75 resultados para Laboratory study


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to improve cage systems for maintaining adult honey bee (Apis mellifera L.) workers under in vitro laboratory conditions. To achieve this goal, we experimentally evaluated the impact of different cages, developed by scientists of the international research network COLOSS (Prevention of honey bee COlony LOSSes), on the physiology and survival of honey bees. We identified three cages that promoted good survival of honey bees. The bees from cages that exhibited greater survival had relatively lower titers of deformed wing virus, suggesting that deformed wing virus is a significant marker reflecting stress level and health status of the host. We also determined that a leak- and drip-proof feeder was an integral part of a cage system and a feeder modified from a 20-ml plastic syringe displayed the best result in providing steady food supply to bees. Finally, we also demonstrated that the addition of protein to the bees' diet could significantly increase the level ofvitellogenin gene expression and improve bees' survival. This international collaborative study represents a critical step toward improvement of cage designs and feeding regimes for honey bee laboratory experiments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conventional risk assessments for crop protection chemicals compare the potential for causing toxicity (hazard identification) to anticipated exposure. New regulatory approaches have been proposed that would exclude exposure assessment and just focus on hazard identification based on endocrine disruption. This review comprises a critical analysis of hazard, focusing on the relative sensitivity of endocrine and non-endocrine endpoints, using a class of crop protection chemicals, the azole fungicides. These were selected because they are widely used on important crops (e.g. grains) and thereby can contact target and non-target plants and enter the food chain of humans and wildlife. Inhibition of lanosterol 14α-demethylase (CYP51) mediates the antifungal effect. Inhibition of other CYPs, such as aromatase (CYP19), can lead to numerous toxicological effects, which are also evident from high dose human exposures to therapeutic azoles. Because of its widespread use and substantial database, epoxiconazole was selected as a representative azole fungicide. Our critical analysis concluded that anticipated human exposure to epoxiconazole would yield a margin of safety of at least three orders of magnitude for reproductive effects observed in laboratory rodent studies that are postulated to be endocrine-driven (i.e. fetal resorptions). The most sensitive ecological species is the aquatic plant Lemna (duckweed), for which the margin of safety is less protective than for human health. For humans and wildlife, endocrine disruption is not the most sensitive endpoint. It is concluded that conventional risk assessment, considering anticipated exposure levels, will be protective of both human and ecological health. Although the toxic mechanisms of other azole compounds may be similar, large differences in potency will require a case-by-case risk assessment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Treatment of chronic myeloid leukemia (CML) with tyrosine kinase inhibitors has advanced to a stage where many patients achieve very low or undetectable levels of disease. Remarkably, some of these patients remain in sustained remission when treatment is withdrawn, suggesting that they may be at least operationally cured of their disease. Accurate definition of deep molecular responses (MRs) is therefore increasingly important for optimal patient management and comparison of independent data sets. We previously published proposals for broad standardized definitions of MR at different levels of sensitivity. Here we present detailed laboratory recommendations, developed as part of the European Treatment and Outcome Study for CML (EUTOS), to enable testing laboratories to score MR in a reproducible manner for CML patients expressing the most common BCR-ABL1 variants.Leukemia advance online publication, 27 February 2015; doi:10.1038/leu.2015.29.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND After cardiac surgery with cardiopulmonary bypass (CPB), acquired coagulopathy often leads to post-CPB bleeding. Though multifactorial in origin, this coagulopathy is often aggravated by deficient fibrinogen levels. OBJECTIVE To assess whether laboratory and thrombelastometric testing on CPB can predict plasma fibrinogen immediately after CPB weaning. PATIENTS / METHODS This prospective study in 110 patients undergoing major cardiovascular surgery at risk of post-CPB bleeding compares fibrinogen level (Clauss method) and function (fibrin-specific thrombelastometry) in order to study the predictability of their course early after termination of CPB. Linear regression analysis and receiver operating characteristics were used to determine correlations and predictive accuracy. RESULTS Quantitative estimation of post-CPB Clauss fibrinogen from on-CPB fibrinogen was feasible with small bias (+0.19 g/l), but with poor precision and a percentage of error >30%. A clinically useful alternative approach was developed by using on-CPB A10 to predict a Clauss fibrinogen range of interest instead of a discrete level. An on-CPB A10 ≤10 mm identified patients with a post-CPB Clauss fibrinogen of ≤1.5 g/l with a sensitivity of 0.99 and a positive predictive value of 0.60; it also identified those without a post-CPB Clauss fibrinogen <2.0 g/l with a specificity of 0.83. CONCLUSIONS When measured on CPB prior to weaning, a FIBTEM A10 ≤10 mm is an early alert for post-CPB fibrinogen levels below or within the substitution range (1.5-2.0 g/l) recommended in case of post-CPB coagulopathic bleeding. This helps to minimize the delay to data-based hemostatic management after weaning from CPB.