106 resultados para Zirconium particles
Resumo:
Neutral particles with long decay paths that decay to many-particle final states represent, from an experimental point of view, a challenge both for the trigger and for the reconstruction capabilities of the ATLAS apparatus. The Hidden Valley scenario serves as an excellent setting for the purpose of exploring the challenges to the trigger posed by long-lived particles.
Resumo:
OBJECTIVES Optical scanners combined with computer-aided design and computer-aided manufacturing (CAD/CAM) technology provide high accuracy in the fabrication of titanium (TIT) and zirconium dioxide (ZrO) bars. The aim of this study was to compare the precision of fit of CAD/CAM TIT bars produced with a photogrammetric and a laser scanner. METHODS Twenty rigid CAD/CAM bars were fabricated on one single edentulous master cast with 6 implants in the positions of the second premolars, canines and central incisors. A photogrammetric scanner (P) provided digitized data for TIT-P (n=5) while a laser scanner (L) was used for TIT-L (n=5). The control groups consisted of soldered gold bars (gold, n=5) and ZrO-P with similar bar design. Median vertical distance between implant and bar platforms from non-tightened implants (one-screw test) was calculated from mesial, buccal and distal scanning electron microscope measurements. RESULTS Vertical microgaps were not significantly different between TIT-P (median 16μm; 95% CI 10-27μm) and TIT-L (25μm; 13-32μm). Gold (49μm; 12-69μm) had higher values than TIT-P (p=0.001) and TIT-L (p=0.008), while ZrO-P (35μm; 17-55μm) exhibited higher values than TIT-P (p=0.023). Misfit values increased in all groups from implant position 23 (3 units) to 15 (10 units), while in gold and TIT-P values decreased from implant 11 toward the most distal implant 15. SIGNIFICANCE CAD/CAM titanium bars showed high precision of fit using photogrammetric and laser scanners. In comparison, the misfit of ZrO bars (CAM/CAM, photogrammetric scanner) and soldered gold bars was statistically higher but values were clinically acceptable.
Resumo:
STATEMENT OF PROBLEM The increasing demand by patients for esthetic and metal-free restorations has driven the development of ceramic restorations with good esthetic and mechanical stability. Recent clinical studies have investigated the use of zirconium dioxide as a core material for complete crowns and computer-aided-design/computer-aided-manufacturing fabricated restorations. PURPOSE The aim of this systematic review was to evaluate the clinical survival rates of porcelain-fused-to-zirconia (PFZ) single crowns on anterior and posterior teeth and to compare them with metal ceramic (MC) crowns. MATERIAL AND METHODS A systematic search was conducted with PubMed and manual research to identify literature written in English that refers to in vivo studies published from January 1, 1950 through July 1, 2011. Clinical trials that evaluated PFZ and MC single crowns on natural teeth were selected for further analysis. Titles and/or abstracts of articles identified through the electronic searches were reviewed and evaluated for appropriateness. In addition, a hand search of relevant dental journals was peformed, and reference lists of culled articles were screened to identify publications. RESULTS The search resulted in a total of 488 initial matches. Nineteen studies with a total of 3621 crowns met the inclusion criteria. The survival rates of PFZ crowns (total 300) ranged from 92.7% to 100% for a follow-up time of 24 to 39 months, whereas those of MC crowns (total 3321) ranged from 70% to 100% for a follow-up time of 12 to 298 months. Studies that reported long-term results were found only for the MC crown group. CONCLUSIONS The scientific clinical data available to compare PFZ and MC crowns are limited. The survival rates may well be influenced by the selection and appropriate use of the veneering ceramic, and, therefore, additional prospective long-term clinical trials are necessary to draw reliable conclusions.
Resumo:
Stochastic models for three-dimensional particles have many applications in applied sciences. Lévy–based particle models are a flexible approach to particle modelling. The structure of the random particles is given by a kernel smoothing of a Lévy basis. The models are easy to simulate but statistical inference procedures have not yet received much attention in the literature. The kernel is not always identifiable and we suggest one approach to remedy this problem. We propose a method to draw inference about the kernel from data often used in local stereology and study the performance of our approach in a simulation study.
