93 resultados para Hafter, Evelyn
Resumo:
OBJECTIVE: This study investigated the current supply of complementary and alternative medicine (CAM) in Swiss primary care. Information was collected on physicians' qualifications in CAM, frequency of patients' demand for CAM, physicians' supply and temporal resources for CAM as well as physicians' referrals to CAM. MATERIAL AND METHODS: 750 (500 German-speaking and 250 French-speaking) randomly selected Swiss female and male primary care physicians were asked to complete a questionnaire (response rate 50.4%). Sociodemographic data on professional training, place of residence, and sex were used to calculate a weighting factor to correct the responders' data in the analysis accordingly. RESULTS: 14.2% of the physicians were qualified in at least one CAM discipline. Around 30% (95% confidence interval 25.4-34.6%) of the physicians were asked for CAM by their patients more than once a week. Homeopathy and phytotherapy were the most frequently offered therapies, followed by traditional Chinese medicine (TCM)/acupuncture. 62.5% (57.6-67.4%) of the physicians refer their patients to CAM. Most patients were referred to TCM/acupuncture. Of the 37.2% (32.6-42.4%) of the physicians who do not refer their patients to CAM, around 40% (35.1-44.9%) offer it themselves. CONCLUSION: About three quarters of the physicians offer CAM themselves or refer their patients to CAM treatments. CAM is very important in primary medical care in Switzerland. Clear regulations for CAM are required in order to ensure a high quality in care.
Resumo:
BACKGROUND: Little is known about the population's exposure to radio frequency electromagnetic fields (RF-EMF) in industrialized countries. OBJECTIVES: To examine levels of exposure and the importance of different RF-EMF sources and settings in a sample of volunteers living in a Swiss city. METHODS: RF-EMF exposure of 166 volunteers from Basel, Switzerland, was measured with personal exposure meters (exposimeters). Participants carried an exposimeter for 1 week (two separate weeks in 32 participants) and completed an activity diary. Mean values were calculated using the robust regression on order statistics (ROS) method. RESULTS: Mean weekly exposure to all RF-EMF sources was 0.13 mW/m(2) (0.22 V/m) (range of individual means 0.014-0.881 mW/m(2)). Exposure was mainly due to mobile phone base stations (32.0%), mobile phone handsets (29.1%) and digital enhanced cordless telecommunications (DECT) phones (22.7%). Persons owning a DECT phone (total mean 0.15 mW/m(2)) or mobile phone (0.14 mW/m(2)) were exposed more than those not owning a DECT or mobile phone (0.10 mW/m(2)). Mean values were highest in trains (1.16 mW/m(2)), airports (0.74 mW/m(2)) and tramways or buses (0.36 mW/m(2)), and higher during daytime (0.16 mW/m(2)) than nighttime (0.08 mW/m(2)). The Spearman correlation coefficient between mean exposure in the first and second week was 0.61. CONCLUSIONS: Exposure to RF-EMF varied considerably between persons and locations but was fairly consistent within persons. Mobile phone handsets, mobile phone base stations and cordless phones were important sources of exposure in urban Switzerland.
Resumo:
AIMS: Lesion length remains a predictor of target lesion revascularisation and results of long lesion stenting remain poor. Sirolimus-eluting stents have been shown to perform better than paclitaxel eluting stents in long lesions. In this substudy of the LEADERS trial, we compared the performance of biolimus biodegradable polymer (BES) and sirolimus permanent polymer stents (SES) in long lesions. METHODS AND RESULTS: A total of 1,707 'all-comer' patients were randomly allocated to treatment with BES and SES. A stratified analysis of angiographic and clinical outcomes at nine months and one year, respectively was performed for vessels with lesion length <20 mm versus >20 mm (as measured by quantitative angiography).Of 1,707 patients, 592 BES patients with 831 lesions and 619 SES patients with 876 lesions had only short lesions treated. One hundred and fifty-three BES patients with 166 lesions and 151 SES patients with 162 lesions had long lesions. There were no significant differences in baseline clinical characteristics, except for higher number of patients with long lesions presenting with acute myocardial infarction in both stent groups. Long lesions tended to have lower MLD and greater percent diameter stenosis at baseline than short lesions. Late loss was greater for long lesions than short lesions. There was no statistically significant difference in late loss between BES and SES stents (0.32+/-0.69 vs 0.24+/-0.57, p=0.59). Binary in-segment restenosis was present in 23.2% versus 13.1% of long lesions treated with BES and SES, respectively (p=0.042). In patients with long lesions, the overall MACE rate was similar for BES and SES (17% vs 14.6%; p=0.62). There was a trend towards higher overall TLR rate with BES (12.4 % vs 6.0%; HR=2.06; p=0.07) and clinically driven TLR (10.5% vs 5.3%: HR 1.94; p=0.13). Rates of definite stent thrombosis were 3.3% in the long lesion group and 1.3-1.7 % in the short lesion group. CONCLUSIONS: BES and SES appear similar with respect to MACE in long lesions in this "all-comer" patient population. However, long lesions tended to have a higher rate of binary in-segment restenosis and TLR following BES than SES treatment.
