83 resultados para quality index of the square


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction The purpose of this paper is to present the technical specifications of the Forensic Reference Phantom (FRP), to test its behavior relative to organic test materials, and discuss potential applications of the phantom in forensic radiology. Materials and method The FRP prototype is made of synthetic materials designed to simulate the computed tomography (CT) attenuation of water. It has six bore holes that accommodate multiuse containers. These containers were filled with test materials and scanned at 80 kVp, 120 kVp, and 140 kVp. X-ray attenuation was measured by two readers. Intra- and inter-reader reliability was assessed using the intra-class correlation coefficient (ICC). Significance levels between mean CT numbers at 80 kVp, 120 kVp, and 140 kVp were assessed with the Friedman-test. The T-test was used to assess significance levels between the FRP and water. Results Overall mean CT numbers ranged from −3.0–3.7HU for the FRP; −1000.3–−993.5HU for air; −157.7– −108.1HU for oil; 35.5–42.0HU for musle tissue; and 1301.5–2354.8HU for cortical bone. Inter-reader and intra-reader reliability were excellent (ICC>0.994; and ICC=0.999 respectively). CT numbers were significantly different at different energy levels. There was no significant difference between the attenuation of the FRP and water. Conclusions The FRP is a new tool for quality assurance and research in forensic radiology. The mean CT attenuation of the FRP is equivalent to water. The phantom can be scanned during routine post-mortem CT to assess the composition of unidentified objects. In addition, the FRP may be used to investigate new imaging algorithms and scan protocols in forensic radiology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Osteoarthritis is the most common form of joint disease and the leading cause of pain and physical disability in older people. Opioids may be a viable treatment option if people have severe pain or if other analgesics are contraindicated. However, the evidence about their effectiveness and safety is contradictory. This is an update of a Cochrane review first published in 2009. OBJECTIVES To determine the effects on pain, function, safety, and addiction of oral or transdermal opioids compared with placebo or no intervention in people with knee or hip osteoarthritis. SEARCH METHODS We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE and CINAHL (up to 28 July 2008, with an update performed on 15 August 2012), checked conference proceedings, reference lists, and contacted authors. SELECTION CRITERIA We included randomised or quasi-randomised controlled trials that compared oral or transdermal opioids with placebo or no treatment in people with knee or hip osteoarthritis. We excluded studies of tramadol. We applied no language restrictions. DATA COLLECTION AND ANALYSIS We extracted data in duplicate. We calculated standardised mean differences (SMDs) and 95% confidence intervals (CI) for pain and function, and risk ratios for safety outcomes. We combined trials using an inverse-variance random-effects meta-analysis. MAIN RESULTS We identified 12 additional trials and included 22 trials with 8275 participants in this update. Oral oxycodone was studied in 10 trials, transdermal buprenorphine and oral tapentadol in four, oral codeine in three, oral morphine and oral oxymorphone in two, and transdermal fentanyl and oral hydromorphone in one trial each. All trials were described as double-blind, but the risk of bias for other domains was unclear in several trials due to incomplete reporting. Opioids were more beneficial in pain reduction than control interventions (SMD -0.28, 95% CI -0.35 to -0.20), which corresponds to a difference in pain scores of 0.7 cm on a 10-cm visual analogue scale (VAS) between opioids and placebo. This corresponds to a difference in improvement of 12% (95% CI 9% to 15%) between opioids (41% mean improvement from baseline) and placebo (29% mean improvement from baseline), which translates into a number needed to treat (NNTB) to cause one additional treatment response on pain of 10 (95% CI 8 to 14). Improvement of function was larger in opioid-treated participants compared with control groups (SMD -0.26, 95% CI -0.35 to -0.17), which corresponds to a difference in function scores of 0.6 units between opioids and placebo on a standardised Western Ontario and McMaster Universities Arthritis Index (WOMAC) disability scale ranging from 0 to 10. This corresponds to a difference in improvement of 11% (95% CI 7% to 14%) between opioids (32% mean improvement from baseline) and placebo (21% mean improvement from baseline), which translates into an NNTB to cause one additional treatment response on function of 11 (95% CI 7 to 14). We did not find