101 resultados para Articular range of motion
Resumo:
The biomechanical properties of the atlanto-axial joint in a young Yorkshire Terrier dog with spontaneous atlantoaxial instability were compared to those of another young toy breed dog with a healthy atlantoaxial joint. The range-of-motion was increased in flexion and lateral bending in the unstable joint. In addition, lateral bending led to torsion and dorsal dislocation of the axis within the atlas. On gross examination, the dens ligaments were absent and a longitudinal tear of the tectorial membrane was observed. These findings suggest that both ventral and lateral flexion may lead to severe spinal cord compression, and that the tectorial membrane may play a protective role in some cases of atlantoaxial instability.
Resumo:
OBJECTIVES To report clinical signs, diagnostic imaging findings, and outcome in a dog with traumatic myositis ossificans of the origin of the extensor carpi radialis muscle. STUDY DESIGN Clinical report. ANIMALS An 8-month-old intact female Irish Setter Dog. METHODS After radiographic and computed tomographic evaluation of an osseous proliferation arising from the cranial cortex of the right distal humeral diaphysis, the protruding bone was surgically removed and evaluated by histopathology. RESULTS Traumatic myositis ossificans was successfully treated with surgical removal of the osseous proliferation resulting in improved postoperative range of motion of the right elbow joint. There was no evidence of lameness or abnormal bone regrowth associated with the surgical site radiographically at follow up. CONCLUSION Surgical removal of a traumatic myositis ossificans lesion resulted in full return to function in a young, competitive show dog.
Resumo:
This study presents static measurements of the Ca isotopic composition of standard reference materials SRM 915 a/b on a Triton Plus™ thermal ionization mass spectrometer with a specially developed Faraday cup array allowing simultaneous measurement of 40Ca and 48Ca. The total amount of Ca in all analyses was kept < 1 µg. With this setup the measurement uncertainties were 0.06 ‰ for 40Ca/44Ca and 0.12 ‰ for 48Ca/40Ca. Measuring all isotopes simultaneously better allows to test the internal consistency of different Ca isotope abundances reported in the literature. The exponential law was observed to correct incompletely instrumental mass fractionation. An improved fractionation correction based on the exponential law is proposed. It changes the 40Ca/44Ca ratio of SRM 915a (corrected relative to 42Ca/44Ca = 0.31221; 48Ca/44Ca = 0.08871) from 47.1635 ± 0.0028 to 47.1649 ± 0.0047. The measurements of SRM 915b were performed with different analytical conditions (runs were prolonged till complete filament load depletion). Even if the 40Ca/44Ca ratio of SRM 915b, when corrected with the simple exponential law, appears different (47.1532 ± 0.0038) from that of SRM 915a, it becomes coincident (47.1613 ± 0.0028) when corrected with a second-order refinement. This supports the use of the improved exponential law to obtain internally consistent Ca isotope ratio for natural samples.
Resumo:
BACKGROUND Patients after primary hip or knee replacement surgery can benefit from postoperative treatment in terms of improvement of independence in ambulation, transfers, range of motion and muscle strength. After discharge from hospital, patients are referred to different treatment destination and modalities: intensive inpatient rehabilitation (IR), cure (medically prescribed stay at a convalescence center), or ambulatory treatment (AT) at home. The purpose of this study was to 1) measure functional health (primary outcome) and function relevant factors in patients with hip or knee arthroplasty and to compare them in relation to three postoperative management strategies: AT, Cure and IR and 2) compare the post-operative changes in patient's health status (between preoperative and the 6 month follow-up) for three rehabilitation settings. METHODS Natural observational, prospective two-center study with follow-up. Sociodemographic data and functional mobility tests, Timed Up and Go (TUG) and Iowa Level of Assistance Scale (ILOAS) of 201 patients were analysed before arthroplasty and at the end of acute hospital stay (mean duration of stay: 9.7 days +/- 3.9). Changes in health state were measured with the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) before and 6 months after arthroplasty. RESULTS Compared to patients referred for IR and Cure, patients referred for AT were significantly younger and less comorbid. Patients admitted to IR had the highest functional disability before arthroplasty. Before rehabilitation, mean TUG was 40.0 s in the IR group, 33.9 s in the Cure group, and 27.5 s in the AT group, and corresponding mean ILOAS was 16.0, 13.0 and 12.2 (50.0 = worst). At the 6 months follow-up, the corresponding effect sizes of the WOMAC global score were 1.32, 1.87, and 1.51 (>0 means improvement). CONCLUSIONS Age, comorbidity and functional disability are associated with referral for intensive inpatient rehabilitation after hip or knee arthroplasty and partly affect health changes after rehabilitation.
