79 resultados para dialysis interface
Resumo:
International agencies and programmes introduced sustainable land management (SLM) to Central Asia after the former Soviet Republics became independent in 1991. An aim of early SLM initiatives was to address challenges linked to the transformation of the agricultural sector from a centrally planned economy to a decentralized market economy. This article analyses the knowledge–action interface in Kyrgyzstan and Tajikistan as it relates to SLM. The analysis focuses on the influence of underlying land management concepts by means of a literature review. Contemporary barriers at the research–action interface were identified using participatory appraisal. And a historically contextualized understanding of the effectiveness of interactions between researchers, policy makers and practitioners is based on an analysis of purposefully selected cases. The study concludes that knowledge of different stakeholder groups is often highly disconnected. Interdisciplinary and transdisciplinary studies are rare, and academic research on SLM has subsequently been ineffective at contributing to substantial benefits for society. Further, researchers, policy makers and practitioners in this context must recognize the differences between SLM and what is often referred to as the equivalent Soviet-era concept—rational use of land resources—and the resulting implications of these differences. The authors recommend the following: creating an enabling environment for SLM research through academic institutional reform removing structural constraints, making research outcomes more effective by applying systems approaches that produce evidence for policy makers on the multiple benefits of SLM, helping land users evaluate SLM strategies and investing in the establishment and maintenance of a multi-stakeholder SLM platform that allows dynamic exchange.
Resumo:
In many designs for radioactive waste repositories, cement and clay will come into direct contact. The geochemical contrast between cement and clay will lead to mass fluxes across the interface, which consequently results in alteration of structural and transport properties of both materials that may affect the performance of the multi-barrier system. We present an experimental approach to study cement-clay interactions with a cell to accommodate small samples of cement and clay. The cell design allows both in situ measurement of water content across the sample using neutron radiography and measurement of transport parameters using through-diffusion tracer experiments. The aim of the high- resolution neutron radiography experiments was to monitor changes in water content (porosity) and their spatial extent. Neutron radiographs of several evolving cement-clay interfaces delivered quantitative data which allow resolving local water contents within the sample domain. In the present work we explored the uncertainties of the derived water contents with regard to various input parameters and with regard to the applied image correction procedures. Temporal variation of measurement conditions created absolute uncertainty of the water content in the order of ±0.1 (m3/m3), which could not be fully accounted for by correction procedures. Smaller relative changes in water content between two images can be derived by specific calibrations to two sample regions with different, invariant water contents.
Resumo:
Blood loss and bleeding complications may often be observed in critically ill patients on renal replacement therapies (RRT). Here we investigate procedural (i.e. RRT-related) and non-procedural blood loss as well as transfusion requirements in regard to the chosen mode of dialysis (i.e. intermittent haemodialysis [IHD] versus continuous veno-venous haemofiltration [CVVH]). Two hundred and fifty-two patients (122 CVVH, 159 male; aged 61.5±13.9 years) with dialysis-dependent acute renal failure were analysed in a sub-analysis of the prospective randomised controlled clinical trial-CONVINT-comparing IHD and CVVH. Bleeding complications including severity of bleeding and RRT-related blood loss were assessed. We observed that 3.6% of patients died related to severe bleeding episodes (between group P=0.94). Major all-cause bleeding complications were observed in 23% IHD versus 26% of CVVH group patients (P=0.95). Under CVVH, the rate of RRT-related blood loss events (57.4% versus 30.4%, P=0.01) and mean total blood volume lost was increased (222.3±291.9 versus 112.5±222.7 ml per patient, P <0.001). Overall, transfusion rates did not differ between the study groups. In patients with sepsis, transfusion rates of all blood products were significantly higher when compared to cardiogenic shock (all P <0.01) or other conditions. In conclusion, procedural and non-procedural blood loss may often be observed in critically ill patients on RRT. In CVVH-treated patients, procedural blood loss was increased but overall transfusion rates remained unchanged. Our data show that IHD and CVVH may be regarded as equivalent approaches in critically ill patients with dialysis-dependent acute renal failure in this regard.
Resumo:
Today, a growing activity to improve patient safety in all domains of medicine is reality. This chapter deals with patient safety research in general, but is also about strategies to implement this evidence in the daily clinical work treating patients on dialysis. Good clinical research practice has been well established for some years. In the domain of dialysis access, further basic, clinical, epidemiological and health service research will be important to further improve patient safety as a whole.
Resumo:
Operating room (OR) team safety training and learning in the field of dialysis access is well suited for the use of simulators, simulated case learning and root cause analysis of adverse outcomes. The objectives of OR team training are to improve communication and leadership skills, to use checklists and to prevent errors. Other objectives are to promote a change in the attitudes towards vascular access from learning through mistakes in a nonpunitive environment, to positively impact the employee performance and to increase staff retention by making the workplace safer, more efficient and user friendly.