substantial differences in effects according to type of opioid, analgesic potency, route of administration, daily dose, methodological quality of trials, and type of funding. Trials with treatment durations of four weeks or less showed larger pain relief than trials with longer treatment duration (P value for interaction = 0.001) and there was evidence for funnel plot asymmetry (P value = 0.054 for pain and P value = 0.011 for function). Adverse events were more frequent in participants receiving opioids compared with control. The pooled risk ratio was 1.49 (95% CI 1.35 to 1.63) for any adverse event (9 trials; 22% of participants in opioid and 15% of participants in control treatment experienced side effects), 3.76 (95% CI 2.93 to 4.82) for drop-outs due to adverse events (19 trials; 6.4% of participants in opioid and 1.7% of participants in control treatment dropped out due to adverse events), and 3.35 (95% CI 0.83 to 13.56) for serious adverse events (2 trials; 1.3% of participants in opioid and 0.4% of participants in control treatment experienced serious adverse events). Withdrawal symptoms occurred more often in opioid compared with control treatment (odds ratio (OR) 2.76, 95% CI 2.02 to 3.77; 3 trials; 2.4% of participants in opioid and 0.9% of participants control treatment experienced withdrawal symptoms). AUTHORS' CONCLUSIONS The small mean benefit of non-tramadol opioids are contrasted by significant increases in the risk of adverse events. For the pain outcome in particular, observed effects were of questionable clinical relevance since the 95% CI did not include the minimal clinically important difference of 0.37 SMDs, which corresponds to 0.9 cm on a 10-cm VAS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BackgroundThe PEmb-QoL is a validated 40-item questionnaire to quantify health-related quality of life in patients having experienced pulmonary embolism (PE). It covers six health dimensions: frequency of complaints, activities of daily living limitations, work-related problems, social limitations, intensity of complaints, and emotional complaints. Originally developed in Dutch and English, we sought to prospectively validate the psychometric properties of a French version of the PEmb-QoL.MethodsWe performed a forward and backward translation of the English version of the PEmb-QoL into French. French-speaking consecutive adult patients with an acute, objectively confirmed PE admitted to the emergency department of a Swiss university hospital between 08/2009 and 09/2011 were recruited telephonically. We used standard psychometric tests and criteria to evaluate the acceptability, reliability, and validity of the French version of the PEmb-QoL. We also performed an exploratory factor analysis.ResultsOverall, 102 patients were enrolled in the study. The French version of the PEmb-QoL showed good reliability (internal consistency, item¿total and inter-item correlations), reproducibility (test-retest reliability), and validity (convergent, discriminant) in French-speaking patients with PE. The exploratory factor analysis suggested three underlying dimensions: limitations in daily activity (items 4b-m, 5a-d), symptoms (items 1a-h and 7), and emotional complaints (items 9a-f and j).ConclusionWe successfully validated the French version of the PEmb-QoL questionnaire in patients with PE. Our results show that the PEmb-QoL is a valuable tool for assessing health-related quality of life after PE in French-speaking patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a cohort study among 2751 members (71.5% females) of the German and Swiss RLS patient organizations changes in restless legs syndrome (RLS) severity over time was assessed and the impact on quality of life, sleep quality and depressive symptoms was analysed. A standard set of scales (RLS severity scale IRLS, SF-36, Pittsburgh Sleep Quality Index and the Centre for Epidemiologic Studies Depression Scale) in mailed questionnaires was repeatedly used to assess RLS severity and health status over time and a 7-day diary once to assess short-term variations. A clinically relevant change of the RLS severity was defined by a change of at least 5 points on the IRLS scale. During 36 months follow-up minimal improvement of RLS severity between assessments was observed. Men consistently reported higher severity scores. RLS severity increased with age reaching a plateau in the age group 45-54 years. During 3 years 60.2% of the participants had no relevant (±5 points) change in RLS severity. RLS worsening was significantly related to an increase in depressive symptoms and a decrease in sleep quality and quality of life. The short-term variation showed distinctive circadian patterns with rhythm magnitudes strongly related to RLS severity. The majority of participants had a stable course of severe RLS over