70 resultados para secretory product


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Every joint registry aims to improve patient care by identifying implants that have an inferior performance. For this reason, each registry records the implant name that has been used in the individual patient. In most registries, a paper-based approach has been utilized for this purpose. However, in addition to being time-consuming, this approach does not account for the fact that failure patterns are not necessarily implant specific but can be associated with design features that are used in a number of implants. Therefore, we aimed to develop and evaluate an implant product library that allows both time saving barcode scanning on site in the hospital for the registration of the implant components and a detailed description of implant specifications. MATERIALS AND METHODS A task force consisting of representatives of the German Arthroplasty Registry, industry, and computer specialists agreed on a solution that allows barcode scanning of implant components and that also uses a detailed standardized classification describing arthroplasty components. The manufacturers classified all their components that are sold in Germany according to this classification. The implant database was analyzed regarding the completeness of components by algorithms and real-time data. RESULTS The implant library could be set up successfully. At this point, the implant database includes more than 38,000 items, of which all were classified by the manufacturers according to the predefined scheme. Using patient data from the German Arthroplasty Registry, several errors in the database were detected, all of which were corrected by the respective implant manufacturers. CONCLUSIONS The implant library that was developed for the German Arthroplasty Registry allows not only on-site barcode scanning for the registration of the implant components but also its classification tree allows a sophisticated analysis regarding implant characteristics, regardless of brand or manufacturer. The database is maintained by the implant manufacturers, thereby allowing registries to focus their resources on other areas of research. The database might represent a possible global model, which might encourage harmonization between joint replacement registries enabling comparisons between joint replacement registries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CODE, the Center for Orbit Determination in Europe, is a joint venture of the following four institutions: Astronomical Institute, University of Bern (AIUB), Bern, Switzerland; Federal Office of Topography swisstopo, Wabern, Switzerland; Federal Agency of Cartography and Geodesy (BKG), Frankfurt a. M., Germany; Institut für Astronomische und Physikalische Geodäsie, Technische Universität München (IAPG, TUM), Munich, Germany. It acts as a global analysis center of the International GNSS Service (IGS). The operational computations are performed at AIUB using the latest development version of the Bernese GNSS Software. In this context an ultra-rapid solution series is generated considering GPS and GLONASS satellites. It is updated several times per day and contains 24 hours of observed and 24 hours of predicted orbit interval. More details are available in: Lutz, S., G. Beutler, S. Schaer, R. Dach, A. Jäggi; 2014: CODE's new ultra-rapid orbit and ERP products for the IGS. GPS Solutions. DOI 10.1007/s10291-014-0432-2

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CODE, the Center for Orbit Determination in Europe, is a joint venture of the following four institutions: • Astronomical Institute, University of Bern (AIUB), Bern, Switzerland • Federal Office of Topography swisstopo, Wabern, Switzerland • Federal Agency of Cartography and Geodesy (BKG), Frankfurt a. M., Germany • Institut für Astronomische und Physikalische Geodäsie, Technische Universität München (IAPG, TUM), Munich, Germany It acts as a global analysis center of the International GNSS Service (IGS, Dow et al, 2009). The operational computations are performed at AIUB using the latest development version of the Bernese GNSS Software (Dach et al., 2015). In this context the contribution to the IGS repro02 effort is generated considering only the GPS satellites between 1994 and 2001 as well as the GPS and GLONASS satellites from 2002 to the end of 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CODE, the Center for Orbit Determination in Europe, is a joint venture of the following four institutions: Astronomical Institute, University of Bern (AIUB), Bern, Switzerland;Federal Office of Topography swisstopo, Wabern, Switzerland; Federal Agency of Cartography and Geodesy (BKG), Frankfurt a. M., Germany; Institut für Astronomische und Physikalische Geodäsie, Technische Universität München (IAPG, TUM), Munich, Germany. It acts as a global analysis center of the International GNSS Service (IGS). The operational computations are performed at AIUB using the latest development version of the Bernese GNSS Software (Dach et al., 2015). In this context a rapid solution series is generated considering all active GPS and GLONASS satellites. It contains 24 hours of observed orbits and published at the day after the observations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CODE, the Center for Orbit Determination in Europe, is a joint venture of the following four institutions:Astronomical Institute, University of Bern (AIUB), Bern, Switzerland; Federal Office of Topography swisstopo, Wabern, Switzerland; Federal Agency of Cartography and Geodesy (BKG), Frankfurt a. M., Germany; Institut für Astronomische und Physikalische Geodäsie, Technische Universität München (IAPG, TUM), Munich, Germany. It acts as a global