Resumo:
We report a measurement of the νµ-nucleus inclusive charged current cross section (=σ cc) on ironusing data from exposed to the J-PARC neutrino beam. The detector consists of 14 modules in total, which are spread over a range of off-axis angles from 0◦ to 1.1◦. The variation in the neutrino energy spectrum as a function of the off-axis angle, combined with event topology information, is used to calculate this cross section as a function of neutrino energy. The cross section is measured to be σcc(1.1 GeV) = 1.10±0.15 (10^−38cm^2/nucleon), σcc(2.0 GeV) = 2.07±0.27 (10^−38cm^2/nucleon), and σcc(3.3 GeV) = 2.29 ± 0.45 (10^−38cm^2/nucleon), at energies of 1.1, 2.0, and 3.3 GeV, respectively. These results are consistent with the cross section calculated by the neutrino interaction generators currently used by T2K. More importantly, the method described here opens up a new way to determine the energy dependence of neutrino-nucleus cross sections.
Resumo:
Computer modeling of 10 patients' computed tomographic scans was used to study the variables affecting hip arthroplasty range of motion before bony impingement (ROMBI) including acetabular offset and height, femoral offset, height and anteversion, and osteophyte removal. The ROMBI was compared with the ROM before component impingement and the native hip ROM. The ROMBI decreased with decreased total offset and limb shortening. Acetabular offset and height had a greater effect on ROMBI than femoral offset and height. The ROMBI lost with decreased acetabular offset was not fully recoverable with an increase in femoral offset or osteophyte removal. Bony impingement increased and component impingement decreased with decreased acetabular offset and increased head diameter.
Resumo:
Femoroacetabular impingement (FAI) is a pathomechanical concept describing the early and painful contact of morphological changes of the hip joint, both on the acetabular, and femoral head sides. These can lead clinically to symptoms of hip and groin pain, and a limited range of motion with labral, chondral and bony lesions. Pincer impingement generally involves the acetabular side of the joint where there is excessive coverage of the acetabulum, which may be focal or more diffuse. There is linear contact of the acetabulum with the head/neck junction. Cam impingement involves the femoral head side of the joint where the head is associated with bony excrescences and is aspheric. The aspheric femoral head jams into the acetabulum. Imaging appearances are reviewed below. This type is evident in young males in the second and third decades. The main features of FAI are described.
Resumo:
Joint-preserving hip surgery, either arthroscopic or open, increasingly is used for the treatment of symptomatic femoroacetabular impingement (FAI). As a consequence of surgery, thickening of the joint capsule and intraarticular adhesions between the labrum and joint capsule and between the femoral neck and the joint capsule have been observed. These alterations are believed to cause persistent pain and reduced range of motion. Because the diagnosis is made with MR arthrography, knowledge of the normal capsular anatomy and thickness on MRI in patients is important. To date there is no such information available.
Resumo:
STUDY DESIGN:: retrospective analysis of prospectively collected clinical data. OBJECTIVE:: To assess the long-term outcome of patients with monosegmental L4/5 degenerative spondylolisthesis treated with the dynamic Dynesys device. SUMMARY OF BACKGROUND DATA:: The Dynesys® system has been used as a semirigid, lumbar dorsal pedicular stabilization device since 1994. Good short-term results have been reported, but little is known about the long-term outcome following treatment for degenerative spondylolisthesis at the L4/5 level. METHODS:: 39 consecutive patients with symptomatic degenerative lumbar spondylolisthesis at the L4/5 level were treated with bilateral decompression and Dynesys instrumentation. At a mean follow-up of 7.2 years (range 5.0-11.2▒y) they underwent clinical and radiographic evaluation and quality of life assessment. RESULTS:: At final follow-up back pain improved in 89% and leg pain improved in 86% of patients compared to preoperative status. 83% of patients reported global subjective improvement. 92% would undergo the surgery again. 8 patients (21%) required further surgery due to symptomatic adjacent segment disease (6 cases), late onset infection (1 case), and screw breakage (1 case). In 9 cases radiological progression of spondylolisthesis at the operated segment was found. 74% of operated segments showed limited flexion-extension range of less than 4°. Adjacent segment pathology, though without clinical correlation, was diagnosed at the L5/S1 (17.9%) and L3/4 (28.2%) segments. In 4 cases asymptomatic screw loosening was observed. CONCLUSION:: Monosegmental Dynesys instrumentation of degenerative spondylolisthesis at L4/5 shows good long-term results. The rate of secondary surgeries is comparable to other dorsal instrumentation devices. Residual range of motion in the stabilized segment is reduced, and the rate of radiological and symptomatic adjacent segment degeneration is low. Patient satisfaction is high. Dynesys stabilization of symptomatic L4/5 degenerative spondylolisthesis is a possible alternative to other stabilization devices.