three years. An increase in RLS severity was accompanied by a small to moderate negative, a decrease by a small positive influence on quality of life, depressive symptoms and sleep quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Current demographic changes are characterized by population aging, such that the surgical treatment of degenerative spine conditions in the elderly is gaining increasing relevance. However, there is a general reluctance to consider spinal fusion procedures in this patient age group due to the increased likelihood of complications. The aim of this study was to assess the patient-rated outcome and complication rates associated with lumbar fusion procedures in three different age groups. Methods: This was a retrospective analysis of prospectively collected data from consecutive patients who underwent first-time, one to three level posterior instrumented fusion between 2004 and 2011, due to degenerative disease of the lumbar spine. Data were obtained from our Spine Surgery Outcomes Database (linked to the International Spine Tango Register). Before surgery, patients completed the multidimensional Core Outcome Measures Index (COMI), and at 3 and 12 months after surgery they completed the COMI and rated the Global Treatment Outcome (GTO) and their satisfaction with care. Patients were divided into three groups according to their age: younger (≥50y <65y; n = 317), older (≥65y <80y; n = 350), and geriatric (≥ 80y; n = 40). Results: 707 consecutive patients were included. The preoperative comorbidity status differed significantly (p < 0.0001) between the age groups, with the highest scores in the geriatric group. General medical complications during surgery were lower in the younger age group (7%) than in the older (13.4%; p = 0.006) and geriatric groups (17.5%; p = 0.007). Duration of hospital stay was longer (p = 0.006) in the older group (10.8 ± 3.7 days) than the younger (10.0 ± 3.6 days) group. There were no significant group differences (p>0.05) for any of the COMI domains covering pain, function, symptom specific well-being, general quality of life, and social and work disability at either 3 months’ or 12 months’ follow-up. Similarly, there were no differences (p>0.05) between the age groups for GTO and patient-rated satisfaction at either follow-up. Conclusions: Preoperative comorbidity and general medical complications during lumbar fusion for degenerative disorders of the lumbar spine are both greater in geriatric patients than in younger patients. However, patient-rated outcome is as good in the elderly as it is in younger age groups. These data suggest that geriatric age per se is not a contraindication to instrumented fusion for lumbar degenerative disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Retinal optical coherence tomography (OCT) permits quantification of retinal layer atrophy relevant to assessment of neurodegeneration in multiple sclerosis (MS). Measurement artefacts may limit the use of OCT to MS research. OBJECTIVE An expert task force convened with the aim to provide guidance on the use of validated quality control (QC) criteria for the use of OCT in MS research and clinical trials. METHODS A prospective multi-centre (n = 13) study. Peripapillary ring scan QC rating of an OCT training set (n = 50) was followed by a test set (n = 50). Inter-rater agreement was calculated using kappa statistics. Results were discussed at a round table after the assessment had taken place. RESULTS The inter-rater QC agreement was substantial (kappa = 0.7). Disagreement was found highest for judging signal strength (kappa = 0.40). Future steps to resolve these issues were discussed. CONCLUSION Substantial agreement for QC assessment was achieved with aid of the OSCAR-IB criteria. The task force has developed a website for free online training and QC certification. The criteria may prove useful for future research and trials in MS using OCT as a secondary outcome measure in a multi-centre setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND AIMS Inflammatory bowel disease (IBD) frequently manifests during childhood and adolescence. For providing and understanding a comprehensive picture of a patients' health status, health-related quality of life (HRQoL) instruments are an essential complement to clinical symptoms and functional limitations. Currently, the IMPACT-III questionnaire is one of the most frequently used disease-specific HRQoL instrument among patients with IBD. However, there is a lack of studies examining the validation and reliability of this instrument. METHODS 146 paediatric IBD patients from the multicenter Swiss IBD paediatric cohort study database were included in the study. Medical and laboratory data were extracted from the hospital records. HRQoL data were assessed by means of standardized questionnaires