217 resultados para NONMATCHING IMPLANT
Resumo:
OBJECTIVES: This experiment was performed to evaluate clinically and histologically the effect of mechanical therapy with or without antiseptic therapy on peri-implant mucositis lesions in nine cynomolgus monkeys. MATERIAL AND METHODS: Two ITI titanium implants were inserted into each side of the mandibles. After 90 days of plaque control and soft tissue healing, a baseline clinical examination was completed. Peri-implant lesions were induced by placing silk ligatures and allowing plaque to accumulate for 6 weeks. The clinical examination was then repeated, and the monkeys were randomly assigned to three treatment groups: group A, mechanical cleansing only; group B, mechanical cleansing and local irrigation with 0.12% chlorhexidine (CHX) and application of 0.2% CHX gel; and group C, control, no treatment. The implants in treatment groups A and B were treated and maintained according to the assigned treatment for two additional months. At the end of the maintenance period, a final clinical examination was performed and the animals were sacrificed for biopsies. RESULTS: The mean probing depths (PD) values at mucositis were: 3.5, 3.7, and 3.4 mm, and clinical attachment level (CAL) = 3.8, 4.1, and 3.9 mm for treatment groups A, B and C, respectively. The corresponding values after treatment were: PD = 1.7, 2.1, and 2.5 mm, and CAL=2.6, 2.6, and 3.1 mm. ANOVA of mean changes (Delta) in PD and CAL after treatment showed no statistical difference between the treatment groups. Comparison of the mean changes in PD and CAL after treatment yielded statistical differences between the control and treatment groups P < 0.01. According to the t-test, no statistical difference was found between treatment groups A and B for the PD reduction but there was a significant difference for the CAL change, P < 0.03. Group A had significantly more recession and less CAL gain than group B. Non-parametric tests yielded no significant differences in modified plaque index (mPlI) and gingival index (GI) after treatment between both treatment groups. Frequencies and percent distributions of the mPlI and GI scores changed considerably for both treatment groups when compared with the changes in the control group after treatment. With regard to the histological evaluation, no statistical differences existed between the treatments for any linear measurement. The proportion of inflammation found in the mucosal tissues of the control implants was greater than the one found for both treatment groups, P < 0.01. More importantly, both treatment groups showed a similar low proportion of inflammation after 2 months of treatment. CONCLUSIONS: Within the limitations of this experiment, and considering the supportive plaque control rendered, it can be concluded that for pockets of 3-4 mm: (1) mechanical therapy alone or combined with CHX results in the clinical resolution of peri-implant mucositis lesions, (2) histologically, both treatments result in minimal inflammation compatible with health, and (3) the mechanical effect alone is sufficient to achieve clinical and histologic resolution of mucositis lesions.
Resumo:
Clinical aspects of a simple treatment concept with fixed prostheses in the edentulous jaw are described. Fixed implant-supported reconstructions in the edentulous jaw require multiple implants, are technically complex, aesthetically demanding and metal-ceramic solutions are expensive. Specific surgical techniques to enhance the hard and soft tissue conditions become often necessary. Thus the bar-supported overdenture may be preferred, because problems with aesthetics and alveolar ridge deficiencies can be solved more easily and the number of implants is reduced. Both, the "All-on-Four" technique and the "Procera implant bridge" are simple type of fixed prostheses, comparable to overdentures or complete dentures with regard to design and technology. They present a cost-effective alternative, with predictable aesthetics and optimum passive fit.
Resumo:
Replacement of maxillary front teeth with a fixed, implant supported partial denture with a high laugh line is a demanding procedure. For an optimal esthetic result, no deficiency of bone or soft tissue is acceptable. Submerged implant healing has often been recommended for better predictability in esthetically demanding situations. This case report shows the rehabilitation with a fixed implant supported reconstruction in the upper front and a single implant supported crown in the premolar region. Teeth had to be extracted because of apical lesions, periodontal the gingiva. The technique of delayed, submerged implant placement in the region of 11, 21 and 22 was applied and in the region of 15 a transmucosal implant healing. With a fixed, implant supported partial denture the mucosa in the upper front was conditioned. Ten months after implantation the definitive screwed, fixed partial denture on SPI ELEMENT implants was successfully integrated. In the region 15 a single crown transversally screwed was fixed on a SPI ONE TIME implant. Radiographic data two years after implantation showed a well established periimplant crestal bone level. No prosthetic complications had occurred since the insertion of the reconstruction twelve months ago.