Resumo:
Radio frequency electromagnetic fields (RF-EMF) in our daily life are caused by numerous sources such as fixed site transmitters (e.g. mobile phone base stations) or indoor devices (e.g. cordless phones). The objective of this study was to develop a prediction model which can be used to predict mean RF-EMF exposure from different sources for a large study population in epidemiological research. We collected personal RF-EMF exposure measurements of 166 volunteers from Basel, Switzerland, by means of portable exposure meters, which were carried during one week. For a validation study we repeated exposure measurements of 31 study participants 21 weeks after the measurements of the first week on average. These second measurements were not used for the model development. We used two data sources as exposure predictors: 1) a questionnaire on potentially exposure relevant characteristics and behaviors and 2) modeled RF-EMF from fixed site transmitters (mobile phone base stations, broadcast transmitters) at the participants' place of residence using a geospatial propagation model. Relevant exposure predictors, which were identified by means of multiple regression analysis, were the modeled RF-EMF at the participants' home from the propagation model, housing characteristics, ownership of communication devices (wireless LAN, mobile and cordless phones) and behavioral aspects such as amount of time spent in public transports. The proportion of variance explained (R2) by the final model was 0.52. The analysis of the agreement between calculated and measured RF-EMF showed a sensitivity of 0.56 and a specificity of 0.95 (cut-off: 90th percentile). In the validation study, the sensitivity and specificity of the model were 0.67 and 0.96, respectively. We could demonstrate that it is feasible to model personal RF-EMF exposure. Most importantly, our validation study suggests that the model can be used to assess average exposure over several months.
Resumo:
Lipoproteins are a heterogeneous population of blood plasma particles composed of apolipoproteins and lipids. Lipoproteins transport exogenous and endogenous triglycerides and cholesterol from sites of absorption and formation to sites of storage and usage. Three major classes of lipoproteins are distinguished according to their density: high-density (HDL), low-density (LDL) and very low-density lipoproteins (VLDL). While HDLs contain mainly apolipoproteins of lower molecular weight, the two other classes contain apolipoprotein B and apolipoprotein (a) together with triglycerides and cholesterol. HDL concentrations were found to be inversely related to coronary heart disease and LDL/VLDL concentrations directly related. Although many studies have been published in this area, few have concentrated on the exact protein composition of lipoprotein particles. Lipoproteins were separated by density gradient ultracentrifugation into different subclasses. Native gel electrophoresis revealed different gel migration behaviour of the particles, with less dense particles having higher apparent hydrodynamic radii than denser particles. Apolipoprotein composition profiles were measured by matrix-assisted laser desorption/ionization-mass spectrometry on a macromizer instrument, equipped with the recently introduced cryodetector technology, and revealed differences in apolipoprotein composition between HDL subclasses. By combining these profiles with protein identifications from native and denaturing polyacrylamide gels by liquid chromatography-tandem mass spectrometry, we characterized comprehensively the exact protein composition of different lipoprotein particles. We concluded that the differential display of protein weight information acquired by macromizer mass spectrometry is an excellent tool for revealing structural variations of different lipoprotein particles, and hence the foundation is laid for the screening of cardiovascular disease risk factors associated with lipoproteins.