analysis center of the International GNSS Service (IGS). The operational computations are performed at AIUB using the latest development version of the Bernese GNSS Software. In this context a final solution series is generated considering all active GPS and GLONASS satellites. It is published in daily files with a delay of about two weeks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CODE, the Center for Orbit Determination in Europe, is a joint venture of the following four institutions: Astronomical Institute, University of Bern (AIUB), Bern, Switzerland; Federal Office of Topography swisstopo, Wabern, Switzerland; Federal Agency of Cartography and Geodesy (BKG), Frankfurt a. M., Germany; Institut für Astronomische und Physikalische Geodäsie, Technische Universität München (IAPG, TUM), Munich, Germany. It acts as a global analysis center of the International GNSS Service (IGS). The operational computations are performed at AIUB using the latest development version of the Bernese GNSS Software. In this context a multi-GNSS solution is generated considering all active GPS, GLONASS, Galileo, BeiDou (expect for GEOs), and QZSS satellites as a contribution to the IGS-MGEX project. The results are published with a delay of about two weeks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In literary genetics, “editorial genetics” deals with the “public life” of texts, whereas the writing process is affected by edition and diffusion. Editorial genetics frequently has to deal with cases of “editorial rewriting”: in the literary domain for example, authors frequently modify previously published works, so that several versions may co-exist. We are especially interested in Balzac’s La Bourse (translated in English as The Purse) since we know three authorized versions of this specific work.By comparing different texts associated with a single work, the literary geneticist is facing different products that are themselves the result of a writing process. However, different specificities should be outlined: (1) the writing process does not leave any trace: we just have access to different products/texts and (2) since the texts we compare seem to be achieved, differences must be referred, not to programmatic or temporary linguistic structures, but to the reconfiguration of a pre-existing textuality.Do such products still reflect the processes that have given birth to them? Does the comparison between two texts considered as variations of a same text give access to this transformation’s processes? After describing the objects of this particular textual comparison and the terminology that permits to give an account of such phenomenon, this contribution suggests to express these questions differently, as a matter of poetics of transitions between texts, or, further digging, an hermeneutics of the transition between texts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endometriosis is a gynecologic disease that is characterized by nonspecific symptoms and invasive diagnostics. To date, there is no adequate noninvasive method for the diagnosis of endometriosis. Although more than 100 potential biomarkers have been investigated in blood and/or peritoneal fluid, none of these has proven useful in clinical practice. The aim to find a suitable panel of biomarkers that would allow noninvasive diagnosis thus remains of interest. We evaluated the concentrations of 16 cytokines and other secretory proteins in serum and peritoneal fluid of 58 women with ovarian endometriosis (cases) and 40 healthy women undergoing sterilization or patients with benign ovarian cysts (controls) using multiplexed double fluorescence-based immunometric assay platform and enzyme-linked immunosorbent assay. Significantly higher concentrations of glycodelin-A were shown in serum, and significantly higher levels of glycodelin-A, IL-6, and IL-8, and lower levels of leptin were measured in the peritoneal fluid of cases versus controls. In serum, the best performance was shown by models that included the ratio of leptin/glycodelin-A and the ratio of ficolin 2/glycodelin-A, whereas in the peritoneal fluid the best models included the ratio of biglycan/leptin, regulated on activation normal T-cell expressed and secreted/IL-6 and ficolin-2/glycodelin-A, and IL-8 per milligram of total protein, all in combination with age. The models using serum and peritoneal fluid distinguished between ovarian endometriosis patients and controls regardless of the menstrual cycle phase with relatively high sensitivity (72.5% to 84.2%), specificity (78.4% to 91.2%), and area under the curve (0.85 to 0.90).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The p67 sporozoite antigen of Theileria parva has been fused to the C-terminal secretion signal of Escherichia coli hemolysin and expressed in secreted form by attenuated Salmonella dublin aroA strain SL5631. The recombinant p67 antigen was detected in the supernatant of transformed bacterial cultures. Immunization trials in cattle revealed that SL5631 secreting the antigen provoked a 10-fold-higher antibody response to p67 than recombinant SL5631 expressing but not secreting p67. Immunized calves were challenged with a 80% lethal dose of T. parva sporozoites and monitored for the development of infection. Two of three calves immunized intramuscularly with the p67-secreting SL5631 strain were found to be protected, whereas only one of three animals immunized with the nonsecreting p67-expressing SL5631 strain was protected. This is the first demonstration that complete eukaryotic antigens fused to the C-terminal portion of E. coli hemolysin can be exported from attenuated Salmonella strains and that such exported antigens can protect cattle against subsequent parasite challenge.