93 resultados para Real-time qPCR


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wireless Mesh Networks (WMNs) are increasingly deployed to enable thousands of users to share, create, and access live video streaming with different characteristics and content, such as video surveillance and football matches. In this context, there is a need for new mechanisms for assessing the quality level of videos because operators are seeking to control their delivery process and optimize their network resources, while increasing the user’s satisfaction. However, the development of in-service and non-intrusive Quality of Experience assessment schemes for real-time Internet videos with different complexity and motion levels, Group of Picture lengths, and characteristics, remains a significant challenge. To address this issue, this article proposes a non-intrusive parametric real-time video quality estimator, called MultiQoE that correlates wireless networks’ impairments, videos’ characteristics, and users’ perception into a predicted Mean Opinion Score. An instance of MultiQoE was implemented in WMNs and performance evaluation results demonstrate the efficiency and accuracy of MultiQoE in predicting the user’s perception of live video streaming services when compared to subjective, objective, and well-known parametric solutions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The COSMIC-2 mission is a follow-on mission of the Constellation Observing System for Meteorology, Ionosphere, and Climate (COSMIC) with an upgraded payload for improved radio occultation (RO) applications. The objective of this paper is to develop a near-real-time (NRT) orbit determination system, called NRT National Chiao Tung University (NCTU) system, to support COSMIC-2 in atmospheric applications and verify the orbit product of COSMIC. The system is capable of automatic determinations of the NRT GPS clocks and LEO orbit and clock. To assess the NRT (NCTU) system, we use eight days of COSMIC data (March 24-31, 2011), which contain a total of 331 GPS observation sessions and 12 393 RO observable files. The parallel scheduling for independent GPS and LEO estimations and automatic time matching improves the computational efficiency by 64% compared to the sequential scheduling. Orbit difference analyses suggest a 10-cm accuracy for the COSMIC orbits from the NRT (NCTU) system, and it is consistent as the NRT University Corporation for Atmospheric Research (URCA) system. The mean velocity accuracy from the NRT orbits of COSMIC is 0.168 mm/s, corresponding to an error of about 0.051 μrad in the bending angle. The rms differences in the NRT COSMIC clock and in GPS clocks between the NRT (NCTU) and the postprocessing products are 3.742 and 1.427 ns. The GPS clocks determined from a partial ground GPS network [from NRT (NCTU)] and a full one [from NRT (UCAR)] result in mean rms frequency stabilities of 6.1E-12 and 2.7E-12, respectively, corresponding to range fluctuations of 5.5 and 2.4 cm and bending angle errors of 3.75 and 1.66 μrad .