Resumo:
The new Swiss implant system SPI became available three years ago and is used in combination with fixed and removable prosthetic reconstructions. In a pilot study the clinical procedures were evaluated and data of prosthetic complications of maintenance service were collected. 25 patients participated in the study with a total of 79 SPI implants during the time period from 2003-2004. 37 implants were located in the maxilla and 42 implants in the mandible. Two implants failed during the healing period, but no loaded implant was lost. Thus, the survival rate was 97.5% (77/79). 44 implants supported a fixed prosthesis, including nine single crowns and 33 implants were used in combination with removable partial denture. Four implants were used with ball anchor retention, 29 with bar support. The ELEMENT implant with the low implant shoulder allows very good esthetics. Prosthetic complications and maintenance service during the first year of function was comparable with other implant systems. Since the design of the abutment screws, healing caps and screwdriver was changed, the system has become easier in its application.
Resumo:
The purpose of this practical manual is to describe and illustrate each step of the basic surgical procedures involved in the placement of implants in qualified patients. To that end, each procedure is briefly but lucidly described; carefully illustrated in a series of drawings of the techniques and instrumentation used; and reinforced through clinical photographs, including radiographic and postoperative follow-up views. In addition to the basic implant surgical principles, evidence-based indications and procedures for guided bone regeneration in apical fenestration and crestal dehiscence defects, and for simultaneous sinus floor elevation via the lateral window and osteotome techniques are featured.
A systematic review of the 5-year survival and complication rates of implant-supported single crowns
Resumo:
OBJECTIVES: The objective of this systematic review was to assess the 5-year survival of implant-supported single crowns (SCs) and to describe the incidence of biological and technical complications. METHODS: An electronic MEDLINE search complemented by manual searching was conducted to identify prospective and retrospective cohort studies on SCs with a mean follow-up time of at least 5 years. Failure and complication rates were analyzed using random-effects Poisson's regression models to obtain summary estimates of 5-year proportions. RESULTS: Twenty-six studies from an initial yield of 3601 titles were finally selected and data were extracted. In a meta-analysis of these studies, survival of implants supporting SCs was 96.8% [95% confidence interval (CI): 95.9-97.6%] after 5 years. The survival rate of SCs supported by implants was 94.5% (95% CI: 92.5-95.9%) after 5 years of function. The survival rate of metal-ceramic crowns, 95.4% (95% CI: 93.6-96.7%), was significantly (P=0.005) higher than the survival rate, 91.2% (95% CI: 86.8-94.2%), of all-ceramic crowns. Peri-implantitis and soft tissue complications occurred adjacent to 9.7% of the SCs and 6.3% of the implants had bone loss exceeding 2 mm over the 5-year observation period. The cumulative incidence of implant fractures after 5 years was 0.14%. After 5 years, the cumulative incidence of screw or abutment loosening was 12.7% and 0.35% for screw or abutment fracture. For supra-structure-related complications, the cumulative incidence of ceramic or veneer fractures was 4.5%. CONCLUSION: It can be concluded that after an observation period of 5 years, high survival rates for implants and implant-supported SCs can be expected. However, biological and particularly technical complications are frequent.
Resumo:
BACKGROUND: Conventionally, endosseous dental implants have required 3 to 6 months of uninterrupted healing based on observations for dental implants that were characterized by a relatively smooth machined surface. Many studies have since demonstrated that implants with a roughened surface resulted in greater bone apposition, earlier bone contact, and a stronger bond between the implant and the bone, suggesting that implants with roughened surfaces could be loaded earlier than 3 to 6 months. Formal clinical studies confirmed that implants with rough surfaces can have abutments placed and be loaded occlusally as early as 6 weeks postplacement. The purpose of this prospective, human clinical investigation was to evaluate a large number of implants with a specific rough surface (sand-blasted acid-etched [SLA]) placed in everyday practice under routine private-practice conditions. METHODS: A prospective, multicenter, human clinical observational study was initiated with the goal of recruiting a minimum of 500 patients and 800 implants. The implants were to be placed and restored in predominantly private-practice settings around the world. Ninety-two practitioners in 16 countries agreed to participate, and 86 followed the study design. Patients had to be in good health, have sufficient bone to encase the implant, and agree to return for recall appointments. Exclusion criteria included heavy smoking (>10 cigarettes a day) and bone augmentation procedures at the implant site. All implants were two-piece (an abutment was to be placed after 6 weeks of healing) and were characterized by the presence of a transmucosal polished collar. Each implant had an SLA surface. All implants were positioned using a non-submerged (single-stage) surgical technique. Survival and success rates were calculated by life-table analyses. RESULTS: A total of 706 patients were enrolled and 1,406 implants were placed. In the final analyses, 590 patients with 990 implants (70.4% of those enrolled) met all inclusion criteria, including placement of an abutment and provisional restoration within 63 days of surgical placement. The majority of implants were 10 and 12 mm long (78.7%) and were placed in type II and III bone (87%). Seventy-three percent of the implants were placed in the mandible, and 27% were placed in the maxilla. The cumulative survival rate was 99.56% at 3 years and 99.26% at 5 years. The overall success rate was 99.12% at 3 years and 97.38% after 5 years. CONCLUSIONS: Under private-practice conditions, implants with an SLA surface could be placed and restored predictably within 6 to 8 weeks. Data from this prospective, multicenter, human observational study reinforced the results of more formal clinical studies and demonstrated that implants with the SLA surface can be restored in patients in approximately half of the time of conventional healing periods.