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Spreading the PSF over a quite large amount of pixels is an increasingly used observing technique in order to reach extremely precise photometry, such as in the case of exoplanets searching and characterization via transits observations. A PSF top-hat profile helps to minimize the errors contribution due to the uncertainty on the knowledge of the detector flat field. This work has been carried out during the recent design study in the framework of the ESA small mission CHEOPS. Because of lack of perfect flat-fielding information, in the CHEOPS optics it is required to spread the light of a source into a well defined angular area, in a manner as uniform as possible. Furthermore this should be accomplished still retaining the features of a true focal plane onto the detector. In this way, for instance, the angular displacement on the focal plane is fully retained and in case of several stars in a field these look as separated as their distance is larger than the spreading size. An obvious way is to apply a defocus, while the presence of an intermediate pupil plane in the Back End Optics makes attractive to introduce here an optical device that is able to spread the light in a well defined manner, still retaining the direction of the chief ray hitting it. This can be accomplished through an holographic diffuser or through a lenslet array. Both techniques implement the concept of segmenting the pupil into several sub-zones where light is spread to a well defined angle. We present experimental results on how to deliver such PSF profile by mean of holographic diffuser and lenslet array. Both the devices are located in an intermediate pupil plane of a properly scaled laboratory setup mimicking the CHEOPS optical design configuration. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Access to hepatitis B viral load (VL) testing is poor in sub-Saharan Africa (SSA) due toeconomic and logistical reasons.Objectives: To demonstrate the feasibility of testing dried blood spots (DBS) for hepatitis B virus (HBV)VL in a laboratory in Lusaka, Zambia, and to compare HBV VLs between DBS and plasma samples.Study design: Paired plasma and DBS samples from HIV-HBV co-infected Zambian adults were analyzedfor HBV VL using the COBAS AmpliPrep/COBAS TaqMan HBV test (Version 2.0) and for HBV genotypeby direct sequencing. We used Bland-Altman analysis to compare VLs between sample types and bygenotype. Logistic regression analysis was conducted to assess the probability of an undetectable DBSresult by plasma VL.Results: Among 68 participants, median age was 34 years, 61.8% were men, and median plasma HBV VLwas 3.98 log IU/ml (interquartile range, 2.04–5.95). Among sequenced viruses, 28 were genotype A1 and27 were genotype E. Bland–Altman plots suggested strong agreement between DBS and plasma VLs. DBSVLs were on average 1.59 log IU/ml lower than plasma with 95% limits of agreement of −2.40 to −0.83 logIU/ml. At a plasma VL ≥2,000 IU/ml, the probability of an undetectable DBS result was 1.8% (95% CI:0.5–6.6). At plasma VL ≥20,000 IU/ml this probability reduced to 0.2% (95% CI: 0.03–1.7).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stable isotope ratios of nitrate preserved in deep ice cores are expected to provide unique and valuable information regarding paleoatmospheric processes. However, due to the post-depositional loss of nitrate in snow, this information may be erased or significantly modified by physical or photochemical processes before preservation in ice. We investigated the role of solar UV photolysis in the post-depositional modification of nitrate mass and stable isotoperatios at Dome C, Antarctica, during the austral summer of 2011/2012. Two 30 cm snow pits were filled with homogenized drifted snow from the vicinity of the base. One of these pits was covered with a plexiglass plate that transmits solar UV radiation, while the other was covered with a different plexiglass plate having a low UV transmittance. Samples were then collected from each pit at a 2–5 cm depth resolution and a 10-day frequency. At the end of the season, acomparable nitrate mass loss was observed in both pits for the top-level samples (0–7 cm) attributed to mixing with the surrounding snow. After excluding samples impacted by the mixing process, we derived an average apparent nitrogen isotopic fractionation (15" app/of role in driving the isotopic fractionation of nitrate in snow.We have estimated a purely photolytic nitrogen isotopic fractionation (15"photo) of -55.8 12.0 ‰ from the difference in the derived apparent isotopic ractionations of the two experimental fields, as both pits were exposed to similar physical processes except exposure to solar UV. This value is in close agreement with the 15" photo value of -47.9 6.8 ‰ derived in a laboratory experiment simulated for Dome C conditions (Berhanu et al., 2014). We have also observed an insensitivity of 15" with depth in the snowpack under the given experimental setup. This is due to the uniform attenuation of incoming solar UV by snow, as 15" is strongly dependent on the spectral distribution of the incoming light flux. Together with earlier work, the results presented here represent a strong body of evidence that solar UV photolysis is the most relevant post-depositional process modifying the stable isotope ratios of snow nitrate at low-accumulation sites, where many deep ice cores are drilled. Nevertheless, modeling the loss of nitrate in snow is still required before a robust interpretation of ice core records can be provided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sublimation, the direct transition from solid to gas phase, is a process responsible for shaping and changing the reflectance properties of many Solar System surfaces. In this study, we have characterized the evolution of the structure/texture and of the visible and near-infrared (VIS–NIR) spectral reflectance of surfaces made of water ice mixed with analogues of complex extraterrestrial organic matter, named tholins, under low temperature (<-70° C) and pressure (10-⁵mbar) conditions. The experiments were carried out in the SCITEAS simulation setup recently built as part of the Laboratory for Outflow Studies of Sublimating Materials (LOSSy) at the University of Bern (Pommerol, A. et al. [2015a]. Planet. Space Sci. 109–110, 106–122). As the water ice sublimated, we observed in situ the formation of a sublimation lag deposit made of a water-free porous (>90% porosity) network of organic filaments on top of the ice. The temporal evolution of the tholins and water ice spectral features (reflectance at the absorption bands wavelengths, red slope, from 0.40 to 1.90lm) are analyzed throughout the sublimation of the samples. We studied how different mixtures of tholins with water (0.1 wt.% tholins as coating or inclusions within the water particles), and different ice particle sizes (4.5 ± 2.5 or 67 ± 31lm) influence the morphological and spectral evolutions of the samples. The sublimation of the ice below the mantle produces a gas flow responsible for the ejection of mm to cm-sized fragments of the deposit in outbursts-like events. The results show remarkable differences between these samples in term of mantle structure, speed of mantle building, rates and surface area of mantle ejections. These data provide useful references for interpreting remote-sensing observations of icy Solar System surfaces, in particular the activity of comet nuclei where sublimation of organic-rich ices and deposition of organic-dust particles likely play a major role. Consequently, the data presented here could be of high interest for the interpretation of Rosetta, and also New Horizons, observations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To evaluate whether magnetic resonance imaging (MRI) is effective as computed tomography (CT) in determining morphologic and functional pulmonary changes in patients with cystic fibrosis (CF) in association with multiple clinical parameters. MATERIALS AND METHODS Institutional review board approval and patient written informed consent were obtained. In this prospective study, 30 patients with CF (17 men and 13 women; mean (SD) age, 30.2 (9.2) years; range, 19-52 years) were included. Chest CT was acquired by unenhanced low-dose technique for clinical purposes. Lung MRI (1.5 T) comprised T2- and T1-weighted sequences before and after the application of 0.1-mmol·kg gadobutrol, also considering lung perfusion imaging. All CT and MR images were visually evaluated by using 2 different scoring systems: the modified Helbich and the Eichinger scores. Signal intensity of the peribronchial walls and detected mucus on T2-weighted images as well as signal enhancement of the peribronchial walls on contrast-enhanced T1-weighted sequences were additionally assessed on MRI. For the clinical evaluation, the pulmonary exacerbation rate, laboratory, and pulmonary functional parameters were determined. RESULTS The overall modified Helbich CT score had a mean (SD) of 15.3 (4.8) (range, 3-21) and median of 16.0 (interquartile range [IQR], 6.3). The overall modified Helbich MR score showed slightly, not significantly, lower values (Wilcoxon rank sum test and Student t test; P > 0.05): mean (SD) of 14.3 (4.7) (range, 3-20) and median of 15.0 (IQR, 7.3). Without assessment of perfusion, the overall Eichinger score resulted in the following values for CT vs MR examinations: mean (SD), 20.3 (7.2) (range, 4-31); and median, 21.0 (IQR, 9.5) vs mean (SD), 19.5 (7.1) (range, 4-33); and median, 20.0 (IQR, 9.0). All differences between CT and MR examinations were not significant (Wilcoxon rank sum tests and Student t tests; P > 0.05). In general, the correlations of the CT scores (overall and different imaging parameters) to the clinical parameters were slightly higher compared to the MRI scores. However, if all additional MRI parameters were integrated into the scoring systems, the correlations reached the values of the CT scores. The overall image quality was significantly higher for the CT examinations compared to the MRI sequences. CONCLUSIONS One major diagnostic benefit of lung MRI in CF is the possible acquisition of several different morphologic and functional imaging features without the use of any radiation exposure. Lung MRI shows reliable associations with CT and clinical parameters, which suggests its implementation in CF for routine diagnosis, which would be particularly important in follow-up imaging over the long term.