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Personal Health Assistant Project (PHA) is a pilot system implementation sponsored by the Kozani Region Governors’ Association (KRGA) and installed in one of the two major public hospitals of the city of Kozani. PHA is intended to demonstrate how a secure, networked, multipurpose electronic health and food benefits digital signage system can transform common TV sets inside patient homes or hospital rooms into health care media players and facilitate information sharing and improve administrative efficiency among private doctors, public health care providers, informal caregivers, and nutrition program private companies, while placing individual patients firmly in control of the information at hand. This case evaluation of the PHA demonstration is intended to provide critical information to other decision makers considering implementing PHA or related digital signage technology at other institutions and public hospitals around the globe.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The previously described Nc5-specific PCR test for the diagnosis of Neospora caninum infections was used to develop a quantitative PCR assay which allows the determination of infection intensities within different experimental and diagnostic sample groups. The quantitative PCR was performed by using a dual fluorescent hybridization probe system and the LightCycler Instrument for online detection of amplified DNA. This assay was successfully applied for demonstrating the parasite proliferation kinetics in organotypic slice cultures of rat brain which were infected in vitro with N. caninum tachyzoites. This PCR-based method of parasite quantitation with organotypic brain tissue samples can be regarded as a novel ex vivo approach for exploring different aspects of cerebral N. caninum infection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intermolecular electron-transfer reactions have a crucial role in biology, solution chemistry and electrochemistry. The first step of such reactions is the expulsion of the electron to the solvent, whose mechanism is determined by the structure and dynamical response of the latter. Here we visualize the electron transfer to water using ultrafast fluorescence spectroscopy with polychromatic detection from the ultraviolet to the visible region, upon photo-excitation of the so-called charge transfer to solvent states of aqueous iodide. The initial emission is short lived (~60 fs) and it relaxes to a broad distribution of lower-energy charge transfer to solvent states upon rearrangement of the solvent cage. This distribution reflects the inhomogeneous character of the solvent cage around iodide. Electron ejection occurs from the relaxed charge transfer to solvent states with lifetimes of 100–400 fs that increase with decreasing emission energy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ovine foot rot caused by Dichelobacter nodosus is affecting sheep worldwide. The current diagnostic methods are difficult and cumbersome. Here, we present a competitive real-time PCR based on allelic discrimination of the protease genes aprV2 and aprB2. This method allows direct detection and differentiation of virulent and benign D. nodosus from interdigital skin swabs in a single test. Clinically affected sheep harbored high loads of only virulent strains, whereas healthy sheep had lower loads of predominantly benign strains.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermal screening masses related to the conserved vector current are determined for the case that the current carries a non-zero Matsubara frequency, both in a weak-coupling approach and through lattice QCD. We point out that such screening masses are sensitive to the same infrared physics as light-cone real-time rates. In particular, on the perturbative side, the inhomogeneous Schrödinger equation determining screening correlators is shown to have the same general form as the equation implementing LPM resummation for the soft-dilepton and photon production rates from a hot QCD plasma. The static potential appearing in the equation is identical to that whose soft part has been determined up to NLO and on the lattice in the context of jet quenching. Numerical results based on this potential suggest that screening masses overshoot the free results (multiples of 2πT) more strongly than at zero Matsubara frequency. Four-dimensional lattice simulations in two-flavour QCD at temperatures of 250 and 340 MeV confirm the non-static screening masses at the 10% level. Overall our results lend support to studies of jet quenching based on the same potential at T ≳ 250 MeV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We consider a large quantum system with spins 12 whose dynamics is driven entirely by measurements of the total spin of spin pairs. This gives rise to a dissipative coupling to the environment. When one averages over the measurement results, the corresponding real-time path integral does not suffer from a sign problem. Using an efficient cluster algorithm, we study the real-time evolution from an initial antiferromagnetic state of the two-dimensional Heisenberg model, which is driven to a disordered phase, not by a Hamiltonian, but by sporadic measurements or by continuous Lindblad evolution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Bovine paratuberculosis is an incurable chronic granulomatous enteritis caused by Mycobacterium avium subspecies paratuberculosis (MAP). The prevalence of MAP in the Swiss cattle population is hard to estimate, since only a few cases of clinical paratuberculosis are reported to the Swiss Federal Food Safety and Veterinary Office each year.Fecal samples from 1,339 cattle (855 animals from 12 dairy herds, 484 animals from 11 suckling cow herds, all herds with a history of sporadic paratuberculosis) were investigated by culture and real-time polymerase chain reaction (PCR) for shedding of MAP. RESULTS: By culture, MAP was detected in 62 of 445 fecal pools (13.9%), whereas PCR detected MAP in 9 of 445 pools (2.0%). All 186 samples of the 62 culture-positive pools were reanalyzed individually. By culture, MAP was grown from 59 individual samples (31.7%), whereas PCR detected MAP in 12 individual samples (6.5%), all of which came from animals showing symptoms of paratuberculosis during the study. Overall, MAP was detected in 10 out of 12 dairy herds (83.3%) and in 8 out of 11 suckling cow herds (72.7%). CONCLUSIONS: There is a serious clinically inapparent MAP reservoir in the Swiss cattle population. PCR cannot replace culture to identify individual MAP shedders but is suitable to identify MAP-infected herds, given that the amount of MAP shed in feces is increasing in diseased animals or in animals in the phase of transition to clinical disease

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We used real-time LDI to study regional variations in microcirculatory perfusion in healthy candidates to establish a new methodology for global perfusion body mapping that is based on intra-individual perfusion index ratios. Our study included 74 (37 female) healthy volunteers aged between 22 and 30 years (mean 24.49). Imaging was performed using a recent microcirculation-imaging camera (EasyLDI) for different body regions of each volunteer. The perfusion values were reported in Arbitrary Perfusion Units (APU). The relative perfusion indexes for each candidate's body region were then obtained by normalization with the perfusion value of the forehead. Basic parameters such as weight, height, and blood pressure were also measured and analyzed. The highest mean perfusion value was reported in the forehead area (259.21APU). Mean perfusion in the measured parts of the body correlated positively with mean forehead value, while there was no significant correlation between forehead blood perfusion values and room temperature, BMI, systolic blood pressure and diastolic blood pressure (p=0.420, 0.623, 0.488, 0.099, respectively). Analysis of the data showed that perfusion indexes were not significantly different between male and female volunteers except for the ventral upper arm area (p=.001). LDI is a non-invasive, fast technique that opens several avenues for clinical applications. The mean perfusion indexes are useful in clinical practice for monitoring patients before and after surgical interventions. Perfusion values can be predicted for different body parts for patients only by taking the forehead perfusion value and using the perfusion index ratios to obtain expected normative perfusion values.