Resumo:
Osteogenic agents, such as bone morphogenetic protein-2 (BMP-2), can stimulate the degradation as well as the formation of bone. Hence, they could impair the osteoconductivity of functionalized implant surfaces. We assessed the effects of BMP-2 and its mode of delivery on the osteoconductivity of dental implants with either a naked titanium surface or a calcium-phosphate-coated one. The naked titanium surface bore adsorbed BMP-2, whilst the coated one bore incorporated, adsorbed, or incorporated and adsorbed BMP-2. The implants were inserted into the maxillae of adult miniature pigs. The volume of bone deposited within a defined "osteoconductive" (peri-implant) space, and bone coverage of the implant surface delimiting this space, were estimated morphometrically 1-3 weeks later. After 3 weeks, the volume of bone deposited within the osteoconductive space was highest for coated and uncoated implants bearing no BMP-2, followed by coated implants bearing incorporated BMP-2; it was lowest for coated implants bearing only adsorbed BMP-2. Bone-interface coverage was highest for coated implants bearing no BMP-2, followed by coated implants bearing either incorporated, or incorporated and adsorbed BMP-2; it was lowest for uncoated implants bearing adsorbed BMP-2. Hence, the osteoconductivity of implant surfaces can be significantly modulated by BMP-2 and its mode of delivery.
Resumo:
OBJECTIVES: To compare the clinical outcomes of standard, cylindrical, screw-shaped to novel tapered, transmucosal (Straumann Dental implants immediately placed into extraction sockets. Material and methods: In this randomized-controlled clinical trial, outcomes were evaluated over a 3-year observation period. This report deals with the need for bone augmentation, healing events, implant stability and patient-centred outcomes up to 3 months only. Nine centres contributed a total of 208 immediate implant placements. All surgical and post-surgical procedures and the evaluation parameters were discussed with representatives of all centres during a calibration meeting. Following careful luxation of the designated tooth, allocation of the devices was randomly performed by a central study registrar. The allocated SLA titanium implant was installed at the bottom or in the palatal wall of the extraction socket until primary stability was reached. If the extraction socket was >or=1 mm larger than the implant, guided bone regeneration was performed simultaneously (Bio Oss and BioGide. The flaps were then sutured. During non-submerged transmucosal healing, everything was done to prevent infection. At surgery, the need for augmentation and the degree of wound closure was verified. Implant stability was assessed clinically and by means of resonance frequency analysis (RFA) at surgery and after 3 months. Wound healing was evaluated after 1, 2, 6 and 12 weeks post-operatively. RESULTS: The demographic data did not show any differences between the patients receiving either standard cylindrical or tapered implants. All implants yielded uneventful healing with 15% wound dehiscences after 1 week. After 2 weeks, 93%, after 6 weeks 96%, and after 12 weeks 100% of the flaps were closed. Ninety percent of both implant designs required bone augmentation. Immediately after implantation, RFA values were 55.8 and 56.7 and at 3 months 59.4 and 61.1 for cylindrical and tapered implants, respectively. Patient-centred outcomes did not differ between the two implant designs. However, a clear preference of the surgeon's perception for the appropriateness of the novel-tapered implant was evident. CONCLUSIONS: This RCT has demonstrated that tapered or standard cylindrical implants yielded clinically equivalent short-term outcomes after immediate implant placement into the extraction socket.
