118 resultados para Reading--Computer-assisted instruction.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we propose a new system that allows reliable acetabular cup placement when the THA is operated in lateral approach. Conceptually it combines the accuracy of computer-generated patient-specific morphology information with an easy-to-use mechanical guide, which effectively uses natural gravity as the angular reference. The former is achieved by using a statistical shape model-based 2D-3D reconstruction technique that can generate a scaled, patient-specific 3D shape model of the pelvis from a single conventional anteroposterior (AP) pelvic X-ray radiograph. The reconstructed 3D shape model facilitates a reliable and accurate co-registration of the mechanical guide with the patient’s anatomy in the operating theater. We validated the accuracy of our system by conducting experiments on placing seven cups to four pelvises with different morphologies. Taking the measurements from an image-free navigation system as the ground truth, our system showed an average accuracy of 2.1 ±0.7 o for inclination and an average accuracy of 1.2 ±1.4 o for anteversion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE : For the facilitation of minimally invasive robotically performed direct cochlea access (DCA) procedure, a surgical planning tool which enables the surgeon to define landmarks for patient-to-image registration, identify the necessary anatomical structures and define a safe DCA trajectory using patient image data (typically computed tomography (CT) or cone beam CT) is required. To this end, a dedicated end-to-end software planning system for the planning of DCA procedures that addresses current deficiencies has been developed. METHODS :    Efficient and robust anatomical segmentation is achieved through the implementation of semiautomatic algorithms; high-accuracy patient-to-image registration is achieved via an automated model-based fiducial detection algorithm and functionality for the interactive definition of a safe drilling trajectory based on case-specific drill positioning uncertainty calculations was developed. RESULTS :    The accuracy and safety of the presented software tool were validated during the conduction of eight DCA procedures performed on cadaver heads. The plan for each ear was completed in less than 20 min, and no damage to vital structures occurred during the procedures. The integrated fiducial detection functionality enabled final positioning accuracies of [Formula: see text] mm. CONCLUSIONS :    Results of this study demonstrated that the proposed software system could aid in the safe planning of a DCA tunnel within an acceptable time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An accurate assessment of the computer skills of students is a pre-requisite for the success of any e-learning interventions. The aim of the present study was to assess objectively the computer literacy and attitudes in a group of Greek post-graduate students, using a task-oriented questionnaire developed and validated in the University of Malmö, Sweden. 50 post-graduate students in the Athens University School of Dentistry in April 2005 took part in the study. A total competence score of 0-49 was calculated. Socio-demographic characteristics were recorded. Attitudes towards computer use were assessed. Descriptive statistics and linear regression modeling were employed for data analysis. Total competence score was normally distributed (Shapiro-Wilk test: W = 0.99, V = 0.40, P = 0.97) and ranged from 5 to 42.5, with a mean of 22.6 (+/-8.4). Multivariate analysis revealed 'gender', 'e-mail ownership' and 'enrollment in non-clinical programs' as significant predictors of computer literacy. Conclusively, computer literacy of Greek post-graduate dental students was increased amongst males, students in non-clinical programs and those with more positive attitudes towards the implementation of computer assisted learning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To assess the literature on accuracy and clinical performance of computer technology applications in surgical implant dentistry. MATERIALS AND METHODS: Electronic and manual literature searches were conducted to collect information about (1) the accuracy and (2) clinical performance of computer-assisted implant systems. Meta-regression analysis was performed for summarizing the accuracy studies. Failure/complication rates were analyzed using random-effects Poisson regression models to obtain summary estimates of 12-month proportions. RESULTS: Twenty-nine different image guidance systems were included. From 2,827 articles, 13 clinical and 19 accuracy studies were included in this systematic review. The meta-analysis of the accuracy (19 clinical and preclinical studies) revealed