73 resultados para Electromagnetism in medicine.


Relevância:

90.00% 90.00%

Publicador:

Resumo:

In recent years, tumor budding in colorectal cancer has gained much attention as an indicator of lymph node metastasis, distant metastatic disease, local recurrence, worse overall and disease-free survival, and as an independent prognostic factor. Tumor buds, defined as the presence of single tumor cells or small clusters of up to five tumor cells at the peritumoral invasive front (peritumoral buds) or within the main tumor body (intratumoral buds), are thought to represent the morphological correlate of cancer cells having undergone epithelial-mesenchymal transition (EMT), an important mechanism for the progression of epithelial cancers. In contrast to their undisputed prognostic power and potential to influence clinical management, our current understanding of the biological background of tumor buds is less established. Most studies examining tumor buds have attempted to recapitulate findings of mechanistic EMT studies using immunohistochemical markers. The aim of this review is to provide a comprehensive summary of studies examining protein expression profiles of tumor buds and to illustrate the molecular pathways and crosstalk involved in their formation and maintenance.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to analyse the osseointegrative potential of phosphoserine-tethered dendrons when applied as surface functionalisation molecules on titanium implants in a sheep model after 2 and 8 weeks of implantation. Uncoated and dendron-coated implants were implanted in six sheep. Sandblasted and etched (SE) or porous additive manufactured (AM) implants with and without additional dendron functionalisation (SE-PSD; AM-PSD) were placed in the pelvic bone. Three implants per group were examined histologically and six implants were tested biomechanically. After 2 and 8 weeks the bone-to-implant contact (BIC) total values of SE implants (43.7 ± 12.2; 53.3 ± 9.0 %) and SE-PSD (46.7 ± 4.5; 61.7 ± 4.9 %) as well as AM implants (20.49 ± 5.1; 43.9 ± 9.7 %) and AM-PSD implants (19.7 ± 3.5; 48.3 ± 15.6 %) showed no statistically significant differences. For SE-PSD and AM-PSD a separate analysis of only the cancellous BIC demonstrated a statistically significant difference after 2 and 8 weeks. Biomechanical findings proved the overall increased stability of the porous implants after 8 weeks. Overall, the great effect of implant macro design on osseointegration was further supported by additional phosphoserine-tethered dendrons for SE and AM implants.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The limitations of diagnostic echo ultrasound have motivated research into novel modalities that complement ultrasound in a multimodal device. One promising candidate is speed of sound imaging, which has been found to reveal structural changes in diseased tissue. Transmission ultrasound tomography shows speed of sound spatially resolved, but is limited to the acoustically transparent breast. We present a novel method by which speed-of-sound imaging is possible using classic pulse-echo equipment, facilitating new clinical applications and the combination with state-of-the art diagnostic ultrasound. Pulse-echo images are reconstructed while scanning the tissue under various angles using transmit beam steering. Differences in average sound speed along different transmit directions are reflected in the local echo phase, which allows a 2-D reconstruction of the sound speed. In the present proof-of-principle study, we describe a contrast resolution of 0.6% of average sound speed and a spatial resolution of 1 mm (laterally) × 3 mm (axially), suitable for diagnostic applications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Aberrations of the acoustic wave front, caused by spatial variations of the speed-of-sound, are a main limiting factor to the diagnostic power of medical ultrasound imaging. If not accounted for, aberrations result in low resolution and increased side lobe level, over all reducing contrast in deep tissue imaging. Various techniques have been proposed for quantifying aberrations by analysing the arrival time of coherent echoes from so-called guide stars or beacons. In situations where a guide star is missing, aperture-based techniques may give ambiguous results. Moreover, they are conceptually focused on aberrators that can be approximated as a phase screen in front of the probe. We propose a novel technique, where the effect of aberration is detected in the reconstructed image as opposed to the aperture data. The varying local echo phase when changing the transmit beam steering angle directly reflects the varying arrival time of the transmit wave front. This allows sensing the angle-dependent aberration delay in a spatially resolved way, and thus aberration correction for a spatially distributed volume aberrator. In phantoms containing a cylindrical aberrator, we achieved location-independent diffraction-limited resolution as well as accurate display of echo location based on reconstructing the speed-of-sound spatially resolved. First successful volunteer results confirm the clinical potential of the proposed technique.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE The implementation of genomic-based medicine is hindered by unresolved questions regarding data privacy and delivery of interpreted results to health-care practitioners. We used DNA-based prediction of HIV-related outcomes as a model to explore critical issues in clinical genomics. METHODS We genotyped 4,149 markers in HIV-positive individuals. Variants allowed for prediction of 17 traits relevant to HIV medical care, inference of patient ancestry, and imputation of human leukocyte antigen (HLA) types. Genetic data were processed under a privacy-preserving framework using homomorphic encryption, and clinical reports describing potentially actionable results were delivered to health-care providers. RESULTS A total of 230 patients were included in the study. We demonstrated the feasibility of encrypting a large number of genetic markers, inferring patient ancestry, computing monogenic and polygenic trait risks, and reporting results under privacy-preserving conditions. The average execution time of a multimarker test on encrypted data was 865 ms on a standard computer. The proportion of tests returning potentially actionable genetic results ranged from 0 to 54%. CONCLUSIONS The model of implementation presented herein informs on strategies to deliver genomic test results for clinical care. Data encryption to ensure privacy helps to build patient trust, a key requirement on the road to genomic-based medicine.Genet Med advance online publication 14 January 2016Genetics in Medicine (2016); doi:10.1038/gim.2015.167.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

