165 resultados para Noninvasive electrocardiography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Early detection is a major goal in the management of malignant melanoma. Besides clinical assessment many noninvasive technologies such as dermoscopy, digital dermoscopy and in vivo laser scanner microscopy are used as additional methods. Herein we tested a system to assess lesional perfusion as a tool for early melanoma detection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We prospectively investigated the potential of positron emission tomography (PET) using the somatostatin receptor (SSTR) analogue ⁶⁸Ga-DOTATATE and 2-deoxy-2[¹⁸F]fluoro-D-glucose (¹⁸F-FDG) in diffuse parenchymal lung disease (DPLD). Twenty-six patients (mean age 68.9 ± 11.0 years) with DPLD were recruited for ⁶⁸Ga-DOTATATE and ¹⁸F-FDG combined PET/high-resolution computed tomography (HRCT) studies. Ten patients had idiopathic pulmonary fibrosis (IPF), 12 patients had nonspecific interstitial pneumonia (NSIP), and 4 patients had other forms of DPLD. Using PET, the pulmonary tracer uptake (maximum standardized uptake value [SUV(max)]) was calculated. The distribution of PET tracer was compared to the distribution of lung parenchymal changes on HRCT. All patients demonstrated increased pulmonary PET signal with ⁶⁸Ga-DOTATATE and ¹⁸F-FDG. The distribution of parenchymal uptake was similar, with both tracers corresponding to the distribution of HRCT changes. The mean SUV(max) was 2.2 ± 0.7 for ⁶⁸Ga-DOTATATE and 2.8 ± 1.0 (t-test, p  =  .018) for ¹⁸F-FDG. The mean ⁶⁸Ga-DOTATATE SUV(max) in IPF patients was 2.5 ± 0.9, whereas it was 2.0 ± 0.7 (p  =  .235) in NSIP patients. The correlation between ⁶⁸Ga-DOTATATE SUV(max) and gas transfer (transfer factor of the lung for carbon monoxide [TLCO]) was r  =  -.34 (p  =  .127) and r  =  -.49 (p  =  .028) between ¹⁸F-FDG SUV(max) and TLCO. We provide noninvasive in vivo evidence in humans showing that SSTRs may be detected in the lungs of patients with DPLD in a similar distribution to sites of increased uptake of ¹⁸F-FDG on PET.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Magnetic resonance spectroscopy enables insight into the chemical composition of spinal cord tissue. However, spinal cord magnetic resonance spectroscopy has rarely been applied in clinical work due to technical challenges, including strong susceptibility changes in the region and the small cord diameter, which distort the lineshape and limit the attainable signal to noise ratio. Hence, extensive signal averaging is required, which increases the likelihood of static magnetic field changes caused by subject motion (respiration, swallowing), cord motion, and scanner-induced frequency drift. To avoid incoherent signal averaging, it would be ideal to perform frequency alignment of individual free induction decays before averaging. Unfortunately, this is not possible due to the low signal to noise ratio of the metabolite peaks. In this article, frequency alignment of individual free induction decays is demonstrated to improve spectral quality by using the high signal to noise ratio water peak from non-water-suppressed proton magnetic resonance spectroscopy via the metabolite cycling technique. Electrocardiography (ECG)-triggered point resolved spectroscopy (PRESS) localization was used for data acquisition with metabolite cycling or water suppression for comparison. A significant improvement in the signal to noise ratio and decrease of the Cramér Rao lower bounds of all metabolites is attained by using metabolite cycling together with frequency alignment, as compared to water-suppressed spectra, in 13 healthy volunteers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Auditory hallucinations comprise a critical domain of psychopathology in schizophrenia. Repetitive transcranial magnetic stimulation (TMS) has shown promise as an intervention with both positive and negative reports. The aim of this study was to test resting-brain perfusion before treatment as a possible biological marker of response to repetitive TMS. Twenty-four medicated patients underwent resting-brain perfusion magnetic resonance imaging with arterial spin labeling (ASL) before 10 days of repetitive TMS treatment. Response was defined as a reduction in the hallucination change scale of at least 50%. Responders (n=9) were robustly differentiated from nonresponders (n=15) to repetitive TMS by the higher regional cerebral blood flow (CBF) in the left superior temporal gyrus (STG) (P<0.05, corrected) before treatment. Resting-brain perfusion in the left STG predicted the response to repetitive TMS in this study sample, suggesting this parameter as a possible bio-marker of response in patients with schizophrenia and auditory hallucinations. Being noninvasive and relatively easy to use, resting perfusion measurement before treatment might be a clinically relevant way to identify possible responders and nonresponders to repetitive TMS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Resonance frequency analysis (RFA) is a noninvasive technique for the quantitative assessment of implant stability. Information on the implant stability quotient (ISQ) of transmucosally inserted implants is limited. Purpose: The aim of this investigation was to compare the ISQ of conventionally inserted implants by raising a muco-periostal flap with implants inserted using a flapless procedure. Materials and Methods: Forty elderly patients with complete edentulous maxilla were consecutively admitted for treatment with implant-supported prostheses. A computer tomography was obtained for the computer-assisted implant planning. One hundred ten implants were placed conventionally in 23 patients (flap-group) and 85 implants in 17 patients by means of the flapless method (flapless-group) using a stereolithographic template. RFA