filled out by the patients in a face-to-face interview. RESULTS The original six IMPACT-III domain scales could not be replicated in the current sample. A principal component analysis with the extraction of four factor scores revealed the most robust solution. The four factors indicated good internal reliability (Cronbach's alpha=.64-.86), good concurrent validity measured by correlations with the generic KIDSCREEN-27 scales and excellent discriminant validity for the dimension of physical functioning measured by HRQoL differences for active and inactive severity groups (p<.001, d=1.04). CONCLUSIONS This study with Swiss children with IBD indicates good validity and reliability for the IMPACT-III questionnaire. However, our findings suggest a slightly different factor structure than originally proposed. The IMPACT-III questionnaire can be recommended for its use in clinical practice. The factor structure should be further examined in other samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE The SWISSspine registry (SSR) was launched in 2005 to assess the safety and effectiveness of balloon kyphoplasty (BKP). In the meantime, repeated reports on high rates of adjacent vertebral fractures (ASF) after BKP of vertebral insufficiency fractures were published. The causes for ASF and their risk factors are still under debate. The purpose of this study was to report the incidence and potential risk factors of ASF within the SSR dataset. METHODS The SSR data points are collected perioperatively and during follow-ups, with surgeon- and patient-based information. All patients documented with a monosegmental osteoporotic vertebral insufficiency fracture between March 2005 and May 2012 were included in the study. The incidence of ASF, significant associations with co-variates (patient age, gender, fracture location, cement volume, preoperative segmental kyphosis, extent of kyphosis correction, and individual co-morbidities) and influence on quality of life (EQ-5D) and back pain (VAS) were analyzed. RESULTS A total of 375 patients with a mean follow-up of 3.6 months was included. ASF were found in 9.9 % (n = 37) and occurred on average 2.8 months postoperatively. Preoperative segmental kyphosis >30° (p = 0.026), and rheumatoid arthritis (p = 0.038) and cardiovascular disease (p = 0.047) were significantly associated with ASF. Furthermore, patients with ASF had significantly higher back pain at the final follow-up (p = 0.001). No further significant associations between the studied co-variates and ASF were seen in the adjusted analysis. CONCLUSIONS The findings suggest that patients with a preoperative segmental kyphosis >30° or patients with co-morbidities like rheumatoid arthritis and a cardiovascular disease are at high risk of ASF within 6 months after the index surgery. In case of an ASF event, back pain levels are significantly increased. LEVEL OF EVIDENCE IV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In recent years, the WHO Wellbeing Index (WHO-5) has been used as a screening measure for depression. Nevertheless, research on the validity of this measure in the context of clinical depression is sparse. QUESTIONS: The aim of the present study was to investigate the measurement invariance of the WHO-5 across depressed and non-depressed individuals, as well as the shape and specificity of its relationship to measures of depression severity. METHOD: Of the 414 subjects who completed the WHO-5 and the Beck Depression Inventory-II (BDI-II), 207 had a diagnosis of a major depressive episode (MDE). A subsample also completed the Beck Anxiety Inventory (BAI) and was assessed by clinicians using the Hamilton Depression Rating Scale (HAM-D) and the Hamilton Anxiety Rating Scale (HAM-A). RESULTS: The WHO-5 demonstrated strong measurement invariance regarding the presence or absence of a current MDE. The WHO-5 showed a very high negative association with self- and observer-rated measures of depressive symptoms, especially in the range of mild to moderate symptoms. These associations were still substantial after controlling for measures of anxiety symptoms. LIMITATIONS: In addition to a diagnostic interview, only one measure for self- and observer-rated symptoms of depression was used. Furthermore, the observer-rated measure was only assessed in one subsample that exhibited a somewhat restricted range of depression severity. CONCLUSION: Although this index was originally designed as a measure of well-being, the results support the use of the WHO-5 in the context of depression research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Multi-GNSS Experiment (MGEX) of the International GNSS Service (IGS) aims at the data collection and analysis of all available satellite navigation systems. In particular the new global and regional satellite navigation systems are of