AIM Predictors of renal recovery following conversion from calcineurin inhibitor- to proliferation signal inhibitor-based therapy are lacking. We hypothesized that plasma NGAL (P-NGAL) could predict improvement in glomerular filtration rate (GFR) after conversion to everolimus. PATIENTS & METHODS P-NGAL was measured in 88 cardiac transplantation patients (median 5 years post-transplant) with renal dysfunction randomized to continuation of conventional calcineurin inhibitor-based immunosuppression or switching to an everolimus-based regimen. RESULTS P-NGAL correlated with measured GFR (mGFR) at baseline (R(2) = 0.21; p < 0.001). Randomization to everolimus improved mGFR after 1 year (median [25-75 % percentiles]: ΔmGFR 5.5 [-0.5-11.5] vs -1 [-7-4] ml/min/1.73 m(2); p = 0.006). Baseline P-NGAL predicted mGFR after 1 year (R(2) = 0.18; p < 0.001), but this association disappeared after controlling for baseline mGFR. CONCLUSION P-NGAL and GFR correlate with renal dysfunction in long-term heart transplantation recipients. P-NGAL did not predict improvement of renal function after conversion to everolimus-based immunosuppression.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Diffusion-weighted imaging (DWI) is an established diagnostic tool with regards to the central nervous system (CNS) and research into its application in the musculoskeletal system has been growing. It has been shown that DWI has utility in differentiating vertebral compression fractures from malignant ones, assessing partial and complete tears of the anterior cruciate ligament (ACL), monitoring tumor response to therapy, and characterization of soft-tissue and bone tumors. DWI is however less useful in differentiating malignant vs. infectious processes. As of yet, no definitive qualitative or quantitative properties have been established due to reasons ranging from variability in acquisition protocols to overlapping imaging characteristics. Even with these limitations, DWI can still provide clinically useful information, increasing diagnostic accuracy and improving patient management when magnetic resonance imaging (MRI) findings are inconclusive. The purpose of this article is to summarize recent research into DWI applications in the musculoskeletal system.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE To reliably determine the amplitude of the transmit radiofrequency ( B1+) field in moving organs like the liver and heart, where most current techniques are usually not feasible. METHODS B1+ field measurement based on the Bloch-Siegert shift induced by a pair of Fermi pulses in a double-triggered modified Point RESolved Spectroscopy (PRESS) sequence with motion-compensated crusher gradients has been developed. Performance of the sequence was tested in moving phantoms and in muscle, liver, and heart of six healthy volunteers each, using different arrangements of transmit/receive coils. RESULTS B1+ determination in a moving phantom was almost independent of type and amplitude of the motion and agreed well with theory. In vivo, repeated measurements led to very small coefficients of variance (CV) if the amplitude of the Fermi pulse was chosen above an appropriate level (CV in muscle 0.6%, liver 1.6%, heart 2.3% with moderate amplitude of the Fermi pulses and 1.2% with stronger Fermi pulses). CONCLUSION The proposed sequence shows a very robust determination of B1+ in a single voxel even under challenging conditions (transmission with a surface coil or measurements in the heart without breath-hold). Magn Reson Med, 2015. © 2015 Wiley Periodicals, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

