequency of pain medication. It was found to be reliable and valid for the assessment of pain in population-based observational studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: The aim of this study was to determine which of two clinically applied methods, electromyography or acceleromyography, was less affected by external disturbances, had a higher sensitivity and which would provide the better input signal for closed loop control of muscle relaxation. METHODS: In 14 adult patients, anaesthesia was induced with intravenous opioids and propofol. The response of the thumb to ulnar nerve stimulation was recorded on the same arm. Mivacurium was used for neuromuscular blockade. Under stable conditions of relaxation, the infusion-rate was decreased and the effects of turning the hand were investigated. RESULTS: Electromyography and acceleromyography both reflected the change of the infusion rate (P = 0.015 and P < 0.001, respectively). Electromyography was significantly less affected by the hand-turn (P = 0.008) than acceleromyography. While zero counts were detected with acceleromyography, electromyography could still detect at least one count in 51.1%. CONCLUSIONS: Electromyography is more reliable for use in daily practice as it is less influenced by external disturbances than acceleromyography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clinical efficacy of aerosol therapy in premature newborns depends on the efficiency of delivery of aerosolized drug to the bronchial tree. To study the influence of various anatomical, physical, and physiological factors on aerosol delivery in preterm newborns, it is crucial to have appropriate in vitro models, which are currently not available. We therefore constructed the premature infant nose throat-model (PrINT-Model), an upper airway model corresponding to a premature infant of 32-wk gestational age by three-dimensional (3D) reconstruction of a three-planar magnetic resonance imaging scan and subsequent 3D-printing. Validation was realized by visual comparison and comparison of total airway volume. To study the feasibility of measuring aerosol deposition, budesonide was aerosolized through the cast and lung dose was expressed as percentage of nominal dose. The airway volumes of the initial magnetic resonance imaging and validation computed tomography scan showed a relative deviation of 0.94%. Lung dose at low flow (1 L/min) was 61.84% and 9.00% at high flow (10 L/min), p < 0.0001. 3D-reconstruction provided an anatomically accurate surrogate of the upper airways of a 32-wk-old premature infant, making the model suitable for future in vitro testing.