Resumo:
OBJECTIVES: To evaluate whether or not preparation of the implant site with osteotomes instead of drilling may improve peri-implant bone density and/or osseointegration, and whether or not this further improves the predictability of immediate loading of SLA implants. MATERIAL AND METHODS: The second, third, and fourth premolars were extracted in both sides of the mandible in six dogs, and after at least 3 months four SLA implants were inserted into each side of the jaw. In three animals, the implant sites were prepared by means of osteotomes, while standard stepwise drilling was used in the remaining animals. In each side of the jaw, two non-adjacent implants were restored with single crowns 4 days after installation, while the remaining two implants were left without crowns to serve as non-loaded controls. After 2, 4, or 12 weeks of loading, specimens including the implants and surrounding tissues were obtained and processed for histologic analysis of undecalcified sections. RESULTS: All implants placed with osteotomes were lost (five before delivery of the crowns and the rest during the first week after loading). None of the conventionally inserted implants, however, was lost, and histomorphometrical analysis revealed similar soft- and hard peri-implant tissue characteristics at immediately loaded and non-loaded implants at all observation times. Average bone-to-implant contact was 59-72% at immediately loaded implants vs. 60-63% at non-loaded ones. CONCLUSION: Preparation of the implant site by means of osteotomes had a deleterious effect on osseointegration, while immediate loading of single, free-standing, SLA implants following a conventional surgical protocol did not jeopardize their osseointegration.
Resumo:
PURPOSE: The objective of the present experiment was to study the morphogenesis of the mucosal attachment to implants made of c.p. titanium. MATERIAL AND METHODS: All mandibular premolars were extracted in 20 Labrador dogs. After a healing period of 3 months, four implants (ITI Dental Implant System) were placed in the right and left sides of the mandible. A non-submerged implant installation technique was used and the mucosal tissues were secured to the conical marginal portion of the implants with interrupted sutures. The sutures were removed after 2 weeks and a plaque control program including daily cleaning of the remaining teeth and the implants was initiated. The animals were sacrificed and biopsies were obtained at various intervals to provide healing periods extending from Day 0 (2 h) to 12 weeks. The mandibles were removed and placed in the fixative. The implant sites were dissected using a diamond saw and processed for histological analysis. RESULTS: Large numbers of neutrophils infiltrated and degraded the coagulum that occupied the compartment between the mucosa and the implant during the initial phase of healing. At 2 weeks after surgery, fibroblasts were the dominating cell population in the connective tissue interface but at 4 weeks the density of fibroblasts had decreased. Furthermore, the first signs of epithelial proliferation were observed in specimens representing 1-2 weeks of healing and a mature barrier epithelium occurred after 6-8 weeks of healing. The collagen fibers of the mucosa were organized after 4-6 weeks of healing. CONCLUSION: It is suggested that the soft-tissue attachment to implants placed using a non-submerged installation procedure is properly established after several weeks following surgery.
Resumo:
Speech coding might have an impact on music perception of cochlear implant users. This questionnaire study compares the musical activities and perception of postlingually deafened cochlear implant users with three different coding strategies (CIS, ACE, SPEAK) using the Munich Music Questionnaire. Overall, the self-reported perception of music of CIS, SPEAK, and ACE users did not differ by very much.
Resumo:
Indications for the most frequently used imaging modalities in implant dentistry are proposed based on clinical need and biologic risk for the patient. To calculate the biologic risk, the authors carried out dose measurements. They demonstrated that the risk from a periapical radiograph is 20% of that from a panoramic radiograph. A panoramic radiograph and a series of 4 conventional tomographs of a single-tooth gap in the molar region carry 5% and 13% of the risk from computed tomography of the maxilla, respectively. Panoramic radiography is considered the standard radiographic examination for treatment planning of implant patients, because it imparts a low dose while giving the best radiographic survey. Periapical radiographs are used to elucidate details or to complete the findings obtained from the panoramic radiograph. Other radiographic methods, such as conventional film tomography or computed tomography, are applied only in special circumstances, film tomography being preferred for smaller regions of interest and computed tomography being justified for the complete maxilla or mandible when methods for dose reduction are followed. During follow-up, intraoral radiography is considered the standard radiographic examination, particularly for implants in the anterior region of the maxilla or for scientific studies. In patients requiring more than 5 periapical images, panoramic radiography is preferred.