105 resultados para Clinical performance


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this prospective study was to evaluate the 5-year performance and success rate of titanium screw-type implants with the titanium plasma spray (TPS) or the sand-blasted, large grit, acid-etched (SLA) surface inserted in a two-stage sinus floor elevation (SFE) procedure in the posterior maxilla. MATERIAL AND METHODS: A total of 59 delayed SFEs were performed in 56 patients between January 1997 and December 2001, using a composite graft with autogenous bone chips combined with deproteinized bovine bone mineral (DBBM) or synthetic porous beta-tricalcium phosphate (beta-TCP). After a healing period averaging 7.75 months, 111 dental implants were inserted. After an additional 8-14-week healing period, all implants were functionally loaded with cemented crowns or fixed partial dentures. The patients were recalled at 12 and 60 months for clinical and radiographic examination. RESULTS: One patient developed an acute infection in the right maxillary sinus after SFE and did not undergo implant therapy. Two of the 111 inserted implants had to be removed because of a developing atypical facial pain, and 11 implants were lost to follow-up and were considered drop-outs. The remaining 98 implants showed favorable clinical and radiographic findings at the 5-year examination. The peri-implant soft tissues were stable over time; the mean probing depths and mean attachment levels did not change during the follow-up period. The measurement of the bone crest levels (DIB values) indicated stability as well. Based on strict success criteria, all 98 implants were considered successfully integrated, resulting in a 5-year success rate of 98% (for TPS implants 89%, for SLA implants 100%). CONCLUSION: This prospective study assessing the performance of dental implants inserted after SFE demonstrated that titanium implants can achieve and maintain successful tissue integration with high predictability for at least 5 years of follow-up in carefully selected patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to detect occlusal caries. METHODS: The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site. RESULTS: The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy for the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly. CONCLUSIONS: For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure. CLINICAL IMPLICATIONS: When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: Recent studies of drug-eluting stents for unprotected left main coronary artery (LMCA) disease have been encouraging. We examined the performance of sirolimus-eluting stents (SES) for this indication. METHODS AND RESULTS: This retrospective study included 228 consecutive patients (mean age = 68 +/- 11 years, 80.6% men, 26.3% diabetics) who underwent implantation of SES for de novo LMCA stenoses. The mean additive and logistic EuroSCOREs were 5.2 +/- 3.9 and 8.2 +/- 13.2, respectively. The main objective of this study was to measure the rate of major adverse cardiac events (MACE), including death, myocardial infarction and target lesion revascularisation (TLR) at 12 months. Other objectives were to measure the rates of in-hospital MACE and 12-month TLR. Outcomes in 143 patients with (BIF+ group), versus 84 patients without (BIF-group) involvement of the bifurcation were compared. The pre-procedural percent diameter stenosis (%DS) was 60.1 +/- 11.2 in the BIF+ versus 54.7 +/- 12.2% in the BIF- group (p=0.008), and decreased to 18.0 +/- 9.7 and 13.9 +/- 11.3%, respectively (ns), after SES implant. The overall in-hospital MACE rate was 3.5%, and similar in both subgroups. The 1-year MACE rate was 14.5% overall, 16.8% in the BIF+ and 10.7% in the BIF- subgroup (ns). CONCLUSIONS: SES implants in high-risk patients with LMCA stenoses were associated with a low 1-year MACE rate. Stenting of the bifurcation was associated with significant increases in neither mortality nor 1-year MACE rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Muscular counterpulsation (MCP) was developed for circulatory assistance by stimulation of peripheral skeletal muscles. We report on a clinical MCP study in patients with and without chronic heart failure (CHF). METHODS AND RESULTS: MCP treatment was applied (30 patients treated, 25 controls, all under optimal therapy) for 30 minutes during eight days by an ECG-triggered, battery-powered, portable pulse generator with skin electrodes inducing light contractions of calf and thigh muscles, sequentially stimulated at early diastole. Hemodynamic parameters (ECG, blood pressure and echocardiography) were measured one day before and one day after the treatment period in two groups: Group 1 (9 MCP, 11 no MCP) with ejection fraction (EF) above 40% and Group 2 (21 MCP, 14 no MCP) below 40%. In Group 2 (all patients suffering from CHF) mean EF increased by 21% (p<0.001) and stroke volume by 13% (p<0.001), while end systolic volume decreased by 23% (p<0.001). In Group 1, the increase in EF (6%) and stroke volume (8%) was also significant (p<0.05) but less pronounced than in Group 2. Physical exercise duration and walking distance