STUDY DESIGN Subgroup analysis of the lumbar spinal stenosis (LSS) without degenerative spondylolisthesis diagnostic cohort of the Spine Patient Outcomes Research Trial multicenter randomized clinical trial with a concurrent observational cohort. OBJECTIVE To determine if sedimentation sign on magnetic resonance image can help with LSS treatment decisions. SUMMARY OF BACKGROUND DATA LSS is one of the most common reasons for surgery in the US elderly, but there is a dearth of reliable diagnostic tools that give a clear indication for surgery. Recent studies have suggested that positive sedimentation sign on magnetic resonance image may be a possible prognostic indicator. METHODS All patients with LSS in both the randomized and observational cohorts had imaging-confirmed stenosis, were surgical candidates, and had neurogenic claudication for at least 12 weeks prior to enrollment. Patients were categorized as "mild," "moderate," or "severe" according to stenosis severity. Of the 654 patients with LSS enrolled in Spine Patient Outcomes Research Trial, complete T2-weighted axial and sagittal digitized images of 115 patients were available for retrospective review. An independent orthopedic spine surgeon evaluated these deidentified Digital Imaging and Communications in Medicine files for the sedimentation sign. RESULTS Sixty-six percent (76/115) of patients were found to have a positive sedimentation sign. Those with a positive sedimentation sign were more likely to have stenosis at L2-L3 (33% vs. 10% P=0.016) or L3-L4 76% vs. 51%, P=0.012), and to have severe (72% vs. 33%, P<0.0001) central stenosis (93% vs. 67% P<0.001) at 2 or more concurrent levels (57% vs. 18%, P=0.01). In multivariate models, the surgical treatment effect was significantly larger in the positive sedimentation sign group for Oswestry Disability Index (-16 vs. -7; P=0.02). CONCLUSION A positive sedimentation sign was associated with a small but significantly greater surgical treatment effect for Oswestry Disability Index in patients with symptomatic LSS, after adjusting for other demographic and imaging features. These findings suggest that positive sedimentation sign may potentially be a useful adjunct to help guide an informed treatment choice regarding surgery for LSS. LEVEL OF EVIDENCE 2.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The thickness of 210 A1 pulleys of 21 male and female healthy volunteers in two different age groups (20-35 y and 50-70 y) were measured by ultrasound. In a second group, the thickness of 15 diseased A1 pulleys and 15 A1 pulleys of the corresponding other hand of 10 patients with the clinical diagnosis of trigger finger were measured by ultrasound. During open trigger finger release, a strip of A1 pulley was excised and immediately measured using an electronic caliper. The average pulley thickness of healthy volunteers was 0.43-0.47 mm, compared to 0.77-0.79 mm in patients with trigger finger. Based on the receiver operating characteristic (ROC) curve, a diagnostic cut-off value of the pulley thickness at 0.62 mm was defined in order to differ a trigger finger from a healthy finger (sensitivity and specificity of 85%). The correlation between sonographic and effective intra-operative measurements of pulley thickness was linear and very strong (Pearson coefficient 0.86-0.90). In order to distinguish between healthy and diseased A1 pulleys, 0.62 mm is a simple value to use, which can be applied regardless of age, sex, body mass index (BMI) and height in adults.