69 resultados para Gestural interface
Resumo:
A new haptic interface device is suggested, which can be used for functional magnetic resonance imaging (fMRI) studies. The basic component of this 1 DOF haptic device are two coils that produce a Lorentz force induced by the large static magnetic field of the MR scanner. A MR-compatible optical angular encoder and a optical force sensor enable the implementation of different control architectures for haptic interactions. The challenge was to provide a large torque, and not to affect image quality by the currents applied in the device. The haptic device was tested in a 3T MR scanner. With a current of up to 1A and a distance of 1m to the focal point of the MR-scanner it was possible to generate torques of up to 4 Nm. Within these boundaries image quality was not affected.
Resumo:
Interplay of spin, charge, orbital and lattice degrees of freedom in oxide heterostructures results in a plethora of fascinating properties, which can be exploited in new generations of electronic devices with enhanced functionalities. The paradigm example is the interface between the two band insulators LaAlO3 and SrTiO3 that hosts a two-dimensional electron system. Apart from the mobile charge carriers, this system exhibits a range of intriguing properties such as field effect, superconductivity and ferromagnetism, whose fundamental origins are still debated. Here we use soft-X-ray angle-resolved photoelectron spectroscopy to penetrate through the LaAlO3 overlayer and access charge carriers at the buried interface. The experimental spectral function directly identifies the interface charge carriers as large polarons, emerging from coupling of charge and lattice degrees of freedom, and involving two phonons of different energy and thermal activity. This phenomenon fundamentally limits the carrier mobility and explains its puzzling drop at high temperatures.
Resumo:
PURPOSE To evaluate the effect of the vitreomacular interface (VMI) on treatment efficacy of intravitreal therapy in uveitic cystoid macular oedema (CME). METHODS Retrospective analysis of CME resolution, CME recurrence rate and monthly course of central retinal thickness (CRT), retinal volume (RV) and best corrected visual acuity (BCVA) after intravitreal injection with respect to the VMI configuration on spectral-domain OCT using chi-squared test and repeated measures anova adjusted for confounding covariates epiretinal membrane, administered drug and subretinal fluid. RESULTS Fifty-nine eyes of 53 patients (mean age: 47.4 ± 16.9 years) were included. VMI status had no effect on complete CME resolution rate (p = 0.16, corrected p-value: 0.32), time until resolution (p = 0.09, corrected p-value: 0.27) or CME relapse rate (p = 0.29, corrected p-value: 0.29). Change over time did not differ among the VMI configuration groups for BVCA (p = 0.82) and RV (p = 0.18), but CRT decrease was greater and faster in the posterior vitreous detachment (PVD) group compared to the posterior vitreous attachment (PVA) and vitreous macular adhesion (VMA) groups (p = 0.04). Also, the percentage of patients experiencing a ≥ 20% CRT thickness decrease after intravitreal injection was greater in the PVD group (83%) compared to the VMA (64%) and the PVA (16%) group (p = 0.027), however, not after correction for multiple testing (corrected p-value: 0.11). CONCLUSION The VMI configuration seems to be a factor contributing to treatment efficacy in uveitic CME in terms of CRT decrease, although BCVA outcome did not differ according to VMI status.
Resumo:
The text editor WinEdt 5 may be easily configured to provide a user interface for TDA. The configuration described below allows you to launch TDA command files directly from within WinEdt (via menu or shortcut). TDA's standard output will be written to disk and displayed in WinEdt automatically. Furthermore, you may also just execute selected parts of a command file.