increased in Group 2 by 56% and 72%, respectively. CONCLUSIONS: Noninvasive MCP treatment for eight days substantially improves cardiac function and physical performance in patients with CHF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multiparameter cerebral monitoring has been widely applied in traumatic brain injury to study posttraumatic pathophysiology and to manage head-injured patients (e.g., combining O(2) and pH sensors with cerebral microdialysis). Because a comprehensive approach towards understanding injury processes will also require functional measures, we have added electrophysiology to these monitoring modalities by attaching a recording electrode to the microdialysis probe. These dual-function (microdialysis/electrophysiology) probes were placed in rats following experimental fluid percussion brain injuries, and in a series of severely head-injured human patients. Electrical activity (cell firing, EEG) was monitored concurrently with microdialysis sampling of extracellular glutamate, glucose and lactate. Electrophysiological parameters (firing rate, serial correlation, field potential occurrences) were analyzed offline and compared to dialysate concentrations. In rats, these probes demonstrated an injury-induced suppression of neuronal firing (from a control level of 2.87 to 0.41 spikes/sec postinjury), which was associated with increases in extracellular glutamate and lactate, and decreases in glucose levels. When placed in human patients, the probes detected sparse and slowly firing cells (mean = 0.21 spike/sec), with most units (70%) exhibiting a lack of serial correlation in the spike train. In some patients, spontaneous field potentials were observed, suggesting synchronously firing neuronal populations. In both the experimental and clinical application, the addition of the recording electrode did not appreciably affect the performance of the microdialysis probe. The results suggest that this technique provides a functional monitoring capability which cannot be obtained when electrophysiology is measured with surface or epidural EEG alone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: To determine the activity and tolerability of adding cetuximab to the oxaliplatin and capecitabine (XELOX) combination in first-line treatment of metastatic colorectal cancer (MCC). PATIENTS AND METHODS: In a multicenter two-arm phase II trial, patients were randomized to receive oxaliplatin 130 mg/m(2) on day 1 and capecitabine 1000 mg/m(2) twice daily on days 1-14 every 3 weeks alone or in combination with standard dose cetuximab. Treatment was limited to a maximum of six cycles. RESULTS: Seventy-four patients with good performance status entered the trial. Objective partial response rates after external review and radiological confirmation were 14% and 41% in the XELOX and in the XELOX + Cetuximab arm, respectively. Stable disease has been observed in 62% and 35% of the patients, with 76% disease control in both arms. Cetuximab led to skin rash in 65% of the patients. The median overall survival was 16.5 months for arm A and 20.5 months for arm B. The median time to progression was 5.8 months for arm A and 7.2 months for arm B. CONCLUSION: Differences in response rates between the treatment arms indicate that cetuximab may improve outcome with XELOX. The correct place of the cetuximab, oxaliplatin and fluoropyrimidine combinations in first-line treatment of MCC has to be assessed in phase III trials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effects of palliative chemotherapy with gemcitabine plus capecitabine (GemCap) on patient-reported outcomes measured using clinical benefit response (CBR) and quality-of-life (QOL) measures in patients with advanced biliary tract cancer. PATIENTS AND METHODS: Patients had to manifest symptoms of advanced biliary tract cancer and have at least one of the following: impaired Karnofsky performance score (60 to 80), average analgesic consumption >or= 10 mg of morphine equivalents per day, and average pain intensity score of >or= 20 mm out of 100 mm. Treatment consisted of oral capecitabine 650 mg/m(2) twice daily on days 1 through 14 plus gemcitabine 1,000 mg/m(2) as a 30-minute infusion on days 1 and 8 every 3 weeks until progression. The primary end point was the number of patients categorized as having a CBR or stable CBR (SCBR) during the first three treatment cycles. RESULTS: Forty-four patients were enrolled (bile duct cancer, n = 36; gallbladder cancers, n = 8). The main grade 3 or 4 adverse events included hematologic toxicity and fatigue. After three cycles, 36% of patients achieved a CBR, and 34% achieved an SCBR. Over the full course of treatment, 57% of patients achieved a CBR, and 18% achieved an SCBR. Improved QOL was observed in patients with a CBR or SCBR. The objective response rate was 25%. Median time to progression and overall survival times were 7.2 months and 13.2 months, respectively. CONCLUSION: Chemotherapy with GemCap is well tolerated and effective and leads to a high CBR rate. Patient-reported outcomes are useful for evaluating the effects of palliative chemotherapy in patients with biliary tract