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION This paper focuses exclusively on experimental models with ultra high dilutions (i.e. beyond 10(-23)) that have been submitted to replication scrutiny. It updates previous surveys, considers suggestions made by the research community and compares the state of replication in 1994 with that in 2015. METHODS Following literature research, biochemical, immunological, botanical, cell biological and zoological studies on ultra high dilutions (potencies) were included. Reports were grouped into initial studies, laboratory-internal, multicentre and external replications. Repetition could yield either comparable, or zero, or opposite results. The null-hypothesis was that test and control groups would not be distinguishable (zero effect). RESULTS A total of 126 studies were found. From these, 28 were initial studies. When all 98 replicative studies were considered, 70.4% (i.e. 69) reported a result comparable to that of the initial study, 20.4% (20) zero effect and 9.2% (9) an opposite result. Both for the studies until 1994 and the studies 1995-2015 the null-hypothesis (dominance of zero results) should be rejected. Furthermore, the odds of finding a comparable result are generally higher than of finding an opposite result. Although this is true for all three types of replication studies, the fraction of comparable studies diminishes from laboratory-internal (total 82.9%) to multicentre (total 75%) to external (total 48.3%), while the fraction of opposite results was 4.9%, 10.7% and 13.8%. Furthermore, it became obvious that the probability of an external replication producing comparable results is bigger for models that had already been further scrutinized by the initial researchers. CONCLUSIONS We found 28 experimental models which underwent replication. In total, 24 models were replicated with comparable results, 12 models with zero effect, and 6 models with opposite results. Five models were externally reproduced with comparable results. We encourage further replications of studies in order to learn more about the model systems used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cardiac allograft vasculopathy (CAV) is a form of accelerated atherosclerosis, which represents the leading cause of late morbidity and mortality after heart transplantation. The recent bioresorbable vascular scaffold (BVS) technology represents a potential novel therapeutic tool, in the context of CAV, by allowing transient scaffolding and concomitant vessel healing. Eligible subjects will be treated by using the Absorb Everolimus-Eluting BVS (Abbott Vascular, Santa Clara, CA, USA), and evaluated at pre-determined time points, up to 3 years since the index procedure. Both clinical and imaging data will be collected in dedicated case report forms (CRF). All imaging data will be analyzed in an independent core laboratory. The primary aim of the study is to evaluate the angiographic performance at 1 year of second-generation Absorb BVS, in heart transplant recipients affected by CAV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: The biased interpretation of ambiguous social situations is considered a maintaining factor of Social Anxiety Disorder (SAD). Studies on the modification of interpretation bias have shown promising results in laboratory settings. The present study aims at pilot-testing an Internet-based training that targets interpretation and judgmental bias. METHOD: Thirty-nine individuals meeting diagnostic criteria for SAD participated in an 8-week, unguided program. Participants were presented with ambiguous social situations, were asked to choose between neutral, positive, and negative interpretations, and were required to evaluate costs of potential negative outcomes. Participants received elaborate automated feedback on their interpretations and judgments. RESULTS: There was a pre-to-post-reduction of the targeted cognitive processing biases (d = 0.57-0.77) and of social anxiety symptoms (d = 0.87). Furthermore, results showed changes in depression and general psychopathology (d = 0.47-0.75). Decreases in cognitive biases and symptom changes did not correlate. The results held stable accounting for drop-outs (26%) and over a 6-week follow-up period. Forty-five percent of the completer sample showed clinical significant change and almost half of the participants (48%) no longer met diagnostic criteria for SAD. LIMITATIONS: As the study lacks a control group, results lend only preliminary