Resumo:
BACKGROUND The long-term results after second generation everolimus eluting bioresorbable vascular scaffold (Absorb BVS) placement in small vessels are unknown. Therefore, we investigated the impact of vessel size on long-term outcomes, after Absorb BVS implantation. METHODS In ABSORB Cohort B Trial, out of the total study population (101 patients), 45 patients were assigned to undergo 6-month and 2-year angiographic follow-up (Cohort B1) and 56 patients to have angiographic follow-up at 1-year (Cohort B2). The pre-reference vessel diameter (RVD) was <2.5 mm (small-vessel group) in 41 patients (41 lesions) and ≥2.5 mm (large-vessel group) in 60 patients (61 lesions). Outcomes were compared according to pre-RVD. RESULTS At 2-year angiographic follow-up no differences in late lumen loss (0.29±0.16 mm vs 0.25±0.22 mm, p=0.4391), and in-segment binary restenosis (5.3% vs 5.3% p=1.0000) were demonstrated between groups. In the small-vessel group, intravascular ultrasound analysis showed a significant increase in vessel area (12.25±3.47 mm(2) vs 13.09±3.38 mm(2) p=0.0015), scaffold area (5.76±0.96 mm(2) vs 6.41±1.30 mm(2) p=0.0008) and lumen area (5.71±0.98 mm(2) vs 6.20±1.27 mm(2) p=0.0155) between 6-months and 2-year follow-up. No differences in plaque composition were reported between groups at either time point. At 2-year clinical follow-up, no differences in ischaemia-driven major adverse cardiac events (7.3% vs 10.2%, p=0.7335), myocardial infarction (4.9% vs 1.7%, p=0.5662) or ischaemia-driven target lesion revascularisation (2.4% vs 8.5%, p=0.3962) were reported between small and large vessels. No deaths or scaffold thrombosis were observed. CONCLUSIONS Similar clinical and angiographic outcomes at 2-year follow-up were reported in small and large vessel groups. A significant late lumen enlargement and positive vessel remodelling were observed in small vessels.
Resumo:
OBJECTIVES Although the use of an adjudication committee (AC) for outcomes is recommended in randomized controlled trials, there are limited data on the process of adjudication. We therefore aimed to assess whether the reporting of the adjudication process in venous thromboembolism (VTE) trials meets existing quality standards and which characteristics of trials influence the use of an AC. STUDY DESIGN AND SETTING We systematically searched MEDLINE and the Cochrane Library from January 1, 2003, to June 1, 2012, for randomized controlled trials on VTE. We abstracted information about characteristics and quality of trials and reporting of adjudication processes. We used stepwise backward logistic regression model to identify trial characteristics independently associated with the use of an AC. RESULTS We included 161 trials. Of these, 68.9% (111 of 161) reported the use of an AC. Overall, 99.1% (110 of 111) of trials with an AC used independent or blinded ACs, 14.4% (16 of 111) reported how the adjudication decision was reached within the AC, and 4.5% (5 of 111) reported on whether the reliability of adjudication was assessed. In multivariate analyses, multicenter trials [odds ratio (OR), 8.6; 95% confidence interval (CI): 2.7, 27.8], use of a data safety-monitoring board (OR, 3.7; 95% CI: 1.2, 11.6), and VTE as the primary outcome (OR, 5.7; 95% CI: 1.7, 19.4) were associated with the use of an AC. Trials without random allocation concealment (OR, 0.3; 95% CI: 0.1, 0.8) and open-label trials (OR, 0.3; 95% CI: 0.1, 1.0) were less likely to report an AC. CONCLUSION Recommended processes of adjudication are underreported and lack standardization in VTE-related clinical trials. The use of an AC varies substantially by trial characteristics.
Resumo:
BACKGROUND Histologic experimental studies have reported incomplete neointimal healing in overlapping with respect to nonoverlapping segments in drug-eluting stents (DESs), but these observations have not been confirmed in human coronary arteries hitherto. On the contrary, angiographic and optical coherence tomography studies suggest that DES overlap elicits rather an exaggerated than an incomplete neointimal reaction. METHODS Optical coherence tomography studies from 2 randomized trials including sirolimus-eluting, biolimus-eluting, everolimus-eluting, and zotarolimus-eluting stents were analyzed at 9- to 13-month follow-up. Coverage in overlapping segments was compared versus the corresponding nonoverlapping segments of the same stents, using statistical pooled analysis. RESULTS Forty-two overlaps were found in 31 patients: 11 in sirolimus-eluting stents, 3 in biolimus-eluting stents, 17 in everolimus-eluting stents, and 11 in zotarolimus-eluting stents. The risk ratio of incomplete coverage was 2.35 (95% CI 1.86-2.98) in overlapping versus nonoverlapping segments. Thickness of coverage in overlaps was only 85% (95% CI 81%-90%) of the thickness in nonoverlaps. Significant heterogeneity of the effect was observed, especially pronounced in the comparison of thickness of coverage (I(2) = 90.31). CONCLUSIONS The effect of overlapping DES on neointimal inhibition is markedly heterogeneous: on average, DES overlap is associated with more incomplete and thinner coverage, but in some cases, the overlap elicits an exaggerated neointimal reaction, thicker than in the corresponding nonoverlapping segments. These results might help to understand why overlapping DES is associated with worse clinical outcomes, both in terms of thrombotic phenomena and in terms of restenosis and revascularization.