measurements were performed after implant placement (baseline) and after a healing time of 12 weeks (reentry). Results: All implants exhibited clinically and radiographically successful osseointegration. Bone level did not change significantly neither for genders nor type of surgical protocol. Mean ISQ values of the flapless-group were significantly higher at baseline (p < .001) and at reentry (p < .001) compared with the flap-group. The ISQ values were significantly lower at reentry compared with baseline for the flap-group (p = .028) but not for the flapless-group. This group showed a moderate, but insignificant increase. RFA measurements of males resulted in ISQ values that were thoroughly higher as compared with females at both time-points in both groups. Correlation between RFA and bone level was not found. Conclusions: The flapless procedure showed favorable conditions with regard to implant stability and crestal bone level. Some changes of the ISQ values that represent primary (mechanical) and secondary (bone remodeling) implant stability were observed in slight favor of the flapless method and male patients. In properly planned and well-selected cases, the minimal invasive transmucosal technique using a drill-guide is a safe procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the utility of nasotracheal tubes in postoperative oxygen supplementation in dogs following corrective surgery for brachycephalic syndrome. DESIGN: Retrospective study 2003-2007. SETTING: University teaching hospital. ANIMALS: Thirty-six client-owned dogs that underwent corrective surgery for brachycephalic syndrome. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Medical records were reviewed for animals that underwent surgical interventions for brachycephalic syndrome including palatoplasty, ventriculectomy, and rhinoplasty. Data collected included signalment, presenting complaints, analgesic and surgical interventions, type of supplemental oxygen therapy, complications and mortality occurring during hospitalization. A nasotracheal tube (NTT) was placed in 20 dogs at the end of surgery; 16 dogs received other forms of oxygen supplementation (8) or no oxygen supplementation (8) during recovery. The total number of postoperative complications was similar in both groups (8/20 dogs with NTTs and 7/16 in those without NTTs). However, respiratory distress was observed in 5 dogs without NTTs but was not observed in any dog while an NTT was in place. One dog in each group died postoperatively. CONCLUSION: Placement of an NTT was found to be easy and may offer benefit in dogs with brachycephalic syndrome as a noninvasive means of delivering oxygen. The use of NTT may minimize severe postoperative morbidity, in particular by reducing postoperative respiratory distress.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Diagnosing arrhythmias by conventional Holter-ECG can be cumbersome because of artifacts, skin irritation and poor P-waves. In contrast, esophageal electrocardiography (eECG) is promising due to the anatomic relationship of the esophagus to the atria and its favorable bioelectric properties. Methods used: In an ambulant setting, we recorded eECGs from 10 volunteers with a novel, highly-miniaturized eECG recorder that is worn discretely behind the ear (1.5×1.8×5cm, 22grams). The device continuously records two eECG leads during 3 days with 500Hz sampling frequency and 24-bit resolution. Results: Mean ± SD recording time was 21.7±19.6 hours (max. 60 hours). Test persons were not limited in daily activities (e.g. eating, speaking) and only complained mild discomfort during probe insertion, which subsided later on. During 99.8% of time, the recorder acquired signals appropriate for further analysis. In unfiltered data, QRS complexes and P-waves were identifiable during >98% of time. P waves had higher amplitudes as compared to surface ECG (0.71 ± 0.42mV vs. 0.16 ± 0.03mV, p = 0.004). No complications occurred. Conclusion: Ambulatory eECG recording is safe, well tolerated and promising due to excellent P-wave detection, overcoming some limitations of conventional Holter ECG.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Legg-Calvé-Perthes disease (LCPD) often results in a deformity that can be considered as a complex form of femoroacetabular impingement (FAI). Improved preoperative characterization of the FAI problem based on a noninvasive three-dimensional computer analysis may help to plan the appropriate operative treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Noninvasive stress testing might guide the use of aspirin and statins for primary prevention of coronary heart disease, but it is unclear if such a strategy would be cost effective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite Duplex ultrasonography being a noninvasive, easily repeatable, readily available and economical tool, this examination and its normal ranges are rarely described in Moyamoya disease (MMD).