Resumo:
Despite different operative and non-operative treatment regimens, the outcome after femoral head fractures has changed little over the past decades. The initial trauma itself as well as secondary changes such as posttraumatic osteoarthritis, avascular necrosis or heterotopic ossification is often responsible for severe loss of function of the afflicted hip joint. Anatomic reduction of all fracture fragments seems to be a major influencing factor in determining the outcome quality. Eight years ago we inaugurated a new surgical approach for better access and visualisation for the treatment of femoral head fractures, using the "trochanteric flip" (digastric) osteotomy. Thus inspection of the entire hip joint and accurate fragment reduction under direct visual control are possible. After good initial experiences with this operative procedure we changed our standard treatment regimen to this approach in an attempt to achieve the most accurate anatomic reduction of the femoral head in every affected patient. Between 1998 and 2006 we operated on 12 patients with femoral head fractures associated with posterior hip dislocation, using the new surgical approach. Patients were followed for 2-96 months and outcome was documented with the Merle d'Aubigne and Postel score as well as the Thompson and Epstein score. The posttraumatic formation of heterotopic bone was documented with the Brooker score. Retrospective analysis of these 12 patients showed good or excellent results in 10 patients (83.3%). The two patients with poor outcome developed an avascular necrosis of the femoral head and underwent total hip arthroplasty. Periarticular heterotopic ossification was seen in five patients. In four patients this caused a significantly reduced range of motion and was therefore considered as a posttraumatic complication. The two patients with the most severe heterotopic bone formation (Brooker III and IV) had initially sustained multiple injuries including brain injury. Comparing our results with earlier published series including our own before changing the treatment protocol, the data suggest a favorable outcome in patients with trochanteric flip (digastric) osteotomy for the treatment of femoral head fractures.
Resumo:
BACKGROUND: Valgus hips with increased antetorsion present with lack of external rotation and posterior hip pain that is aggravated with hip extension and external rotation. This may be the result of posterior femoroacetabular impingement (FAI). QUESTIONS/PURPOSES: We asked whether (1) the range of motion (ROM); (2) the location of anterior and posterior bony collision zones; and (3) the prevalence of extraarticular impingement differ between valgus hips with increased antetorsion compared with normal hips and hips with idiopathic FAI. METHODS: Surface models based on CT scan reconstructions of 13 valgus hips with increased antetorsion, 22 hips with FAI, and 27 normal hips were included. Validated three-dimensional collision detection software was used to quantify the simulated hip ROM and the location of impingement on the acetabular and the femoral sides. RESULTS: Hips with coxa valga and antetorsion showed decreased extension, external rotation, and adduction, whereas internal rotation in 90° of flexion was increased. Impingement zones were more anteroinferior on the femur and posteroinferior on the acetabular (pelvic) side; and the zones were more frequently extraarticular, posterior, or to a lesser degree anterior against the inferior iliac spine. We found a higher prevalence of extraarticular impingement for valgus hips with increased antetorsion. CONCLUSIONS: Valgus hips with increased antetorsion predispose to posterior extraarticular FAI and to a lesser degree anteroinferior spine impingement. LEVEL OF EVIDENCE: Level II, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.
Resumo:
BACKGROUND Periprosthetic infections remain a devastating problem in the field of joint arthroplasty. In the following study, the results of a two-stage treatment protocol for chronic periprosthetic infections using an intraoperatively molded cement prosthesis-like spacer (CPLS) are presented. METHODS Seventy-five patients with chronically infected knee prosthesis received a two-stage revision procedure with the newly developed CPLS between June 2006 and June 2011. Based on the microorganism involved, patients were grouped into either easy to treat (ETT) or difficult to treat (DTT) and treated accordingly. Range of motion (ROM) and the knee society score (KSS) were utilized for functional assessment. RESULTS Mean duration of the CPLS implant in the DTT group was 3.6 months (range 3-5 months) and in the ETT group 1.3 months (range 0.7-2.5 months). Reinfection rates of the final prosthesis were 9.6% in the ETT and 8.3% in the DTT group with no significant difference between both groups regarding ROM or KSS (P = 0.87, 0.64, resp.). CONCLUSION The results show that ETT patients do not necessitate the same treatment protocol as DTT patients to achieve the same goal, emphasizing the need to differentiate between therapeutic regimes. We also highlight the feasibility of CLPS in two-stage protocols.
