103 resultados para Conventional percolation
Resumo:
Femoroacetabular impingement (FAI) is a pathologic condition of the hip joint in young adults that, if untreated, leads to end-stage osteoarthritis. It is characterized by early pathologic contact between primary osseous prominences of the acetabular rim (so-called pincer FAI) and/or the femoral head-neck junction (cam FAI). Conventional radiographs are often considered normal because classic radiographic signs of osteoarthritis are not present initially. The physician should be aware of the radiographic features for both types of impingement to recognize subtle pathologies.
Resumo:
ATLS Guidelines recommend single plain radiography of the chest and pelvis as part of the primary survey. Such isolated radiographs, usually obtained by bedside machines, can result in limited, low-quality studies that can adversely affect management. A new digital, low-radiation imaging device, the "Lodox Statscan" (LS), provides full-body anterior and lateral views based on enhanced linear slot-scanning technology in just over 5 minutes. We have the first LS in Europe at our facility. The aim of this study was to compare LS with computed tomographic (CT) scanning, as the gold standard, to determine the sensitivity of LS investigation in detecting injuries to the chest, thoracolumbar spine, and pelvis from our own experience, and to compare our findings with those of conventional radiography in the literature.
Resumo:
This study evaluated whether measurements on conventional frontal radiographs are comparable with measurements on cone beam computed tomography (CBCT)-constructed frontal cephalometric radiographs taken from dry human skulls. CBCT scans and conventional frontal cephalometric radiographs were made of 40 dry skulls. With I-Cat Vision((R)) software, a cephalometric radiograph was constructed from the CBCT scan. Standard cephalometric software was used to identify landmarks and calculate ratios and angles. The same operator identified 10 landmarks on both types of cephalometric radiographs on all Images 5 times with a time-interval of 1 week. Intra-observer reliability was acceptable for all measurements. The reproducibility of the measurements on the frontal radiographs obtained from the CBCT scans was higher than those on conventional frontal radiographs. There is a statistically significant and clinically relevant difference between measurements on conventional and constructed frontal radiographs. There is a clinically relevant difference between angular measurements performed on conventional frontal cephalometric radiographs, compared with measurements on frontal cephalometric radiographs constructed from CBCT scans, owing to different positioning of patients in both devices. Positioning of the patient in the CBCT device appears to be an important factor in cases where a 2D projection of the 3D scan is made.
Resumo:
OBJECTIVE: To evaluate the reliability and validity of a novel ultrasound (US) imaging method to measure metacarpophalangeal (MCP) and proximal interphalangeal (PIP) finger joint cartilage. METHODS: We examined 48 patients with rheumatoid arthritis (RA), 18 patients with osteoarthritis (OA), 24 patients with unclassified arthritis of the finger joints, and 34 healthy volunteers. The proximal cartilage layer of MCP and PIP joints for fingers 2-5 was bilaterally visualized from a posterior view, with joints in approximately 90 degrees flexion. Cartilage thickness was measured with integrated tools on static images. External validity was assessed by measuring radiologic joint space width (JSW) and a numeric joint space narrowing (JSN) score in patients with RA. RESULTS: Precise measurement was possible for 97.5% of MCP and 94.2% of PIP joints. Intraclass correlation coefficients for bilateral total joint US scores were 0.844 (95% confidence interval [95% CI] 0.648-0.935) for interobserver comparisons and 0.928 (95% CI 0.826-0.971) for intraobserver comparisons (using different US devices). The US score correlated with JSN for both hands (adjusted R(2) = 0.513, P < 0.001) and JSW of the same finger joints (adjusted R(2) = 0.635, P < 0.001). Reduced cartilage shown by US allowed discrimination of early symptomatic OA versus early RA and healthy joints. In patients with RA, US scores correlated with duration of treatment-resistant, progressive RA. CONCLUSION: The US method of direct visualization and quantification of cartilage in MCP and PIP joints is objective, reliable, valid, and can be useful for diagnostic purposes in patients with arthritis.
Resumo:
PURPOSE: To report the application of a true lumen re-entry device in the bailout treatment of chronic total occlusions (CTO) of the superficial femoral artery (SFA) after failed angioplasty. METHODS: Nineteen patients (12 men; mean age 81 years, range 61-97) with 20 SFA CTOs and Rutherford category 2 to 5 ischemia were prospectively evaluated. All CTOs had unsuccessful recanalization using conventional techniques and were subsequently treated with the Outback LTD catheter. Follow-up at 3, 6, and 12 months included ankle/toe pressure measurement and pulse volume recordings. Endpoints were revascularization rate, target lesion revascularization, and limb salvage. RESULTS: Revascularization was achieved in 95% of the cases. There were 2 (10%) periprocedural complications unrelated to the re-entry device, which were resolved by endovascular or surgical treatment. The target lesion revascularization rate was 10%, with the 2 events occurring at 3 and 6 months, respectively, in patients with Rutherford category 4-5 ischemia. There was one below-the-knee amputation in the patient with failed revascularization. CONCLUSION: The acute failure of endovascular treatment of SFA CTOs is most often due to an inability to re-enter the true lumen after the occlusion is crossed in a subintimal plane. Bailout revascularization with the Outback LTD catheter is highly successful and shows a low device-related complication rate. This needle- and fluoroscopic-based re-entry device increases the endovascular success rate and is therefore expanding the minimally invasive treatment options for surgically unfit patients.