cancer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Patients with chemotherapy-related neutropenia and fever are usually hospitalized and treated on empirical intravenous broad-spectrum antibiotic regimens. Early diagnosis of sepsis in children with febrile neutropenia remains difficult due to non-specific clinical and laboratory signs of infection. We aimed to analyze whether IL-6 and IL-8 could define a group of patients at low risk of septicemia. METHODS: A prospective study was performed to assess the potential value of IL-6, IL-8 and C-reactive protein serum levels to predict severe bacterial infection or bacteremia in febrile neutropenic children with cancer during chemotherapy. Statistical test used: Friedman test, Wilcoxon-Test, Kruskal-Wallis H test, Mann-Whitney U-Test and Receiver Operating Characteristics. RESULTS: The analysis of cytokine levels measured at the onset of fever indicated that IL-6 and IL-8 are useful to define a possible group of patients with low risk of sepsis. In predicting bacteremia or severe bacterial infection, IL-6 was the best predictor with the optimum IL-6 cut-off level of 42 pg/ml showing a high sensitivity (90%) and specificity (85%). CONCLUSION: These findings may have clinical implications for risk-based antimicrobial treatment strategies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to determine the performance of a new, 3D-monitor based, objective stereotest in children under the age of four. METHODS: Random-dot circles (diameter 10 cm, crossed, disparity of 0.34 degrees) randomly changing their position were presented on an 3D-monitor while eye movements were monitored by infrared photo-oculography. If > or = 3 consecutive stimuli were seen, a positive response was assumed. One hundred thirty-four normal children aged 2 months to 4 years (average 17+/-15.3 months) were examined. RESULTS: Below the age of 12 months, we were not able to obtain a response to the 3D stimulus. For older children the following rates of positive responses were found: 12-18 months 25%, 18-24 months 10%, 24-30 months 16%, 30-36 months 57%, 36-42 months 100%, and 42-48 months 91%. Multiple linear logistic regression showed a significant influence on stimulus recognition of the explanatory variables age (p<0.00001) and child cooperation (p<0.001), but not of gender (p>0.1). CONCLUSIONS: This 3D-monitor based stereotest allows an objective measurement of random-dot stereopsis in younger children. It might open new ways to screen children for visual abnormalities and to study the development of stereovision. However, the current experimental setting does not allow determining random-dot stereopsis in children younger than 12 months.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Residents demonstrate a broad range of performance levels for clinical skills, with some at an inadequate level. Adequate self-assessment is important for life long learning. However, its accuracy is questioned extensively. The aim of this study was to evaluate how far the residents’ self-assessment predicts their performance in an expert assessment of emergency skills. Summary of work: Twelve skills were identified as being relevant for the emergency duties of residents in smaller hospitals. Fifteen first-year residents from the departments of internal medicine and general surgery at a district hospital rated their performance on a questionnaire (self-assessment). This was followed by a structured, practical in vivo assessment by an anaesthesiologist (expert assessment). For both, a visual analogue scale from 0 to 10 was used, on which 0 stands for novice and 10 for expert. Predictive validity was described by Spearman’s correlation, which was significant in 3 out of 12 skills only. Median correlation (r) was 0.50 (range 0.16 to 0.93). Conclusion: At the beginning of postgraduate training, self-assessment alone is not sufficient to guide self-directed learning. Take-home message: At the beginning of their residency, physicians need structured feedback in emergency skills which can be offered by anaesthesiologists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The C-Port System (Cardica, Inc, Redwood City, Calif) integrates in one tool all functions necessary to enable rapid automated distal coronary anastomoses. The goal of this prospective, nonrandomized, and multicenter study is to determine the safety and efficacy of this novel anastomotic system. METHODS: Five centers enrolled 133 patients awaiting elective coronary artery bypass grafting surgery. Outcome variables were intraoperative device performance, incidence of device-related adverse events, predischarge and 6-month angiographic graft patency, and 12-month clinical outcome. Independent core laboratories performed qualitative and quantitative angiographic and computed tomographic assessments. RESULTS: The C-Port was used to perform a vein-to-coronary anastomosis in 130 patients. Intraoperative conversion to a hand-sewn anastomosis was necessary in 11 patients because of inadequate target site preparation, inappropriate target vessel selection, or both. Inadequate blood flow related to poor runoff required conversion in 3 additional