a total mean error of 0.74 mm (maximum of 4.5 mm) at the entry point in the bone and 0.85 mm at the apex (maximum of 7.1 mm). For the 5 included clinical studies (total of 506 implants) using computer-assisted implant dentistry, the mean failure rate was 3.36% (0% to 8.45%) after an observation period of at least 12 months. In 4.6% of the treated cases, intraoperative complications were reported; these included limited interocclusal distances to perform guided implant placement, limited primary implant stability, or need for additional grafting procedures. CONCLUSION: Differing levels and quantity of evidence were available for computer-assisted implant placement, revealing high implant survival rates after only 12 months of observation in different indications and a reasonable level of accuracy. However, future long-term clinical data are necessary to identify clinical indications and to justify additional radiation doses, effort, and costs associated with computer-assisted implant surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: This systematic review sought to determine the long-term clinical survival rates of single-tooth restorations fabricated with computer-aided design/computer-assisted manufacture (CAD/CAM) technology, as well as the frequency of failures depending on the CAD/CAM system, the type of restoration, the selected material, and the luting agent. MATERIALS AND METHODS: An electronic search from 1985 to 2007 was performed using two databases: Medline/PubMed and Embase. Selected keywords and well-defined inclusion and exclusion criteria guided the search. All articles were first reviewed by title, then by abstract, and subsequently by a full text reading. Data were assessed and extracted by two independent examiners. The pooled results were statistically analyzed and the overall failure rate was calculated by assuming a Poisson-distributed number of events. In addition, reported failures were analyzed by CAD/CAM system, type of restoration, restorative material, and luting agent. RESULTS: From a total of 1,957 single-tooth restorations with a mean exposure time of 7.9 years and 170 failures, the failure rate was 1.75% per year, estimated per 100 restoration years (95% CI: 1.22% to 2.52%). The estimated total survival rate after 5 years of 91.6% (95% CI: 88.2% to 94.1%) was based on random-effects Poisson regression analysis. CONCLUSIONS: Long-term survival rates for CAD/CAM single-tooth Cerec 1, Cerec 2, and Celay restorations appear to be similar to conventional ones. No clinical studies or randomized clinical trials reporting on other CAD/CAM systems currently used in clinical practice and with follow-up reports of 3 or more years were found at the time of the search.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To analyze computer-assisted diagnostics and virtual implant planning and to evaluate the indication for template-guided flapless surgery and immediate loading in the rehabilitation of the edentulous maxilla. MATERIALS AND METHODS: Forty patients with an edentulous maxilla were selected for this study. The three-dimensional analysis and virtual implant planning was performed with the NobelGuide software program (Nobel Biocare, Göteborg, Sweden). Prior to the computer tomography aesthetics and functional aspects were checked clinically. Either a well-fitting denture or an optimized prosthetic setup was used and then converted to a radiographic template. This allowed for a computer-guided analysis of the jaw together with the prosthesis. Accordingly, the best implant position was determined in relation to the bone structure and prospective tooth position. For all jaws, the hypothetical indication for (1) four implants with a bar overdenture and (2) six implants with a simple fixed prosthesis were planned. The planning of the optimized implant position was then analyzed as follows: the number of implants was calculated that could be placed in sufficient quantity of bone. Additional surgical procedures (guided bone regeneration, sinus floor elevation) that would be necessary due the reduced bone quality and quantity were identified. The indication of template-guided, flapless surgery or an immediate loaded protocol was evaluated. RESULTS: Model (a) - bar overdentures: for 28 patients (70%), all four implants could be placed in sufficient bone (total 112 implants). Thus, a full, flapless procedure could be suggested. For six patients (15%), sufficient bone was not available for any of their planned implants. The remaining six patients had exhibited a combination of sufficient or insufficient bone. Model (b) - simple fixed prosthesis: for 12 patients (30%), all six implants could be placed in sufficient bone (total 72 implants). Thus, a full, flapless procedure could be suggested. For seven