support to the efficacy of the intervention. Furthermore, the mechanism of change remained unclear. CONCLUSION: First results promise a beneficial effect of the program for SAD patients. The treatment proved to be feasible and acceptable. Future research should evaluate the intervention in a randomized-controlled setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Radioactivity induced by a 15-MeV proton beam extracted into air was studied at the beam transport line of the 18-MeV cyclotron at the Bern University Hospital (Inselspital). The produced radioactivity was calculated and measured by means of proportional counters located at the main exhaust of the laboratory. These devices were designed for precise assessment of air contamination for radiation protection purposes. The main produced isotopes were 11C, 13N and 14O. Both measurements and calculations correspond to two different irradiation conditions. In the former, protons were allowed to travel for their full range in air. In the latter, they were stopped at the distance of 1.5 m by a beam dump. Radioactivity was measured continuously in the exhausted air starting from 2 min after the end of irradiation. For this reason, the short-lived 14O isotope gave a negligible contribution to the measured activity. Good agreement was found between the measurements and the calculations within the estimated uncertainties. Currents in the range of 120–370 nA were extracted in air for 10–30 s producing activities of 9–22 MBq of 11C and 13N. The total activities for 11C and 13N per beam current and irradiation time for the former and the latter irradiation conditions were measured to be (3.60 ± 0.48) × 10−3 MBq (nA s)−1 and (2.89 ± 0.37) × 10−3 MBq (nA s)−1, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Sutureless aortic valve replacement (AVR) offers an alternative to standard AVR in aortic stenosis. This prospective, single-arm study aimed to demonstrate safety and effectiveness of a bovine pericardial sutureless aortic valve at 1 year. METHODS From February 2010 to September 2013, 658 patients (mean age 78.3 ± 5.6 years; 40.0% octogenarian; 64.4% female; mean Society of Thoracic Surgeons score 7.2 ± 7.4) underwent sutureless AVR in 25 European centers. Concomitant cardiac procedures were performed in 29.5% and minimally invasive cardiac surgery in 33.3%. RESULTS One-year site-reported event rates were 8.1% for all-cause mortality, 4.5% for cardiac mortality, 3.0% for stroke, 1.9% for valve-related reoperation, 1.4% for endocarditis, and 0.6% for major paravalvular leak. No valve thrombosis, migration, or structural valve deterioration occurred. New York Heart Association class improved at least 1 level in 77.5% and remained stable (70.4% New York Heart Association class I or II at 1 year). Mean effective orifice area was 1.5 ± 0.4 cm(2); pressure gradient was 9.2 ± 5.0 mm Hg. Left ventricular mass decreased from 138.5 g/m(2) before surgery to 115.3 g/m(2) at 1 year (P < .001). Echocardiographic core laboratory findings confirmed that paravalvular leak was rare and remained stable during follow-up. CONCLUSIONS The Perceval sutureless valve resulted in low 1-year event rates in intermediate-risk patients undergoing AVR. New York Heart Association class improved in more than three-quarters of patients and remained stable. These data support the safety and efficacy to 1 year of the Perceval sutureless valve in this intermediate-risk population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Overtreatment of asymptomatic bacteriuria (ASB) is widespread and may result in antibiotic side-effects, excess costs to the healthcare system, and may potentially trigger antimicrobial resistance. According to international management guidelines, ASB is not an indication for antibiotic treatment (with few exceptions). AIM To determine reasons for using antibiotics to treat ASB in the absence of a treatment indication. METHODS A qualitative study was conducted at a tertiary care hospital in Switzerland during 2011. We interviewed 21 internal medicine residents and attending physicians selected by purposive sampling, using a semi-structured questionnaire. Responses were analysed in an inductive thematic content approach using dedicated software (MAXQDA(®)). FINDINGS In the 21 interviews, the following thematic rationales for antibiotic overtreatment of ASB were reported (in order of reporting frequency): (i) treating laboratory findings without taking the clinical picture into account (N = 17); (ii) psychological factors such as anxiety, overcautiousness, or anticipated positive impact on patient outcomes (N = 13); (iii) external pressors such as institutional culture, peer pressure, patient expectation, and excessive workload that interferes with proper decision-making (N = 9); (iv) difficulty with interpreting clinical signs and symptoms (N = 8). CONCLUSION In this qualitative study we identified both physician-centred factors (e.g. overcautiousness) and external pressors (e.g. excessive workload) as motivators for prescribing unnecessary antibiotics. Also, we interpreted the frequently cited practice of treating asymptomatic patients based on laboratory findings alone as lack of awareness of evidence-based best practices.