106 resultados para central venous pressure
Resumo:
BACKGROUND Low levels of testosterone in men and changes in retinal microvascular calibre are both associated with hypertension and cardiovascular disease risk. Sex hormones are also associated with blood flow in microvascular beds which might be a key intermediate mechanism in the development of hypertension. Whether a direct association between endogenous testosterone and retinal microvascular calibre exists is currently unknown. We aimed to determine whether testosterone is independently associated with ocular perfusion via a possible association with retinal vascular calibre or whether it plays only a secondary role via its effect on blood pressure in a bi-ethnic male cohort. PROBANDS AND METHODS A total of 72 black and 81 white men (28-68 years of age) from the follow-up phase of the Sympathetic activity and Ambulatory Blood Pressure in Africans (SABPA) study were included in this sub-study. Ambulatory pulse pressure and intraocular perfusion pressures were obtained, while metabolic variables and testosterone were measured from fasting venous blood samples. Retinal vascular calibre was quantified from digital photographs using standardised protocols. RESULTS The black men revealed a poorer cardiometabolic profile and higher pulsatile pressure (>50 mm Hg), intraocular pressure and diastolic ocular perfusion pressure than the white men (p≤0.05). Only in the white men was free testosterone positively associated with retinal calibre, i.e. arterio-venular ratio and central retinal arterial calibre and inversely with central retinal venular calibre. These associations were not found in the black men, independent of whether pulse pressure and ocular perfusion pressure were part of the model. CONCLUSIONS These results suggest an independent, protective effect of testosterone on the retinal vasculature where an apparent vasodilatory response in the retinal resistance microvessels was observed in white men.
Resumo:
OBJECTIVE: To evaluate the ease of application of two-piece, graduated, compression systems for the treatment of venous ulcers. METHODS: Four kits used to provide limb compression in the management of venous ulcers were evaluated. These have been proven to be non-inferior to various types of bandages in clinical trials. The interface pressure exerted above the ankle by the under-stocking and the complete compression system and the force required to pull the over-stocking off were assessed in vitro. Ease of application of the four kits was evaluated in four sessions by five nurses who put stockings on their own legs in a blinded manner. They expressed their assessment of the stockings using a series of visual analogue scales (VASs). RESULTS: The Sigvaris Ulcer X((R)) kit provided a mean interface pressure of 46 mmHg and required a force in the range of 60-90 N to remove it. The Mediven((R)) ulcer kit exerted the same pressure but required force in the range of 150-190 N to remove it. Two kits (SurePress((R)) Comfort and VenoTrain((R)) Ulcertec) exerted a mean pressure of only 25 mmHg and needed a force in the range of 100-160 N to remove them. Nurses judged the Ulcer X and SurePress kits easiest to apply. Application of the VenoTrain kit was found slightly more difficult. The Mediven kit was judged to be difficult to use. CONCLUSIONS: Comparison of ease of application of compression-stocking kits in normal legs revealed marked differences between them. Only one system exerted a high pressure and was easy to apply. Direct comparison of these compression kits in leg-ulcer patients is required to assess whether our laboratory findings correlate with patient compliance and ulcer healing.
Resumo:
OBJECTIVE: To compare the proportion and rate of healing, pain, and quality of life of low-strength medical compression stockings (MCS) with traditional bandages applied for the treatment of recalcitrant venous leg ulcers. METHODS: A single-center, randomized, open-label study was performed with consecutive patients. Sigvaris prototype MCS providing 15 mm Hg-25 mm Hg at the ankle were compared with multi-layer short-stretch bandages. In both groups, pads were placed above incompetent perforating veins in the ulcer area. The initial static pressure between the dressing-covered ulcer and the pad was 29 mm Hg and 49 mm Hg with MCS and bandages, respectively. Dynamic pressure measurements showed no difference. Compression was maintained day and night and changed every week. The primary endpoint was healing within 90 days. Secondary endpoints were healing within 180 days, time to healing, pain (weekly Likert scales), and monthly quality of life (ChronIc Venous Insufficiency Quality of Life [CIVIQ] questionnaire). RESULTS: Of 74 patients screened, 60 fulfilled the selection criteria and 55 completed the study; 28 in the MCS and 27 in the bandage group. Ulcers were recurrent (48%), long lasting (mean, 27 months), and large (mean, 13 cm2). All but one patient had deep venous reflux and/or incompetent perforating veins in addition to trunk varices. Characteristics of patients and ulcers were evenly distributed (exception: more edema in the MCS group; P = .019). Healing within 90 days was observed in 36% with MCS and in 48% with bandages (P = .350). Healing within 180 days was documented in 50% with MCS and in 67% with bandages (P = .210). Time to healing was identical. Pain scored 44 and 46 initially (on a scale in which 100 referred to maximum and 0 to no pain) and decreased within the first week to 20 and 28 in the MCS and bandage groups, respectively (P < .001 vs .010). Quality of life showed no difference between the treatment groups. In both groups, pain at 90 days had decreased by half, independent of completion of healing. Physical, social, and psychic impairment improved significantly in patients with healed ulcers only. CONCLUSION: Our study illustrates the difficulty of bringing large and long-standing venous ulcers to heal. The effect of compression with MCS was not different from that of compression with bandages. Both treatments alleviated pain promptly. Quality of life was improved only in patients whose ulcers had healed.