patients (17%), sufficient bone was not available for any of their planned implants. The remaining 21 patients had exhibited a combination of sufficient or insufficient bone. DISCUSSION: In the maxilla, advanced atrophy is often observed, and implant placement becomes difficult or impossible. Thus, flapless surgery or an immediate loading protocol can be performed just in a selected number of patients. Nevertheless, the use of a computer program for prosthetically driven implant planning is highly efficient and safe. The three-dimensional view of the maxilla allows the determination of the best implant position, the optimization of the implant axis, and the definition of the best surgical and prosthetic solution for the patient. Thus, a protocol that combines a computer-guided technique with conventional surgical procedures becomes a promising option, which needs to be further evaluated and improved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Somatostatin receptor PET tracers such as [68Ga-DOTA,1-Nal3]-octreotide (68Ga-DOTANOC) and [68Ga-DOTA,Tyr3]-octreotate (68Ga-DOTATATE) have shown promising results in patients with neuroendocrine tumors, with a higher lesion detection rate than is achieved with 18F-fluorodihydroxyphenyl-l-alanine PET, somatostatin receptor SPECT, CT, or MR imaging. 68Ga-DOTANOC has high affinity for somatostatin receptor subtypes 2, 3, and 5 (sst2,3,5). It has a wider receptor binding profile than 68Ga-DOTATATE, which is sst2-selective. The wider receptor binding profile might be advantageous for imaging because neuroendocrine tumors express different subtypes of somatostatin receptors. The goal of this study was to prospectively compare 68Ga-DOTANOC and 68Ga-DOTATATE PET/CT in the same patients with gastroenteropancreatic neuroendocrine tumors (GEP-NETs) and to evaluate the clinical impact of 68Ga-DOTANOC PET/CT. Methods: Eighteen patients with biopsy-proven GEP-NETs were evaluated with 68Ga-DOTANOC and 68Ga-DOTATATE using a randomized crossover design. Labeling of DOTANOC and DOTATATE with 68Ga was standardized using a fully automated synthesis device. PET/CT findings were compared with 3-phase CT scans and in some patients with MR imaging, 18F-FDG PET/CT, and histology. Uptake in organs and tumor lesions was quantified and compared by calculation of maximum standardized uptake values (SUVmax) using volume computer-assisted reading. Results: Histology revealed low-grade GEP-NETs (G1) in 4 patients, intermediate grade (G2) in 7, and high grade (G3) in 7. 68Ga-DOTANOC and 68Ga-DOTATATE were false-negative in only 1 of 18 patients. In total, 248 lesions were confirmed by cross-sectional and PET imaging. The lesion-based sensitivity of 68Ga-DOTANOC PET was 93.5%, compared with 85.5% for 68Ga-DOTATATE PET (P = 0.005). The better performance of 68Ga-DOTANOC PET is attributed mainly to the significantly higher detection rate of liver metastases rather than tumor differentiation grade. Multivariate analysis revealed significantly higher SUVmax in G1 tumors than in G3 tumors (P = 0.009). This finding was less pronounced with 68Ga-DOTANOC (P > 0.001). Altogether, 68Ga-DOTANOC changed treatment in 3 of 18 patients (17%). Conclusion: The sst2,3,5-specific radiotracer 68Ga-DOTANOC detected significantly more lesions than the sst2-specific radiotracer 68Ga-DOTATATE in our patients with GEP-NETs. The clinical relevance of this finding has to be proven in larger studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective In order to benefit from the obvious advantages of minimally invasive liver surgery there is a need to develop high precision tools for intraoperative anatomical orientation, navigation and safety control. In a pilot study we adapted a newly developed system for computer-assisted liver surgery (CALS) in terms of accuracy and technical feasibility to the specific requirements of laparoscopy. Here, we present practical aspects related to laparoscopic computer assisted liver surgery (LCALS). Methods Our video relates to a patient presenting with 3 colorectal liver metastases in Seg. II, III and IVa who was selected in an appropriate oncological setting for LCALS using the CAScination system combined with 3D MEVIS reconstruction. After minimal laparoscopic mobilization of the liver, a 4- landmark registration method was applied to enable navigation. Placement of microwave needles was performed using the targeting module of the navigation system and correct needle positioning was confirmed by intraoperative sonography. Ablation of each lesion was carried out by application of microwave energy at 100 Watts for 1 minute. Results To acquire an accurate (less 0.5 cm) registration, 4 registration cycles were necessary. In total, seven minutes were required to accomplish precise registration. Successful ablation with complete response in all treated areas was assessed by intraoperative sonography and confirmed by postoperative CT scan. Conclusions This teaching video demonstrates the theoretical and practical key points of LCALS with a special emphasis on preoperative planning, intraoperative registration and accuracy testing by laparoscopic methodology. In contrast to mere ultrasound-guided ablation of liver lesions, LCALS offers a more dimensional targeting and higher safety control. This is currently also in routine use to treat vanishing lesions and other difficult to target focal lesions within the liver.