Resumo:
Acetabular retroversion following acetabular osteotomy in hips with dysplasia can negatively effect the outcome. Total retroversion, where the entire anterior rim is lateral to the posterior rim, is rare and can easily be missed on pelvic radiographs due to the lack of a crossover sign. We evaluated the clinical and radiographic presentation, the surgical management, and the outcome of hips with total acetabular retroversion. We retrospectively reviewed 26 patients (26 hips) with total retroversion following 15 periacetabular osteotomies (PAO), 10 triple type, and one Salter osteotomy. We obtained range of motion (ROM), anterior impingement test, Drehmann's sign, Merle d’Aubigné-Postel score, and Tönnis score for osteoarthrosis. Corrective surgery included 19 revision PAOs and seven total hip arthroplasties (THA). The mean follow-up was 4.7 ± 4.2 (range 0.5-13.8) years. Patients presented with a restricted ROM (flexion and internal rotation), a positive anterior impingement test, a positive Drehmann's sign, and a decreased Merle d'Aubigné-Postel score due to pain. Corrective surgery was performed after mean of 7 ± 5 (1-15) years. Complications for revision PAO and THA occurred in 37% and 29%, respectively. At follow-up, the Merle d'Aubigné-Postel score improved for both revision PAOs and THAs. The prevalence of a positive anterior impingement test and Drehmann's sign decreased for revision PAOs. There was a tendency for progression of OA in hips with revision PAO. Iatrogenic total acetabular retroversion following reorientation is a disabling condition for the patients. Corrective surgery including revision PAO and THA results in improved clinical outcome. However, these procedures are technically challenging and associated with high complication rates.
Resumo:
The acquisition of conventional X-ray radiographs remains the standard imaging procedure for the diagnosis of hip-related problems. However, recent studies demonstrated the benefit of using three-dimensional (3D) surface models in the clinical routine. 3D surface models of the hip joint are useful for assessing the dynamic range of motion in order to identify possible pathologies such as femoroacetabular impingement. In this paper, we present an integrated system which consists of X-ray radiograph calibration and subsequent 2D/3D hip joint reconstruction for diagnosis and planning of hip-related problems. A mobile phantom with two different sizes of fiducials was developed for X-ray radiograph calibration, which can be robustly detected within the images. On the basis of the calibrated X-ray images, a 3D reconstruction method of the acetabulum was developed and applied together with existing techniques to reconstruct a 3D surface model of the hip joint. X-ray radiographs of dry cadaveric hip bones and one cadaveric specimen with soft tissue were used to prove the robustness of the developed fiducial detection algorithm. Computed tomography scans of the cadaveric bones were used to validate the accuracy of the integrated system. The fiducial detection sensitivity was in the same range for both sizes of fiducials. While the detection sensitivity was 97.96% for the large fiducials, it was 97.62% for the small fiducials. The acetabulum and the proximal femur were reconstructed with a mean surface distance error of 1.06 and 1.01 mm, respectively. The results for fiducial detection sensitivity and 3D surface reconstruction demonstrated the capability of the integrated system for 3D hip joint reconstruction from 2D calibrated X-ray radiographs.
Resumo:
Rehabilitation robots have become important tools in stroke rehabilitation. Compared to manual arm training, robot-supported training can be more intensive, of longer duration and more repetitive. Therefore, robots have the potential to improve the rehabilitation process in stroke patients. Whereas a majority of previous work in upper limb rehabilitation robotics has focused on end-effector-based robots, a shift towards exoskeleton robots is taking place because they offer a better guidance of the human arm, especially for movements with a large range of motion. However, the implementation of an exoskeleton device introduces the challenge of reproducing the motion of the human shoulder, which is one of the most complex joints of the body. Thus, this paper starts with describing a simplified model of the human shoulder. On the basis of that model, a new ergonomic shoulder actuation principle that provides motion of the humerus head is proposed, and its implementation in the ARMin III arm therapy robot is described. The focus lies on the mechanics and actuation principle. The ARMin III robot provides three actuated degrees of freedom for the shoulder and one for the elbow joint. An additional module provides actuated lower arm pro/supination and wrist flexion/extension. Five ARMin III devices have been manufactured and they are currently undergoing clinical evaluation in hospitals in Switzerland and in the United States.