Resumo:
Spectral domain optical coherence tomography (SD-OCT) in patients can deliver retinal cross-sectional images with high resolution. This may allow the evaluation of the extent of damage to the retinal pigment epithelium (RPE) and the neurosensory retina after laser treatment. This article aims to investigate the value of SD-OCT in comparing laser lesions produced by conventional laser photocoagulation and selective retina treatment (SRT).
Resumo:
To compare the effects on body composition and body weight of tibolone vs two different sequential oral or transdermal oestrogen-progestogen hormone replacement therapies versus no therapy.
Resumo:
Postmenopausal bone loss can be prevented by continuous or intermittent estradiol (E2) administration. Concomitant progestogen therapy is mandatory in nonhysterectomized women to curtail the risk of endometrial hyperplasia or cancer. However, the recurrence of vaginal bleeding induced by sequential progestogen therapy in addition to continuous estrogen administration is one of the reasons for noncompliance to hormone replacement therapy (HRT). Tibolone, a synthetic steroid with simultaneous weak estrogenic, androgenic, and progestational activity, which does not stimulate endometrial proliferation, has recently been proposed for the treatment of climacteric symptoms. To compare the efficacy of conventional oral and transdermal HRT with that of tibolone in the prevention of postmenopausal bone loss, 140 postmenopausal women (age, 52 +/- 0.6 years; median duration of menopause, 3 years) were enrolled in an open 2-year study. Volunteers had been offered a choice between HRT and no therapy (control group, CO). Patients selecting HRT were randomly allocated to one of the following three treatment groups: TIB, tibolone, 2.5 mg/day continuously, orally; PO, peroral E2, 2 mg/day continuously, plus sequential oral dydrogesterone (DYD), 10 mg/day, for 14 days of a 28-day cycle; TTS, transdermal E2 by patch releasing 50 microg/day, plus DYD as above. Bone densitometry of the lumbar spine, upper femur, and whole body was performed using dual-energy X-ray absorptiometry at baseline, and then 6, 12, 18, and 24 months after initiation of therapy. One hundred and fifteen women (82%) completed the 2 years of the study. The dropout rate was similar in each group. Over 2 years, bone preservation was observed in all three treatment groups as compared with controls, without significant differences among treatment regimens. In conclusion, tibolone can be regarded as an alternative to conventional HRT to prevent postmenopausal bone loss.
Resumo:
The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond® Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch. These brackets were bonded on identical maxillary acrylic resin models with levelled and aligned teeth and each model was mounted on the orthodontic measurement and simulation system (OMSS). Ten specimens of 0.017 × 0.025 inch and ten 0.019 × 0.025 inch stainless steel archwires (ORMCO) were evaluated in the low- and high-torque 0.018 inch and 0.022 inch brackets, respectively. The wires were ligated with elastomerics into the brackets and each measurement was repeated once after religation. Two-way analysis of variance and t-test were conducted to compare the generated moments between wires at low- and high-torque brackets separately. The maximum moment generated by the 0.017 × 0.025 inch stainless steel archwire in the 0.018 inch brackets at +15 degrees ranged from 14.33 and 12.95 Nmm for the high- and low-torque brackets, respectively. The measured torque in the 0.022 inch brackets with the 0.019 × 0.025 inch stainless steel archwire was 9.32 and 6.48 Nmm, respectively. The recorded differences of maximum moments between the high- and low-torque series were statistically significant. High-torque brackets produced higher moments compared with low-torque brackets. Additionally, in both high- and low-torque configurations, the thicker 0.019 × 0.025 inch steel archwire in the 0.022 inch slot system generated lower moments in comparison with the 0.017 × 0.025 inch steel archwire in the 0.018 inch slot system.