Resumo:
OBJECTIVE: The primary aim of the present study was to investigate whether there is a relationship between central hypersensitivity (assessed by pressure pain thresholds of uninjured tissues) and intradiscal pain threshold during discography. The secondary aim was to test the hypothesis that peripheral noxious stimulation dynamically modulates central hypersensitivity. PATIENTS: Twenty-four patients with positive provocation discography were tested for central hypersensitivity by pressure algometry before and after the intervention with assessments of pressure pain detection and tolerance thresholds. Intradiscal pain threshold was assessed by measuring intradiscal pressure at the moment of pain provocation during discography. Correlation analyses between intradiscal pain threshold and pressure algometry were made. For the secondary aim, pressure algometry data before and after discography were compared. RESULTS: Significant correlation with intradiscal pain threshold was found for pressure pain detection threshold at the toe (regression coefficient: 0.03, P = 0.05) and pressure pain tolerance thresholds at the nonpainful point at the back (0.02, P = 0.024). Tolerance threshold at the toe was a significant predictor for intradiscal pain threshold only in multiple linear regression (0.036, P = 0.027). Detection as well as tolerance thresholds significantly decreased after discography at the painful and the nonpainful point at the back, but not at the toe. CONCLUSIONS: Central hypersensitivity may influence intradiscal pain threshold, but with a modest quantitative impact. The diagnostic value of provocation discography is therefore not substantially impaired. Regional, but not generalized central hypersensitivity is dynamically modulated by ongoing peripheral nociceptive input.
Resumo:
Pulse-pressure variation (PPV) due to increased right ventricular afterload and dysfunction may misleadingly suggest volume responsiveness. We aimed to assess prediction of volume responsiveness with PPV in patients with increased pulmonary artery pressure.
Resumo:
Introduction Intracranial pressure monitoring is commonly implemented in patients with neurologic injury and at high risk of developing intracranial hypertension, to detect changes in intracranial pressure in a timely manner. This enables early and potentially life-saving treatment of intracranial hypertension. Case presentation An intraparenchymal pressure probe was placed in the hemisphere contralateral to a large basal ganglia hemorrhage in a 75-year-old Caucasian man who was mechanically ventilated and sedated because of depressed consciousness. Intracranial pressures were continuously recorded and never exceeded 17 mmHg. After sedation had been stopped, our patient showed clinical signs of transtentorial brain herniation, despite apparently normal intracranial pressures (less than 10 mmHg). Computed tomography revealed that the size of the intracerebral hematoma had increased together with significant unilateral brain edema and transtentorial herniation. The contralateral hemisphere where the intraparenchymal pressure probe was placed appeared normal. Our patient underwent emergency decompressive craniotomy and was tracheotomized early, but did not completely recover. Conclusions Intraparenchymal pressure probes placed in the hemisphere contralateral to an intracerebral hematoma may dramatically underestimate intracranial pressure despite apparently normal values, even in the case of transtentorial brain herniation.
Resumo:
We found that pulse pressure variation (PPV) did not predict volume responsiveness in patients with increased pulmonary artery pressure. This study tests the hypothesis that PPV does not predict fluid responsiveness during an endotoxin-induced acute increase in pulmonary artery pressure and right ventricular loading.
Resumo:
Intra-organ and intra-vascular pressures can be used to estimate intra-abdominal pressure. The aim of this prospective, interventional study was to assess the effect of PEEP on the accuracy of pressure estimation at different measurement sites in a model of increased abdominal pressure.