patients. Three patients died before discharge of causes unrelated to the device. At discharge, 113 patients had a C-Port implant in place, and 104 C-Port anastomoses were studied by means of angiography, resulting in 100 FitzGibbon A, 3 FitzGibbon B, and 1 FitzGibbon 0 classifications. At 6 months, one additional patient died of a device-unrelated cause, and 98 patients were evaluated by means of angiography (n = 89). Overall patency (FitzGibbon A) was 92.1%. Three C-Port anastomoses were rated FitzGibbon B, and 4 were rated FitzGibbon 0. At 12 months, 107 (98.2%) of 109 alive patients were followed up, without any reports of device-related major adverse cardiac events. CONCLUSIONS: The C-Port System allows for a rapid, reliable, and compliant distal anastomosis and yields favorable 6-month angiographic and 12-month clinical results when compared with published studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In recent years, there is a growing body of evidence that the University of Wisconsin (UW) solution offers many advantages in organ preservation with regard to preservation quality and time. We, therefore, conducted the first European prospective, randomized, clinical trial comparing myocardial performance after preservation with UW and St. Thomas Hospital (ST) solution. Preliminary results indicated superior heart function after preservation with UW solution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The PAS-Port device (Cardica, Redwood City, CA) allows the rapid deployment of a clampless proximal anastomosis between a vein graft and the aorta. METHODS: Fifty-four patients awaiting elective coronary artery bypass graft surgery were enrolled. Outcome variables were intraoperative device performance, early and 6- month angiographic graft patency, and 12-month clinical follow-up. RESULTS: Sixty-three PAS-Port devices were deployed in 54 patients. Two deployments were unsuccessful. There were no reoperations for bleeding. Two patients died of causes unrelated to the device. Patency evaluation at discharge was performed by angiogram on 49 implants and computed tomography in 2 implants (86% follow-up). At discharge, all evaluated grafts were patent (100%) and rated Fitzgibbon A. At 6-month follow-up, there was no additional mortality; 47 implants (88% follow-up) were evaluated by angiography (Fitzgibbon O [n = 1], Fitzgibbon B [n = 1], and Fitzgibbon A [n = 45]) and 5 by computed tomography. All grafts but 1 were patent (98.1%). At 12 months, 2 additional patients died of causes unrelated to the PAS-Port implant. Forty-six of 50 alive patients (95.8%) were followed up without any reports of device-related major adverse cardiac events. CONCLUSIONS: Discharge (100%) and 6-month patency (98%) are excellent; patency and 12 months' clinical follow-up compares favorably with data from historical hand-sewn controls. The PAS-Port system safely allows the clampless creation of a proximal anastomosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: Lesion length remains a predictor of target lesion revascularisation and results of long lesion stenting remain poor. Sirolimus-eluting stents have been shown to perform better than paclitaxel eluting stents in long lesions. In this substudy of the LEADERS trial, we compared the performance of biolimus biodegradable polymer (BES) and sirolimus permanent polymer stents (SES) in long lesions. METHODS AND RESULTS: A total of 1,707 'all-comer' patients were randomly allocated to treatment with BES and SES. A stratified analysis of angiographic and clinical outcomes at nine months and one year, respectively was performed for vessels with lesion length <20 mm versus >20 mm (as measured by quantitative angiography).Of 1,707 patients, 592 BES patients with 831 lesions and 619 SES patients with 876 lesions had only short lesions treated. One hundred and fifty-three BES patients with 166 lesions and 151 SES patients with 162 lesions had long lesions. There were no significant differences in baseline clinical characteristics, except for higher number of patients with long lesions presenting with acute myocardial infarction in both stent groups. Long lesions tended to have lower MLD and greater percent diameter stenosis at baseline than short lesions. Late loss was greater for long lesions than short lesions. There was no statistically significant difference in late loss between BES and SES stents (0.32+/-0.69 vs 0.24+/-0.57, p=0.59). Binary in-segment restenosis was present in 23.2% versus 13.1% of long lesions treated with BES and SES, respectively (p=0.042). In patients with long lesions, the overall MACE rate was similar for BES and SES (17% vs 14.6%; p=0.62). There was a trend towards higher overall TLR rate with BES (12.4 % vs 6.0%; HR=2.06; p=0.07) and clinically driven TLR (10.5% vs 5.3%: HR 1.94; p=0.13). Rates of definite stent thrombosis were 3.3% in the long lesion group and 1.3-1.7 % in the short lesion group. CONCLUSIONS: BES and SES appear similar with respect to MACE in long lesions in this "all-comer" patient population. However, long lesions tended to have a higher rate of binary in-segment restenosis and TLR following BES than SES treatment.