95 resultados para Müller, Josef FerdinandMüller, Josef FerdinandJosef FerdinandMüller


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systemic concentrations of interleukin-6 (IL-6) are elevated in patients with liver cirrhosis, and impaired hepatic uptake of IL-6 was suggested to contribute to higher levels in these patients. To test this hypothesis IL-6 was measured in portal venous serum (PVS), hepatic venous serum (HVS) and systemic venous serum (SVS) of 41 patients with liver cirrhosis and four patients with normal liver function. IL-6 was higher in PVS than HVS of all blood donors and about 43% of portal vein derived IL-6 was extracted by the healthy liver, and 6.3% by the cirrhotic liver demonstrating markedly impaired removal of IL-6 by the latter. Whereas in patients with CHILD-PUGH stage A IL-6 in HVS was almost 25% lower than in PVS, in patients with CHILD-PUGH stage C IL-6 was similarly abundant in the two blood compartments. Ascites is a common complication in cirrhotic patients and was associated with higher IL-6 levels in all blood compartments without significant differences in hepatic excretion. Hepatic venous pressure gradient did not correlate with the degree of hepatic IL-6 removal excluding hepatic shunting as the principal cause of impaired IL-6 uptake. Furthermore, patients with alcoholic liver cirrhosis had higher IL-6 in all blood compartments than patients with cryptogenic liver cirrhosis. Aetiology of liver cirrhosis did not affect hepatic removal rate indicating higher IL-6 synthesis in patients with alcoholic liver cirrhosis. In summary, the current data provide evidence that impaired hepatic removal of IL-6 is explained by hepatic shunting and liver dysfunction in patients with liver cirrhosis partly explaining higher systemic levels.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We screened 735 HIV-infected patients in Switzerland with unexplained alanine aminotransferase elevation for hepatitis E virus (HEV) immunoglobulin G. Although HEV seroprevalence in this population is low (2.6%), HEV RNA can persist in patients with low CD4 cell counts. Findings suggest chronic HEV infection should be considered as a cause of persistent alanine aminotransferase elevation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Diagnosing arrhythmias by conventional Holter-ECG can be cumbersome because of artifacts, skin irritation and poor P-waves. In contrast, esophageal electrocardiography (eECG) is promising due to the anatomic relationship of the esophagus to the atria and its favorable bioelectric properties. Methods used: In an ambulant setting, we recorded eECGs from 10 volunteers with a novel, highly-miniaturized eECG recorder that is worn discretely behind the ear (1.5×1.8×5cm, 22grams). The device continuously records two eECG leads during 3 days with 500Hz sampling frequency and 24-bit resolution. Results: Mean ± SD recording time was 21.7±19.6 hours (max. 60 hours). Test persons were not limited in daily activities (e.g. eating, speaking) and only complained mild discomfort during probe insertion, which subsided later on. During 99.8% of time, the recorder acquired signals appropriate for further analysis. In unfiltered data, QRS complexes and P-waves were identifiable during >98% of time. P waves had higher amplitudes as compared to surface ECG (0.71 ± 0.42mV vs. 0.16 ± 0.03mV, p = 0.004). No complications occurred. Conclusion: Ambulatory eECG recording is safe, well tolerated and promising due to excellent P-wave detection, overcoming some limitations of conventional Holter ECG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two commercially available electrode catheters are examined for their suitability in esophageal long-term ECG recordings. Both, electrical sensing characteristics as well as clinical acceptance were investigated in a clinical study including inpatients with cardiovascular diseases. In total, 31 esophageal ECG were obtained in 36 patients. Results showed that esophageal electrodes were well tolerated by the patients. Hemispherical electrodes with higher diameter required more insertion attempts and were associated with increased failure rates as compared to cylindrical electrodes. In contrast, the higher surface area of hemispherical electrodes resulted in significantly higher signal-to-noise ratio. Contact impedance was equal for both electrode types, but esophageal electrodes had lower impedance if compared with skin electrodes.