Resumo:
Peritoneal transport characteristics and residual renal function require regular control and subsequent adjustment of the peritoneal dialysis (PD) prescription. Prescription models shall facilitate the prediction of the outcome of such adaptations for a given patient. In the present study, the prescription model implemented in the PatientOnLine software was validated in patients requiring a prescription change. This multicenter, international prospective cohort study with the aim to validate a PD prescription model included patients treated with continuous ambulatory peritoneal dialysis. Patients were examined with the peritoneal function test (PFT) to determine the outcome of their current prescription and the necessity for a prescription change. For these patients, a new prescription was modeled using the PatientOnLine software (Fresenius Medical Care, Bad Homburg, Germany). Two to four weeks after implementation of the new PD regimen, a second PFT was performed. The validation of the prescription model included 54 patients. Predicted and measured peritoneal Kt/V were 1.52 ± 0.31 and 1.66 ± 0.35, and total (peritoneal + renal) Kt/V values were 1.96 ± 0.48 and 2.06 ± 0.44, respectively. Predicted and measured peritoneal creatinine clearances were 42.9 ± 8.6 and 43.0 ± 8.8 L/1.73 m2/week and total creatinine clearances were 65.3 ± 26.0 and 63.3 ± 21.8 L/1.73 m2/week, respectively. The analysis revealed a Pearson's correlation coefficient for peritoneal Kt/V of 0.911 and Lin's concordance coefficient of 0.829. The value of both coefficients was 0.853 for peritoneal creatinine clearance. Predicted and measured daily net ultrafiltration was 0.77 ± 0.49 and 1.16 ± 0.63 L/24 h, respectively. Pearson's correlation and Lin's concordance coefficient were 0.518 and 0.402, respectively. Predicted and measured peritoneal glucose absorption was 125.8 ± 38.8 and 79.9 ± 30.7 g/24 h, respectively, and Pearson's correlation and Lin's concordance coefficient were 0.914 and 0.477, respectively. With good predictability of peritoneal Kt/V and creatinine clearance, the present model provides support for individual dialysis prescription in clinical practice. Peritoneal glucose absorption and ultrafiltration are less predictable and are likely to be influenced by additional clinical factors to be taken into consideration.
Resumo:
Not only are dialysis access creation and maintenance prone to complications, but patients suffering from end-stage renal disease and its comorbidities generally have a high risk of adverse events during their continuous treatment. Preventive strategies are key to avoid harm and to improve the outcome of the treatment of the growing number of patients with chronic kidney failure, especially as doctors and nurses are not always aware of the consequences of unsafe behavior. This publication is intended for health care professionals – nurses as well as doctors – and aims to raise the awareness of patient safety aspects, combining medical education with evidence-based medicine. After a general overview of the topic, an international panel of authors provides a diversified insight into important concepts and technical tricks essential to create and maintain a functional dialysis access. Contributions to Nephrology, Vol. 184
Resumo:
A new haptic interface device is suggested, which can be used for functional magnetic resonance imaging (fMRI) studies. The basic component of this 1 DOF haptic device are two coils that produce a Lorentz force induced by the large static magnetic field of the MR scanner. A MR-compatible optical angular encoder and a optical force sensor enable the implementation of different control architectures for haptic interactions. The challenge was to provide a large torque, and not to affect image quality by the currents applied in the device. The haptic device was tested in a 3T MR scanner. With a current of up to 1A and a distance of 1m to the focal point of the MR-scanner it was possible to generate torques of up to 4 Nm. Within these boundaries image quality was not affected.
Resumo:
Interplay of spin, charge, orbital and lattice degrees of freedom in oxide heterostructures results in a plethora of fascinating properties, which can be exploited in new generations of electronic devices with enhanced functionalities. The paradigm example is the interface between the two band insulators LaAlO3 and SrTiO3 that hosts a two-dimensional electron system. Apart from the mobile charge carriers, this system exhibits a range of intriguing properties such as field effect, superconductivity and ferromagnetism, whose fundamental origins are still debated. Here we use soft-X-ray angle-resolved photoelectron spectroscopy to penetrate through the LaAlO3 overlayer and access charge carriers at the buried interface. The experimental spectral function directly identifies the interface charge carriers as large polarons, emerging from coupling of charge and lattice degrees of freedom, and involving two phonons of different energy and thermal activity. This phenomenon fundamentally limits the carrier mobility and explains its puzzling drop at high temperatures.