Resumo:
Background Conventional cross-sectional imaging with computed tomography and magnetic resonance imaging (MRI) has limited accuracy for lymph node (LN) staging in bladder and prostate cancer patients. Objective To prospectively assess the diagnostic accuracy of combined ultrasmall superparamagnetic particles of iron oxide (USPIO) MRI and diffusion-weighted (DW) MRI in staging of normal-sized pelvic LNs in bladder and/or prostate cancer patients. Design, setting, and participants Examinations with 3-Tesla MRI 24–36 h after administration of USPIO using conventional MRI sequences combined with DW-MRI (USPIO-DW-MRI) were performed in 75 patients with clinically localised bladder and/or prostate cancer staged previously as N0 by conventional cross-sectional imaging. Combined USPIO-DW-MRI findings were analysed by three independent readers and correlated with histopathologic LN findings after extended pelvic LN dissection (PLND) and resection of primary tumours. Outcome measurements and statistical analysis Sensitivity and specificity for LN status of combined USPIO-DW-MRI versus histopathologic findings were evaluated per patient (primary end point) and per pelvic side (secondary end point). Time required for combined USPIO-DW-MRI reading was assessed. Results and limitations At histopathologic analysis, 2993 LNs (median: 39 LNs; range: 17–68 LNs per patient) with 54 LN metastases (1.8%) were found in 20 of 75 (27%) patients. Per-patient sensitivity and specificity for detection of LN metastases by the three readers ranged from 65% to 75% and 93% to 96%, respectively; sensitivity and specificity per pelvic side ranged from 58% to 67% and 94% to 97%, respectively. Median reading time for the combined USPIO-DW-MRI images was 9 min (range: 3–26 min). A potential limitation is the absence of a node-to-node correlation of combined USPIO-DW-MRI and histopathologic analysis. Conclusions Combined USPIO-DW-MRI improves detection of metastases in normal-sized pelvic LNs of bladder and/or prostate cancer patients in a short reading time.
Resumo:
The respiratory tract is an attractive target organ for novel diagnostic and therapeutic applications with nano-sized carriers, but their immune effects and interactions with key resident antigen-presenting cells (APCs) such as dendritic cells (DCs) and alveolar macrophages (AMs) in different anatomical compartments remain poorly understood. Polystyrene particles ranging from 20 nm to 1,000 nm were instilled intranasally in BALB/c mice, and their interactions with APC populations in airways, lung parenchyma, and lung-draining lymph nodes (LDLNs) were examined after 2 and 24 hours by flow cytometry and confocal microscopy. In the main conducting airways and lung parenchyma, DC subpopulations preferentially captured 20-nm particles, compared with 1,000-nm particles that were transported to the LDLNs by migratory CD11blow DCs and that were observed in close proximity to CD3+ T cells. Generally, the uptake of particles increased the expression of CD40 and CD86 in all DC populations, independent of particle size, whereas 20-nm particles induced enhanced antigen presentation to CD4+ T cells in LDLNs in vivo. Despite measurable uptake by DCs, the majority of particles were taken up by AMs, irrespective of size. Confocal microscopy and FACS analysis showed few particles in the main conducting airways, but a homogeneous distribution of all particle sizes was evident in the lung parenchyma, mostly confined to AMs. Particulate size as a key parameter determining uptake and trafficking therefore determines the fate of inhaled particulates, and this may have important consequences in the development of novel carriers for pulmonary diagnostic or therapeutic applications.
Resumo:
We have measured the bidirectional reflectance of spherical micrometer-sized water-ice particles in the visible spectral range over a wide range of incidence and emission angles. The small ice spheres were produced by spraying fine water droplets directly into liquid nitrogen. The resulting mean particle radii are 1.47 + 0.96 - 0.58 μm. Such a material shares many properties with ice in comets and at the surface of icy satellites. Measurements show that the fresh sample material is highly backscattering, contrasting with natural terrestrial snow and frost. The formation of agglomerates of particles during the sample production results in a noticeable variability of the photometric properties of the samples in their initial state. We have also observed significant temporal evolutions of the scattering behavior of the samples, shifting towards more forward scattering within some tens of hours, resulting most likely from sintering processes. All reflectance data are fitted by the Hapke photometric model (1993 and 2002 formulation) with a one/two/three-parameter Henyey-Greenstein phase function and the resulting Hapke parameters are provided. These parameters can be used to compare laboratory results with the observed photometric behaviors of astronomical objects. We show, in particular, that the optical properties of the fresh micrometer-sized ice samples can be used to reproduce the predominant backscattering in the phase curves of Enceladus and Europa.