Resumo:
The aim of this study was to assess the effect of bracket type on the labiopalatal moments generated by lingual and conventional brackets. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), In-Ovation L lingual brackets (DENTSPLY GAC), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on identical maxillary acrylic resin models with levelled and aligned teeth. Each model was mounted on the orthodontic measurement and simulation system and 10 0.0175 × 0.0175 TMA wires were used for each bracket type. The wire was ligated with elastomerics into the Incognito, STb, and conventional brackets and each measurement was repeated once after religation. A 15 degrees buccal root torque (+15 degrees) and then a 15 degrees palatal root torque (-15 degrees) were gradually applied to the right central incisor bracket. After each activation, the bracket returned to its initial position and the moments in the sagittal plane were recorded during these rotations of the bracket. One-way analysis of variance with post hoc multiple comparisons (Tukey test at 0.05 error rate) was conducted to assess the effect on bracket type on the generated moments. The magnitude of maximum moment at +15 degrees ranged 8.8, 8.2, 7.1, and 5.8 Nmm for the Incognito, STb, conventional Gemini, and the In-Ovation L brackets, respectively; similar values were recorded at -15 degrees: 8.6, 8.1, 7.0, and 5.7 Nmm, respectively. The recorded differences of maximum moments were statistically significant, except between the Incognito and STb brackets. Additionally, the torque angles were evaluated at which the crown torque fell well below the minimum levels of 5.0 Nmm, as well as the moment/torque ratio at the last part of the activation/deactivation curve, between 10 and 15 degrees. The lowest torque expression was observed at the self-ligating lingual brackets, followed by the conventional brackets. The Incognito and STb lingual brackets generated the highest moments.
Resumo:
The aim of this study was to assess the effect of bracket type on the labiopalatal forces and moments generated in the sagittal plane. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on three identical maxillary acrylic resin models, with a palatally displaced right lateral incisor. The transfer trays for the indirect bonding of the lingual brackets were constructed in certified laboratories. Each model was mounted on the orthodontic measurement and simulation system and ten 0.013 inch CuNiTi wires were used for each bracket type. The wire was ligated with elastomerics and each measurement was repeated once after re-ligation. The labiopalatal forces and the moments in the sagittal plane were recorded on the right lateral incisor. One-way analysis of variance and post hoc Scheffe pairwise comparisons were used to assess the effect on bracket type on the generated forces and moments. The magnitude of forces ranged from 1.62, 1.27, and 1.81 N for the STb, conventional, and Incognito brackets, respectively; the corresponding moments were 2.01, 1.45, and 2.19 N mm, respectively. Bracket type was a significant predictor of the generated forces (P < 0.001) and moments (P < 0.001). The produced forces were different among all three bracket types, whereas the generated moments differed between conventional and lingual brackets but not between lingual brackets.
Resumo:
OBJECTIVE Thermal Nd:YAG laser energy is well known for the purpose of blood coagulation. However, little is known about the bleeding frequency following laser-assisted oral surgery in patients on coumarin drugs. Therefore, the purpose of this study was to compare retrospectively the frequency of bleeding complications following Nd:YAG laserassisted versus conventional local coagulation of blood in oral surgery. METHOD AND MATERIALS In October 2002, minor oral surgical interventions were found to be indicated in a total of 45 cardiac risk patients. In Group 1, blood coagulation was yielded in 24 patients with a Nd:YAG laser system, whereas in Group 2, treatment was performed in 21 patients with conventional means of local hemostasis. All therapies were performed continuing anticoagulant therapy between November 2002 and March 2003. Clinical data were recorded retrospectively from patient charts in May 2007. RESULTS In both Groups 1 and 2, a total of two bleeding complications were recorded. However, local re-interventions were sufficient for local hemostasis. CONCLUSION These results indicate that Nd:YAG laser-assisted local hemostasis was not able to prevent bleeding complications completely. Within the limitations of this retrospective study it was concluded that in patients with anticoagulant treatment undergoing minor oral surgery, Nd:YAG laser-assisted local hemostasis is not superior to conventional methods of blood coagulation with respect to the frequency of bleeding complications.
Resumo:
Distinguishing organic and conventional products is a major issue of food security and authenticity. Previous studies successfully used stable isotopes to separate organic and conventional products, but up to now, this approach was not tested for organic grassland hay and soil. Moreover, isotopic abundances could be a powerful tool to elucidate differences in ecosystem functioning and driving mechanisms of element cycling in organic and conventional management systems. Here, we studied the delta N-15 and delta C-13 isotopic composition of soil and hay samples of 21 organic and 34 conventional grasslands in two German regions. We also used Delta delta N-15 (delta N-15 plant - delta N-15 soil) to characterize nitrogen dynamics. In order to detect temporal trends, isotopic abundances in organic grasslands were related to the time since certification. Furthermore, discriminant analysis was used to test whether the respective management type can be deduced from observed isotopic abundances. Isotopic analyses revealed no significant differences in delta C-13 in hay and delta C-13 in both soil and hay between management types, but showed that delta C-13 abundances were significantly lower in soil of organic compared to conventional grasslands. delta C-15 values implied that management types did not substantially differ in nitrogen cycling. Only delta C-13 in soil and hay showed significant negative relationships with the time since certification. Thus, our result suggest that organic grasslands suffered less from drought stress compared to conventional grasslands most likely due to a benefit of higher plant species richness, as previously shown by manipulative biodiversity experiments. Finally, it was possible to correctly classify about two third of the samples according to their management using isotopic abundances in soil and hay. However, as more than half of the organic samples were incorrectly classified, we infer that more research is needed to improve this approach before it can be efficiently used in practice.