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The assessment of driving-relevant cognitive functions in older drivers is a difficult challenge as there is no clear-cut dividing line between normal cognition and impaired cognition and not all cognitive functions are equally important for driving. METHODS: To support decision makers, the Bern Cognitive Screening Test (BCST) for older drivers was designed. It is a computer-assisted test battery assessing visuo-spatial attention, executive functions, eye-hand coordination, distance judgment, and speed regulation. Here we compare the performance in BCST with the performance in paper and pencil cognitive screening tests and the performance in the driving simulator testing of 41 safe drivers (without crash history) and 14 unsafe drivers (with crash history). RESULTS: Safe drivers performed better than unsafe drivers in BCST (Mann-Whitney U test: U = 125.5; p = 0.001) and in the driving simulator (Student's t-test: t(44) = -2.64, p = 0.006). No clear group differences were found in paper and pencil screening tests (p > 0.05; ns). BCST was best at identifying older unsafe drivers (sensitivity 86%; specificity 61%) and was also better tolerated than the driving simulator test with fewer dropouts. CONCLUSIONS: BCST is more accurate than paper and pencil screening tests, and better tolerated than driving simulator testing when assessing driving-relevant cognition in older drivers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Virtopsy project, a multi-disciplinary project that involves forensic science, diagnostic imaging, computer science, automation technology, telematics and biomechanics, aims to develop new techniques to improve the outcome of forensic investigations. This paper presents a new approach in the field of minimally invasive virtual autopsy for a versatile robotic system that is able to perform three-dimensional (3D) surface scans as well as post mortem image-guided soft tissue biopsies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this clinical trial was to determine the active tactile sensibility of natural teeth and to obtain a statistical analysis method fitting a psychometric function through the observed data points. On 68 complete dentulous test persons (34 males, 34 females, mean age 45.9 ± 16.1 years), one pair of healthy natural teeth each was tested: n = 24 anterior teeth and n = 44 posterior teeth. The computer-assisted, randomized measurement was done by having the subjects bite on thin copper foils of different thickness (5-200 µm) inserted between the teeth. The threshold of active tactile sensibility was defined by the 50% value of correct answers. Additionally, the gradient of the sensibility curve and the support area (90-10% value) as a description of the shape of the sensibility curve were calculated. For modeling the sensibility curve, symmetric and asymmetric functions were used. The mean sensibility threshold was 14.2 ± 12.1 µm. The older the subject, the higher the tactile threshold (r = 0.42, p = 0.0006). The support area was 41.8 ± 43.3 µm. The higher the 50% threshold, the smaller the gradient of the curve and the larger the support area. The curves showing the active tactile sensibility of natural teeth demonstrate a tendency towards asymmetry, so that the active tactile sensibility of natural teeth can mathematically best be described by using the asymmetric Weibull function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a computationally efficient and biomechanically relevant soft-tissue simulation method for cranio-maxillofacial (CMF) surgery. A template-based facial muscle reconstruction was introduced to minimize the efforts on preparing a patient-specific model. A transversely isotropic mass-tensor model (MTM) was adopted to realize the effect of directional property of facial muscles in reasonable computation time. Additionally, sliding contact around teeth and mucosa was considered for more realistic simulation. Retrospective validation study with postoperative scan of a real patient showed that there were considerable improvements in simulation accuracy by incorporating template-based facial muscle anatomy and sliding contact.