Resumo:
Spontaneous dural arterio-venous fistulas can imperceptibly develop over a long time period before they suddenly develop symptoms like bruit, loss of vision, exophthalmos and conjunctival injection. We present the rare case of an occult, para-infectious, dural arterio-venous fistula which became symptomatic after endoscopic sinus surgery. Conjunctival injection and slight exophthalmos developed due to decompensation of venous drainage probably by intraoperative positioning of the patient, positive pressure ventilation and nasal packing.
Resumo:
The aim of this study was to analyse the cerebral venous outflow in relation to the arterial inflow during a Valsalva manoeuvre (VM). In 19 healthy volunteers (mean age 24.1 +/- 2.6 years), the middle cerebral artery (MCA) and the straight sinus (SRS) were insonated by transcranial Doppler sonography. Simultaneously the arterial blood pressure was recorded using a photoplethysmographic method. Two VM of 10 s length were performed per participant. Tracings of the variables were then transformed to equidistantly re-sampled data. Phases of the VM were analysed regarding the increase of the flow velocities and the latency to the peak. The typical four phases of the VM were also found in the SRS signal. The relative flow velocity (FV) increase was significantly higher in the SRS than in the MCA for all phases, particularly that of phase IV (p < 0.01). Comparison of the time latency of the VM phases of the MCA and SRS only showed a significant difference for phase I (p < 0.01). In particular, there was no significant difference for phase IV (15.8 +/- 0.29 vs. 16.0 +/- 0.28 s). Alterations in venous outflow in phase I are best explained by a cross-sectional change of the lumen of the SRS, while phases II and III are compatible with a Starling resistor. However, the significantly lager venous than the arterial overshoot in phase IV may be explained by the active regulation of the venous tone.
Resumo:
It has been shown that the pressure-to-cornea index (PCI), which estimates the relative effects of intraocular pressure (IOP) and central corneal thickness (CCT), may differentiate between glaucoma and non-glaucoma states. The authors investigated the utility of the pressure-cornea-vascular index (PCVI) in predicting field-progression in patients with normal tension glaucoma (NTG).
Resumo:
To investigate changes in ocular pulse amplitude (OPA) during a short-term increase in intraocular pressure (IOP) and to assess possible influences of biometrical properties of the eye, including central corneal thickness (CCT) and axial length.
Resumo:
The activation of 5-hydroxytryptamine-3 (5-HT-3) receptors in spinal cord can enhance intrinsic spinal mechanisms of central hypersensitivity, possibly leading to exaggerated pain responses. Clinical studies suggest that 5-HT-3 receptor antagonists may have an analgesic effect. This randomized, double-blind, placebo-controlled crossover study tested the hypothesis that the 5-HT-3 receptor antagonist tropisetron attenuates pain and central hypersensitivity in patients with chronic low back pain. Thirty patients with chronic low back pain, 15 of whom were women (aged 53 ± 14 years) and 15 men (aged 48 ± 14 years), were studied. A single intravenous injection of 0.9% saline solution, tropisetron 2mg, and tropisetron 5mg was administrated in 3 different sessions, in a double-blind crossover manner. The main outcome was the visual analogue scale (VAS) score of spontaneous low back pain before, and 15, 30, 60, and 90 minutes after drug administration. Secondary outcomes were nociceptive withdrawal reflexes to single and repeated electrical stimulation, area of reflex receptive fields, pressure pain detection and tolerance thresholds, conditioned pain modulation, and area of clinical pain. The data were analyzed by analysis of variance and panel multiple regressions. All 3 treatments reduced VAS scores. However, there was no statistically significant difference between tropisetron and placebo in VAS scores. Compared to placebo, tropisetron produced a statistically significant increase in pain threshold after single electrical stimulation, but no difference in all other secondary outcomes was found. A single-dose intravenous administration of tropisetron in patients with chronic low back pain had no significant specific effect on intensity of pain and most parameters of central hypersensitivity.
Resumo:
Hypersensitivity of the central nervous system is widely present in pain patients and recognized as one of the determinants of chronic pain and disability. Electronic pressure algometry is often used to explore aspects of central hypersensitivity. We hypothesized that a simple pain provocation test with a clothes peg provides information on pain sensitivity that compares meaningfully to that obtained by a well-established electronic pressure algometer. "Clinically meaningful" was defined as a medium (r = 0.3-0.5) or high (r > 0.5) correlation coefficient according to Cohen's conventions.