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to test the hypothesis that ear oximetry immediately after the release of a sustained Valsalva maneuver accurately detects patent foramen ovale (PFO). One hundred sixty-five scuba divers underwent transesophageal echocardiography (TEE; reference method) for PFO assessment. Ear oximetry of the right earlobe was performed in a different room within a time frame of 2 hours before or after TEE. The subject and the oximetry operator were unaware of the results of TEE. Oxygen saturation (SO(2)) measurements were obtained at baseline and during the release phase of 4 Valsalva maneuvers within 10 minutes, and the average SO(2) change (SO(2) at baseline minus SO(2) at Valsalva release) was determined as the primary study end point. One hundred seventeen divers had no PFO, and 48 (29%) had PFO by TEE (mean age 39 ± 8 years). The average SO(2) change was 0.79 ± 1.13% (i.e., a slight absolute SO(2) decrease in response to the Valsalva maneuver) in the group without PFO and 1.67 ± 1.19% in the PFO group (p <0.0001). Using receiver-operating characteristic curve analysis, a PFO as defined by TEE could be detected at a threshold of a Valsalva-induced decrease in SO(2) of ≥0.825 percentage points in comparison to baseline (sensitivity 0.756, specificity 0.706, area under the receiver-operating characteristic curve 0.763, p <0.0001, negative predictive value 0.882). In conclusion, the entirely noninvasive method of ear oximetry in response to repetitive Valsalva maneuvers is accurate and useful as a screening method for the detection of a PFO, as shown in this study of divers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The arterial switch operation (ASO) is currently the treatment of choice in neonates with transposition of the great arteries (TGA). The outcome in childhood is encouraging but only limited data for long-term outcome into adulthood exist. METHODS AND RESULTS: We studied 145 adult patients (age>16, median 25years) with ASO followed at our institution. Three patients died in adulthood (mortality 2.4/1000-patient-years). Most patients were asymptomatic and had normal left ventricular function. Coronary lesions requiring interventions were rare (3 patients) and in most patients related to previous surgery. There were no acute coronary syndromes. Aortic root dilatation was frequent (56% patients) but rarely significant (>45mm in 3 patients, maximal-diameter 49mm) and appeared not to be progressive. There were no acute aortic events and no patient required elective aortic root surgery. Progressive neo-aortic-valve dysfunction was not observed in our cohort and only 1 patient required neo-aortic-valve replacement. Many patients (42.1%), however, had significant residual lesions or required reintervention in adulthood. Right ventricular outflow tract lesions or dysfunction of the neo-pulmonary-valve were frequent and 8 patients (6%) required neo-pulmonary-valve replacement. Cardiac interventions during childhood (OR 3.0, 95% CI 1.7-5.4, P<0.0001) were strong predictors of outcome (cardiac intervention/significant residual lesion/death) in adulthood. CONCLUSIONS: Adult patients with previous ASO remain free of acute coronary or aortic complications and have low mortality. However, a large proportion of patients require re-interventions or present with significant right sided lesions. Life-long cardiac follow-up is, therefore, warranted. Periodic noninvasive surveillance for coronary complications appears to be safe in adult ASO patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Time-of-flight (ToF) and phase contrast (PC) magnetic resonance angiographies (MRAs) are noninvasive applications to depict the cerebral arteries. Both approaches can image the cerebral vasculature without the administration of intravenous contrast. Therefore, it is used in routine clinical evaluation of cerebrovascular diseases, e.g., aneurysm and arteriovenous malformations. However, subtle microvascular disease usually cannot be resolved with standard, clinical-field-strength MRA. The purpose of this study was to compare the ability of ToF and PC MRA to visualize the cerebral arteries at increasing field strengths.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this article, we will link neuroimaging, data analysis, and intervention methods in an important psychiatric condition: auditory verbal hallucinations (AVH). The clinical and phenomenological background as well as neurophysiological findings will be covered and discussed with respect to noninvasive brain stimulation. Additionally, methods of noninvasive brain stimulation will be presented as ways to intervene with AVH. Finally, preliminary conclusions and possible future perspectives will be proposed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE:Conventional platinum coils cause imaging artifacts that reduce imaging quality and therefore impair imaging interpretation on intraprocedural or noninvasive follow-up imaging. The purpose of this study was to evaluate imaging characteristics and artifact production of polymeric coils compared with standard platinum coils in vitro and in vivo.MATERIALS AND METHODS:Polymeric coils and standard platinum coils were evaluated in vitro with the use of 2 identical silicon aneurysm models coiled with a packing attenuation of 20% each. DSA, flat panel CT, CT, and MR imaging were performed. In vivo evaluation of imaging characteristics of polymeric coils was performed in experimentally created rabbit carotid bifurcation aneurysms. DSA, CT/CTA, and MR imaging were performed after endovascular treatment of the aneurysms. Images were evaluated regarding visibility of individual coils, coil mass, artifact production, and visibility of residual flow within the aneurysm.RESULTS:Overall, in vitro and in vivo imaging showed relevantly reduced artifact production of polymeric coils in all imaging modalities compared with standard platinum coils. Image quality of CT and MR imaging was improved with the use of polymeric coils, which permitted enhanced depiction of individual coil loops and residual aneurysm lumen as well as the peri-aneurysmal area. Remarkably, CT images demonstrated considerably improved image quality with only minor artifacts compared with standard coils. On DSA, polymeric coils showed transparency and allowed visualization of superimposed vessel structures.CONCLUSIONS:This initial experimental study showed improved imaging quality with the use of polymeric coils compared with standard platinum coils in all imaging modalities. This might be advantageous for improved intraprocedural imaging for the detection of complications and posttreatment noninvasive follow-up imaging.