interest, i.e., the European Galileo, the Chinese BeiDou, the Japanese QZSS as well as satellite based augmentation systems. This article analyzes the orbit and clock quality of the Galileo products of four MGEX analysis centers for a common time period of 20 weeks. Orbit comparisons of the individual analysis centers have a consistency at the 5–30 cm level. Day boundary discontinuities range from 4 to 28 cm whereas 2-day orbit fit RMS values vary between 1 and 7 cm. The accuracy evaluated by satellite laser ranging residuals is on the one decimeter level with a systematic bias of about −5 cm for all analysis centers. In addition, systematic errors on the decimeter level related to solar radiation pressure mismodeling are present in all orbit products. Due to the correlation of radial orbit errors with the clock parameters, these errors are also visible as a bump in the Allan deviation of the Galileo satellite clocks at the orbital frequency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The Pulmonary Embolism Quality of Life questionnaire (PEmb-QoL) is a 40-item questionnaire to measure health-related quality of life in patients with pulmonary embolism. It covers six 6 dimensions: frequency of complaints, limitations in activities of daily living, work-related problems, social limitations, intensity of complaints, and emotional complaints. Originally developed in Dutch and English, we prospectively validated a German version of the PEmb-QoL. METHODS A forward-backward translation of the English version of the PEmb-QoL into German was performed. German-speaking consecutive adult patients aged ≥18 years with an acute, objectively confirmed pulmonary embolism discharged from a Swiss university hospital (01/2011-06/2013) were recruited telephonically. Established psychometric tests and criteria were used to evaluate the acceptability, reliability, and validity of the German PEmb-QoL questionnaire. To assess the underlying dimensions, an exploratory factor analysis was performed. RESULTS Overall, 102 patients were enrolled in the study. The German version of the PEmb-QoL showed a good internal consistency (Cronbach's alpha ranging from 0.72 to 0.96), item-total (0.53-0.95) and inter-item correlations (>0.4), and test-retest reliability (intra-class correlation coefficients 0.59-0.89) for the dimension scores. A moderate correlation of the PEmb-QoL with SF-36 dimension and summary scores (0.21-0.83) indicated convergent validity, while low correlations of PEmb-QoL dimensions with clinical characteristics (-0.16-0.37) supported discriminant validity. The exploratory factor analysis suggested four underlying dimensions: limitations in daily activities, symptoms, work-related problems, and emotional complaints. CONCLUSION The German version of the PEmb-QoL questionnaire is a valid and reliable disease-specific measure for quality of life in patients with pulmonary embolism.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the long term oncological and functional outcomes after readaptation of the dorsolateral peritoneal layer following pelvic lymph node dissection (PLND) and cystectomy . PATIENTS AND METHODS A randomised, single-center, single-blinded, two-arm trial was conducted on 200 consecutive cystectomy patients who underwent PLND and cystectomy for bladder cancer (of the dorsolateral peritoneal layer (n=100; 73 male, 27 female; median age 68 yrs, range 35-86 yrs) and group B without readapation (n=100; 66 male, 34 female; median age 65 yrs, range 30-86 yrs). Regular postoperative follow-up was performed at our outpatient clinic. Median follow-up was 59 months (range 3-100 months), five patients were lost to follow-up in group A, seven in group B. Bowel function was evaluated using the validated Gastrointestinal Quality of Life Index questionnaire and an institutional questionnaire regarding post-cystectomy outcome. Local recurrences and distal metastases were evaluated using computed tomography and bone scan at the regular follow-up visits. RESULTS There was no significant difference between the two groups in terms of the rate of local (pelvic) recurrence (5/95 [5.3%] in group A; 7/93 [7.5%] in group B; p = 0.53), the rate of distant metastases (21/95 [22.1%] in group A; 23/93 [24.7%] in group B; p = 0.67), cancer-specific survival (p = 0.37), and overall survival (p = 0.59). Group A had significantly better bowel function at 3 (p < 0.001), 6 (p < 0.006), 12 (p <0.006) and 24 months (p = 0.04), and significantly less postoperative abdominal pain and bloating at 3 (p = 0.002) and 6 months (p = 0.01). CONCLUSION Readaptation of the dorsolateral peritoneal layer following PLND and cystectomy has a beneficial long-term impact on bowel function and postoperative pain without compromising oncological radicality. This article is protected by copyright. All rights reserved.